Report (2) ,4,2-oS= 0605-3 EJELr14795 S.W. 72nd Avenue v . PORTLAND, OR 97224 a v,1441 v. PHONE 503-620-4020 FIRE' INC FAX • CCB#64174 503-620-1058 SAY 2 7 01-, .1L:DIN1 F'I 'ISMO\ ISI QCD — Freezer Expansion Tigard, OR DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM X REVIEWED REVISE AND RESUBMIT REJECTED MAKE CORRECTIONS NOTED Vendor is entirely responsible for performance of his product(s) Corrections or comments made on the shop drawings dunng this review do not relieve contractor from compliance with requirements of the drawings and specifications. This check is orgy for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for: confirming and correlating all quantities and dimensions: selecting fabrication processes and techniques of construction: coordinating work with that of all other trades: and performing work in a safe and satisfactory manner. VLMK CONSULTING ENGINEERS (503)222-4453 Date: 5/22/15 By: Jason Sahlin April 30, 2015 DELTA FIRE, INC. PROJECT # 15-5400 FIRE PROTECTION CONTRACTORS 14795 S.W. 72"Avenue PORTLAND, OR 97224 PHONE 503-620-4020 FIRE, INC. CCB# 64 503-620-1058 { 74 Pipe • •& F 1 1 FIRE PROTECTION CONTRACTORS 16 I• NUCPL■1111•. MINI. NMINULOMNIN I s == Pipe and Supply Corp. Pipe Specification A135 Specification A135 NPS 1/4 --30", Schedules 10, 40 and XL THD, Lightwall Scope Covers two grades of electric resistance welded steel pipe. Grade A is adapted for flanging and bending and is suitable for welding. Purpose for which pipe is intended should be stated on order. Kinds of Steel Permitted Open-hearth Basic-oxygen For Pipe Material Electric-furnace Permissible Variations The minimum wall thickness at any point shall not be more than 12.5%under the nominal wall thickness specified. in Wall Thickness Threadable,lightwall(XL)must meet manufacturers minimums. Chemical C max% Mn max% P max% S max Requirements Seamless or ERW Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Tensile Grade A Grade B Requirements Tensile Strength,min.,psi 48,000 60,000 Yield Strength,min.,psi 30,000 35,000 NDE& Hydrostatic inspection test pressures for plain end and threaded are specified. Hydrostatic pressure shall be maintained Hydrostatic for not less than 5 seconds for all sizes of electric resistance weld pipe. Non-destructive electric test should be in accordance Testing with practices E213,method E227 or practice E213. Permissible Variations Plus or Minus 10%schedule 10 in Weights per Foot Plus 10%minus 3 1/2%schedule 40 Permissible Variations Plus or minus 1% in Outside Diameter Mechanical Tests Tensile Test--Transverse returned on pipe NPS 8 and larger. Specified Flattening test--Three steps required with weld located 0°or 90°from the line of direction of force required. Number of Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style. Tests Required Lengths Pipe shall be furnished in 38'with a minimum of 20 ft. Pipe furnished to schedule 10 shall be in a specified length between 16 and 22 ft. Required Markings Rolled,Stamped or Stenciled(Mfgrs.Option) on Each Length Name or brand of manufacturer. (On Tags attached to Kind of pipe,that is,electric-resistance welded A,electric welded B,same schedule wall thickness,schedule 10 or 40,NL each Bundle in case ASTM A135 of Bundled Pipe) Length of pipe. General End finish may be plain end beveled or plain end square cut. Information • . 900 ELBOW 4',TE -PF/FINVIL — >)s Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed & 1) FM Approved for 500 psi service. - . Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME 916.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cove damage to pipe threads winch may cause leakage.Ductile iron fittings should be tightened three turns beyond bond tight,but no more than lour turns. Cal 4Z/ APPROVED F Ustripa Aram,*Del**sod Lnateacrn 90' ELBO hata ansfrann at woman.**corn or canon an atnar Silas Riamadanann. Max.Working Dimensions Approx. Nominal Ste . rnessure. A 8 W1.Loth kt(awn) 19 Oft) In.Arne (met) lbs.ft.g) i••—, A 1 500 1.50 1.50 0.62 11/4 500 1.75 115 0.90t _ --r $ 4., 1.6 500 1.94 1.94 1.20 ocommeisms 1 500 2.25 2.25 1.65 •—Waiting Pressure Ratings are for reference only and based on 5th pips.For the latest Ul/Litk, and FM pressure ratings versus pipe schedule,please visit ansilintl.com or canted your local Anvil Representative. • 45° ELBOW Anivik.; FC-PF/FINVI )) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore Ul.& ULC Listed & FM Approved for 500 psi service. 00. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads ore NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over lightening con cause damage to pipe*woods which may couse leakage.Ductile iron firings should be tightened three turns beyond bond light,but no more than four turns. e® UMW APPROVED Fa anntraapproval O.iie,and ir.1840.13 45 ELBOW via car*attain ar anricarryard corn or OCOUCI an aranr Sala Riverawaaa.r. Mac Working Dimensions Approx, Nominal Size . immure& A 8 Wt.Erich (rm) PSI&PO k Ortne 116.(g) 1 500 1.12 1.12 0.46 500 1.29 129 0.73 A 500 143 1.43 0.92 2 500 1.68 145 1.50 A—Working Pressure goings are for reference on and based on W1 40 pipe.For the latest UL/ULC, and FM pressure ratings versus pipe schedule,please visit on...linter=or contact your local Anvil Representative. STRAIGHT TEE Z ....�.1►��wtl /RNA- Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65.45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con coax damage to pipe threads which may cane leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than lour Inns. c®us Q U111111 APPROVED toe UsfroaAPOwa tMa*and LmOa►vn. STRAIGHTTEE ora row*abate at arwrrtl coma ammo an Myr Sales Raooava anw. Nominal s Max.Working Dimensions Approx. Pressure& A g Wt.Each tn.muni tsf t41b1 h.(rend h.hemi lbs.Mg) etnalmamen 1 500 1.50 1.50 0.85 B r ` 500 1.15 1,75 1.22 — Y -- - 1'r, t t v, 500 1.94 1.94 1.55 A A 2 500 2.25 2.25 2.45 A-Working Pressure Ratings ore for reference onty and based on Schd0 pipe.For the latest UVUIC, and FM pressure ratings verses Five schedule,please visit orsvilintl.00m or contort your tocol Anvil Represenlative. . . BUSHINGS (11,4411-V-1-12; VCPF/RNVIL- Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UI& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over hghiening con cause damage to pipe*woods which may cause leakage.Ductile iron fittirgs should be tightened three turns beyond hand light but no more than lour turns, e@.* LIT APPROVED For tredn-9.APP^C.0(*Win est Lasketcro BUSHINGSMR ow webs&ar ononnarmisrt corn or =Hari n arve 51n Flect•saentain. Nominal size Max'Working Dimensions Style Approx. Pressure. A B C Wt.Each k(nue) PS1 AP& Is.(own) hi 67s0 kit en& lbs.(kg) re-C 1 x 500 0.75 0.25 1.42 Outside 0.22 1 x 4i 500 0.15 0.25 1.42 Outside 0.17 1-1- tsA 500 0.80 0.26 1.76 Outside 0.28 Inside Head 11/2x 1 500 0.83 0.31 2.00 Outside 0.45 1½ 1½ 500 0.83 0.31 2.00 Outside 0.30 I C L : B 2 x 1 500 0.88 0.41 1.95 Inside 0.67 : L A 7* 500 0.88 0.34 2.48 Outside 0.73 Outside Head 2 x 17, 500 0.88 0.34 2.48 Outside 0.61 •-Working Pressure Ratings ore for reference only and based on sch 40 pipe.For the low ULIULC, end FM pressure ratings versus pipe schedule.please visit oiwinif cant or contact your locol Anvil tate. . CAP ;�li/i1VIVlt s11 iF Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore LPL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads ore NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron Fittings hone higher tensile strength than that of steel pipe.Therefore,aver tightening ton cause damage to pipe threads which may cause leakage.Ductile iron Atlings should be tightened three turns beyond hand tight,but no more than kwr tuns. Pi d UTO APPROVED CAP ra Aprr c >add L+r,rasw odsd our at dr towel an s ,n. Nominal Size Max.Working Dimensions Approx. PressureA A WI,Each in (mat) PSI fk e) In.(mm) 16t 1 500 1,16 0.32 t �.. A tY, 500 1.28 0.43 1'. 500 1.33 0.60 2 500 1.45 0.91 A-Voorking Pressure Palings one for reference only and based on 5ch.40 pipe.For the latest UUULC, and FM pressure ratings versus pipe schedule,please visit onvAintawn or contod your bail Anil Representative. COUPLING (7),IANvic CC-PP/ANVIL -D> Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & ' FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65.45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME 81.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over lightening con cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than lour turns, C®M Q UM APPROVED COUPLING `a`n ar sA wry Orion"'e L a wr. rebs,.a,« ,n vton n a contact.nArm,Son raoro,.r ns Nominal Size Max.Working Dimensions Approx. PressureA, A Wt.Each At!mm) PSI ON As.Or 1k fkg) h---C 1 500 1.61 0.10 ' ., ., ) 500 1.93 0.57 . 1A _ 1'::, 500 2.15 0.15 2 500 2.53 1.15 A-Waricing Pressure Rai ngs ore for reference only and based on$ch.40 pipe.For CO bleat UVUIC, and FM pressure ratings versus Pose schedule,please visit omnlintl.core or contact your local Anvil Representative. . . . . CROSS 145EEE'F'"iiD Ductile Iron .......t ..:,,,,., MATERIAL SPECIFICATIONS , t _...— Ductile iron threaded finings are Ul.& ULC Listed & '1. ' • FM Approved for 500 psi service. :,,, Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 „,.„ , Threads are NPT per ANSI/ASME B1.20.1. i I NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cause darnoge to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond bond tight,but no mare than lour hens. e@es '43: line APPROVED Fa LYstrits-APPT,AW NU"and lmfato'n CROSS ~ow websolo st ow*Anvont corn cc =wet an Mod'5.11.Rop•sonabin. Nominal Size Max.Working Dimensions Approx. , rreSSW OA A 8 WI.Each h.(kkl PSI M) k(ait) k(mm) ih.(4) 1 500 1.50 1.50 0.98 SOO 1.75 1.75 1.50 B --,-,;•.—, B1 t —xamein 1t:5 500 1.94 1.94 1.90 2 500 7.25 2.25 2.95 ___ 1v,z 1 500 1.58 1.67 1.27 A ' ,i, ,t..,':',.-. 11/2 x 1 500 L65 1.80 1.48 2 x 1 500 1.73 2.02 2.10 , ..,. A-Waking Pressure Ratings ore for reference only and based an Sch.40 pipe.For the latest UIJUIC, and FM pressure wings versus pipe schedule,please visit orwilinticom or contact your local Anvil Representative. . . , -...., REDUCING 90° ELBOW t7r)..4W11.e.: qt:rE_____PF/FINVIL ) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed & / FM Approved for 500 psi service. f, Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than shot of steel pipe.Therefore,over tightening can cause damage to pipe ihreads which may cause leakage.Ductile iron fittings should be tightened three turns beyond bond tight,but no more than lour turns. eg* 12> MRS APPROVED Fa UstryliAppcnnii(Mans and Lrnsatans REDUCING90ELBOW *Ain ar**ago al wornAnvir-li corn cr onnian an.4,4'5alors flarmvuornuns Nominal Sin Mot Working Dimensions Approx. . rressureA A 8 Wt.Loch In.Onm.) psi ape hi.(mnr) M.OW lbs.0,0 1 x'4 500 1.26 1.36 0.44 ,..!. - . 1 3/, 500 1.37 1.45 0.52 i 114x11. 500 1.34 153 0.64 .0.lip.,,.....4....4...rli -r----,t, • ,, ., ,s,:., .r. A.T.:, ''',,,,ir.,,(--i,rt 11/4x V. 500 1.45 1.62 0.72 A ,___ ..,ft5 :. ,... ..:i•• '...... _t177.7,17, 1 ailf 1 SOO 1.58 1.67 0.75 1 A x 1 500 1.65 1.;l 0.92 11/2r1Vi 500 1.82 1,88 1.08 2x.f., 500 1.49 1.88 1.08 2 x Y4 500 1.60 1,97 1.24 2 x 1 500 1.73 2.02 1.40 2 x 1V, 500 1.90 2.10 1.52 2x11/2 500 2.02 ' 2.16 1.65 „. . A-Waking Pressure Ratings are 6 reference only ond hosed on Sch 40 pipe.For the latest UL/ULC, ond FM pressure rolings versus pipe schedule,please visit onvilintl corn or contact your local Anvil Representative. REDUCING COUPLING ': .�. iiL /anwI Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC listed & FM Approved for 500 psi service, Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron finings hove higher tensile strength than that of steel pipe.Therefore,over tightening con cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond bond tight,but no mare than lour turns, 4®ee p tlels APPROVED LtstrqVAppvval REDUCING COUPLING asr,ou WINNOW u*WA 1rr.vrM oom maw an Ieaf SAYS na.tri alle4.rt.. Nominal Size Max.Working Dimensions Approx. Pressure. A WI.Each `^ to.buns) PS9 a/o) In.(no) lbs 41 500 1,69 039 A 0,53. 500 169 . ^ 1 z 3/4 ♦-waking Pressure Ratings ore for reference only and based on Sch.40 pipe.For the latest UUUIC, - and FM pressure ratings versus pipe schedule,please visit onvilinti.com or concoct your locol Anvil Representative. . . „ REDUCING TEE (. 111,..41..IMIE; (CC-PF/FINVI ) Ductile Iron i----Igiumw DuctileMiroAn-rtheade MATERIAL Ld , - Ct.. , ,. - -,1 ,• „: ,,0‘,',:-,)'., FM Approved for 500 psi service -----1 . Ductile iron per ASTM A536 Class 65-45-12 Dimensions . conform to ASME 816.3 1.--A-..1:-.--B-.-I 1 SfittPinEgsCaIFreICUAL&TIt ULC CNSListed 8, Threads are NPT per ANSI/ASME 81.20.1. R DUCING TEE NOTICE:Ductile iron fittings have higher tensile strength than thoi of steel pipe.Therefore,over tightening con(cane damage to pipe threads which Hex. Dimensions may come leakage.Ductile iron fittings should be tightened three turns Nominal Size Working ler cad; beyond hand 600,but no more than(Our turns, Pressure. A B C e@ve .4> k kW PS!(VW h.Ow) it.OW k OW 1k 04.1 LOTS APPROVED 1)61.,X 1 500 I.sp 1.38 1.50 0.64 Fo'Int,"251Appwel Dettois aml lmtleacrn 1AM ow mobsto it.....46.441 corn o, camel.r.4.6'Sal..RA:fr4111441. 11X.1 500 1.50 1.45 130 0)3 1 x i x 1/2 500 176 1.26 ' 1.36 0.71 REDUCING TEE 1)(104 500 1.31 1.37 1.45 0./6 Max. Dimensions Nominal She Working 1rix11/4 500 117 1.67 , 1.58 0.98 PressureA A B C 1x1x1V. 500 1.80 1.80 1.65 1.16 h.(mm.I PSI fIcht.) h.Intm.) k(mm1 In.NW 1k ) 1%xix'll 500 134 1.24 133 012 1.';'"IA 1 l''' 5' 99.-. " 1.."..52, 152, 1,..15 1.14, Nx1x3/4 500 145 1.37 1.62 0 l'A x iAx 1 500 1.85 ' iis 110 1.30 ho Nxix 1 500 138 1.50 1.67 1.00 1:/2 x 1 v,x),,,, 500 1.82 ' 112 118 148 WA FAx 2 500 2.16 216 2.02 118 1'Ax1x1A - 500 1.75 1h7 1.15 1,08 . . -,-, ...,, ';:; i4't' ..2 46 .', :',- j'.',.!' 1,41• 2x1x2 500 2,25 202 2,/5 2.15 1'./..x 1 x 1.i 500 118 110 1.82 1.42 lAxlIfix,k 500 114 1.34 133 0116 • ?x,lii• x2' ???-- 2.25 2...,10 2,25 230 2x1.4x'4 500 1.49 1.41 1.88 1.50 1Axl'Ax3/4 500 1A5 1.45 1.6/ 0.92 2 x 1 V:x3/4 500 110 1.52 ' 1.97 1.6/ 11,x i1/4x 1 500 1.58 158 1.67 0.95 2x1'.4.x1 500 1./3 165 2.02 1.64 11/4x l'..ix li, ' 500 1.88 1.88 1.82 1.45 1x1Vix 2 500 2.10 2,10 1.96 05 2x 1'..:i fl'+ 500 1.90 1.82 2.10 110 2 x 11/204 500 /.02 194 2.16 2.60 14 x 1 x vi 500 1,41 114 116 0.95 2x114x 2 500 2.25 216 2,25 2.35 1';x 1 x-,., 500 61 1.37 1.15 1.14 . - 0'. 2X2X4 500 1,49 ' 1A9 1.8.8 1.60 1/;x1x1 ' 500 115 1.50 1.80 1.11 . •. 7 x2xli'i 500 1.60 110 137 1.68 11, x 1 x l'A 500 1.82 1.67 118 1.34 l'ix 1 x 11? 500 114 1.80 1.94 - . 145 2 x 1x 1 500 1.73 1.73 2.02 1.85 • 2 x 2;11/4 500 110 ' 190 210 2.04 1,/,xl A x V; 500 1.41 1.34 1.66 1.05 2x2x1r.6 500 2.02 ' i.6 216 218 1Y;xi Vi x 24 500 1.52 1.45 1.75 1.15 - 2x2 x2'...'2 500 2.6.0 7..60 2.39 3.61 1Y;xlvol 500 1.65 1,58 1.80 1,25 -- .- 2x/xY, sop 1,74 1.60 2.3.2 2.28 1 x'.6 UA x7 500 2.16 7.10 2.02 1,90 ., ,. . . ..., l'kxl!....x'A 500 1.41 1.41 1.16 1.15 It:es-i " c,ond F Rprealings urerottgs cdYschodvic pronaseSchvOliirtont' intlfpr thece contoci your local Awn!Represerviossi" tire. ffr p :�o .e„� �, n^ Y' 7�.t +�� ?u.0 "�f .-4^. V at.- w,4, SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1/2, 3/4,and 1"/15, 20 ' and 25mm outlets for directly connecting sprinklers,drop nipples, sprigs,gauges,drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPC,Vds/FM approved for branch connections on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up t 1 to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied with a clear, rust inhibitive coating.Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E” Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical require- ments of ASTM A-449 and physical requirements of ASTM A-183. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. �Cta'IU�IC� or�� n 1n c.. IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS I V.JL • Fp_ 4__. g [. g tF�v __ _ l • Fire k.�s� Olid --..4 UL FM ® (yds) [LK SEE VICTAULIC PUBLICATION 10.01 MR DETAILS STYLE 922 9 ' : t DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each Run X Branch +0.061+1.5 Y Z EPTt -0.001-0.0 - T* V W Y Z Ibstkg 1/42 X Y2 13/6 1.30 1.83 1.10 3.87 2.56 1.0 V � 111 32 15 30.2 33.0 46.5 27.9 98.3 65.0 045 41111-1111112117 \� '/ 1,A 1 28 831 103.8i2.56 l 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 #w• ( 1 , 11/,6 1.52 2.18 1.10 3.8/ 2.56 1.2 ,V� 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 /2 131;6 142 195 112 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/a 13/i6 1.40 1.95 1.22 4.08 2.56 1.1 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/is 1.64 2.30 1.22 408 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 1/2 • 13/,6 1.66 2.19 1.16 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/ 13/6 1.64 2.19 1.16 1.60 256 1.1 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/,6 188 2.51 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 • 2 1/2 Yz 13/,6 1.91 2.44 1 71 5.40 2.56 1 6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3A 13/6 1.89 2.44 1.71 5.40 2.56 16 . 20 30.2 48.0 62.0 ' 43.4 137.2 65.0 0.73 1 13/6 2.13 279 1.71 5.40 2.56 16 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 13/i6 1.91 2.44 1 71 5 50 2.56 1 6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 • 3/4 1 3/16 1.89 2.44 1.71 5 50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13/6 2.13 2 79 1 71 5 50 2 56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com • VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. Cta,-.- • 1n C:^ 0 0CV/ rl IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS j U. 0 <C> (vds) SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 t 1 PERFORMANCE Equivalent Length of Nominal Size 1"Pipe lm hes/mm Feet/meters 1Vax 1 8.5 32 25 2.6 1' X 1 8.5 40 25 2.6 2X 1 8.5 50 25 2.6 21X 1 8.5 65 25 2.6 76.1 mm X 8.5 25 2.6 www.victaulic.com ictaul.c° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED,PRINTED IN THE USA. ----� ucv ri in of o SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. US&WORLD HEADQUARTERS CANADA CENTRAL AND SOLI1H AMERICA P.O. Box 31 905-884-7444 1-610-559-3300 Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax) 4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38(fax) 86-21-54253671 (fax) 1-610-250-8817 (fax) viceuro@victaulic.be vicap@victaulic.com • pickvic©victaulic.com UNITED KINGDOM MIDDI r FAST www.victaulic.com 111 111 111111111111111�������11111��11111�� 44(0) 1438741100 971-4-883-88-70 44(0) 1438313883(fax) 971-4-883-88-60(fax) WCAS-6QKGYH viceuro@victaulic.be UPDATED 8/2006 10.52 3355 REV D 1ctaLJlic° VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. --- -•--------- ( K7 I:::: EI_._-1:�T'\,. 14795 S.W. 72nAvenue PORTLAND, OR 97224 �' �", INC. EF °2° Hangers • FIRE PROTECTION CONTRACTORS • - PIPE RINGS ()..4.N.v.,i,‘ - Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range:1/2"through 8" Material:Carbon steel - Finish:Cl Galvanized Service:Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature:650°F Approvals:Complies with Federal Specification A-A-1192A(Type 10) \., WW-H-171-E(Type 10),ANSI/MSS SP-69 and MSS SP-58(Type 10). UL Listed and FM Approved (Sizes 3/4"-8"). T,; , Features: �, • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2"through 6"sizes.The capture is permanent in the bottom portion of the band,allowing the hanger to be opened during installation if desired,but not allowing the nut to fall completely out. Ordering:Specify size,figure number and name. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. Metric nut available upon request.Non-captured nut also available upon request. ;,,; fA $ Ci iiiiiiiii C. 11/4"through 8"pipe 1/2"through 1"pipe FIG. 69: LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Size Max Load Weight Rod Size A B C F 1/2 0.10 2' 2 19/16 3/4 0.10 23/4 1% 15/16 1 0.10 29/16 111/16 1 11/4 300 0.10 2% 13/4 7 — 11/2 0.10 3/8 23/4 1% 2 0.11 31/4 2% 11/8 21/2 525 0.20 4 2% 15/6 3 0.20 313/6 215/76 13/16 4 650 0.30 411A6 313/16 5 0.54 55/16 4% 19/,6 6 1,000 0.65 1/2 611A6 59/6 21/4 8 1.00 8 7 211/6 Note:Reflects changes in rod diameter from previously published data per recent revisions in MSS-SP-58&69 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: 1:1Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog PH-2008 • HANGER RODS (*?NV Fig. 146 Continuous Threaded Rod Size Range:'/4 through 1'/2"Stocked in six,ten,and twelve foot lengths.Other even foot lengths can be furnished to order. Material:Carbon steel;rod threaded complete length. Finish:0 Plain or 0 galvanized. Maximum Temperature:650°F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. I-1 Length ►i A FIG. 146: LOADS(LBS)•WEIGHTS(LBS) DIMENSIONS(IN) Rod Size Threads Max Load Weight A per Inch650° F per Ft. 1/4 20 240 0.12 3/e 16 730 0.30 Y 13 1,350 0.53 5/e 11 2,160 0.84 3/a 10 3,230 1.20 '/e 9 4,480 1.70 1 8 5,900 2.30 11/4 7 9,500 3.60 11/2 6 13,800 5.10 Note:Other rod sizes available upon request.Class 2 fit is available upon request. PROJECT INFORMATION APPROVAL STAMP _Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog PH-2008 _ illi �_ C . woodIt SAMMYS AI' • WOOD ip`1>4"`J +l ! ;#lit li'mouht Bar quantity 100 except as noted with this marking i•} 141e014 N i fPfi ,X ,,, '':::_1;.4 • Box quantity 50 Item # Model Rod Size Shk Dia Shk Lgth 20 GST.750 1/4-20 1/4 3/4 114 lllem a 100 21 GST 100 1/4-20 1/4 1 22 GST 200 1/4-20 1/4 2 23 GST 300 1/4-20 1/4 3 24• GST 600 1/4-20 1/4 6 See page 13 for Stainless Steel SA?Trt i t v �x ;4. ,"� 1 1 Note:Screws less than 2"in iipi'-Y t� "` "'""Ft'S.,',441'"' *"* y o tr a `a' ,y� 1d `q r' i i fV li �,, 17 , ,,,. .,,,;y,._,,A 4, length will be plated yellow. x. ,e,.10.°0-: • , , .,.�, � �� � _�. ` ... ,. '� r�1t Greater than 2"are cleor FM Test IA.Test UUFM zinc per ASTMB633I11 Item # Model Rod Size Shk Dia Shk Lgth Load,lb. Load,lb. Pipe Size Actual Pullout 10 GST.75 3/8-16 1/4 3/4 564#-6 Ry 11 GST 10 3/8-16 1/4 1 210#-7/16068 670#-3/4'Pry (j > 12 GST 20 3/8-16 1/4 2 940# 850# 3/4-21/2 1760#-Rr *14 lkcm*too) 27 • GST 25-380 3/8-16 3/8 2 1/2 1500# 4 2113#-Rr 8 13 GST 30 3/8-16 1/4 3 1475# 1500# 3/4-4 2060#-Ar 403• GST 40 3/8-16 1/4 4 2180#-Ar 14 • GST 60 3/8-16 1/4 6 2230#-Fr �e t � �� �s c ,r 1s ; s ;11.;,,4",,,k4.-+ 3 Item # Model Rod Size Shk Dia Shk Lgth Actual Pullout • 8 • GST 2 1/2-13 1/4 2 1760#-Fv e14SW Slum e1011 06• GST 2.5-381 1/2-13 3/8 2 1/2 2113#-Fr Note:the 014Sw mast be surd for screws with 1/2"cop 15• GST 3 1/2-13 1/4 3 2275#-Fr • 16• GST 4 1/2-13 1/4 4 2180#-Fr 17• GST 6 1/2-13 1/4 6 2230#-Fr Installations tintIiii thin z nominal width 1/21 ee Page 5 for installation instructions. (1` i Installation ;' ti ^ N€ EMIper NFPA 13 r 4 a ... . «.Sammy '# 3 so 6 u m.y " i TGI Joist/Truss 114111101 Consult trues manufacturer for , recommended installation point. r wood flooring (See"Special on"papi tl 4µ' Iwoojotei Lower face off mm •+ Say bum or Joist '"" !sup Minimum 2'Imbedm.nt Into base • .m materiel for NEPA 19 compliance For vertical use. °IN' L. ___—_ uta Install in center r '-e Sammy of lower face. Double Sheetrock Ceiling I II you don't see If.call us at ILI ! 1.888.773.0001 Wood-Sammys II 5 Note:Must be installed with appropriate nut driver to comply with warranty. LTA • 14795 S.W. 72nd Avenue D� PORTLAND, OR 97224 PHONE 503-620-4020 FIRE, INC. CCB# 64 670-1058 S • renkle r e a s FIRE PROTECTION CONTRACTORS Bulletin 014 Rev. F • co Model F1 FR56 Series Reliable® Quick Response Standard Spray Model Fl FR56 Sprinkler Types Standard Upright f"t`- - Standard Pendent Conventional r Vertical Sidewall Horizontal Sidewall ' . Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types . Standard Pendent ':" Listing & Approvals P# 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category y—"� Sprinklers, Automatic&Open (VNIV) $ moi. __. „ Quick Response Sprinkler ,414 Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2 sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- e " �" klers have demonstrated response times in laboratory tests • ` t which are five to ten times faster than standard response ,-- t : , 11 - sprinklers. This quick response enables the Model F1FR56 rr `► Series sprinklers to apply water to a fire much faster than ' -' standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely mann Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid Application in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands,forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec uid pressure increases. Continued heating forces the liquid for style and sprinkler type are in accordance with the lat- to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- opening the waterway and allowing the deflector to distrib sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • • Model Fl FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number p pp (SIN) Orifice Size Height Organization - • US Metric Upright Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position 1/2"(15mm) 1/" NPT(R1 ) 5.6 80 2.25"(57mm) 1, 2,3,4 RA1425(1) RA1414(1)(2) Conventional-Install in Upright or Pendent Position 15mm(1) 1/2" NPT(R1 ) 5.6 80 57mm 3,4 RA1475 (1)cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. " • < y r ,,,..,. , 1 0irt...... Kra ! - ,. Upright Pendent Conventional • Model Fl FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread _ K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(RV2) 5.6 80 2.25"(57mm) RA1414 (1) Refer to escutcheon data table for approvals and dimensions. f 2 5/8•D14. [66.7mm] it 2 I/4"HOLE DIA. HOLE IN CEILING _ 157.2mm) 2 5/16"DLI. [58.7mm] 1 15/16"DIA r [492mm] CUP L=- --=A L---= --I �==i� rY I"X I/2"REDUCER I I I 1"X 1/2•REDUCER TURN COLLAR UNTIL TIGHT r AGAINST SPRINKLER WRENCH BOSS \II � -- �/ I 1 II N \� _i_ /Z6 1\ _I FACE OF FITTING TO(') CEILING L J ADJUSTMENT(1) CEILING DIMENSION lll�llllllll 'i � 1 II If �( FACE OF F777INC t ,, it l mr l CWill„ .III TO FACE OF CEILING ' kill el [52mm) („111111 1/8" I I I kii iii I ADJUSTMENT V�P A .. 2 27/32"DIA. 014E001 ••- -� '' [72.2mm] 014f7;02 (I)REFER TO F1 &F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (1)REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. • Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Nominal Thread Size Sprinkler Approval Identification Orifice US Metric Height Organizations Numbers(SIN) 1/2"(15mm) 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485 15mm I/2"NPT(R1/2) 5.6 8.0 2.25"(57mm) 4(1) (1)LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance =Y. • .,` (Min. - Max.) 0110 Upright 4" (102mm)- 12"(305mm) Pendent 4" (102mm)- 12" (305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW • Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations • Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard 1"(15mm) 1/2" NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435 O 1 4 FACE OF FITTING TO FACE OF CEILING DIMENSION 1 1/4"MIN. 2 1/4" HOLE DIA. [31.Bmm] 4 -12" [57.2mmJ yr [3'2mm] [101.6mm-304.8mm] CEILING TO x 1"X 1/2" REDUCER \ DEFLECTOR Mwq...+ - • /____-ril r � _ 1 `Mt% 1. 11:--1- 1M r I �_f, ' 1 15/16" DIA.i //11x1 i I III [49.2mm] ' xx — 1111�' 2 27/32" DLA. I`_ i i - ,I�d [72.2mm] I‘__: ��7 Horizontal Sidewall 7;1 l TURN COLLAR UNTIL . TIGHT AGAINST SPRINKLER `\, WRENCH BOSS. Li (1) ADJUSTMENT 013F003A (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (2) FM APPROVED FOR 4" - 6"[101.6MM - 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. • Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal "K"Factor Thread Temp. Rating Max. Bulb Sprinkler Orifice Size Model Ambient Color Approvals Identification US Metric Sprinkler Cover Temp Number(SIN) 1/2"(15mm) 5.6 80 1/2" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1, 2 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 2,4(1) RA1414 1/2"(15mm) 5.6 80 1" NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1, 2 RA1414 1"(15mm) 5.6 80 1/2" NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°C Green 1, 2 RA1414 11)For VdS only= 155°F/68°C Norbulb and 1/2"[12,7mm]adjustment. 7"x 1/2"REDUCING TEE OR ELBOW \�- -,- I"x 1/2"REDUCING TEE OR ELBOW ll i. �---i l_ r---- 2 5/8" DIA. ll -------- �-- 2 5/16" DIA - HOLE IN CEILING _' r 2 5/8"" DIA. CUP m.----------11 2 5/16""DIA - ` - HOLE IN CEILING nw IIc�t71 1/2"MAX. CUP �_ cV' 4 SII - FACE OF FITTING l[_ralliM 1 1/2" MAX. TO FACE OF CEILING -----"� FACE OF FITTING ,..,.,4:, 7//-,-��,7 DIMENSION ,�i I`� ��I TO FACE OF CEILING __ 111114 bp T/I DIMENSION CEILING ` + Mt, ..�I'M ;;j ,5555, __ `s' Ia�-�� CEILING7—,._ ..41110".. ."----''� ' 1/2"" MAX. 15/16" 5/16" MAX. -.. . iii3/4" COVER ADJUSTMENT COVER ADJUSTMENT COVER PLATE COVER PLATE— I } ASSEMBLY3 /ASSEMBLY 5 76"' DIA. 3 5/16" DIA. - / SPRINKLER / SPRINKLER 1/2" ADJUSTMENT anvcm 5/16" ADJUSTMENT oi, oe • Figure 1 Figure 2 Installation Aid • A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- Important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135°F Installation (57°C) or 165°F (74°C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as- as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover The Model F1FR56 Recessed Quick Response Sprin- plate assemblies provide either 1/2" (13mm)or 5/16" (8mm) klers are to be installed as shown.The Model Fl or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers. The use positive pressure in the space above. of any other recessed escutcheon will void all approvals After a 25/8" (67mm) diameter hole is cut in the ceil- and negate all warranties. ing, the sprinkler is easily installed with the Model RC1 When installing Model F1FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can inserting or removing the wrench from the sprinkler/cup be obtained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHER PART • torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed klers. onto the cup. Final adjustment is made by hand turning The Model Fl FR56/CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact 1/2" orifice, 1/2" NPT (R1/2), 135°F (57°C), 155°F (68°C), with the ceiling. Cover plate removal requires turning in 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent • impediment to the space above. Conventional Concealed cover plate/cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate/cup assembly with the Model F1FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes (1) THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes Sprinkler Escutcheon Cover plate time may leave the bulb vulnerable to damage. RASCO Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated(4)(5) White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass(3) Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin Max.Ambient • Black Paint Black Paint Off White Classification Temperature Temp. Bulb Color Off White(2) Off White Black Paint °C °F Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100°F(38°C) Orange (1) Other finishes and colors are available on special order. Ordinary 68 155 100°F(38°C) Red Consult the factory for details. Intermediate 79 175 150°F(66°C) Yellow (2) cULus Listed only. Intermediate 93 200 150°F(66°C) Green (3) 200°F(93°C)maximum. • High(1) 141 286 225°F(107°C) Blue (4) cULus listed"corrosion resistance"applies to SIN Numbers (1)Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white. (5) FM Approvals finish as"Polyester coated"applies to SIN Number • Escutcheon Data (1) RA1414(Pendent)in standard black or white. Face Escutcheon rovals , �,s,m "A" Ceiling of Fitting Ordering Information or Wa Model Dimension Dimension Specify: p fy: Fl 1,3,4 Max Recess 11/2"(38.1mm) 3/16"-15/16" 1. Sprinkler Model Min Recess 3/4"(19.1mm) (5mm-24mm) 2. Sprinkler Type F2 1,2,3,4 Max Recess 11/2"(38.1mm) 3/16"-11/16" 3. Orifice Size Min Recess 1"(25mm) (5mm-17mm) FPPushon/ Max Recessed 7/16"(11mm) 11/2° (38.1mm) 4. Deflector Type Thread-off 1'4 MinReccsscd 15/16(24mm) 1"(25.4mm) 5. Temperature Rating (1)SIN:RA1435-cULus and FM permits use with Fl or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9. Cover plate Model The Models F1FR56 and F1FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soapand water, ammonia or anyother 13. Cover plate Finish p cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note:When Model F1FR56 Recessed sprinklers are ordered,the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- ' tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be _ maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. 5. Reliable. . . For Complete ProtectiOn Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gaugesldentification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. • Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. - Manufactured by The Reliable Automatic Sprinkler Co., Inc. �� Recycled ® (800)431-1588 Sales Offices vaOr Paper Reliabl (800)848 6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 02/11 P/N 9999970300 Bulletin 153 Rev.L i o0 ® Model F3 (7, 1 Dry Sprinklers Co r Features 1. The Model F3 Sprinkler utilizes Belleville Spring Closure Technology il 2. Styles available for Model F3 Dry Sprinklers: • Pendent • Recessed Pendent • Concealed • Horizontal Sidewall • Recessed Horizontal Sidewall II 3. 11/2" (38mm) escutcheon adjustment on pendent 49.1 40110. sprinkler. 4. 1/2" (13mm)escutcheon adjustment on recessed sprin- Pendent Pendent/HB kler with push-on/thread-off FP Model escutcheon (See Fig. 1) (See Fig. 2) ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed • sprinkler with push-on/thread-off CCP cover. 6. Attractive appearance. Employs 5mm frangible glass bulb and galvanized nipple. 7. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in , 1/4" (6mm) increments. a h '" _:; 8. Available in a variety of plated and painted finishes. { 9. Polyester Coated Corrosion Resistant Sprinklers. ''.--Z "'"* Recessed FP Pendent Concealed U.S. Patent Numbers 5,775,431 and 5,967,240. (See Fig. 3) (See Fig. 4) Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus). *�. ,.. Style Response Sprinkler Hazard ;, �` i;j System Type Pendent t � _ • 10 Recessed Pendent �' CCP Concealed Wet Pipe Light (R5314) Standard Dry Pipe Ordinary Horizontal Sidewall All Preaction Recessed Horizontal Sidewall Horizontal Sidewall Horizontal FP Sidewall (R5334) 2. Certified by FM Approvals (See Fig. 5) (See Fig. 7) Sprinkler Style Response Hazard System Type Pendent Light Recessed Pendent Wet Pipe Ordinary, CCP Concealed Standard Dry Pipe GroupsliP (R5314) All Preaction 1&2 ce , Horizontal Sidewall Wet Pipe .. Recessed Horizontal Sidewall Standard Dry Pipe Light "`ti (R5334) All Preaction ' 3. NYC MEA 258-93-E 4. LPCB Approved, CE listed 0832-CPD-2006 Horizontal Sidewall/HB (See Fig. 6) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • Model F3 Dry Pendent Sprinkler "A"Dim. _ 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments Finishes`') Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. ' I Bronze Brass(5) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Rating Temp. . White Polyester(4) White Ordinary 135°F (57°C) 100°F (38°C) Orange . Lead Plated(2) Ordinary 155°F (68°C) 100°F (38°C) Red Wax Coated(2)(3) Intermediate") 175°F (79°C) 150°F (66°C) Yellow Wax Over Lead(2)(3) Intermediate 200°F (93°C) 150°F (66°C) Green (1)Other finishes and colors are available on special order.Consult factory High 286°F(141°C) 225°F(107°C) Blue for details. Sprinkler can and escutcheon fabricated of brass for better weather (2)155°F(68°C)to 200°F(93°C)rating only. resistance in exterior applications. (3) 212°F(100°C) brown wax may be used on 286°F(141°C)sprinklers when maximum ceiling temperatures do not exceed 150°F(66°C). "]Listed and Certified only by cULus. (4) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White, (5)Not available for HB escutcheons. Inlet Protrusion Elevated Above Inside Pipe Inlet Protrusion Elevatee F 1" t-�1 Above Inside Pipe i -4I 1 --i- N li ' Q___ --,,.El rt-_,:-1Lcc_, - - system Tee System Tee �� "A"Dimension 2 '/2 [63.5mm] ME 1 NPT Adjustment Range Dia.Hole.n Ceiling IEEE 2 1/e"Dm. NPT -1/2"[-12.7mm] c coth<orB2amm] meat Ran ] [50.98,,,] In +1/z'[+1 z.7mm] Adjustment Range Mole in Ceiling -1/4"[-6.35mm] )Celunq 1/2"[12.7mm] ♦1 1/4"[+T 75mm 1 43/64"Dia. 1 1/2'[38.10mm] -- Escutheon Adj. [42.amm] IIIIl Total.Vjustment + [25.4 1" ] sp.inxle.can ces„y({ t 1/4'[n.75mm] EscutcheontMIMI Total Adj. '17E Esculheon Adj. ["'''""' '--C;,-, scutcM1eonr_ I/O"[6.35mm] 1 "411='Ceiling i ( Escutcheon Nominal Position 1 ' C,i"'� Adjustment Sprinkler Can � E of Escutcheon Nominal Positior\ 1,� 1-1/4"[31.75mm] IY�Y� t 5/e" of Escutcheon 1���1 t 5/8" Nominal P.ot.usion ( I [41.3mm] I1„/I [41.28mm] 10� 1/4'[6.35mm] — Protrveion 3"[76.20mm] 2 13/64"[55.88mm] ,.s2Fc,.e Dla. 153Fo61-0 Dia. • Fig. 1 Fig. 2 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/4"(-6mm)to+11/4" position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2" . (+32mm)"A"dimension adjustment range. (+12.7mm)"A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 Model F3 Dry Pendent FP Recessed Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Inlet Protrusion Elevated 46 -I T rf--if F_--„1 Above Inside Pipe 't IIII- I'I1 Finishes') Sprinkler Escutcheon 7==- r' `- -- Bronze Brass == system Tee Chrome Plated Chrome Plated 1W----...1 White Polyester(2) White 1” NPT (1)Other finishes and colors are available on special order. Consult factoryfor details. remainds unfinished. 2 t/r Dia. III Cup "A"Dimension [63.SOmm] Only the escutcheon will contain desired finish. Adjustment Range Hole in Ceiling t1/4" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or [±6.35,—] 2 19/64" Dia. White. [58.34mm] Standard Temperature Ratings —Nominal Position Sprinkler of Escutcheon Cup Assembly Sprinkler Max. Classification Temperature Ambient Bulb Color + + ng =� Escutcheon Rating Temp. mow!I1, �e;li 9 Ordinary135°F (57°C) 100°F (38°C) Orange 1/4"[6.35mm] I g Escutcheon Adjustment Ordinary 155°F (68°C) 150°F (66°C) Red 0 0 0 1/4" [6.35mm] (2) 3 7/32" Dia. • Intermediate 175 F (79 C 150°F 66 C Yellow Escutcheon Adjustment / ` ) (66°C) 1 f87.76mm [ ] —.- Intermediate Intermediate 200°F (93°C) 150°F (66°C) Green 1/2" [12.70mm]- 1 High(1) 286°F(141°C) 225°F(107°C) Blue Total Adjustment 15"°02 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig. 3 ' for interior applications. Note: Do not install the Model F3 Dry Pendent Recessed Sprinkler in (1]Listed and Certified Only by LPCB and cULus. ceilings which have positive pressure in space above. (2)Listed and Certified Only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 2. . Model F3 Dry Pendent Concealed Sprinkler _ • "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Inlet Protrusion Elevatedr- -- # r-1i1FF---k,, (1) ) (2) Above Inside Pipe IM 1 CCP Cover Plate Finishes I Standard Finishes •Special Application Finishes si�;t • Chrome Plated Bright Brass Plated _=5 System Tee White Black Plated iays Black Paint 1-NPT Off White • 2 1/2•eAn III Chrome "A"Dimension 163.50mm] Atljustmenl Range Hole in Ceiling (1)Utilizes the 1/2"cover plate with 3/8"total adjustment. t 3/16" (2)Other finishes and colors are available on special order. [±4-76^,^3 2 19/64"C . p [56.34mm1 Consult factory for details. Standard Temperature RatingselrpPa=e"°° Sprinkler Cup Assembly Sprinkler Max. —i c°•¢,,late Classification Temperature Cover Plate Ambient Dei;in9 Assembly Rating Temp.Rating Temp. '�I`t,I,'- ce;li^g Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) 3/16"[4.76mt 1 caverplate Adjustment Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) 3/16"[4.76mm] Intermediate(1) 175°F (79°C) 165°F (74°C) 150°F (66°C) Coverplate Adjustment 3 5/16" Dia. y Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) 3/5"[9.53mm] 84,3mm] -C High111 286°F(141°C) 165°F (74°C) 150°F (66°C) oral Adjustment 5=r�° Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Fig. 4 brass and recommended for interior applications. Note:Do not install the Model F3 CCP Pendent Concealed Sprinkler in ceilings which have positive pressure in the space above. (1)Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5314 Model F3 Dry Horizontal Sidewall Sprinkler "A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4"(6mm)increments Finishes(1) Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. I Bronze Brass(5) Classification Temperature Ambient Bulb Color Chrome Plated Chrome PlatedRating Temp. White Polyester(4) White Ordinary 135°F (57°C) 100°F (38°C) Orange . Lead Plated(2) Ordinary 155°F (68°C) 100°F (38°C) Red Wax Coated(21131 Intermediate(1) 175°F (79°C) 150°F (66°C) ' Yellow Wax Over Lead(2)(3) Intermediate 200°F (93°C) 150°F (66°C) Green • (11 Other finishes and colors are available on special order. High - 286°F(141°C) 225°F(107°C) Blue Consult factory for details. Sprinkler can and escutcheon fabricated of brass for better weather (�) 155°F(68°C)to 200°F(93°C)rating only. resistance in exterior applications. (3)212°F(100°C)brown wax may be used on 286°F(141°C)sprinklers when maximum ceiling temperatures do not exceed 150°F(66°C). ")Listed and Certified only by cULus. (4) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (5)Not available for HB escutcheons. 1" [25.4mm] —.a—a- 1 1/2" [38.10mm] Total Adjustment ____---------__-----------� Total Adjustment _- _-_----__-___— Ceilin 9 7, i ceirm i — — — — — — — J F I- -------9--------'r 1/2" [12.7mm] f = T Escutcheon Adjustment 4"[101.60mm] Min. 4" [101.60mm] Min. 1/2G. 12" [304.80mm] Max. 1 1/4" [31.75mm] 12" [304.80mm] Max. Escutcheon Adjustment~r 2 3/32" Escutcheon Adjustment 1 1/4" [6.35mm] Vstern Tee 3° -� [53.18 .F System Tee I J �� -j-s, Escutcheon Adjustment 1 NPT 1" NPT [ t 2 3/32" ii: 11 C\ II �_I L✓_ =`I 3" Dia `4 111 1I------- -' - ----- ' [76.20mm] \ ,-� ��; %--tom aP I 2 1/2" Dia. - [63.Smm] II2 1/8" Dia. Hole in Wall 1-1/4"[31.75mm] Nominal [53.98mm] '3 Protrusion Hole in Wall 1.---] F_1/4" [6.35m m] Sprinkler Co" Protrusion "A"Dimension Escutcneon Sprinkler Can Adjustment Nominal Position Range + 1/2"[4-12.7mm] of Escutcheon "A" Dimension rserooxr - 1/2" [-12.7mm] Adjustment Nominal Position • 1500004-0 Range - 1/4" [-6.35mm] of Escutcheon re,P004-o + 1 1/4 [+31.75mm] Fig. 5 Fig. 6 • Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides-1/4" (-6mm)to +11/4" position. Escutcheon adjustment provides-1/2"(-12.7mm)to+1/2" (+32mm)"A"dimension adjustment range. (+12.7mm) "A"dimension adjustment range. Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5334 3. • Model F3 Horizontal FP Recessed Sidewall Sprinkler "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments Ceiling Finishes(1) i_F ' Sprinkler Escutcheon 1 13/32" 35.7mm] Bronze Brass f=' 4" [101.6mm]Min. Chrome Plated Chrome Plated system Tea Cup 13 I* 6" [152 4mm]Max. • White Polyester(2) White 1" NPT (1)Other finishes and colors are available on special order. ,-�-_,__s- �il�_ Consult factory for details. ' }` IIIIIII I (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or { I II���� -' 3[81 8lm]° �IIII�II � White. � %---+ 2 1/2" Dia. ' Sprinkler's can and FP Escutcheon are fabricated of steel and recom- H[o6e.5min W]o 13 Nominal Position of Escutcheon mended for interior applications. 2 19/64" Dia [-.a [58.3mm] 1/4" [6.35] I Escutcheon Adjustment Standard Temperature Ratings "A" Dimension 1/2" [12.7mm] Adjustment Range Escutcheon Adjustment 1531-G05-0 ±1/4" 1/4" [6.35] Sprinkler Max. [±635] Escutcheon Adjustment Classification Temperature Ambient Bulb Color ,, For Factory Mutual (FM) Rating Temp. 4" - 6" for Underwriters Laboratories (UL) Fig. 7 Ordinary 135°F (57°C) 100°F (38°C) Orange Note: Do not install the Model F3 Dry Horizontal Recessed Sidewall Ordinary 155°F (68°C) 100°F (38°C) Red Sprinkler in walls which have positive pressure in their side Intermediate"I 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green space. High t1j 286°F(141°C) 225°F(107°C) Blue • Recessed Horizontal Sidewall sprinklers are listed by cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) ("Listed and Certified Only by LPCB or cULus. below ceiling, and FM approved for installation of min. 4" (100mm)-to-max. 12"(306mm). Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5334 r Technical Data Ordering Information Orifice Size: '/2" (15mm) Specify: Thread size: 1" NPT per ANSI B2.1 1. Sprinkler Type (select one): Working Pressure: 175 psi (12 bar) (a) Model F3 Dry Pendent Nominal K Factor-US/(Metric): 5.6/(80) (b) Model F3 Dry Pendent/HB Product Description (c) Model F3 Dry Recessed Pendent Reliable Model F3 Dry Sprinklers are standard response (d) Model F3 Dry Concealed Pendent sprinklers utilizing a durable 5mm frangible glass bulb. (e) Model F3 Dry Horizontal sidewall Model F3 Dry Sprinklers are intended for use in dry and pre- (f) Model F3 Dry Horizontal sidewall/HB action systems and in areas subjected to freezing tempera- (g) Model F3 Dry Recessed Horizontal Sidewall tures, such as freezers and unheated portions inside and 2. Sprinkler Temperature Rating. outside buildings. 3. Sprinkler Finish. P 4. Cover Plate FP Escutcheon Finish. Environments wherein dry sprinklers are employed can / p be corrosive. For this reason, Model F3 Sprinklers have a 5. Length: "A" Dimension(face of tee to face of ceiling or special wax fillet placed in the gap between the cup that wall) in 1/4" (6.4mm) increments. supports the bulb and the wrenching boss.This wax will not 6. Model F3 Dry Pendent (a) is available without sprin- interfere with the operation of the sprinkler, and it prevents kler can and escutcheon. contaminents from entering the internal portion of the drop Note: nipple.The wax must not be removed. 1. The "A" dimension is based on a nominally gauged Operation pipe thread "make-up" of .600" (15mm) per ANSI The glass bulb consists of an accurately controlled amount B2.1 [7 1/2 threads approximately]. of special fluid hermetically sealed inside a precisely manu 2. All platings and paintings are decorative and intend factured glass capsule. When the temperature increases ed for interior use. r sufficiently due to a fire, the bulb shatters allowing operat 3. Acceptable appearance in conditions such as park ing parts to clear the waterway. This enables the inlet seal ing garages is generally provided with bronze sprin to release air or water and subsequently, cause water flow kler, brass cup and escutcheon for the Model F3 Pen • over the deflector in a uniform spray pattern, controlling or dent only. extinguishing the fire. 4. General Installation Instructions Maintenance Model F3 dry sprinklers must be installed only in stan- The Model F3 Dry Sprinklers should be inspected quar- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) terly and the sprinkler system maintained in accordance • pipe tees in the horizontal position,even at branch line ends. with NFPA 25. Do not remove the factory applied thermally They should not be installed into elbows or pipe couplings sensitive wax fillet between the bulb supporting cup and the located on drop nipples to the sprinklers.For these and other wrenching boss. Do not replace this wax with a substitute • fittings including CPVC,the dry sprinkler should be installed substance.An Alternate substance may interfere with proper into a fitting to allow protrusion into the fitting in accordance operation of the sprinkler. Do not clean sprinklers with soap with the diagrams. The "A" dimension of the dry sprinkler, and water, ammonia or any other cleaning fluids. Remove which extends into the freezers or a freezing zone from wet dust by using a soft brush or gently vacuuming. Remove pipe systems, should be selected to provide,as a minimum, any sprinkler which has been painted(other than factory ap- the specified lengths in inches shown in Fig. 8. plied) or damaged in any way. A stock of spare sprinklers Caution: should be maintained to allow quick replacement of dam- Do not install Model F3 Dry sprinklers into CPVC adapter aged or operated sprinklers. Prior to installation, sprinklers fittings or tees that have an internal obstruction. This will should be maintained in the original cartons and packaging damage the sprinkler and /or the fitting. Refer to Fig. 9 until used to minimize the potential for damage to sprinklers During installation, the following steps must be followed: that would cause improper operation or non-operation. 1. Cut the specified size hole (see illustrations) for the sprinkler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on /thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3 Sprinklers is not recom- mended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3 Concealed and Recessed Installation Instructions • The Model G3 R/C Wrench (Fig. 10) is designed to locate on the wrenching pads of the Recessed sprin- kler while centering in the cup. A standard 1/2" drive ratchet may be used to drive this wrench. Figures 11 and 12 show sequentially the insertion of the wrench. First, the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 12). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector with the wrench. • Model G3 Wrench (Fig. 13) is used for installation of Pendent and Horizontal sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 5. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT PER ANSI B 16.3 (CLASS 150 AMBIENT TEMPERATURE Fti 150) TEMPERATURE -�- ,---m--_-_-,,-, OR CAST IRON THREADED TEE FITTING OF PROTECTED 40'F/4'C 150'F/10'C 60'F/16'C �' ' , 111 PER ANSI 16.4 (CLASS 125) ONLY. fi AREA AT THE 4- IIiII--- - 1i-IIII I -'4 DISCHARGE END EXPOSED MINIMUM BARREL LENGTH"" �II OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) ___==�o----( L---v�t_=-_; IN. (MM) IN. (MM) IN. (MM) LJ 1.��. I 1J r L, IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40'F (4'C) 0 0 0 0� CAUSES CONDENSATION ON THE EXPOSED DRY MINN SPRINKLER, CONSIDER WRAPPING THE EXPOSED 30'F (-1'C) 0 0 0 BARREL WITH INSULATION, FOAM INSULATING 20'F (-TC) 4 (101) 0 0 TAPE OR EQUIVALENT. 10'F (-12'C) 8 (203) 1 (25.1) 0 , 0'F (-18'0) 12 (305) 3 (75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -10'F (-23'0) 14 (356) 4 (101) 1 (25.1) EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED -20'F (-29'C) 14 (356) 6 (152) 3 (75) LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH -30'F (-34'C) 16 (406) 8 (203) 4 (101) COULD INHIBIT OPERATION OR CAUSE -40'F (-40'0) 18 (457) 8 (203) 4 (101) PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. �A� CLEARANCE -50'F (-46T) 20 (508) 10 (254) 6 (152) DIMENSION HOLE -60T (-51'C) 20 (508) 10 (254) 6 (152) ll " THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. 1 THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE SPRINKLER.END OF THE FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES , A 1 . LISTED, USE THE NEXT COOLER TEMPERATURE. __ MIIMMOMIII "'THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. CEILING �� ii ESCUTCHEON I NOTE EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH llirl� WIND VELOCITIES IN THE PROTECTED AREA. 1„/ (PROTECTED AREA) -= - 3" DIA. • *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE sT =_= ti # s i r 11-11--f9I y liji I lih _ lilih - 1111 L i,,, l II 1 I J = a---I,p t -a =r '1 r = 5 1 (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL LENGTH DECKTITE FLASHING BARREL INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO M (SEE ABOVE) 1 (RECOMMENDED) i \ 1 %MAMA. //. I/////// "HAIIIIIIIIIIIM 1111 Ila CLEARANCE HOLE II INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING //////. 1 /N////A. V//////. I/ //� 1 --_ -- • (PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) V1 DRY SPRINKLER . �I`U,I� IN COLD AREA 1I���I� IN COLD AREA Fig. 8 6. , *CAUTOON* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO - CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. • CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION , FEMALE O` /r FEMALE Al PIPE %� 1S PIPE %t 1l THREAD �� t� THREAD ��� t� INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL-LINE OF MODEL F3-PL, MODEL F3QR-PL, AND • MODEL DH56 HSW-PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. SHORTER Ilia LONGER INLET INLET MALE MALE PIPEPP PIPE THREAD THREAD jii MODEL F3-PL, STANDARD MODEL F3QR-PL OR MODEL F3, MODEL DH56 HSW-PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR • APPLICATION 016f908 Fig. 9 7. • i A y, r *s..,', t04 -a , , „„ ,— ,,,,,.. toor M A .:. ry ,fib. 4 9 Fig. 10-G3 R/C Wrench Fig. 11 -G3 R/C Wrench Fig. 12-G3 R/C Wrench If 1 I yeti i 1 t Fig. 13-G3 Wrench The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. • Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. • Manufactured b The Reliable Automatic Sprinkler Co.,Inc. �� Recycled ® (800)431 1588 Sales Offices va Paper (914) Reliabit (800)848 2051 Sales Fax www.829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 02/11 P/N 9999970146