Loading...
Specifications (12) )64,024)5-- Pp/ Z � 7 ,3i 5, � / t RECEIVED APR 3 0 2015 CITY BUILD/NG' DIVISION QUALITY CUSTOM DISTRIBUTION FREEZER ADDITION 7319 SW Kable Lane, Suite 500 Tigard, OR 97224 STRUCTURAL CALCULATIONS VLMK Project Number: 20150024 Sierra Construction Company • 1700 SE 11''' St, Suite 120 Portland, OR 97214 s,NRUCTURq< 4\cy"-p PROFESS Co ;6 At E /17/15 OREGON �, 9 • /5, s- ON C. S P`r EXPIRES: 6/30/20 16 „Iv VLMK Prepared By: Amy Kordosky, EIT 4/17/2015 _ ENGINEERING + DESIGN r Structurtil Quality Custom Distributions—Freezer Addition BC i Quality Custom Distribution Freezer Addition 7319 SW Kable Lane, Suite 500 Tigard, OR VLMK_JOB NO. 20150024 STRUCTURAL CALCULATIONS FOR BUILDING PERMIT TABLE OF CONTENTS Design Outline and Criteria DC-1 thru DC-2 Structural Calculations C-1 thru C-17 Reference Documents R-1 thru R-8 DESCRIPTION OF STRUCTURAL SYSTEM The 'Quality Custom Distribution — Freezer Addition' project consists of the addition of a freezer and two rooftop units at the above noted address. One unit is a condenser and the other a package unit. These units have been designed to resist wind and seismic loads. 3933 SW Kelly Avenue Portland,OR 97239 te!.503,222.4453 b1LrrtK.i.OM G:\kitd2015\201500240140150024 DC, orix Structured[u,alratio is:nudity Custom Distributions—Freezer Addition DC-'i CODES 2014 Oregon Structural Specialty Code (Based on the 2012 International Building Code) DESIGN LOADS Live Loads Roof Snow Load Flat Roof Snow Load, Pf 25 psf Dead Loads Roof(Panelized) Roofing (new and future) 4.0 psf Insulation 1 .5 psf Sheathing (5/8" plywood) 1 .8 psf Sub-purlins (2x4 at 24") 0.7 psf Joists 3.0 psf Girders 1 .0 psf Mechanical and Electrical 1 .0 psf Miscellaneous 0.9 psf Total Roof Load 14.0 psf HVAC Unit Weights Condenser Unit 3,770 lb Package Unit 176 lb Wind Ultimate Design Wind Speed, V,i' 120 mph Risk Category II Wind Exposure B Internal Pressure Coefficient GC1. = +/- 0. 18 Seismic Seismic Importance Factor, I, 1 .0 Risk Category II Mapped Spectral Response Accelerations S.. = 0.968 S 0.420 Site Class D Spectral Response Coefficients S_ = 0.718 = 0.442 Seismic Design Category D Analysis Procedure Used Nonstructural Component Component Anchorage Factors ar Rr HVAC Equip 2.5 6.0 1 .0 2.5 3933 ,WKelly Avenue Portland,OR97t3> ie:50 .111.;15i iA ?t ; jcurf21 S\wf150O24: lcq.(1 5002.4 DC.docx Ei).4L:. eci