Report Table Of Contents
Project: 'Untitled78 03/05/2013
Prepared By: 04:53PM
1.5T 3
Unit Report 4
Performance Summary 5
Acoustic Summary 5
Certified Drawing 7
Unit Feature Sheet g
2T 11
Unit Report 12
Performance Summary 13
Acoustic Summary 14
Certified Drawing 15
Guide Specifications 17
Unit Feature Sheet 19
2.5T 21
Unit Report 22
Performance Summary 23
Acoustic Summary 24
Certified Drawing 25
Unit Feature Sheet 27
3T 29
Unit Report 30
Performance Summary 31
Acoustic Summary 32
Certified Drawing 33
Unit Feature Sheet 35
4T 37
Unit Report 38
Performance Summary 39
Acoustic Summary 40
Certified Drawing 41
Unit Feature Sheet 43
J
Residential Carrier Products Bldr 1.19k Page 2 of 44
1.5T
,, Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
1.5T
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Unit Feature Sheet
Residential Carrier Products Bldr 1.19k Page 3 of 44
Unit Report For 1.5T
Project: -'Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC Unit Model: CNPH
Unit Size: 1.5 Tons Unit Size: 2 Tons
Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width: 17 inch
System Parameter
System Quantity: 1
Furnace Type: 59*P5A040E14**10
Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight
Unit Length: 2'3.0" Unit Length: 1'8.8"
Unit Width: 2'6.0" Unit Width: 1'6.0"
Unit Height: T 9.0" Unit Height: 1 7.0"
Unit Shipping Weight: 163 lb Unit Shipping Weight: 37 lb
Note:Outdoor unit dimensions may vary depending on the
minor series sent from the factory.
Warranty Information Indoor
CNPH First Year-Parts Only(Standard)
Warranty Information Outdoor
24ACC First Year-Parts Only(Standard)
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ACC618A003 Air Conditioner with Puron Refrigerant 1.5 Tons Cooling 1
Base Unit
16 SEER @ ARI Conditions 1
Standard 1
Accessories
KSAHS1701AAA Start Assist-Capacitor and Relay 1
KAACH1701AAA Crankcase Heater 1
Base Unit-Indoor
CNPHP2417ALA Cased Horizontal N-Coil Evaporator Coil with Puron 1
Base Unit
Painted 1
17 inch 1
Aluminum 1
Residential Carrier Products Bldr 1.19k Page 4 of 44
Performance Summary For 1.5T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
System: 24ACC/CNPH
System Quantity: 1
Altitude: 0.0 ft
Furnace Type: 59*P5A040E14**10
Linear Pipe Length: 0.0 ft
Actual SEER: 15.5
EER @ ARI Conditions: 12.7
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC618A003 Unit Model: CNPHP2417ALA
Unit Size(Nominal): 1.5 Tons Unit Size(Nominal): 2 Tons
Voltage: 208/230-1-60 V-Ph-Hz Actual Airflow: 600.0 CFM
Clg Ent Air DB Ambient: 95.0 °F Standard Airflow: 600.0 CFM
Total Net Clg Capacity: 18.00 MBH
Net Sensible Clg Capacity: 12.80 MBH
Ent Air DB: 80.00 °F
Ent Air WB: 67.00 °F
Ent Enthalpy: 31.44 BTU/lb
Lvg Air DB: 60.25 °F
Lvg Air WB: 57.60 °F
Lvg Enthalpy: 24.77 BTU/lb
Indoor Unit External Static: 0.50 in wg
Total System Power: 1.41 kW
Outdoor Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz
Fan Motor FLA: 0.50 Amps
MCA: 11.8 Amps
Max Fuse: 20 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA: 9.0 Amps
Compressor LRA: 48.0 Amps
Min Wire Size @ 60C: 14
Min Wire Size @ 75C: 14
Max Length Wire Size @ 60C: 67 ft
Max Length Wire Size @ 75C: 64 ft
Acoustics
Sound Power Levels, db re 10E-12 Watts
Outdoor Unit(dB) Indoor Unit(dB)
DBA Level 74.0 NA
63Hz NA NA
125Hz 53.0 NA
250Hz 60.5 NA
500Hz 65.0 NA
1000Hz 67.0 NA
2000Hz 63.5 NA
4000Hz 60.0 NA
8000Hz 52.0 NA
Sound Message No Indoor sound
data available.
Residential Carrier Products Bldr 1.19k Page 5 of 44
Acoustic Summary For 1.5T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters:
Tag Name: 1.5T
Unit Model: 24ACC
Unit Size: 1.5 Tons
Variations: Standard
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 53.0 60.5 65.0 67.0 63.5 60.0 52.0 _
A-Weighted Sound Power, dBA 74.0
Indoor Unit Parameters:
Tag Name: 1.5T
Unit Model: CNPH
Unit Size: 2 Tons
Cabinet Insulation: Painted
Octave Band Center Frequency, Hz 63 125 250 500 _ 1k 2k 4k 8k dBA
Sound Power,dB 0.0 0.0 0.0 0.0 0.0 _ 0.0 0.0 0.0
A-Weighted Sound Power, dBA 0.0
Residential Carrier Products Bldr 1.19k Page 6 of 44
F X N '
a m o
m
v m
CD
7 CI".
SI. DIMENSIONS- ENGLISH
CO C
✓ -
ELECTRICAL OPERATING SHPPING SHIPPING a
CD um.USERIES A B C D E F G K L M N P
CHARACTERISTICS WEIGHT (bs1 WEIGHT lbs) DIMENSIONS (L x W x HI w
24ACC618 0 1 3 0 0 0 25 3/4" 28 11116' 3 3/4' 3/4' 4 7/16" 21 1/4' 7 13/16' 2 13/16 1/2' 13 1/4' 13 3/4' 12 3/4' 136 163 26 1/8' X 30 1/16" S 32 9/16'
p 24ACC624 0 X 0 0 0 31 3/16" 28 5/16" 3 3/4" 3/4" 6 9/16" 24 11/16" 9 1/8" 2 13/16" 112' 15 5/8" 15 1/2' 14' 163 198 32 3/8" X 35 1/2' X 32 9/16"
ca' I 24ACC630 0 X 0 0 0 31 3/16' 32 5/16" 3 3/4' 3/4' 6 9/16" 24 11/16" 9 1/8" 2 13/16" I/2" 16 1/2' 15' 14 3/4' 161 204 32 3/8' X 35 1/2' X 35 15/16"
C
n 24ACC636 0 ' X 0 0 0 35' 28 5/16' 3 7/8' 7/8' 6 9/16" 28 7116" 9 118" 2 15/16" 518' 18 1/4' 16 7/8' 14' 180 219 36 118' X 39 5/16" X 32 9116'
co1' 24ACC642 0 X 0 D 0 35" 39 1/8" 3 7/8' 7/8' 6 9/16" 28 7116" 9 118" 2 15/16" 518' 18' 16" 17 1/2" 231 281 36 1/8" X 39 5116' % /2 3/4"
CO 1 24ACC648 0 X 0 0 0 35" 32 5/16" 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8' 17' 17 1/2" 14" 248 291 36 1/8" X 39 5/16' X 35 15/16"
a 24ACC66O I D 40 0 0 35' 45 15/16' 3 7/8' 1/8' 6 9/16" 28 1/16" 9 1/8 2 15/16" 5/8' 17 7/8' 18 5/8' 20 1/4' i 331 372 36 1/8' X 39 5/16" X 49 9/16'
_.
Q NOTES:
4Yp cj 0 - NES 1. ALLOW 30' CLEARANCE TO SERVICE SIDE OF UNIT
Q ,
CI 4D 0 - NO 48' ABOVE UNIT, 6' ON ONE SIDE. 12' ON REMAINING SIDE,
7'' N o ry p AND 24' BETWEEN UNITS FOR PROPER AIRFLOW
N
\ tO
o V 2 NININU5 OUTDOOR OPE RA7ING AM81FNi IN COOLING
XV MODC [5 55'F, MAS. 125°F.
3 SERIES DESIGNATION IS THE 13TH POSITION OF THE
UNIT MODEL NUMBER.
4 CENTER OF GRAVITY ® CD
5 ALL DIMENSIONS ARE IN "INCHES" UNLFSN NOTED. a
A MAIR ri
�w
S0. AIR IN DISCHARGE a)
AIR DISCHARGE --G a
11111111111111111111 _
FIELD
CONTROL 11111111111111111111 ®li IIr`
o\
' III�'
1A
SUPPLY CONN ... '.,'LL__ _ WI RI �7l
B 07/8' HDL I Mw� ' li� 0.IR INS i ' 1 � \ 1l'l I
F
FIELD POWER SUPPLY CONN
-AIR IN
07/8' HOLE WITH
1/D' I,,.KOE oIIII►iuNIIIII N
�� �dr� 01
01
03/8 ' , '' a ° 11II1IIIIIIIIIIII111 --
LIQUID LINE CONN P
1 311rz° 1 ,
{DrVAPOR LINE CONN
. I L J5/16'-tet1
K `A1R IN
/ANNUM
UMT SIZE MOUNTING PAD 03/A" TIEDOWN KNOCKOUTS
DIMENSIONS 12) PLACES
18 ----1 26' X 26'
—�- 24.30 131 1/2" X 31 1/2"
36 THRU 60 35" X 35"
24ACC6 0
vw
co o
A O
v W N
O_
M 43
A
Certified Drawing for 1.5T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
UNIT A BC DE F G °N r !'T
COMMTA5A A II 11r• 11• µ3/16 /5111• I1• SII• 3 13111• 35.5
C$M71111U A 17 113" rr Ill/• 11 51//• 1 1/11• IS• Ill• 3 13115• 51.1
CMR3117A4.3 A 1/Ills• 27 117• I?11l3• 1 11111• I1• Ile /5111• 41.1
CMUMMLLA A IT I17• 22 1211• 70 SllS" l 1/116 11• Ile 315111• ALS
CMI7111AU A 71• 22 1lµ• 10 SI11• S 7/l1• I1 117 ill" S 15111• 51.1
[54144321.33 A 27 I/1S• U 111' IS 1211• 11 l/7• II llr• ill• 5' 51.1
[545411713U A II* 78 1/11• IS 1111• 1 illi• It 1176 Ile 5 15/11• 11.1
C77186SI241U A 74 I/7• tr 11 lir 1 5111• 73' ill• r 1x115• 11.1 H,l46
CMMI?AAU A 24 111{6 71 1111• tI 1411• 1$11/• 75• III• 5 Ile $1.1
u_ iiimimmusennimm
$•
11111•
• 1
I
jI
IOO I.O.
SO(AT C�05050ICRM
610;fit
'I O' 70(41 C505(CTI50
113.
• Q 1-71211•
•
.1
o - �1 �.. Vlllllllllllllll,_ -:=sem
1 1LIgF/MAP
NCI ORISS D 1-1/2•
121 10114 SUES D 11•Mr OOA10
0011. 1-S/t•
I. 715755 1(371541150 IS TIC 14711 50117150 6 5517 MC.IMO
7 All 015(537505 All IA*WNW SUL53 101[0.
Residential Carrier Products Bldr 1.19k Page 8 of 44
24ACC6
Performance-16 Air Conditioner
with Puron® Refrigerant Cam e
1 -1,2to5Tons t,,,,
Product Data
INDUSTRY LEADING
FEATURES/ BENEFITS
Efficiency
• 14- 163 SEER/115-133 EER
• Microtube Tbchnobgy" refrigeration system
• Indoor air quality accessories available
Sound
• Sound level as low as 72 dBA
• Compressor sound blanket standard
Comfort
• System supports Edgee Termidismt'" or standard
thermostat controls
Reliability
• Puron* refrigerant - environmentally sound, won't
deplete the ozone layer and tow lifetime setvice cost
Puron_ Performance' • Scroll compressor
• Internal pressure relief valve
" •r SERIES
• Internal thermal overload
• Filler drier
Carrier's Air Conditioners with name' refrigerant provide a • High and low pressure switches
collection of features unmatched by any other family of
equipment. The 24ACC has bear designed utiizing Carrier's • Balanced refrigeration system for maximum reliability
Puron refrigerant.The environmentally sound refrigerant allows Durability
you to make a responsible decision in the protection of the earth's WeatherArmor" nm
ozone layer. protect package.
This product has been designed and manufactured to meet • Solid,durable sheet metal construction
Energy Star®criteria for energy e0'iciency when matched with • Louvered co0 guard
appropriate cod components. Refer to the combination ratings in • Baked-on,complete outer coverage, powder paint
the Product Data for system combinations that meet Energy Stare
guidelines. Applications
• Long-line-up to 250 feet(76.20 m)total equivalent
NOTE: Ratings contained is this document are subject to length, up to 200 fed (60.96 m) condenser above
diange at any time. Always refer to the AHRI directory evaporator,or up to 80 ft(24.38 m)evaporator above
(www.ahridirectory.org) for the most up-to-date ratings condenser(See Longline Guide for more information.)
information. • Low ambient (down to -20°F/•28.9°C)) with
accessory kit
Residential Carrier Products Bldr 1.19k Page 9 of 44
CNPHP. CNRHP
Evaporator Coil
N Coil — Cased Carrier
Horizontal .
tI_, th
Product Data
This horizontal design N-coil is an evaporator coil designed to
provide the highest standards of reliability and durability.The coils
are available for use in Prone, the environmentally friendly
refrigerant,and R-22 systems.
Both designs have a painted case(taupe metallic)and come with
factory-installed thermostatic expansion valves(TXV).The coils
are offered in different cabinet configurations for use in multiple
installation applications.Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel.The coals are available in sir 024 through 061 (2 to 5
tons).
lln Plated Copper Coils - "T° models are built with special
hairpins, tin plated to resist both general pitting oocrosion and
excessive indoor Formicary Corrosion.(Formicary Corrosion is an
industry phenomenon.)
Aluminum Coils-`2"models are built with aluminum hairpins,
designed to resist both general pitting corrosion and eueesive
indoor-Formicary Corrosion.(Formicary Corrosion is an industry
phenomenon.)
DESIGN FEATURES
Water Management—These coil designs do an excellent job of
water management.The coils are designed to avoid water blow-off
\, into the duets by directing condensate away from the fins and into
the drain pan_ The coil drain pan design provides improved
14.41
condensate removal into the drain. This improves indoor air
qty.
P\ \ / Durable Condensate Pan — Each coal is equipped with a
corrosion-resistant madman drain pan The condensate drain
pan is designed with a clips to help mansemanseproper drainage,
improved moisture removal,and home comfort.
4e improved
Compact Design — The unique design is great for all those
`I 1I; horizontal applications. They are designed for_ either horizontal-tight or horizontal-left furnace At up.The coil is ideally
suited for either attic or crawl space installation.
Brass Insert.—Every condensate pan features two 314-in.female
scsaae threaded brassinsert connections.The unique brass inserts provide
CNPHP /CNRHP for a leak-free condensate line connection to prevent water
damage.
Rehiperani Connections—The coils are provided with proven
sweat connections for leak-free operation maintaining system
reliability.
Burst Presences—These coils meet or exceed burst pressure of
2100 psi which is at least three to five times the pressure they will
see in actual application
Thermostatic Expansion Valves frXV)—An the Carrier coils
have refrigerant-specific factory-installed TXVs.
Tenon Ring—The ring,installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
future service calls. Teflon worts with both Purine and R-22
refrigerants.
Residential Carrier Products Bldr 1.19k Page 10 of 44
2T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
2T
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Guide Specifications
Unit Feature Sheet
Residential Carrier Products Bldr 1.19k Page 11 of 44
Unit Report For 2T
. Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
i
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC Unit Model: CNPH
Unit Size: 2 Tons Unit Size: 2.5 Tons Size 31
Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width: 17 inch
System Parameter
System Quantity: 2
Furnace Type: 59*P5A040E14**10
Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight
Unit Length: 2'9.0" Unit Length: 1' 8.8"
Unit Width: T 6.0" Unit Width: 1'6.0"
Unit Height: 2'9.0" Unit Height: 2' 3.5"
Unit Shipping Weight: 198 lb Unit Shipping Weight: 44 lb
Note:Outdoor unit dimensions may vary depending on the
minor series sent from the factory.
Warranty Information Indoor
CNPH First Year-Parts Only(Standard)
Warranty Information Outdoor
24ACC First Year-Parts Only(Standard)
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ACC624A003 Air Conditioner with Puron Refrigerant 2 Tons Cooling 2
Base Unit
16 SEER @ ARI Conditions 2
Standard 2
Accessories
KSAHS1701AAA Start Assist-Capacitor and Relay 2
KAACH1701AAA Crankcase Heater 2
Base Unit-Indoor
CNPHP3117ACA Cased Horizontal N-Coil Evaporator Coil with Puron 2
Base Unit
Painted 2
17 inch 2
Copper Coil 2
Residential Carrier Products Bldr 1.19k Page 12 of 44
Performance Summary For 2T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
System: 24ACC/CNPH
System Quantity: 2
Altitude: 0.0 ft
Furnace Type: 59*P5A040E14**10
Linear Pipe Length: 0.0 ft
Actual SEER: 15.2
EER @ ARI Conditions: 12.5
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC624A003 Unit Model: CNPHP3117ACA
Unit Size(Nominal): 2 Tons Unit Size(Nominal): 2.5 Tons Size 31
Voltage: 208/230-1-60 V-Ph-Hz Actual Airflow: 800.0 CFM
Clg Ent Air DB Ambient: 95.0 °F Standard Airflow: 800.0 CFM
Total Net Clg Capacity: 24.07 MBH
Net Sensible Clg Capacity: 17.34 MBH
Ent Air DB: 80.00 °F
Ent Air WB: 67.00 °F
Ent Enthalpy: 31.44 BTU/lb
Lvg Air DB: 59.93 °F
Lvg Air WB: 57.57 °F
Lvg Enthalpy: 24.75 BTU/lb
Indoor Unit External Static: 0.50 in wg
Total System Power: 1.93 kW
Outdoor Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz
Fan Motor FLA: 0.70 Amps
MCA: 17.6 Amps
Max Fuse: 25 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA: 13.5 Amps
Compressor LRA: 58.3 Amps
Min Wire Size @ 60C: 14
Min Wire Size @ 75C: 14
Max Length Wire Size @ 60C: 46 ft
Max Length Wire Size @ 75C: 43 ft
Acoustics
Sound Power Levels, db re 10E-12 Watts
Outdoor Unit(dB) Indoor Unit(dB)
DBA Level 74.0 NA
63Hz NA NA
125Hz 52.5 NA
250Hz 59.0 NA
500Hz 65.0 NA
1000Hz 68.0 NA
2000Hz 65.5 NA
4000Hz 59.5 NA
8000Hz 51.5 NA
Sound Message No Indoor sound
data available.
Residential Carrier Products Bldr 1.19k Page 13 of 44
Acoustic Summary For 2T
. Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters:
Tag Name: 2T
Unit Model: 24ACC
Unit Size: 2 Tons
Variations: Standard
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 52.5 59.0 65.0 68.0 65.5 59.5 51.5
A-Weighted Sound Power, dBA 74.0
Indoor Unit Parameters:
Tag Name: 2T
Unit Model: CNPH
Unit Size: 2.5 Tons Size 31
Cabinet Insulation: Painted
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 0.0 0.0 0.0 0.0 _ 0.0 0.0 0.0
A-Weighted Sound Power, dBA 0.0
Residential Carrier Products Bldr 1.19k Page 14 of 44
X
v -0
cn m o
m H
°' DIMENSIONS- ENGLISH o c
C-)
v .
-
ELECTRICAL c
ao UNIT SERIES A B C D E F G K I L M N P OPERATING � ' '
CHARACTERISTICS WEIGHT 1113s1 WEIGHT Ibsl DIMENSIONS IL x W x I-II --.1
CO
2/400618 5 X 0 0 0 25 3/4'' 2811/16' 3 3/4' 3/4' 17/16' 21 1/4' 1 13/16' 2 13/16" 1/2' 131/4' 13 3/4' 12 3/4" 136 163 26 7/8' 4 301/16' X 329/16'
QQ 246[[624 C X 0 0 0 31 3/16" 28 5/16' 3 314" 3/4" 6 9/16" 21 11/16" 9 Il8" 2 13/16" 112' 15 5/8" 15 1/2' 1/" 163 198 32 3/8" X 35 112' X 32 9/16"
0 2467C633 0 X 0 0 0 31 3/16" 32 5/16" 3 3/4' 3/4' 6 9/19' 2/11/16" 9 1/8" 2 13/16" 112" 16 1/2" 15" 14 3/4' 161 204 32 3/8' X 35 1/2' X 35 15/16"
246/0636 D v 0 0 0 35" 28 5/16' 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 18 1/4' 16 7/8' 14" 180 219 136 1/8' X 39 5/16" X 32 9/16'
y 24ACC642 I 0 1 I 0 0 0 35' 39 1/8" 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16' 5/8' 18' 16' 11 I/2' 234 281 I 36 1/8" X 39 5/16' X 42 3/4"
CO 24670648 D X 0 0 0 35" 32 5/16' 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 17' 17 1/2" 14' 248 291 36 1/8" X 39 5/16' X 35 15/16"
15_ 24600660 D X 0 0 0 35" 45 15/16" 3 7/8" 1/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 518" 11 7/8' 18 5/8' 20 1/4" 337 372 36 1/8' X 39 5/16" 6 49 9/16'
$ NOTES:
_ W Q g 0 NOES
�' 0- NO 1 ALLOW 30'CLEARANCE NO SERVICE SIDE OF REMAINING
(D gj W Mp� 48' ABOVE UNIT, 6' ON ONE SIDE, 12' ON REMAINING SIDE.
N N \ AND 24' BETWEEN UNITS FOR PROPER AIRFLOW.
p 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING
um MODE I5 55'F, MAX. 125°F.
3 SERIES DESIGNATION IS THE 13TH POSITION OF THE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY ® /�
. /`)
5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. !'F
A SO. M AIRmom
AIR IN DISCHARGE
AIR DISCHARGE G CD
CL
CD /�-
I oy o py 1 /if
<� ,_` \fir, XIIIIIIIIIIIIIIIIIIIIFIELD CONTROL IIIIIIIIIIIIIIIIIIIII �,. 1 ���1ilillB li
PPLr GoeN �I I aIR]N—� ILI ' ' i
X7/8' aoLE III
IELD POWER SUPPLY CONN.-� ` „,,/
0 7/B' HOLE WITH ���:� AIA IN N
01 ve' 'ru^near ' I111li1N
1;DOID LINE CONN _, .” . IIIIIIIIIIIIIIIIIIII ! . P + ��_ %`
I 4Ws o.
3. I1 *VI? E
G 31/7" I .,,..li- ID Io o 1 1 1 ,
1 7/B"
L
O TJVAPOR LINE CONN 5/16' --
K LAIR 7N
MMMUM
UMT SIZE MOUNTING PAD 031B' 1315086 KNOCKOUTS
DIMENSIONS 12) PLACES
18 _ 26' X 26"
24,30 31 1/2" X 31 1/2'"
36 THRU 60 35" X 35"
13
co 24ACC6 0
co c:' w
cn Vicon
o wa
A g W
Certified Drawing for 2T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
UNIT M A BEDE FG 7M»I!!IT
7.3434711148 A 17 fir 11' II 314. 17111• Ip 521 173,14• 14.1
C713474171U A 17 1I7' 22 7714• 11 3114r 1 7711• 14' 3o4' 11111$' 51.1
(32347 1114(4 A I/1111• 27 I6' 12 1775• T 11111' II' 177' 3 1714' 41.1
(3434741144 A 11 112' 22 1715 II 7114• 5 1,11• 1/' 174' 1 11111• 11.1
(3434627411 A 21• 22 7275. 11 7711 1 7775 II IIP 775' I 13715• 11.1
(3234741144 A 27 1716.7 71115 17 Int II Ill. II lir 115 7' WI
(3234742144 A 21' R 1715 II 4711• I HIP II VY 1,5 1 Noir 71.1
03234742/414 A 27 Ill 25. N 1/1' 4 VIP IV 745 I IIIll• 11.1 25.
(32343171414 5 24 1715 77 ine II I III' 7 1111' N' III' 1701• 74.1
C 7
u MUIIIIIMIIIIIIIIM u
1-770.
'/.11l'
A 4
1Or II.(Tl71(717
1 41 AI[4 (/71[cn71 I
I
11' 11111111M11.11111111111.111 0I11.11 I I 1171LIN
U LIN
NWc711[cn71
•611.. 0
11� i_ Q� � rune
_ __
1114..
Mon
NCI 7141114
0 1 7741/1K4E0 1-117'
- 772 ION MN
D n'Ar OMAN
KO: 1-711'
I.Miff 17114147171 17 TIE 7473 IOSITI01 OT all 11004.IMO
2.4L 1111[711011 IN I7'IICIE7'FILEN 101[0 ,
Residential Carrier Products Bldr 1.19k Page 16 of 44
Guide Specification for 2T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
GUIDE SPECIFICATIONS GENERAL 24ACC
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic
compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on
contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
—Unit will be rated in accordance with the latest edition of ARI Standard 210.
—Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory.
—Unit construction will comply with latest edition of ANSI/ASHRAE and with NEC.
—Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL approval.
—Unit cabinet will be capable of withstanding Federal Test Method Standard No.141(Method6061)500-hrsaltspraytest.
—Air-cooled condenser coils will be leak tested and pressure tested.
—Unit constructed in IS09001 approved facility.
Delivery,Storage,and Handling
—Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations.
Warranty(for inclusion by specifying engineer)
— U.S. and Canada only.
PRODUCTS
AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER 24ACC 1-1/2 TO 5 NOMINAL TONS
Equipment
—Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge Puron (R-410A), and special features required prior to field start-up.
Unit Cabinet
—Unit cabinet, including louvered coil guard, will be constructed of galvanized steel, bonderized, and coated with a powder coat
paint.
Fans
—Condenser fan will be direct-drive propeller type,discharging air upward.
—Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will
be corrosion resistant.
—Fan blades will be statically and dynamically balanced.
—Condenser fan openings will be equipped with coated steel wire safety guards.
Compressor
—Compressor will be hermetically sealed.
—Compressor will be mounted on rubber vibration isolators.
Condenser Coil
—Condensercoilwill be air cooled.
—Coil will be constructed ofaluminum fins mechanically bonded to coppertubeswhich are then cleaned,dehydrated,and sealed.
Refrigeration Components
—Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat
connections, system charge of Puron (R-410A)refrigerant.
—Unit will be equipped with filter drier for Puron refrigerant.
Operating Characteristics
—The capacity of the unit will meet or exceed Btuh at a suction temperature of F. The power consumption at full load
will not exceed kW.
—Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at
conditions of CFM entering air temperature at the evaporator at _F wet bulb and _F dry bulb, and air entering the
unit at _F.
—The system will have a SEER of Btuh/watt or greater at DOE conditions.
Electrical Requirements
—Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within
voltage limits of v to v.
—Unit electrical power will be single point connection.
—Control circuit will be 24v.
Special Features
—Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.
Residential Carrier Products Bldr 1.19k Page 17 of 44
Guide Specification for 2T
_ Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
No Guide Spec available for this Evaporator Coil
Residential Carrier Products Bldr 1.19k Page 18 of 44
24ACC6
Performance-16 Air Conditioner
with Puron® Refrigerant ; Carrier
1 -1:2 to 5 Tons ,r,i
Product Data
- INDUSTRY LEADING
FEATURES/BENEFITS
Efficiency
• 14.163 SEER/113.133 EER
• Microtube Technology'" refrigeration system
• Indoor air quality accessories available
Sound
• Sound level as low as 72 dBA
• Compressor sound blanket standard
Comfort
• System supports Edges Thermidis at'" or standard
thermostat controls
Reliability
• Pirrone refrigerant - environmentally sound, won't
deplete the ozone layer and low lifetime service cost.
Performance • Scroll compressor
• Internal pressure relief valve
SERIES
• Internal thermal overload
• Filter drier
Canter's Air Conditioners with Puron® refrigerant provide a • High and low pressure switches
collection of features unmatched by any other family of
equipment. The 24ACC has bear designed utiizing Carrier's • Balanced refrigeration system for maximum reliability
Puron refrigerant.The environmentally sound refrigerant allows Durability
you to make a responsible decision in the protection of the earth's WeatherArmor protection
ozone layer. package:
This product has been designed and manufactured to meet • Solid,durable sheet metal construction
Energy Stare criteria for energy efficiency when matched with • Louvered coil guard
appropriate col components. Refer to the combination ratings in • Baked-on,complete outer coverage, powder paint
the Product Data for system combinations that meet Energy Stare
guidelines. Applications
• long-line-up to 250 feet(76.20 m)total equivalent
NOTE: Ratings contained In this document are subject to length, up to 200 feet (60.96 m) condenser above
change at any tine. Always refer to the AHRI directory evaporator.or up to 80 ft.(24.38 m)evaporator above
Iwwwahridlaector org) for the most up-to-date ratings condenser(See Longtime Guide for more information.)
Information. • Low ambient (down to -20°F/-28.9°()) with
accessory kit
Residential Carrier Products Bldr 1.19k Page 19 of 44
CNPHR CNRHP
Evaporator Coil
N Coil — Cased
Carrier
Horizontal
t(, thy et,;,tit
Product Data
This horizontal design N-coil is an evaporator coil designed to
provide the highest standards of reliability and durability.The coils
are available for me in Parona, the environmentally friendly
refrigerant,and R-22 systems.
Both designs have a painted case(taupe metallic)and come with
factory-indalled thermostatic expansion valves(TXV).The coils
me offered in different cabinet configurations for use in multiple
installation applications.Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel.The coils are available in sizes 024 through 061 (2 to 5
tons).
Mu Plated Copper Coils - "T° models are built with special
hairpins, tin plated to rent both general pitting corrosion and
excessive indoor Formicary Corrosion.(Formicary Corrosion is an
industry phenomenon.)
Aluminum Coils-`2"models are built with aluminum hairpins,
designed to resist both general pitting corrosion and excessive
indoor-Formicary Corrosion.(Formicary Corrosion is an industry
phenomenon.)
\ DESIGN FEATURES
Water Management—Thele coil designs don excellent job of
water management.The coils are designed to avoid water bow-off
1.%1 into the ducts by directing condensate away from the fins and into
the drain pan_ The coil drain pan design provides improved
condensate removal into the drain. This improves indoor air
quality.
/ P / Durable Condensate Pan — Each coil is equipped with a
f corrosion-resistantcondensate drainpn. The condensatedrain/ panis designedwithacopetohelpensureproperdrainage,1411111111111 kit
` improved Desi n removal and ue a comfort.
\1 �r.�j� Grrtract Dnogn —The migre design is grecs for an those
r 1`. horizontal aht or h ora They zee designed for either
horizoatsi-right m ho®ontsi-Ltfr franaoe fk nqr.The oval is ideally
suited for either attic or crawl space installation.
Brass Inputs—Every condensate pan features two 3f4-in.female
memthreaded braes insert oaawss cliams.The unique brainserts provide
CNPHP/CNRHP for a leak-free condensate line connection to prevent water
damage.
Refrigerant Connections—The coils are provided with proven
sweat connections for leak-free operation maintaining system
reliability.
Bunt Primates—These coils meet or exceed bind pressure of
2100 psi which is at lead three to five times the pleasure they will
see in actual application_
Thermostatic Expansion Valves(TXV)—All the Carrier coils
have refrigerant-specific factory-installed TXVa.
Teflon Ring—The ring,installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
future service calls_ Thilou works with both Puron1 and R-22
refrigerants.
Residential Carrier Products Bldr 1.19k Page 20 of 44
2.5T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
2.5T
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Unit Feature Sheet
Residential Carrier Products Bldr 1.19k Page 21 of 44
Unit Report For 2.5T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
•
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC Unit Model: CNPH
Unit Size: 2.5 Tons Unit Size: 2.5 Tons Size 30
Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width: 17 inch
System Parameter
System Quantity: 1
Furnace Type: 59*P5A060E17**14
Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight
Unit Length: 2'9.0" Unit Length: 1'8.8"
Unit Width: 3' Unit Width: 1'6.0"
Unit Height: 3' Unit Height: 1' 10.0"
Unit Shipping Weight: 204 lb Unit Shipping Weight: 48 lb
Note:Outdoor unit dimensions may vary depending on the
minor series sent from the factory.
Warranty Information Indoor
CNPH First Year-Parts Only(Standard)
Warranty Information Outdoor
24ACC First Year-Parts Only(Standard)
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ACC630A003 Air Conditioner with Puron Refrigerant 2.5 Tons Cooling 1
Base Unit
16 SEER @ ARI Conditions 1
Standard 1
Accessories
KSAHS1701AAA Start Assist-Capacitor and Relay 1
KAACH1701AAA Crankcase Heater 1
Base Unit-Indoor
CNPHP3017ALA Cased Horizontal N-Coil Evaporator Coil with Puron 1
Base Unit
Painted 1
17 inch 1
Aluminum 1
Residential Carrier Products Bldr 1.19k Page 22 of 44
Performance Summary For 2.5T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
System: 24ACC/CNPH
System Quantity: 1
Altitude: 0.0 ft
Furnace Type: 59*P5A060E17**14
Linear Pipe Length: 0.0 ft
Actual SEER: 15.5
EER @ ARI Conditions: 12.7
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC630A003 Unit Model: CNPHP3017ALA
Unit Size(Nominal): 2.5 Tons Unit Size (Nominal): 2.5 Tons Size 30
Voltage: 208/230-1-60 V-Ph-Hz Actual Airflow: 1000.0 CFM
Clg Ent Air DB Ambient: 95.0 °F Standard Airflow: 1000.0 CFM
Total Net Clg Capacity: 27.74 MBH
Net Sensible Clg Capacity: 20.66 MBH
Ent Air DB: 80.00 °F
Ent Air WB: 67.00 °F
Ent Enthalpy: 31.44 BTU/lb
Lvg Air DB: 60.87 °F
Lvg Air WB: 58.38 °F
Lvg Enthalpy: 25.27 BTU/lb
Indoor Unit External Static: 0.50 in wg
Total System Power: 2.19 kW
Outdoor Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz
Fan Motor FLA: 0.70 Amps
MCA: 16.7 Amps
Max Fuse: 25 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA: 12.8 Amps
Compressor LRA: 64.0 Amps
Min Wire Size @ 60C: 14
Min Wire Size @ 75C: 14
Max Length Wire Size @ 60C: 44 ft
Max Length Wire Size @ 75C: 41 ft
Acoustics
Sound Power Levels, db re 10E-12 Watts
Outdoor Unit(dB) Indoor Unit(dB)
DBA Level 74.0 NA
63Hz NA NA
125Hz 56.0 NA
250Hz 58.5 NA
500Hz 66.0 NA
1000Hz 70.5 NA
2000Hz 61.0 NA
4000Hz 58.0 NA
8000Hz 49.0 NA
Sound Message No Indoor sound
data available.
Residential Carrier Products Bldr 1.19k Page 23 of 44
Acoustic Summary For 2.5T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters:
Tag Name: 2.5T
Unit Model: 24ACC
Unit Size: 2.5 Tons
Variations: Standard
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 56.0 58.5 66.0 70.5 61.0 58.0 49.0
A-Weighted Sound Power, dBA 74.0
Indoor Unit Parameters:
Tag Name: 2.5T
Unit Model: CNPH
Unit Size: 2.5 Tons Size 30
Cabinet Insulation: Painted
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
A-Weighted Sound Power, dBA 0.0
Residential Carrier Products Bldr 1.19k Page 24 of 44
uCD, mo
F0: m 0
m .
CCD
U DIMENSIONS— ENGLISH o C
04( 7
v
ELECTRICAL (D
CD UNIT SERIES A B C D E F G K L M N P ST SHPPING SHIPPING a
CHARACTERISTICS WEIGHT (bs) WEIGHT (13sI DIMENSIONS (L x W x M
00
24ACC618 0 X 0 0 0 25 3/4" 28'1/16' 3 3/4' 3/4' 4 7/16" 21 1/4" 1 13/16' 2 13/16" 1/2' 13 1/4' 13 3/4' 12 3/4' 136 163 26 1/8' X 30 1/16" X 32 9/16"
Q 24622624 D X 0 0 0 31 3/16" 28 5/16" 3 3/4' 3/4' 6 9/16" 2/11/16" 9 118" 2 13/16 112" IS 5/8 15 1/2" 14" 163 198 32 3/8" X 35 ill' X 32 9/16"
C)' 24622630 D X 0 0 0 31 3/16" 32 5/16" 3 3/4' 3/4' 6 9/16" 24 11/16" 9 1/8" 2 13/16" 1/2" 76 1/2' 15' 14 3/4" 161 204 32 3/8' X 35 1/2' X 35 15/16"
C
C 24612636 D X 0 I 0 0 35 28 5/16' 3 7/8' 1/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8' 18 1/4' 16 1/8' 14' 180 219 36 1/8' X 39 5/16" X 32 9/16'
CO 24622642 2 1 X 0 I 0 0 35' 39 1/8" 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8' 18' 16' 17 1/2' 234 281 36 1/8' X 39 5/16' X 42 3/4"
Co 24611648 0 X 0 0 0 35" 32 5/16" 3 7/8' 7/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 17" 17 1/2' 14' 248 291 36 1/8" X 39 5/16' X 35 15/16"
a. 24822660 l 0 X 0 0 0 35" 45 15/16' 3 7/8" 7/8" 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 17 7/8" 18 5/8' 20 1/4" 337 372 36 1/8' X 39 5/16" X 49 9/16'
0 j 9 NOTES
-a '
NIS
A$ 0 - NO 1 ALLOW 30'CLEARANCE 10 SERVICE SIDE OF UNIT,
CD �j , 6' ON ONE SIDES 12' ON REMAINING SIDE.
7-- N g N s AND 24' BETWEEN UNITS FOR PROPER AIRFLOW.
N pm 2. MINIMUM OUTDOOR OPERATING AMOIENT IN COOLING
.. 400E 55 55°F, MAX. 125°F.
3 SERIES DESIGNATION IS THE 7318 POSITION OF THE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY ® CD
5 ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED.
A --I 1- M
S0. AIR IN AIR CD
DISCHARGE
AIR DISCHARGE
_ G - a
�11.1�1.1111 D I 1 �, N \ =.
FIELD CONTROL IIIIIIIIIIIIIIIIIIII ' j 1mfi
SUPPLY CONN. ...I� 0
B 01/8' FOL, jIll
Irr � � 1' ��i N-,-AIRINIMS LIDUIDINN _ (01.0:� , - E':.i...p o10 — — o I• l
I A
-
B"
L- I
0 n VAPOR LI81 CONN 5/16'y
I
K LAIR IN
MINIMUM
UNIT SIZE MOUNTING PAD, 03/8' 11EDOWN KNOCKOUTS
DIMENSIONS 121 PLACES
18 26' X 26
24.30 31 1/2" X 31 1/2"
36 THRU 60 35" X 35"
24ACC6
co-0 0
co ca
N O O
A
O 1 01 W N
A E W
Certified Drawing for 2.5T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
LI 1
UMIT A BCDEF G PIPPO n
CnP2111ALA A 1t Ilr• 11• ' II 111• 1 Sill• 11• 111• 1 731114 11.1
CPP/II/AU A 1/llr• 22 lilt" 11 3il5' 11I Il' It" 311• 1 731116 11.1
C1/111117LLA A 1//111• 21 IR• I?vet" 7 11I11• It" /14" 1 int" 41.1
CVM311IAU A It lit' 27 1111• 11 Sill. I/I11' 1/• 111• 7 13111• II$
0111221115 A 21' 211111' II VIP 17111' 11 112. 111• 11,111• 11.1
CP111111AU A 21 Mr 111/1• 15 111/• 11112• 11 lit" Ill• 1• 11.1
CMYNZIAU A Al" H 1I1/• II WV I till' 11 I/2• Ill" 113111• 11.1
C1111111241LA A 21 1I2• Ti" 74 Mr 1 Til/• 21• Ill" 1 1311t" 11.1 20•CMR/124141 A 21 1111• 21,i11• 1l 1i11• I S11/• 21• 111• r 1i1• IN I
C 7
La MIIMIIIIIIINNIMMO u
til"
1.•711.
■ I
JI
![r=MI
1412
III s125�wi"crtaSJ/I•r.1.
11 11 110111 LIN
AUT CO•ITCrtp
rilL 0
OM__-MT.!al • ii, ` : _ 1111•
•
pp[E�� MI !�►
.�. .d111 111 OWE
1 102IIIA S 8 ' !II.IMMpm 1-1/2•
D II'VT PAM
loll. I-UI"
I.StIllS l(110U22M 35 THE IAN/OSITI01 OF$117 10111 111/EI II
2.All OPIUM VT 11"DPW PLEAS WED ,
Residential Carrier Products Bldr 1.19k Page 26 of 44
24ACC6
Performance"'16 Air Conditioner
with Puron® Refrigerant Carrler i
1 -1:2 to 5 Tons
Product Data
INDUSTRY LEADING
FEATURES/ BENEFITS
Efficiency
• 14-16.5 SEER 1113-133EER
• Microlube Technology"' refrigeration system
• Indoor air quality accessories available
Sound
• Sound level as low as 72 dBA
• Compressor sound blanket standard
Comfort
• System supports Edgee Thermidistat" or standard
thermostat controls
Reliability
• Puron refrigerant - environmentally sound, won't
deplete the ozone layer and low lifetime scrvee cast.
Puron_ Performance • Scrod compressor
• Interval pressure relief valve
SERIES
• Internal thermal overload
• Filter drier
Carrier's Air Conditioners with Pirrone refrigerant provide a • High and low pressure switches
collection of features unmatched by any other family of
equipment. The 24ACC has been designed utilizing Carrier's • Balanced refrigeration system for maximum reliability
Puron refrigerant.The environmentally sound refrigerant allows Durability
you to make a responsible decision in the protection of the earth's WeadrerArmor e"protection package
ozone layer.
This product has been designed and manufactured to meet • Solid,durable sheet metal construction
Energy Stare criteria for energy efficiency when matched with • Louvered coil guard
appropriate cod components. Refer to the combination ratings in • Baked-on,complete outer coverage, powder paint
the Product Data for system combinations that meet Energy Stare
guidelines. Applications
• Long-Parc-up to 250 feet(76.20 m)total equivalent
NOTE: Ratings contained in this document are subject to length, up to 200 feet (60.96 m) condenser above
change at any time. Always refer to the AHRI directory evaporabr,or up to 80 ft.(24.38 m)evaporator above
(www.ahrNhectory.org) for the most up-to-dale ratings condenser(See Longline Guide for more information.)
Information. • Low anbiert (down to -20°F/-28.9°C)) with
amatory kit
Residential Carrier Products Bldr 1.19k Page 27 of 44
CNPHRCNRHP
Evaporator Coil
N Coil — Cased
Carrier
Horizontal
t:,
Product Data
This horizontal design N-coil is an evaporator coil designed to
provide the highest standards of reliability and durability.The cols
are available for use in Perone, the envaomneutally friendly
refrigerant,and R-22 systems.
Both designs have a painted case(taupe metallic)and come with
factory-installed thermostatic ern valves(TXV).The coils
are offered in different cabinet inanimation'for use in multiple
installation applications.Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel.The cols are available in aims 024 through 061 (2 to 5
tons).
Ten Plated Copper Coils - "r models are built with special
hairpins, tin plated to twin both general pitting corrosion and
excessive indoor Formicary Corrosion-(Fonnicary Corrosion is an
industry phenomenon.)
Aluminum Coils-"L"modeh are built with ahrmiauin hairpins,
designed to resist both general pitting corrosion and excessive
indoor-Formicary Corrosion.(Formicary Corrosion is an industry
phenomenon.)
DESIGN FEATURES
Rater Maras—Ther coil designs do an excellent job of
water management.The coils s adesigned grrd to avoid water blow-off
into the ducts by directing condensate away from the fins and into
the drain pan. The coil drain pan design provides improved
condensate removal into the drain. This improves indoor air
qty.
/' - Durable Condensate Pan — Each coil is equipped with a
corrosion-resistant condensate dram pan. The condensate drain
\ pan designed with a elope to help gimme proper drainage,
� improved moisture removal,and home comfort.
`I , Compact Daodra — The unique design is great for all those
006,4 1 I: hosizoatal applications. They are designed for either
horizontal-right or ho®ontal-left furnace fit up.The coal is ideally
suited for either attic or crawl space installation.
Bras Inserts—Every condensate pan features two 3/4-in.female
threaded braes insert connections.The unique brass inserts provide
CNPHP/CNRHP for a leak-free condensate line connection to prevent water
damage.
Refrigerant Connections—The earls are provided with proven
sweat connections for leak-free operation maintaining system
Burst Pressures—These coils meet or exceed burst preeeure of
2100 psi which is at least three to five times the pressure they will
see in actual application.
Thermostatic Expansion Valves(TXV)—All the Carrier coils
have refrigerant-specific factory-installed TXVs.
Tenon Ring—The ring,installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
future service calls. Teflon works with both Prune and R-22
refrigerants.
Residential Carrier Products Bldr 1.19k Page 28 of 44
3T
_ Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
3T
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Unit Feature Sheet
Residential Carrier Products Bldr 1.19k Page 29 of 44
Unit Report For 3T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC Unit Model: CNPH
Unit Size: 3 Tons Unit Size: 3 Tons
Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width: 17 inch
System Parameter
System Quantity: 1
Furnace Type: 59*P5A060E17**14
Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight
Unit Length: 3' Unit Length: 1'8.8"
Unit Width: 3'3.0" Unit Width: 1'6.0"
Unit Height: 2'9.0" Unit Height: 1' 10.0"
Unit Shipping Weight: 219 lb Unit Shipping Weight: 48 lb
Note:Outdoor unit dimensions may vary depending on the
minor series sent from the factory.
Warranty Information Indoor
CNPH First Year-Parts Only(Standard)
Warranty Information Outdoor
24ACC First Year-Parts Only(Standard)
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ACC636A003 Air Conditioner with Puron Refrigerant 3 Tons Cooling 1
Base Unit
16 SEER @ ARI Conditions 1
Standard 1
Accessories
KSAHS1701AAA Start Assist-Capacitor and Relay 1
KAACH1701AAA Crankcase Heater 1
Base Unit-Indoor
CNPHP3617ALA Cased Horizontal N-Coil Evaporator Coil with Puron 1
Base Unit
Painted 1
17 inch 1
Aluminum 1
Residential Carrier Products Bldr 1.19k Page 30 of 44
Performance Summary For 3T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
System: 24ACC/CNPH
System Quantity: 1
Altitude: 0.0 ft
Furnace Type: 59*P5A060E17**14
Linear Pipe Length: 0.0 ft
Actual SEER: 15.0
EER @ ARI Conditions: 12.3
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC636A003 Unit Model: CNPHP3617ALA
Unit Size (Nominal): 3 Tons Unit Size(Nominal): 3 Tons
Voltage: 208/230-1-60 V-Ph-Hz Actual Airflow: 1200.0 CFM
Clg Ent Air DB Ambient: 95.0 °F Standard Airflow: 1200.0 CFM
Total Net Clg Capacity: 32.68 MBH
Net Sensible Clg Capacity: 24.13 MBH
Ent Air DB: 80.00 °F
Ent Air WB: 67.00 °F
Ent Enthalpy: 31.44 BTU/lb
Lvg Air DB: 61.38 °F
Lvg Air WB: 58.55 °F
Lvg Enthalpy: 25.39 BTU/lb
Indoor Unit External Static: 0.50 in wg
Total System Power: 2.78 kW
Outdoor Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz
Fan Motor FLA: 0.50 Amps
MCA: 18.1 Amps
Max Fuse: 30 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA: 14.1 Amps
Compressor LRA: 77.0 Amps
Min Wire Size@60C: 12
Min Wire Size @ 75C: 12
Max Length Wire Size @ 60C: 57 ft
Max Length Wire Size @ 75C: 54 ft
Acoustics
Sound Power Levels, db re 10E-12 Watts
Outdoor Unit(dB) Indoor Unit(dB)
DBA Level 74.0 NA
63Hz NA NA
125Hz 54.5 NA
250Hz 62.0 NA
500Hz 66.0 NA
1000Hz 69.5 NA
2000Hz 66.5 NA
4000Hz 65.0 NA
- 8000Hz 60.0 NA
Sound Message No Indoor sound
data available.
Residential Carrier Products Bldr 1.19k Page 31 of 44
Acoustic Summary For 3T
. Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters:
Tag Name: 3T
Unit Model: 24ACC
Unit Size: 3 Tons
Variations: Standard
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 54.5 62.0 66.0 69.5 66.5 65.0 60.0
A-Weighted Sound Power, dBA 74.0
Indoor Unit Parameters:
Tag Name: 3T
Unit Model: CNPH
Unit Size: 3 Tons
Cabinet Insulation: Painted
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
A-Weighted Sound Power, dBA 0.0
Residential Carrier Products Bldr 1.19k Page 32 of 44
PO v-0
CD N U.cn
N CDO
DIMENSIONS- ENGLISH •co
I ELECTRICAL IOPERATING SHPPING SHIPPING a
CD UNT SERIES A B C D E F G K L M N P
CHARACTERISTICS _ WEIGHT (bs) WEIGHT Ibsl DIMENSIONS (L x W x M
CO
248CC618 I 0 1 X 0 0 0 25 3/428 11/16' 3 3/4' 3/4' 4 7/16" 21 1/4" 1 13/16' 2 13/16" 1/2' 13 1/4" 13 3/4' 12 3/4' 136 163 26 7/8' X 36 1/16" X 32 9/16'
6 24ACC624 D X 0 0 0 31 3/16" 28 5/16" 3 3/4' 3/4" 6 9/16" 24 11/16" 9 1/8" 2 13/16" 1/2' 15 5/8" 15 1/2' 14" 163 198 32 3/8" X 35 1/2' X 32 9/16"
Q 2467(630 0 X 0 0 0 31 3/16' 32 5/16" 3 3/4' 3/4' 6 9/16" 24 11/16" 9 1/8" 2 13/16" 112" 16 1/2" 75" 14 3/4' 761 204 32 3/8' X 35 112' X 35 15/16"
C
n 2487(636 I 0 X 0 0 0 35' 28 5/16' 3 7/8' T/B' 6 9/16" 28 1/16" 9 I/8" 2 15/16" 518" 18 1/4' 16 7/8' 14' 18D 219 36 1/8' X 39 5/16" X 32 9/16'
�1 I 246(7642 � C X 0 D 0 35' 39 119" 3 7/8' T/B' 6 9/16" 28 7116" 9 118" 2 15/16" 518' 18' 16' 17 7/2' 234 281 36 1/8" X 39 5/16' X 42 3/4"
CO I 246(7648 7 X 0 0 0 35" 32 5/16" 3 7/8' 1/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 11' 17 1/2" 14' 248 291 36 1/8" X 39 5/16' X 35 15/16"
i- 24ACC660 0 X 0 0 0 35' 45 15/16" 3 7/8" 1/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 17 7/8" 18 5/8" 20 I/4" 337 372 36 1/8' X 39 5/16" X 49 9/16"
pt� NOTES
t$ I l') 44 1 0- NO 1. ALLOW 30' CLEARANCE TO SERVICE SIDE OF UNIT,
(O M 48' ABOVE UNI1, 6' ON ONE SIDE. 12' ON REMAINING SIDE,
7- ClCo N p AND 24' BETWEEN UNITS FOR PROPER AIRFLOW.
N tV0
2°3 2, MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING
MODE IS 55°F, MAX. 125°F.
3 SERIES DESIGNATION I5 THE 13TH POSITION OF THE
UNIT MODEL NUMBER. ^
4. CENTER OF GRAVITY S. ,•
CD
5 ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED, P.
A S0 y M AIRI In o scHAAGE / %
\\\ AIR`\\DISCHARGE G I /,fir
11111111111111111M DI I / _ •
FIELD CONTROL IIIIIIIIIIIIIIIIIIII �, �\� _1 co
SLIPPY CONN !
07re' NDLE 1111 '�7 � AIR IN-- 1 � ���I �� F O
B •1��11 ) .y,�] �' �.�' : �// -8------AIR IN
FIELD POWER SUPPLY CONN. I
148' HOLE WITH V „ N W
03/8 ^ t•01 1/P' °OWL' * 111111111111 I II
,j\I �`� �/�,',
IDUID LINE 7048 , _ o ` IIIIIIIIIIIIIIIIIIII l P /�-�.`-=
\ E
C 312• i�... oT uru , w� ,�
dtivaF+1 1 7/8'
} L-
0 rvAPOR LINE CONN 6'
— K LAIR IN
MNNAUM
UST SIZE MOUNTING PAD 03/8' TIEDOWN KNOCKOUTS
DIMENSIONS /21 PLACES
8 26' X 26"
24,30 31 1/2" X 31 1/2"
36 1HRU 60 35" X 35"
co 24ACC6 O
A
W O
O W IV
�.
-.0 O
A 4,
A K
Certified Drawing for 3T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
UNIT x A B C D E F 6 c",wp o
CVMPIT TAU A IT 1116 116 11 SIP 1 STP IP SII• 7 13T66 A.1
CPN7111I1/ 1 I1 111• 25 11161 11 WV 11/1S• IS• U11 1 111166 51./
Cww/111/U I II ITP 57 111• II 15151 /11111• IP 11P /WV 11.1
C1/N311(/L1 6 11 1116 U 11111 11 STI• 1 1111' IV 3111 1 11111' 11.1
CAN111uL1 1 511 11111/1 1171111 11111• 11111• III• 111111• II.1
CM111111/U A ZI 1/IS1 Al III" If 11111 11 111' 11 1111 (/I1 11 30.1
CINY11111U A 11• H 1111• II 11111 I 1/111 11 IIA• IIP 1 111111 11.1
C11W61111U A 51 1111 h1 11 1111 I STIP 11' 1111 3 171116 01.1 „.
CMMIIU(I I N 1/161 11171• 11 ISI1' 1 SII/' 171 111• 1 lir 51,1
C 7
La u
I
Lir
II-11P
A 1
6,I 0P 7.1.
tICTI05 LII(
sIGT(In[cTla
II
1IT :. 1
T,- • Mis I'Til
• �I' n: 1-i
loillommiNnMEI 1 !l1•K111E0 WIN
01E1 0141116 S I-1/r
Ill 1011 SIM
D 11 NT Ma
WI' ,-S/r
1.115(11 1(IIOUTIOS IS 11E 1011 10111/011 OF INIl WEL FIE[ II
2 ILL 0115/5/051 YE 10•ISCIES•SEEDS 10EE0 ,
Residential Carrier Products Bldr 1.19k Page 34 of 44
24ACC6
Performance "16 Air Conditioner
with Puron® Refrigerant Carrier)
1 -1/2to5Tons
Product Data
INDUSTRY LEADING
FEATURES/BENEFITS
Efficiency
• 14- 163 SEER/115-133 EER
• Micron/be T>chirology" refrigeration system
• Indoor air quality accessories available
Sound
• Sound level as low as 72 dBA
• Compressor sound blanket standard
Comfort
• System supports Edge* Thennidistat" or standard
thermostat controls
Reliability
• Puron• refrigerant - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Puna_ Performance •• Scroll compressor
• Internal pressure relief valve
SERIES
• Internal thermal overload
• Flier drier
Carrier's Air Conditioners with Puron* refrigerant provide a • High and low pressure switches
collection of features unmatched by any other family of
equipment. The 24ACC has been designed utilizing Canter's • Balanced refrigeration system for maximum reliability
Puron refrigerant.The environmentally sound refrigerant allows Durability
you to make a responsible decision in the protection of to earth's Weal erArmor"protection package:
ozone layer.
This product has been designed and manufactured to meet • Solid,durable sheet metal construction
Energy Sure'criteria for energy efficiency when matched with • Louvered coil guard
appropriate coil components. Refer to the combination ratings in • Baked-on,complete outer coverage, powder paint
the Product Data for system combinations that meet Energy Stars
g,uidelkies, Applications
• Long-line-up to 250 feet(76.20 m)total equivalent
NOTE: Ratings contained in this document are suliect to length, up to 200 feet (60.96 m) condenser above
change at any time. Always refer to the AHRI directory evaporator,or up to 80 ft.(24.38 m)evaporator above
(www.abridhectory.org) for the most up-to-dale ratings condenser(See Longline Guide for more information.)
Information. • Low ambient (down to -20"F/-28.9°C)) with
accessory kit
Residential Carrier Products Bldr 1.19k Page 35 of 44
CNPHP. CNRHP
Evaporator Coil
N Coil — Cased "~
Carrier
Horizontal �1 :
Prod uct Data
This horizontal design N-coil is an evaporator coil designed to
provide the highest standards of reliability and durability.The coils
are available for use in Perone, the environmentally friendly
refrigerant,and R-22 syatema
Both designs have a painted case(taupe metallic)and come with
factory-installed thermostatic expansion valves(rX ).The coils
are offered in different cabinet configurations for use in multiple
installation applications.Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel.The coils are available in size 024 through 061 (2 to 5
tons).
lin Plated Copper Coils - "1'" models are built with special
hairpins, tin plated to resist both general pitting cosroion and
excessive indoor Formicary Corrosion..(Formicary Caorroion is an
industry phenomenon.)
Aluminum toils-"L"models are built with aluminum hairpins,
designed to resist both general pitting corrosion and excessive
indoor-Formicary Corrosion.(Formicary Corrosion is an industry
phenomenon.)
DESIGN FEATURES
'atm Manamanent—These coil deigns do an excellent job of
water management-The coals are designed to avoid water blow-off
into the ducts by directing condensate spay from the fins and into
IIIthe drain pan. The coil drain pan design provides improved
condensate removal into the drain. Thism indoor air
quality.
/ Durable Condensate Paw — Eath coil is equipped with a
0004A msroion-resistant oondeosate drain pan. The condensate drain
0 \ / pm is designed with a slope to help ensure proper drainage,
`I improved moistu a removal,and home comfort.♦ �e Compact Deign —The unique design is great for all those
0011.7 horizontal applications. They are designed for either
horizontal-right or horizontal-left furnace fit up.The coil is ideally
suited for either attic or crawl space installation.
Bras Inserts—Every condensate pan features two 3/4-in.female
AMOCOthreaded brass insert connections.The unique brass inserts provide
CNPHP/CNRHP for a leak-free condensate line connection to prevent water
damage.
Refrigerant Connections—The coils are provided with proven
sweat connections for leak-free operation maintaining system
reliability.
Burst Pressures—Ties coils meet or exceed burst pressure of
2100 psi which is at hart three to five times the pressure they will
see in actual application_
Thermostatic Expansion Valves(TXV)—can the Carrier coils
have refrigerant-specific factory-installed DEW
Teflon Rist—The ring,installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
future service calls. Tifton works with both Purone and R-22
refrigerants.
Residential Carrier Products Bldr 1.19k Page 36 of 44
4T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
4T
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Unit Feature Sheet
Residential Carrier Products Bldr 1.19k Page 37 of 44
Unit Report For 4T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
,Mian
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC Unit Model: CNPH
Unit Size: 4 Tons Unit Size: 4 Tons
Voltage: 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width: 21 inch
System Parameter
System Quantity: 2
Furnace Type: 59*N*A080V21**20
Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight
Unit Length: 3' Unit Length: 1'8.8"
Unit Width: 3'3.0" Unit Width: 1'9.0"
Unit Height: 3' Unit Height: 2'4.0"
Unit Shipping Weight: 291 lb Unit Shipping Weight: 68 lb
Note:Outdoor unit dimensions may vary depending on the
minor series sent from the factory.
Warranty Information Indoor
CNPH First Year-Parts Only(Standard)
Warranty Information Outdoor
24ACC First Year-Parts Only(Standard)
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ACC648A003 Air Conditioner with Puron Refrigerant 4 Tons Cooling 2
Base Unit
16 SEER @ ARI Conditions 2
Standard 2
Accessories
KSAHS1701AAA Start Assist-Capacitor and Relay 2
Base Unit-Indoor
CNPHP4821ALA Cased Horizontal N-Coil Evaporator Coil with Puron 2
Base Unit
Painted 2
21 inch 2
Aluminum 2
Residential Carrier Products Bldr 1.19k Page 38 of 44
Performance Summary For 4T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
System: 24ACC/CNPH
System Quantity: 2
Altitude: 0.0 ft
Furnace Type: 59*N*A080V21**20
Linear Pipe Length: 0.0 ft
Actual SEER: 15.0
EER @ ARI Conditions: 12.7
Outdoor Unit Parameters Indoor Unit Parameters
Unit Quantity: 1 Unit Quantity: 1
Unit Model: 24ACC648A003 Unit Model: CNPHP4821ALA
Unit Size(Nominal): 4 Tons Unit Size(Nominal): 4 Tons
Voltage: 208/230-1-60 V-Ph-Hz Actual Airflow: 1600.0 CFM
Clg Ent Air DB Ambient: 95.0 °F Standard Airflow: 1600.0 CFM
Total Net Clg Capacity: 44.64 MBH
Net Sensible Clg Capacity: 33.79 MBH
Ent Air DB: 80.00 °F
Ent Air WB: 67.00 °F
Ent Enthalpy: 31.44 BTU/lb
Lvg Air DB: 60.44 °F
Lvg Air WB: 58.32 °F
Lvg Enthalpy: 25.24 BTU/lb
Indoor Unit External Static: 0.50 in wg
Total System Power: 3.50 kW
Outdoor Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz
Fan Motor FLA: 1.20 Amps
MCA: 26.1 Amps
Max Fuse: 40 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA: 19.9 Amps
Compressor LRA: 109.0 Amps
Min Wire Size @ 60C: 10
Min Wire Size @ 75C: 10
Max Length Wire Size @ 60C: 70 ft
Max Length Wire Size @ 75C: 67 ft
Acoustics
Sound Power Levels, db re 10E-12 Watts
Outdoor Unit(dB) Indoor Unit(dB)
DBA Level 74.0 NA
63Hz NA NA
125Hz 59.0 NA
250Hz 63.5 NA
500Hz 65.5 NA
1000Hz 69.0 NA
2000Hz 63.5 NA
4000Hz 59.0 NA
8000Hz 53.0 NA
- Sound Message No Indoor sound
data available.
Residential Carrier Products Bldr 1.19k Page 39 of 44
Acoustic Summary For 4T
Project: —Untitled78 03/05/2013
Prepared By: 04:53PM
Outdoor Unit Parameters:
Tag Name: 4T
Unit Model: 24ACC
Unit Size: 4 Tons
Variations: Standard
Octave Band Center Frequency, Hz 63 125 250 _ 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 59.0 63.5 65.5 69.0 63.5 59.0 53.0
A-Weighted Sound Power, dBA 74.0
Indoor Unit Parameters:
Tag Name: 4T
Unit Model: CNPH
Unit Size: 4 Tons
Cabinet Insulation: Painted
Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
A-Weighted Sound Power, dBA 0.0
Residential Carrier Products Bldr 1.19k Page 40 of 44
CD8 o
w
o a:i (D.
o
CD '•
v DIMENSIONS- ENGLISH W
d
c,
_
ELECTRICAL I OPERATING SHIPPING I SHIPPING a
N LI SERBS A B C I D E F G K L M N P
CHARACTERISTICS WEIGHT (bs1 WEIGHT (bs) DIMENSIONS (L x W x HI CO
24ACC618 D X 0 0 0 125 3/4" 28 11/16" _3 3/4' 3/4' 4 7/16" 21 1/4" 1 13/16" 2 13/16" 1/2" 13 1/4' 13 3/4' 12 3/4' 136 163 26 1/8' X 3D 1/16' X 32 9/16"
Q 24ACC624 0 X 0 0 0 31 3/16' 28 5/16" 3 3/4" 3/4" 6 9/16' 24 11/16" 9 1/8' 2 13/16" 1/2" 15 5/8" 15 1/2" 14" 163 198 32 3/8" X 35 1/2' X 32 9/16'
CL __
0 X 0 0 0 31 3/16" 32 5/16' 3 3/4" 3/4" 6 9/16" 24 11/16" 9 1/8" 2 13/16" 1/2" 16 1/2' 15" 14 3/4" 167 204 32 3/8' X 35 1/2' X 35 15116"
C
n 24400636 0 X 0 0 0 I 35' 28 5/16' 3 7/8' 1/8' 6 9116" 28 7116" 9 1/8" 2 15/16" 5/8' 18 1/4' 16 1/8' 14" 18D 219 36 1/8' X 39 5116" X 32 9/16'
CO 246016e2 0 X 0 � 0 0 35' 39 t/B" 3 7/8' 1/8' 6 9/16" 28 In 6" 9 1/8" 2 15n 6" 5/8' 18' 16' 17 1/2' 234 281 36 1/8" x 39 5116' X 42 3/4"
CO 24401648 0 X 0 0 0 I 35" 32 5/16" 3 7/8' 1/8' 6 9/16" 28 7/16" 9 1/8" 2 15/16" 5/8" 17' 17 1/2" 14" 248 291 36 1/8" X 39 5/16' X 35 15/16"
5- 24601660 0 X 0 0 0 35" 45 15/16' 3 7/8' 1/8" 6 9/16" 28 1/16" 9 1/8" 2 15/16" 518" 17 7/8' 18 5/8" 20 1/4" 337 372 36 1/8' X 39 5/16" X 49 9/16"
q NOTES'
Cfl o t ("yl i�y 0 - NO 1. ALLOW 30'CLEARANCE TO SERVICE SIDE OF UNIT,
f.A ` o 48' ABOVE UNIT, 6' ON ONE SIDE, 12' ON REMAINING SIDE.
T- N g N VAND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
" m
p 2. MINIMUM OUTDOORMAX1 OPERATING AMBIENT IN COOLING
N NODE 15 55°F, NX. 125°F.
3 SERIES DESIGNATION I5 THE 131H POSITION OF THE
UNIT MODEL NUMBER. ^
4 CENTER OF GRAVITY S
5 ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED.
r~ Aso. N AIR
1 AIRI IN DISCHARGE �w
AIA DISCHARGE I G--II ,v
7w v
CD CI)
e, o Qo �� 774,
1-
11111111111111NIIII /., ,'%
ISI7- .,''.\ ''''', 1
FIELD CONTROL
IIIIIIIIIIIIIIIIIIII IIS I 11 �1 t() .... _�...I.:_ mh
SUPPLY CONN.
B B' Ho.. tom
AIa IN� gad
ml
FIELD POWER SUPPLY CONN. •GT1 1/81 1,014CLT * 114111.11 A , � / F -AIR IN
7/8' HOLE WITH / // N
uou1D LIN �oeN • P 4,���c�� �'
:, _
, o IIll111D , *** -_ / E
rt r
•
�DvAFOA LINE CONN. L��5/16'- 1
K LAIR IN
MNIMUM
UNT SIZE MOUNTING PAD 1 153/8' TIEDOWN 860180215
DIMENSIONS /21 PLACES
_ 16 26' X 26"
I
24.30 31 1/2" X 31 1/2"
36 THEM 60 35" X 35"
so 24ACC6 o
co co
A A 0
•• CT
O t4 NO
A K co
Certified Drawing for 4T
Project: -Untitled78 03/05/2013
Prepared By: 04:53PM
WRIT ....2 A B C D E F G 311;�~WI
CAM1111AU 1 17 1/P 1P 11!1P I sits. 1t• Ill I iris. 13.3
CAM A 1I Ill* it 1/11• IS DIV 17/11' I/• 111• 111111• 31.1
CIPA1111ALA A I1 3111' 27 lir I?lot. T tilt{' t•• 1l1• 1 1111' 11.1
010114111IALA ■ 11 111' 22 1/71' 10 1111• 17/II' 1/' 111• 1 13/I1. AIL
C011lI11AU A 211 22 1/11' 13 SlIe 17/11' 11 UV ill• 3 me 51.1
CAA1111ALA A n InS• SI Iii' 1S kW 11 vi' 1i iq' 7/1• W. S1.1
CAAII2UU 4 21• a Int• Il Int' I LII' It 1i' I/P 1 Iln1• 11.1
C11M•IZIIU A 24 111- tP 14 sir i 3/II' 11• 71P 1 late 11.1 „-
CAP.1}ULA A 24 3/111• 21 1115' II 1111' 1 S/1/• 23' Ur3 71P 61,1
C n
La 111111M111118 u
u
L lir
1rin•
■ I
IIf I.I. 11
ih
KTi01 lel
311Ir COM[CfOI
i! .
•i .cna ► I
_ _ nlllrP
•
Mal ����a..�..n:_s�i
0 NMI 111 !IP RIIKO wan
17 IOW lets
• D /l•MT PAIN
malt: 1-5/l•
1.571171 ASIWARIM 25 TIE 11711 POSITION M 1111 0011111•!e 1
7 ALL IM13IW3 AK U'I61E1.111E1i 101E0. ,
Residential Carrier Products Bldr 1.19k Page 42 of 44
24ACC6
Performance''16 Air Conditioner ,�-
with Puron® Refrigerant Carrie—r-
1 —1,2 to 5 Tons
arrier1 -1,2to5Tons
r,:; ....G_:
Product Data
INDUSTRY LEADING
FEATURES/BENEFITS
Efficiency
• 14-163 SEER/115-135EER
• Microtube Technology" refrigeration system
• Indoor air quality accessories available
Sound
• Sound level as low as 72 dBA
• Compressor sound blanket standard
Comfort
• System supports Edgee Thennidismt" or standard
thermostat controls
Reliability
• Puron refrigerant - environmentally sound, won't
deplete the ozone layer and low lifetime servo cost
Puron Performance • ScroO compressor
• internal pressure relief valve
SERIES
• internal thermal overload
• Filter drier
Carrier's Air Conditioners with Purone refrigerant provide a • High and low pressure switches
collection of features unmatched by any other family of
equipment. The 24ACC has been designed utilizing Carrier's • Balanced refrigeration system for maximum reliability
Puron refrigerant.The environmentally sound refrigerant allows Durability
you to make a responsible decision in the prosection of die earth's WeadurArtnor"protection package
ozone layer.
This product has been designed and manufactured to meet • Solid,durable sheet mewl construction
Energy Stare criteria for energy efficiency when matched with • Louvered cod guard
appropriate ma components. Refer to the combination ratings in • Baked-on,complete outer coverage, powder paint
the Product Data for system combinations that meet Energy Stare
guidelines. Applications
• Long-lie-up to 250 feet(76.20 m)total equivalent
NOTE: Ratiatgs contained in this document are subject to length, up to 200 fed (60.96 m) condenser above
change at any time. Always refer to the AHRI directory evaporator,or up to 80 ft(24.38 m)evaporator above
(www.ahridlrectory.org) for the most up-to-date ratings condenser(See Longline Guide for more information.)
infornatim, • Low ambient (down to -20°F/-28.9°C)) with
accessory kit
Residential Carrier Products Bldr 1.19k Page 43 of 44
CNPHR CNRHP
Evaporator Coil
N Coil — Cased Carrier
Horizontal
Product Data
This horizontal design N-coil;s an evaporator coil designed to
provide the highest standards of reliability and durability.The coils
are available for me in Pwons, the envi oamentally friendly
refrigerant,and R-22 systems.
Both designs have a painted case(taupe metaihc)and court with
factory-innalled thermostatic expansion valves(TXV).The coils
are offered in different cabinet configurations for use in multiple
installation applications.Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel The coils are available in sizes 024 through 061 (2 to 5
tom).
Tin Plated Copper Coils - "T" modes are built with special
hairpins, ten plated to resist both general pitting corrosion and
excessive indoor Fanniary Corrosion.(Formicary Corrosion is an
industry Phenomenon.)
Aluminum Coils-"L"models are built with ahmumun hairpins,
designed to resist both general pitting corrosion and excessive
indoor-Formicary Corrosion.(Formicary Condon is m industry
phenomenon.)
DESIGN FEAT[TRES
Water Menareeerrt—These coil designs do an excellent job of
water management.The coils are designed to avoid water blow-off
. \, into the duds by directing condensate away from the fins and into
the drain pan. The coil drain pea deeign provides improved
condensate removal into the drain. This improves indoor air
quality.
111
/ Durable Condensate Pan — Each cal is equipped with a
oorroaaion-resistant condensate dradlo m pan. The condensate drain
;40
pea is designed with a ope help ensureproper drainage,
improved moist re removal,and home comfort.
�,. Compact Design — The unique designis great for all those
\, 11. horizontal applications. They are designed for either
'0 horiaoatal-right or horizontal-left furnace fit up.The coil is ideally
` suited for either attic or crawl space installation
Bras Inserts—Every condensate pan features two 3/4-in.female
threaded readed bras s insert connections.The unique brainserts provide
CNPHP CNRHP for a leek-free condensate line connection to prevent water
damage.
Refrigerant Connections—The coils are provided with proven
sweat connections for leak-free operation maintaining system
reuabliey-
Burst Ptesaam—Ther coils meet or erred burst presnrs of
2100 psi which is at least three to five times the pressure they will
see in actual application_
Thermostatic Expansion Valves(T'XV►—All the Carrier coils
have refrigerant-specific fidary-installed TXVs.
Tenon Ring—The ring,installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
fixture service calls. Tifton works with both Peron and R-22
refrigerants.
Residential Carrier Products Bldr 1.19k Page 44 of 44