Loading...
Plans (10) SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION • SYSTEM SIZE: 7950W DC, 7600W AC • ALL WORK SHALL COMPLY WITH 2014 NEC, 2009 IBC, MUNICIPAL CODE,AND 10 SERVICE ENTRANCE SOLAR MODULES PV-1.0 COVER SHEET • MODULES: (30)CANADIAN SOLAR: CS6P-265P ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. 1 RAIL PV-2.0 SITE PLAN • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. (1) SOLAREDGE TECHNOLOGIES: SE 7600A-US(240V) • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. Mp MAIN PANEL o t o PV-3.0 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. o • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SUB-PANEL STANDOFFS& PV-5.0 SIGNAGE SP • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012 LC PV LOAD CENTER Icy ani I 1 CHIMNEY • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ATTIC VENT • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&6908(b)). ItE1 j 11 FLUSH ATTIC VENT "' °`''!' PM DEDICATED PV METER PVC PIPE VENT APR 19 7f96 • FIREFIGHTER ACCESS: ONE 36"PATHWAY FROM RIDGE TO EAVE AND12" INVERTER(S)WITH METAL PIPE VENT PATHWAY ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. INV INTEGRATED DC �, k ) 1. • ROOF AREA: 1961 SQ.FT. DISCONNECT AND AFCI T-VENT JfrLJNI; ;VISI( • ARRAY AREA:255 SQ.FT. AC • COVERAGE: 13% AC DISCONNECT(S) CP SATELLITE DISH CITY OF TIGARD DC DC DISCONNECT(S) / FIRE SETBACKS REVIEWED FOR CODE COMPLIANCE .-'. / Approved: I OTC: 1 I =1 COMBINER BOX HARDSCAPE Permit#: ii, L 20(b- `- D t' E INTERIOR EQUIPMENT —PL— PROPERTY LINE Address: l ----7--te3E a SHOWN AS DASHED SCALE: NTS sunrun Suite# ,. By: 4,10M Date: 5 A AMPERE 'UP'. AC ALTERNATING CURRENT OR CL#180464 i. AFCI ARC FAULT CIRCUIT INTERRUPTER M AZIMUTH VICINITY MAP OMP COMPOSITION 3380 OFFICE COPY DC DIRECT CURRENT PHONE 888SE88. PORTLAND,OR 97202 .85857.8527 (E) EXISTING FAX 503.205.0748 EXT EXTERIOR CUSTOMER RESIDENCE: FRM FRAMING CASEY ROBBINS INT INTERIOR 15213 SW 98TH AVE,TIGARD, LBW LOAD BEARING WALL OR,97224 MAG MAGNETIC MSP MAIN SERVICE PANEL TEL.(971)344-2004 APN#:2S111CA10800 (N) NEW PROJECT NUMBER: NTS NOT TO SCALE OC ON CENTER 601R-213ROBB �! PRE-FAB PRE-FABRICATED DESIGNER: 1152135WI8th Ave PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC MICHAEL LANDA 805.540 8310 TL TRANSFORMERLESS DRAFTER: TYP TYPICAL V VOLTS RBEL W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET A REV:A 4/19/2016 PAGE PV-1 .0 ` PITCH TRUE MAG PV AREA SITE PLAN -SCALE= 1/16"= 1'-0" AZIM AZIM (SQFT) T AR-01 31° 244° 228° 520 IN/ PL PL PL r (E) RESIDENCE N .‘... ."-7."%2IL114--":\ * 13- '1* \t 411* ®#0‘ 4014741111\ eFIRE SETBACKS �04, \ MP SM�NV II, . ov --#- , sunrun (E) POOL , . < �_� � OR CL#180464 (N)ARRAY AR-01 ' 3380 S E 20TH,PORTLAND,OR 97202 PHONE 888.657.6527 A0 FAX 503205.0748 N ', CUSTOMER RESIDENCE: \ , , CASEY ROBBINS 15213 SW 98TH AVE,TIGARD, OR, 97224 \ ,,;\ TEL.(971)344-2004 APN#:2S111 CA10800 N PROJECT NUMBER: 601R-213R0 BB Ac ', DESIGNER: b \I MICHAEL LANDA P 805.540 6310 $�N s� DRAFTER: RBEL SHEET SITE PLAN REV:A 4/19/2016 PAGE PV-2.O ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACINGZONE SPAN OVERHANG - _ MODULES: AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC/ WOOD RAFTER/ 2 X 8/ 13'-6" 24" N/A 4'-0" 1'-4" CANADIAN SOLAR: CS6P-265P - VAULTED PREFABRICATED TRUSS 2 X 4 MODULE DIMS: D1 -AR-01 -SCALE: 1/8"= 1%0" 64.5"x 38.7"x 1.57" PITCH: 31° 4' 9"—, 29.4 MODULE CLAMPS: AZIM: 244° Portrait: 13.39" 16.14" r1' Landscape: 7.87"-9.84" e , j /,//„„,,/,<,/,„„/„A„,,„„/„,/ ,4 MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 25 PSF .: 0 0 0 8a% 0 0 0 0894:16) 0 0 © 0 0 -11116,/ � WIND SPEED: /// 95 MPH 3-SEC GUST. 0 0 0 0 0 0 0 0- 0 0 0 0 0 0 0/ LAG SCREWS: / / 5/16"x3.5": 2.5"MIN EMBEDMENT o 0 0 0 0 0 0� / -�4'TYP�- NOTE: /� INSTALLERS TO VERIFY RAFTER / 0 0 0 0 0 0 - 0 0 0/ SIZE, SPACING AND SLOPED 21-7" / / SPANS,AND NOTIFY E.O.R. OF // o 0 0 0 / ANY DISCREPANCIES BEFORE 2 i/ PROCEEDING. o o / / o o 0 0/ 85% / 0 0 0 0 / o o o 0 O L/ /////////� / 85% / / ` / A / /84% 82% 80% 7 f. ` D1: A INDICATES TSRF VALUE AT MARKED LOCATION. 3'-4" , 19' 6" SUI111,11111 HOUSE ROOF FRAMING DETAIL-SCALE: NTS ELEVATION DETAIL-SCALE: NTS OR CL#180464 f 6"MAX 3380 S E 20TH,PORTLAND,OR 97202 PHONE 888.857.6527 5/16"X 3.5"LAG SCREW. _ FAX 503.205.0748 1 BOLT PER PENETRATION \ CUSTOMER RESIDENCE: � CASEY ROBBINS 15213 SW 98TH AVE, TIGARD, COMP SHINGLE ROOF , � M � � OR, 97224 � SOLAR MODULE i \ TEL.(971)344-2004 APN#:25111 CA10800 PROJECT NUMBER: TOP PLATE 26' 601 R-213ROB6 2x8 RAFTERS/2Xa DESIGNER: PRE-FABRICATED / \ MICHAEL LANDA TRUSSES,24"O.C. 805 540 8310 DRAFTER: LOAD BEARING WALL = = RBEL I 11'6" SHEET VAULTED SECTION LAYOUT ATTIC SECTION — T= )I 1=1 f I—(Tl--�I - --I f f--(Tl T! 1 =I!1=7 I I ` 120/240 VAC SINGLE PHASE SERVICE © METER < PGE 24544 4147 UTILITY GRID- EXISTING /1 200A MAIN ( BREAKER \1 (END FED) , --� EXISTING SOLAREDGE < �� 200A TECHNOLOGIES: SE MAIN (N)LOCKABLE 7600A-US(240V) FACILITY - PANEL BLADE TYPE (N)SUN RUN 7600 WATT INVERTER 2 AC DISCONNECT METER JUNCTION BOX /-1 PV MODULES LOADS OR EQUIVALENT CANADIAN SOLAR: CS6P-265P 3 3 3 ..1 N /// (30)MODULES ° �' ® -� �-- +0OPTIMIZERS WIRED IN (1)SERIES OF (15) -- OPTIMIZERS AND(1)SERIES OF(15) 40A PV £GROUND SQUARED 250V METER OPTIMIZERS BREAKER AT DU222RB SOCKET LOAD RATED DC SOLAREDGE POWER OPTIMIZER OPPOSITE END 3R,60A,2P 125A CONTINUOUS DISCONNECT&AFC' P300 OF BUSBAR 120/240VAC & 240V METER 200A, FORM 2S CONDUIT SCHEDULE NOTES TO INSTALLER: 1. 15 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. # CONDUIT CONDUCTOR NEUTRAL GROUND 2. ADD 40 AMP PV BREAKER TO MAIN PANEL. sunrun 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER SOLAREDGE SYSTEM NOTES: 2 3/4"EMT OR EQUIV. (4) 10 AWG THHTHWN-2 NONE (1)6 AWG THHN/THWN-2 1. SOLAREDGE INVERTER AND OPTIMIZERS ARE A LISTED SYSTEM. N/ 2. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 MAINTAINED AT 350V DC(NOMINAL). OR CL#180464 3. STRING VOLTAGE IS ELECTRONICALLY LIMITED BY INVERTER TO 500V DC, MAX. 4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS 3380SE 20TH,PORTLAND,OR 97202 ELECTRONICALLY LIMITED TO 15A MAX(PER STRING). PHONE 888.857.8527 FAX 503.205.0748 MODULE CHARACTERISTICS 5. SOLAREDGE DC SAFETY SWITCH DISCONNECTS BOTH POSITIVE AND OPTIMIZER CHARACTERISTICS NEGATIVE DC CONDUCTORS AS REQUIRED BY NEC690.35(A). CUSTOMER RESIDENCE: CANADIAN SOLAR: 265 W CASEY ROBBINS CS6P-265P MIN INPUT VOLTAGE 8 VDC 15213 SW 98TH AVE,TIGARD, OPEN CIRCUIT VOLTAGE 37.7 V MAX INPUT VOLTAGE 48 VDC OR, 97224 MAX POWER VOLTAGE 30.6 V MAX INPUT ISC 10 ADC TEL.(971)344-2004 APN#:2S111CA10800 SHORT CIRCUIT CURRENT 9.23 A MAX OUTPUT CURRENT 15 ADC PROJECT NUMBER: 601 R-213ROBB SYSTEM CHARACTERISTICS-INVERTER 1 DESIGNER: MICHAEL LANDA SYSTEM SIZE 7950 W 805.540.6310 SYSTEM OPEN CIRCUIT VOLTAGE 15 V DRAFTER: RBEL SYSTEM OPERATING VOLTAGE 350 V SHEET MAX ALLOWABLE DC VOLTAGE 500 V ELECTRICAL - SYSTEM OPERATING CURRENT 22.7 A SYSTEM SHORT CIRCUIT CURRENT 30 A REV:A 4/19/2016 PER CODE:890.52 PAGE PV-4.0 • PHOTOVOLTAIC SYSTEM AC DISCONNECT PHOTOVOLTAIC POWER RATED AC OPERATING CURRENT 31.67 AMPS SOURCE BREAKERS ELECTRIC SHOCK HAZARD AC NOMINAL OPERATING VOLTAGE 240 VOLTS ARE BACKFEEDING THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED 240 VOLTS • AND MAY BE ENERGIZED LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION 32 AMPS (PER CODE:NEC690.54) LABEL LOCATION: LABEL LOCATION: DC DISCONNECT,INVERTER WARNING AC BREAKER AND AC DISCONNECT (PER CODE:NEC 690.35(F)) [Inside or front of panel] [To be used when inverter is ungrounded] INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CUSTOMER OWNED SOLAR )` LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION GENERATOR OUTPUT DO NOT TOUCH TERMINALS (PER CODE:NEC 705.12(D)(7)) LABEL LOCATION: TERMINALS ON BOTH LINE AND [Not required if panelboard is rated not less than sum of ampere ratings SUNRUN METER LOAD SIDES MAY BE ENERGIZED of all overcurrent devices supplying it] INA E OPALWAY PR CAUTION : SOLAR CIRCUIT DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE LABEL LOCATION: EXPOSED TO SUNLIGHT MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES, LABEL LOCATION: AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND ABOVE/BELOW AC DISCONNECT,POINT OF INTERCONNECTION PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE:IFC605.11.1.4) (PER CODE:NEC 690.17(E)) • SOLAR DISCONNECT . : . LABEL LOCATION: ELECTRIC SHOCK HAZARD DISCONNECT,POINT OF INTERCONNECTION DO NOT TOUCH TERMINALS (PER CODE:NEC690.13(B)) TERMINALS ON BOTH LINE AND INVERTER 1 LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: RATED MAXIMUM POWER- 22.7 A AC DISCONNECT,POINT OF INTERCONNECTION POINT CURRENT (Imp) PER CODE:NEC 690.17(E),CB RATED MAXIMUM POWER- Sun run POINT VOLTAGE (Vmp) 350 V WARNING-Electric Shock Hazard MAXIMUM SYSTEM No user serviceable parts inside /1 VOLTAGE (VOC) 15 V authorizedContactMAXIMUM CIRCUIT serviceproviderforassistance A OR CL#180464 CURRENT I 30 LABEL LOCATION: INVERTER,JUNCTION BOXES(ROOF),AC DISCONNECT (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) 3380 S E 20TH,PORTLAND,OR 97202 LABEL LOCATION: PHONE 888 657 6527 WARNING: PHOTOVOLTAIC DC DISCONNECT,INVERTER FAX 503205.0748 POWER SOURCE (PER CODE:NEC690.53) CUSTOMER RESIDENCE: LABEL LOCATION: CONDUIT,COMBINER BOX CASEY BOBBINS (PER CODE:CEC690.31(GX3X4)&CEC 690.13(GX4) 15213 SW 98TH AVE,TIGARD, OR,97224 TEL.(971)344-2004 APN#:2S111 CA10800 LABEL LOCATION: PROJECT NUMBER: POINT OF INTERCONNECTION 601 R-213ROBB (PER CODE:NEC 705.12(D)(4)) CAUTION:SOLAR ELECTRIC DESIGNER: SYSTEM CONNECTED MICHAEL LANDA 805 540 8310 LABEL LOCATION: DRAFTER: POINT OF INTERCONNECTION REEL (PER CODE:NEC690.15,690.13(B)) • ADHESIVE FASTENED SIGNS: •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT SHEET SIGNAGE WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. REV:A 4/19/2016 •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER PAGE PV-5.O RESISTANT[IFC 605.11.1.3] • Cl) • solar - $ SolarEdge Single Phase Inverters CC For North America ,•••\ . • • A , seal "rt.,‘1431'ia 4 -•• 's• • ••," ' The best thoit.:t ff)r SolarEeige ez-Iii!,)ld systems fz to NEC 20:1.3 C 2C.1.-'1;;;E:0.1.2 "'• tc. 6,-, ' „ !----- solar Single Phase Inverters for North America ' \__..-i.fi .e8*',it ,.S - S_ ,,ss.. s;C.Q,.,. s S_.:LA .'.t,1,1.,...' ..4 51.s...41. 5/ ,+S f?S air '.7,....;,01 ,. .,. ta.i\ .• .y 1•1: S' e', _ `'. +/',;lg ..ti s NOW' ,r,,u ,, u:r?0.1r1 4050 5100 i)0 S750 41 GG ..2..5i - iiE183:515 il • ,,orres ,.i t ..<9 Yes :115.,x t!:p/* qx,7 •,OO ‘'ii': ' ., 1I,...!nout t 7 32 .I 2080/353 q,240v vcc 6.'x("1,208'v Max.rrrputC. 9.5 13 25 34.1Ade Max Inpul St',urt 0l5ctlit Cup rc.r•t 45 Ade • 41. {+o1Y 97';) , ,. . Ytl .,,.- :,. ., ,_t.,Je.r:;..lo 0;',4 ,,,N,,s.tivit'y, ,.. ,..,.., inVO:a.. ,. ,.ze 9;•:.1 9i. :;i9 58 `.: • itit ..... ,. . ,. A;,?MI ONAZ. -TA :'t`i «port'S C.,,+ :f?. ,.,.;,. .,+ ,.3 Is - 4..485, , .,. ,ll. e I0p0. R d Sta I , NE0 211121 690.12 Y,-.> STANDARD COMPLIANCE Sir . !:.119(.18 f.-:',',22 2 :i;'-,s F(.6 4 ..,.sr 13 INSTALLATION SfECIFI AFIQNS AC .., t . .•.'.-E_ C , ,Viii, .. 3/4" .....,/2f,-.•A',','.1 2,14"01•0:41•01,-n/4-3 AWG • PK l,u'.co ...se- ,� - 1./3'ree.maiala, 5. _ ``/ 14-6/oNC < .,S'.;i :4,;,-„{ .5 12,5 10.5 t '.J3 i3. 3 2/777,x315/i '4 ti,iii, 775 SJ K 293/ ., „`v..g1-0 Wi S,-,{, ?r 9 7d:ir5 51 7 I 23 2 54.7/24. 0.:, 4 I 40_, ,r,/I,•,:. , 0-.X.,!;,,,,, 1 1U,a _t,,v_ctie• ,7 ,,._. ai r,,,(us)' .._3`3'+_i) 11(73;,39 J., . \ i... , , ,..✓v . __i 33/.1.' c- S a `' off 9'SnierEdge Technologies,Inc.,All,:ghts reserved.SOtAREDGE,rhe 5otarEa._,logu.OPTIMIZE0 6Y 50LAREDGE art Traderen,1 k.S or revstered treden erk a c9t°SolarE..dge Tecimologes,Mo.Atl other tredeSkeks otestie set herein are trademavks of their resph ctrve auris*$.Date:01./20,i ,SV.C.V.Sdbjaet to 9ROngt without notiCe. M N M?: +vt< CanadianSolar *Black frame CS6 P-2601265 P product can be provided upon request. High quality and reliability in all Canadian Solar modules is ensured by 14 years'experience in insurance-backed warranty module manufacturing,well-engineered module ?5 non-cancelable,immediate warranty insurance design,stringent BOM quality testing,an automated ` .,, ,,,,,,, ` linear power output warranty manufacturing process and 100%EL testing. • 10 product warranty on materials years and workmanship KEY FEATURES Excellent module efficiency up to 16.47% MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2008/Quality management system ISO/TS 16949:2009/The automotive industry quality management system Outstanding low irradiance ISO 14001:2004/Standards for environmental management system performance:96.5% OHSAS 18001:2007/International standards for occupational health&safety PRODUCT CERTIFICATES* Positive power tolerance IEC 61215/IEC 61730:VDE/CE/MCS/JET/SII/CEC AU/INMETRO/CQC up t0 5 W UL 1703/IEC 61215 performance:CEC listed(US)/FSEC(US Florida) UL 1703:CSA/IEC 61701 ED2:VDE/IEC 62716:VDE/IEC 60068-2-68:SGS PV CYCLE(EU)/UNI 9177 Reaction to Fire:Class 1 High PTC rating up to 92.0% 4 crus` E s CERT GSE SA- BBAV ':�<� Pv�Y��t -: 4=— *As there are different certification requirements in different markets,please contact (P67 junction box for long-term your local Canadian Solar sales representative for the specific certificates applicable to weather endurance the products in the region in which the products are to be used. Heavy snow load up to 5400 Pa CANADIAN SOLAR INC.is committed to providing high quality wind load up to 2400 Pa solar products,solar system solutions and services to customers around the world.As a leading manufacturer of solar modules and Salt mist,ammonia and blown PV project developer with about 10 GW of premium quality modules sand resistance,for seaside, deployed around the world since 2001,Canadian Solar Inc.(NAS- farm and desert environments DAQ:CSIQ)is one of the most bankable solar companies worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario Ni K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com MODULE/ENGINEERING DRAWING(mm) CS6P-260P/I-V CURVES • A A Rear View Frame Cross Section A-A 10 to 9 9' • ' 35 8 8 • _ I - lin "r' , 7 2 ! �. Grounding V�9��r 4 4 IIS ` °^�", hole NI 3 3 .Z726i G -- 11 2 • 2 I Mounting Hole 1 5 10 15 20 25 30 35 40 5 10 IS 20 25 30 35 40 211.7 AI.,,�A Mounting { hole -�- it • 1000 W/m' 5°C • -.. _— • BOO W/m2 25°C • 1140 ._°ao �1 982 _!_ 600 W/m' 45°C I L._ — • 400 W/m' 65°C ■ �J • ELECTRICAL DATA I STC* MODULE I MECHANICAL DATA Electrical (Doty CS6P 260P 265P Specification Data Nominal Max.Power(Pmax) 260 W 265 W Cell Type Poly-crystalline,6 inch Opt.Operating Voltage(Vmp) 30.4 V 30.6 V Cell Arrangement 60(6x 10) Opt.Operating Current(Imp) 8.56 A 8.66 A Dimensions 1638x982 x40 mm(64.5x38.7x1.57 in) Open Circuit Voltage(Voc) 37.5 V 37.7 V Weight 18 kg(39.7 lbs) Short Circuit Current(Isc) 9.12 A 9.23 A Front Cover 3.2 mm tempered glass Module Efficiency 16.16% 16.47% Frame Material Anodized aluminium alloy Operating Temperature -40°C-+85°C )-Box IP67,3 diodes Max.System Voltage 1000 V(IEC)or 1000 V(UL) Cable 4 mm2(IEC)or 4 mm2&12 AWG Module Fire Performance TYPE 1 (UL 1703)or 1000 V(UL),1000 mm(39.4 in) CLASS C(IEC 61730) (650 mm(25.6 in)is optional) Max.Series Fuse Rating 15 A Connectors Friends PV2a(IEC), Application Classification Class A Friends PV2b(IEC/UL) Power Tolerance 0-+5 W Standard 26 pieces,515 kg(1135.4 lbs) *Under Standard Test Conditions(STC)of irradiance of 1000 W/m2,spectrum AM Packaging (quantity&weight per pallet) 1.5 and cell temperature of 25°C. Module Pieces per Container 728 pieces(40'HQ) ELECTRICAL DATA I NOCT* [leni I a ol Data CS6P 260P 265P TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 189 W 192 W Specification Data Opt.Operating Voltage(Vmp) 27.7 V 27.9 V Temperature Coefficient(Pmax) -0.41%1°C ' Opt.Operating Current(Imp) 6.80 A 6.88 A Temperature Coefficient(Voc) -0.31%/°C Open Circuit Voltage(Voc) 34.5 V 34.7 V Temperature Coefficient(Isc) 0.053%1°C Short Circuit Current(Isc) 7.39 A 7.48 A Nominal Operating Cell Temperature 45±2°C *Under Nominal Operating Cell Temperature(NOCT),irradiance of 800 W/m2, spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation,average 96.5%relative efficiency from an irradiance of 1000 W/m2 to 200 W/m2(AM 1.5,25°C). • The specification and key features described in this datasheet may deviate slightly - • and are not guaranteed.Due to on-going innovation,research and product enhancement,Canadian Solar Inc.reserves the right to make any adjustment to the information described herein at any time without notice.Please always obtain the most recent version of the datasheet which shall be duly incorporated into the ° binding contract made by the parties governing all transactions related to the . purchase and sale of the products described herein. -------- - - - - Caution: For professional use only.The installation and handling of PV modules Scan this QR-code to discover solar 0 n 1• 0 • • requires professional skills and should only be performed by qualified professionals. r •-:i r. • Please read the safety and installation instructions before using the modules. projects built with this module t 1,`; •r 0l7:•L'•i. • :iri : CANADIAN SOLAR INC.August 2015.All rights reserved,PV Module Product Datasheet V5.3_EN 0 L. -j