Loading...
Report (24) WS ;ols--- uici 61 . . R _ f 2,1/ t-/2_ ,5--GI Sc4 /1 -.-i- Ci•S1mleX LifeAlarm® Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 lab - 7m NAC Extender for Control from 4010 or MEA (NYC)Acceptance* 4100U IDIS l0 .r e i ns; or from Conventional NACs h Features SEP 1 0 2015 Provides additional notification appliance circuit M.(NAC)capacity with flexible operation modes and CITY OF'TIGAkt power-limited design BUILDING DIVISIOh Up to 8 NACs Four, Class B(Style Y) NACs are standard: .� • Rated 2 A each for conventional reverse polarity 7 4009 IDNet 24 VDC notification appliances and providing NAC Extender rim — multiple operation modes IM Pi. • Can be selected to provide synchronization for ■! Simplex®visible notification strobe flashes Optional IDNet • Capable of controlling TrueAlert®non-addressable Channel Repeater notification appliances operating with SmartSyncTM two-wire control mode** , •% '� `� -y- =•—•Input control options: ! `% `% �N, "� • IDNet addressable communications from a Simplex 2-wire IDNet •�` �` .` model 4010 or 4100U Fire Alarm Control Panel** CommunicationsQC • �` r Fiber Optic IDNet • • Or from one or two conventional 24 VDC NACs with I Communications Qt `, multiple output control options —__ •• NAC Control IDNet communications control benefits: - -r,' / > • Provides status monitoring and individual NAC control M _ IDNet Fiber using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet"Device Level"earth fault location - 4010(shown)or WALKTESTTM operation is available with either 4100U Fire Alarm wiseess input choicer Control Panel Internal 8 A power supply/battery charger: Fire Alarm Control Panel with Conventional NACs • Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet • Provides status monitoring of battery,input power,and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for"Special Application"appliances; including Simplex 4901,4903,4904,and 4906 Series ADA Compliance.Complying with the notification horns,strobes,horn/strobes,and speaker/strobes requirements of ADA(Americans with Disabilities Act) • Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is available within the fire alarm control panel.When Optional 4009 IDNet NAC Extender modules: additional power is required,a Simplex 4009 IDNet NAC • IDNet Communications Repeater provides Class B Extender can provide up to 8 A of NAC power with up to (Style 4)or Class A(Style 6)output eight,supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility.The 4009 IDNet NAC Extender available as Class B or Class A can be mounted close to a compatible dedicated host • Four additional Class B NACs,rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution.Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A(Style Z),Two Circuit Adapter Module Additional Information.For additional operation detail UL Listed to Standard 864 and application information,refer to Installation Instructions 574-181 and field wiring diagram 842-068. External Accessories • ULC listed model is 4009-9202CA.This product has been approved by the California State IDNet communication fiber optic transmitters: Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM listing 7300-0026214 for allowable values and/or conditions concerning • For applications requiring the data integrity available material presented in this document It is subject to re-examination,revision,and possible with fiber optic communications cancellation.Acceptedncellation.Acceptedfor use—City of New York Department of Buildings—MEA35-93E. Additional listings may be applicable;contact your local Simplex product supplier for the • Available as Class B(Style 4)or Class A(Style 7) latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. • Mounts in standard six-gang electrical box - SmartSync horn/strobe operation is protected under U.S.Patent No.6,281,789.IDNet External battery cabinet for 18 Ah batteries addressable communications are protected under U.S.Patent Nos.4,796,025; 5,966,002;and 6,034,601.4100U requires revision 11 software or higher for t Simplex WALKTEST service testing is protected under U.S.Patent No.4,725,818. compatibility.4010 requires revision 2 software or higher for compatibility. S4009-0002-4 2/2006 • Application and Operation Information Hardwire Control Applications.For applications where an existingconventional NAC needs IDNet Addressable Communications Compatible. (or new) additional power,the 4009 IDNet NAC Extender can be Up to five,4009 IDNet NAC Extenders can be controlled controlled directly from the NAC.Either one or two on a single IDNet communications channel.Each output NACs,from either the same,or from different host fire NAC can be individually controlled for general alarm or alarm control panels,can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs.Multiple control address per Extender.Individual Extender NACs can also selections provide flexible operation.(Refer to page 4 for be manually controlled from the host panel.IDNet more detail.)Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four,4009 IDNet NAC Extender NACs(or optionally, via IDNet communications. eight NACs)to extend the alarm. Optional ZDNet Repeaters.IDNet communications The 4009 IDNet Extender monitors itself and each of its can be repeated with the optional IDNet Repeater Module output NACs for trouble conditions,including earth or with the optional Fiber Optic Receiver Module.Up to faults.Extenders wired to conventional NACs will 100 of the IDNet channel points can be repeated once indicate a trouble by opening the path to the NAC's (refer to pages 3 and 5 for details).Repeated IDNet end-of-line resistor,but retaining the ability to respond to communications also support the"device level"earth alarms.Individual troubles are also annunciated by LEDs fault location utility of the host panel. located on the 4009 IDNet NAC Extender main circuit board.(Refer to page 7 for more diagnostic information.) Product Selection Standard Models Medd Deeadiios 4009-9201 4009-9202CA* 120 VAC input 4009 IDNet NAC Extender with 4,Class B(Style Y)NACs and 8 A power supply 4009-9301 240 VAC input *ULC listed model Optional Modules (for on-site installation) Mew Doe ripies Cms.eras Additional four point NAC module,rated 1.5 A Special —= > 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B(Style Y), 4009-9808 Dual Class A(Style Z)adapter(for two NAC outputs) Select as required(4 maximum) 4009-9809 IDNet Repeater,output is Class A(Style 6)or Class B(Style 4) Select either an IDNet Repeater or a 4009-9810 Class B(Style 4) Fiber Optic Receiver as required Fiber Optic Receiver 4009-9811 Class A(Style 7 fiber,Style 6 IDNet) 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit Beige trim 1-7/16"wide(78 mm), use if required for 2975-9802 Red trim semi-flush installations Battery Selection (select battery size per system requirements) Medd Desa4Yew Cenwowls 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required,24 VDC 2081-9288 12.7 Ah Battery, 12 VDC operation 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet,two batteries are required,24 VDC operation External Accessories (select per system requirements) Medd Deeeriplios Casweeb 4090-9105 IDNet Fiber Optic Class B(Style 4)operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class A(Style 7)operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4"W x 13-1/2"H x 5-3/4"D (413 mm x 343 mm x 146 mm) 4081 Series End-of-Line Resistor Harnesses;see data sheet S4081-0003 for details 2 S4009-0002-4 2/2006 T •ical IDNet Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring wig requirements,some wiring is not shown.) sr il * '1' IDNet addressable communications channel, ..shown Class B(Style 4) Output NACs,four standard, Conventional NAC operation(horns) eight with expansion option ' A--Select conventional •�•• or SmartSync operation per NAC 4100U(shown)or 4010 Fire Alarm Control Panel _ - 4 SmartSync operation(horns and strobes) 4009 ZDNet NAC Extender with1mit•—• r--111. optional internal IDNet Repeater - Conventional NAC operation(strobes) t Repeated IDNet Channel: --9 il it .mir up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five(5)4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables,3000 ft Output NACs 4090-9105,Class B (914 m)maximum distance 0.11 (Style 4)Output Fiber 11 " `_ Optic Transmitter _O- ;! L.7ig W �� l- 1 R. Pi 111111111 , . ., ZDNet addressable communications Ir--- channel Class B(Style 4)or Class A (Style 6),Class B shown Reoeated ZDNet Channel:up to 100 devices maximum on repeater output,250 devices total on IDNet Channel Four fiber cables,3000 ft 4010 or 41000 Fire (914 m)maximum distance Alarm Control Panel 24 VDC power for fiber optic transmitters =i= e j -- 11 ir- rill 4090-9107,Class A(Style 7) • II VIM 41.r1 Output Fiber Optic Transmitter R 1 ' • 4009 IDNet NAC Extenders with optional Output NACs internal ZDNet Fiber Receivers NOTE: Up to five(5)4009 IDNet NAC Extenders may be connected to one ZDNet channel. IDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009-0002-4 2/2006 r Hardwire Control Connection Information SmartSync Notification Appliance Control NAC Input Selections.The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non-addressable operation. • Track input NAC operation or to provide a locally Non-addressable models are available with 2-wire generated code,selectable per NAC input SmartSync operation or conventional 4-wire operation. • If selected for local coding,NAC outputs can be either The following details apply to use with the 4009 IDNet NAC Extender: Temporal Coded or 60 Beats/min March Time Coded, • TrueAlert non-addressable models with SmartSync one code selection per extender(input NACs must be on3'n continuous with Alarm) operation allow audible notification to be separately controlled over the same wire pair that controls • Additionally,NAC outputs can be selected to provide visible notification(protected under U.S.Patent No. the Simplex strobe synchronization signal.This signal 6,281,789) will synchronize the flashes of synchronized strobes but • 4009 IDNet NAC Extenders can be selected to provide will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs.) communications or conventional NACs NAC input to NAC output control can be selected for • IDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or SmartSync operation Conventional NAC Output Operation Options • With NAC input control,all output NACs are selected A C for either conventional or SmartSync operation boat :. • Class A(Style Z)SmartSync operation requires NAC 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 SmartSync Control Module(SCM)4905-9938(refer to NAC 2 NACs 3&4,7&8 NACs 5-8 None data sheet S4905-0003 for details) SmartSync NAC Output Operation • Refer to data sheet S4009-0003 for TrueAlert lop* -1111ACCalmilamlien addressable operation details,contact your local Simplex NAC 1 Strobe Control product supplier for further information on specific NAC 2 Horn Control All NAC outputs(1-8) TrueAlert notification appliances . Hardwire Control NAC Connection One-Line Reference Diagram Up to eight(8)output NACs total;hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input -.E.—I-. 0 (see Note 1) l� Conventional NACs MI ' 6 THIMIlir --- _-- a , With hardwire control, Output "" NAC outputs all ––––- w Output conventional or all NACs Smarts c o tion en scu 4009 IDNet NAC — — Extender Fire Alarm Control Panel PIM/ PM �'"� with Conventional NACs SmartSync operation 4905-9938 SmartSync Control Module is required NAC 2 input for Class A output wiring of SmartSync NACs (optional,see Note 1) To additional 4009 IDNet NAC Extenders(up to four(4), 4009 IDNet NAC Extenders per NAC);see Note 2 Notes: 1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. NAC 1 is"on-until-reset"and NAC 2 is"on-until-silenced." 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe output from a Synchronized Flash Module(4905-9914 for Class13 operation,4905-9922 for Class A operation)or, if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-4 2/2006 4009 IDNet NAC Extender S•ecifications 120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz Input 240 VAC Input(4009-9301) 1.5A @ 204-264 VAC,50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A,Special Application appliances 6 A,Regulated 24 DC appliance power Standard NACs 2 A each,Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each,Special Application appliances (requires 4009-9807) 1 A each,Regulated 24 DC appliance power Special Application Simplex 4901,4903,4904,and 4906 Series horns,strobes,and combination Output Ratings Appliances horn/strobes and speaker/strobes(contact your Simplex product representative for compatible appliances) Regulated 24 DC Power for other appliances listed to UL Standard 1971 or UL Standard 464; use Appliances associated external synchronization modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized;output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA©24 VDC,system supplied IDNet Input,One Address Maximum distance from IDNet source is 2500 ft(762 m) IDNet Repeater Repeated ZDNet output for up to 100 devices(total IDNet devices not to exceed Module 250 per channel) (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m) Total distance including"T-taps"is 10,000 ft(3048 m) Class A(Style 6)loop maximum distance is 2500 ft(762 m),no'T"taps Fiber Optic Receiver Modules Input Current 4009-9810,Class B(Style 4),65 mA @ 24 VDC,system supplied 4009-9811,Class A(Style 7),80 mA @ 24 VDC,system supplied IDNet Output Specifications Same as those for Repeater Module(see above) Fiber Optic Transmission Distance 3000 ft(914 m)maximum General(LED status indicators are listed on page 7,dimensions and mounting details are on page 6) Operating Temperature 32°to 120°F(0°to 49°C) Operating Humidity Range 10%to 90%RH from 32°F to 104°F(0°C to 40°C) Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Fiber 0•tic Transmitter S•ecifications Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105,Class B(Style 4),30 mA @ 24 VDC 4090-9107,Class A(Style 7),35 mA @ 24 VDC Multimode,graded index,50/125pm,62.5/125 pm, 100/40 pm,or 200 pm Fiber Optic Connections and cable Type ST connectors requirements 4090-9105,Class B(Style 4)operation,two fiber cables required 4090-9107,Class A(Style 6)operation,four fiber cables required Module Size(with mounting bracket) 6-13/16"W x 3-3/4"H x 1-1/8"D(173 mm x 95 mm x 29 mm) Green LED flashing=transmit On-board Status Indicators Red LED flashing=receive Separate red LED on 4090-9107=Class A(Style 7)receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft(914 m)maximum Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Operating Humidity 10%to 90%RH from 32°to 104°F(0°to 40°C) Operating Temperature 32°F to 120°F(0°to 49°C) *Metric wire equivalents: 18 AWG=0.82 mm2; 12 AWG=3.31 mm2 5 S4009-0002-4 2/2006 4009 IDNet NAC Extender Mounting and Module Placement Information I 16-1/4"(413 mm) 'I Cabinet depth I 4-1/4"(108 mm)—1 I6 10-29/32"(277 mm) e I Door,5/8" —�O O o o I— (16 mm)thick-...._.. l G----i G --i Optional Class A 4009-9807 Additional Four 13-1/2" adapter modules point module(shown with (343 mm) 0 ` Class A adapters) 2 ® Exposed cabinet 1 I dimension for—4.' r C System Module J o oL. semi-flush mount r i 1"(25.4 mm), Knockouts for screw 1 f IDNet repeater g, 1-3/8"(35 mm)with or nail mounting holes H \iber optic receiver II semi-flush trim 91 ili V-O O ° o Ii 0 I I co — I ; f4 12"(305mm) ►+ I � I T----------- Battery location,no conduit entry or wiring in l this area(12.7 Ah battery outline shown) iEl I ' : O Ol Semi-flush trim option 1-3/16"wide(30 mm, Non-power limited wiring area(AC input) ) 3/8"(9.5 mm)thick Wall surface reference for semi-flush mount NOTE: Recommended conduit entrance varies with module selection. Refer to general installation _ instructions 574-181,specific module installation instructions,and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail I Optional red applique (4009-9805) 4009 IDNet' NAC EXTENDER Simplex " 11 111 IIIH 6 S4009-0002-4 2/2006 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: 0 0 0 0 0 0 Simplex model 2975-9217 (ordered separately) nnnnnn Flush mount masonry box: ` ' < ' ` use 6-gang box, RACO#960,2-1/2"deep � 0 0 0 0 0 (64 mm),or RACO#965,3-1/2"(89 mm) 0 O O u u u ( O' deep,or equal(supplied by others) e o �:,�1 Iiro•�1 I r��1 —V Flush mount ganged boxes: • • 0 use 6-gang box, 1-1/2"(38 mm) i minimum depth;six, RACO#400C ' C` 7/ or equal,(supplied by others) I♦�- O O A _r_ 1, V 0 0 0 0 0 0 IDNet fiber optic transmitter. 4090-9107,Shown,Class A(Style 7)output 4090-9105,Not shown,Class B(Style 4)output INSTALLATION NOTE: Fiber optic cable bend radius should be 2"(51 mm) minimum,or per Manufacturer's specification. o 0 0 0 0 0 Six-gang blank cover plate Mulberry Metal Products 97156 or equal(by others) Service Diagnostic Features Power-up Self-Diagnostics.Upon power-up,the LED Status Indicators are provided for the following: 4009 IDNet NAC Extender tests each module and • Each NAC(standard and optional)has a dedicated performs earth fault diagnostics.Trouble conditions are yellow LED that: communicated to the host control panel and are also — During supervision provides a slow flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet a short circuit condition and a fast flash to indicate NAC Extender.When connected via IDNet communications,detailed status information is available an open circuit at the host.When controlled with conventional NAC — During an alarm,the LED follows the NAC output inputs,common troubles are signaled by providing a (on steady or flashing with coded output) polarized open circuit that disconnects the NAC wiring • Four, general status yellow LEDs provide nine from its end-of-line resistor but still allows a reversed separate indications listed in priority of urgency.As a polarity alarm to be received. trouble is eliminated,any remaining trouble(s)will Door Mounted Reference Label.The 4009 IDNet then be indicated until the 4009 IDNet NAC Extender NAC Extender has a detailed programming and is returned to normal operation. diagnostic label inside the front door that provides a quick • AC power status is indicated by a green LED that is reference for both installation and checkout. on when AC is normal.During low AC(brownout) conditions or with no AC,the LED is off.Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-4 2/2006 4009 IDNet NAC Extender Current Chart Panel Module Selection (shaded model numbers are optional modules) Medd Diesips Meddiay Ai__w_Crnwwt AietniA� i Consul Swpasinn 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input +NAC loads +NAC loads . Additional Four Point NAC 40 mA + (add below) (add below) Dual Class A Adapter(current _ included in basic panel value) + " s ZDNet Repeater 70 mA 70 mA dessisieFiber Optic Receiver,Class B 65 mA + 65 mA + Fiber Optic Receiver,Class A 80 mA 80 mA ZDNet Devices,0.7 mA each, maximum of 100 Total devices + Total devices + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output,calculate per total 500 mA + 500 mAVal + device requirements(see note 5) maximum maximum Total Supervisory Current= Vel+ Total 4009 IDNet NAC Extender Panel Alarm Current= `lam *Only one of these three modules can be chosen for a single 4009 ZDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads IiACTips c ra9ts MIACAltussiCermit Circuit 1 + Circuit 2 + Standard Panel NACS,2 A maximum per NAC(see note 5) Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum per NAC(see note 5) Circuit 6 + Circuit 7 + Circuit 8 + Total NAC Loads Alarm Current= I Total 4009 IDNet NAC Extender Panel Alarm Current(enter B1 from above)= :PO + Procedure: Total Alarm Current= 114 1. Calculate total panel supervisory current(A). 2. Calculate total panel alarm current(B1)[convert mA to A,example:350 mA=0.35 A].Copy(B1)into block(B2). 3. Calculate total NAC loads alarm current from notification appliance ratings(C). 4. Add(C)+(B2)to determine total alarm current(D). 5. Total of IDNet Device Current(Al)+Auxiliary Power Output Current(A2)+ NAC Loads Alarm Current(C)is 8 A maximum. 6. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements (i.e.24 hours supervisory,5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco,Simplex,the Simplex logo,LtfeAlarm,IDNet,WALKTEST,SmartSync,and TrueAlert are trademarks of Tyco International AG or its affiliates in the U.S.a d/or other countries. Et "x Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4009-0002-4 2/2006 www.tycosafetyproducts-usa-wm.com ®2006 Tyco Safety Products Westminster.All rights reserved All spect cations and other information shown were current as of document revision date and are subject to change without notice. Wheelock r' ExcederTM Series Notification ED ., ry Finally, Design and Safety Meet... FIRE rn wake 'UitlrCNbM •.n ..n..> 3c Description: The Wheelock ExcederTM Series of notification appliances feature a sleek modem design that will please budding owners with reduced Sou u to % in draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test -Up to'9 models now kr 1niphance points,12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. -Sow up to 14% cost of mutation** The Wheelock ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single ( Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings,can be set without the use of a tool and are located behind the appliance to prevent tampering. cij Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Excedeerm Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting 12/24 Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a r')) so,95,ss dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 160 8 Candela Settings;s' it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra r � Universal Mounting Base"' secure installation, while the ceiling models provide a captivated " ceiling and wall Mounts to 5 E3acklwx Types screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requitement. -Synctventze using the Wheelock Sync Modules or panels with built-in Wheelock°Patented Sync Protocol -Compatible with UL`Regulated Voltage'using filtered VDC or u nfitered VRMS input voltage -Strobes produce 1 per second over the`Rued Voltage'range 'Compared to competitive models ""Patented "Compared to previous models NOM All CAUTIONS awl INANNINSEan IdeallEad b Ire symbol L A11 warnIngs acs'WNW ra bola capNaf keels. rt A11041111111Na PLEASE MAD t OE arE lice ot1ssim ASmaNID A1sT/luatoN INSTRUCTIONS CAREL:taw IBORE USING.SPECrivis atitifflilleasyes lNOgUCL Mlflrvormacooralmterecomon.com at COIMMACT COOPER NOT CA lON FOR TIE cum's!'N$TALLRION INIFENICII01111. FAILUNETOCt>pt.YM'l IM1vOFTIHENstRUCnONs.CAUTIONS OR INARININIS COULD new N IMPROPER APPUCAT1ON. 1111011MIONAINIVOR OPERMI0N OF IIt#SE PNOOUCTS N AN EIENBENCY amen"twice COULD soma N PNOPERrY WA!E.M0 slaulatitiouwar an 011M14YOU MOOR MIER . Genoa!No : •Maio are da ipbdbanbat1laalaparaaoaadmiinwnaverteir RepialadVolvo Rupe•. •M candela alma npresaat as aiow aiacsw dabs is n*basad as UL Standard 1971. •Sedeesicirder Strobe meads a sUMW+ardar ULSandal&1971 and 464 for indoor use WA a tas4araa a rase a32 F In 120•F(O C b 48^C)and timidly at 93%(t 294 UL 404($5%UL 1971). •Saha Exam*,hams ane wan LS.Standard 464 far aoU signal applanoas(boor use ah►). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max 24 VDC/24 RNR 12 VDC Model RegulatedVoltage D 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0205 0253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &UL 464 at 24 VDC UL Llai CJrrcr" a' 99 ':EL 24 VDC 12 VDC Modelal ISPA tVoltage t VD 15 15/75 30 60 75 95 110 115 ® 150 177 185 15 15/75 Range© 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0242 0.282 0.125 0.159 8.0-3a0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Crrert' a- 95 :E.,- 24 624 VDC 12 VDC Model Regulated Nottage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max a 24 VDC 12 VDC Model Regulai VD Vuttage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 RanHS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL 464 k Model Regulated VVDC oltage 99 dB 95 dB 90 dBRan HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 "'- HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. 1 • ' Specification &Ordering Infonnation StrobeSync vol SM, Mountivg Model DSM or 12124 VDCCandela Op6on PS-6 S PS-8 ai s S: o --> 0 HSR 15/1575/30/75/95/110/135/185 X X To UMB" O " HSW 15/1575/30!75195/110/135/185 X X o UMB 0 HSRC 15/30/60/75/95/115/150/177 X X v UMB" 73 HSWC 15/30/80175/95/115/1501177 X X UMB" p d U V — > E STR > 15/1575130/75195/110/135/185 X X UMB" CD En C) STW -p 15/1575/30/75/95/110/135/185 X X ri UMB" E STRC ,- 15/30160/75195/115/150/177 X X g UMB" CD STWC = p 15/30/60/75/95/115/150/177 X X � UMB" p N co c p HNR X X a) UMB" T HNW C CV X X " UMB CV HNRC V XX X m UMB" a) W HNWC CO X X ,- UMB" '12 VDC models feature 15&15/75 settings "UMB=Universal Mounting Base Moles Legend . ' k ® A. '@ IN=Hone * '•, _, .......,9 ST =Strobe ; Lx`` HS =Hom Strobe 1 C =Cei ig Moult W =White • R =Red ,e. te. 4"4)>N1?) l .. Example 1: STRC=Strobe,Red,Ceiling Mount lif Example 2: HSR=Horn Strobe,Red,Wall Mount Example 3: HSW=Horn Strobe,White,Wall Mount 0 C") •sIV �, � a Voltage test points for quick 8 candela settings Common base for wall and ceiling viith 5 troubleshooting and easy spot mounting options checking (wall models only) NOTE:Otte to continuous development of our products,spedtiations and offerings are subject to change rrillnout notice in accordant* edits Cooper rMseloek Inc,dire Cooper Noliliation standard terns and conditions. "•Architects and Engineers Specifications The notification appliances shall be Wheelock.ExcederT"Series HS Audible Strobe appliances,Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971(Emergency Devices for the Hearing-Impaired)for Indoor Fre Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fre Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube endosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30,75,95, 110, 135, 185 candela for wall mount and 15, 30,60,75, 95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required(e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang,double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed.Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fre Alarm Control Panel(FACP). The mounting base shall be the same base among all horn,strobe,horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24'H x 4.58'W x 2.19'D. Series HN wall shall measure 5.24" H x 4.58'W x 1.6'D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68'x 2.63'D. Series HNC ceiling shall have a diameter of 6.68'x 1.50'D. When synchronization is required,the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain(1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances-UL Standard 1971,UL Standard 464,California State Fire Marshal(CSFM),ULC,FM Ceiling Appliances-UL Standard 1971,UL Standard 464,California State Fire Marshal(CSFM), ULC,FM MEM Me tuber WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 10/10 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. 4401 Wilson Boulevard, Suite 220 Long Branch, NJ 07740 Sarasota. FL 34243 Arlington,VA 22203 P: 800-631-2148 P: 941-487-2300 P: 877-459-7726 F: 732-222-8707 F: 941-487-2389 F: 703-294-6560 www.coopernotification.com �� Cooper Nour�caoonitWheelock' (', 3 SAFEPATH. WAV )/ Ijr COOPER Notification