Loading...
Report (25) 4ufc)ocs'--ocoi • 1 t Cr2 1 Sw / e°/D�'z �• I COOK SUBMITTAL JAN 15 2015 CITY OF TIGARD BUILDING DIVISION PROJECT: TIGARD POPCORN HOOD FAN SUBMITTED BY: Bob M E-MAIL: bobm©acimechsales.com DATE: 12/30/2014 �, LORE C..O COMPANY 'tel i Corporate Offices:2015 E.Dale Street,Springfield,MO 65803 • P.O.Box 4047,Springfield,MO 65808 1.0t/t! 417.4696474 • fax 417.8925�f1 --"-+-- lorencook.cort 0.1.\i MARK: EF-1 COOI(' ,, PROJECT:TIGARD POPCORN HOOD FAN l` c �L o1 DATE: 12/30/2014 VCR-HP Upblast Centrifugal B Exhaust Ventilator _ Roof Mounted/Belt Drive STANDARD CONSTRUCTION FEATURES: _ All aluminum housing - Backward inclined all aluminum wheel-Two � s11§!!!, ' piece top cap with stainless steel quick release latches-One pieceIJA! bottom spinning -Welded curb cap corners-LiftingLugs- C 9i Permanently lubricated ball bearing motors-Oil and heat resistant, �>_�p ��� Astatic conducting belts-Adjustable pitch drives through 5 hp motor- �i='- -=� Corrosion resistant fasteners-Regreasable bearings in cast iron pillow =IiU�iii ' block housing, rated at 200,000 hours average life-All fans factory II�:IiI d adjusted to specified fan RPM-Transit tested packaging. 4 �T Sq. ` G Performance -Bhp includes 14%drive loss) Dimensions (inches) Catalog Flow SP Fan Power* A 20-15/16 Qty Number (CFM) (Inwc) RPM (HP) FEG B 34-11/16 1 150VH5B 900 1.00 1459 .363 n/a(<1HP) C 27-1/2 Altitude(ft): 400 Temperature(F): 70 G 2 Motor Information HP RPM Volts/Ph/Hz Enclosure Mounted T Sq. 24 Roof Open. Sq.* 19-1/2 1/2 1725 115/1/60 ODP -SE Yes NOTE:Accessories may affect dimensions shown. Sound Data Inlet Sound Power by Octave Band (Shipping Weight(lbs)*** 144 I 1 2 3 4 5 8 7 8 LwA dBA Sones •Roof opening size for aures supplied by Cook only. • •••Indudes fan,motor 8 accessories. 82 73 70 65 63 66 61 55 71 60 10.7 Accessories: DRIVES(1.5 SF)@ 1459 RPM ROOF CURB RCG 22-13.5H-LESS NLR UL762(327Y-300DEG) KEYWAY GREASE TROUGH Fan Curve 1.50 .500 1.20 • / • .400 7 1 0.90 / c ' , 300 0 ^ i a i in 0.60 - ,/ .200 0.30. .100 Fan Curve Legend - CFM vs SP 0.00 0.00 CFM vs HP 0 300 600 900 1200 1500 Point of Operation 0 Flow(CFM) System Curve v6.4.128.12745 M:\CookwareUobs8BobM Page 2 of 4 PROJECT:TIGARD POPCORN HOOD FAN -- COoK 44f DATE: 12/30/2014 RCG Galvanized Steel Roof Curb STANDARD CONSTRUCTION FEATURES: 18 gauge galvanized steel-1-1/2", C Wood Nailer 3 lbs. density thermal and acoustical V Sq. insulation -Continuously welded corners- I F Sq. -1 + Wood nailer. \ . A } Options:(As noted below") For otv$ 1) No wood nailer(deduct 1-1/2" Ht. for actual height). i 2) Damper tray. 0 I , 1—R(7of W 1 j\ Sq. Optional Damper Tray Insulation Opening Dimensions (inches) Mark Qty Description Ht Options* A F Sq. V Sq. .W Sq. Roof Opening EF-1 1 RCG 22 13.5 1; 1-1/2 22-1/2 26-1/2 15-3/4 19-1/2 v6.4.128.12745 M:\Cookware\Jobs\BobM Page 3 of 4 } PROJECT: TIGARD POPCORN HOOD FAN -- COOK DATE: 12/30/2014 Grease Trough Keyway Mount INLET STANDARD CONSTRUCTION FEATURES: All aluminum .063 construction-Continuously welded trough housing corners-Removable lid MOUNTING HOLES for servicing -Slotted mounting holes for easy SEE DETAIL removal -Baffled design for extended capacity. E libt, A WATER GSI Imo- OVERFLOW 6B >j F H Dia. MOUNTING HOLE DETAIL Dimensions (inches) Mark Qty Description A B C DE F G H Dia. EF-1 1 KEYWAY GREASE TROUGH 5 12 6-1/16 6-1/2 4-1/2 1/2 3/8 11/16 v6.4.128.12745 M:\CookwareUobs\BobM Page 4 of 4