Report (29)
-Figs 21.0tS-- (x)(>`/(1 C U 30 S60 5kc>//s -r. SIEMENS 15201 NW Greenbrier Parkway Suite A-4 Beaverton,Oregon 97006 Phone: (503)207-1900 Fax: (503)207-1901 RECEIVED MAR 17 2015 CITY OF TIGARD BUILDING DIVISION FIRE ALARM SUBMITTAL MET Community Center Tigard, OR 97223 Submittal Version Date Siemens Job Number 44op-162768 Issued for Permit 12.04.2014 Review Comments 02.13.2015 Siemens Project Manager Ron Pulioff Siemens Project Engineer Will Chappell Proprietary document for approval only System Overview — (continued) The FireFinder XLS system has been seismic qualified in accordance with: • International Building Code,2006 Edition • • California Building Code, 2007 Edition • ASCE Standard 7,2005 Edition • OSHPD, OSP-0057-10 • OSHPD CAN 2-1708A.5,Rev. 3 • ICC-ES AC 156,effective 1/1/2007 PMI-2 Person Machine Interface 2 System Components PMI-2—> Person Machine Interface 2 A basic FireFinder XLS FACP consists of the following sub- The Person Machine Interface 2(Model PMI-2)is the assemblies: Person Machine Interface(Model PMI-2);Power primary user interface and central microprocessor for the Supply(Model PSC-12);Device Loop Card(Model DLC);Zone FireFinder FACP. Indicating Card(Model ZIC-4A);Card cage(Model CC-5);Inner Model PMI-2 uses large, lighted buttons to prompt users as Door Blank Single Plate(Model ID-SP);CAB-1,CAB-2 or CAB-3 to the next correct system operation that is available enclosures. (Acknowledge,Silence,Unsilence,Audible or Reset). From Optional modules that can be installed with this FACP include: each Model PMI-2,the end-user can Acknowledge events; Card Cage(Model CC-2);Network Interface Card(Model NIC- control the system notification appliance circuits(NACs),and C);8-Circuit Zone Indicating Card(Models ZIC-8B/ZIC-2C); reset the system. Detailed information about the nature and Control Relay Card(Model CRC-6);Output Control Module location of the events can also be displayed. (Model OCM-16);Switch Control Module(Model SCM-8);LED The controller in Model PMI-2 provides all system logic and Control Module(Model LCM-8);Fan Control Module(Model FCM-6);Supervised Input Module(Model SIM-16);Power supervision. Model PMI-2 contains a large,6"(1/4 VGA) Supply Extender(Model PSX-12);Remote Network Interface monochrome LCD display,touch screen and LEDs for (Model RNI);Remote Printer Module(Model RPM);System displaying system status. A sound is made when there is Status Display(Model SSD);Multi-Point Digital Alarm any unacknowledged event from Model PMI-2. The display Communicator(Model MDACT);Two-Module Remote is surrounded by keys that are used to control the displayed Enclosure(Model REMBOX2);Four-Module Remote Enclosure information and to navigate through these screens. Keys (Model REMBOX4). are also provided to obtain and enter"Help"into the menu FireFinder XLS is compatible with a full line of intelligent features of Model PMI 2. initiating devices,highlighted by the FirePrint application- Overlays(available in Spanish,Portuguese and French) specified detectors: Models HFP-11 and HFPT-11. XLS is also provide name in alternate languages for the text found on compatible with the Siemens Fire Safety portfolio of graphics the front of each Model PMI-2. Each overlay is assigned, command centers. respectively,on the outer assembly,when affixed to the display on the user interface. Each overlay assignment is intended for use in combination with the run time,alternate language files found in the l i ;'J � {; ,: • custom-configuration software tool, Zeus. Fire Safety Management Stations-XLS Compatible ' FireFinder XLS Compatibility with Siemens Fire Safety Management Stations !. NN FireFinder XLS panels are compatible with Siemens Fire Safety Management Stations,which provide integrated and reliable FACP monitoring and control of XLS system ZIC-4A-*Zone Indicating Card events—including: Alarm, Trouble, Security and ZIC-4A Zone Indicating Card Supervisory commands. The Zone Indicating Card(Model ZIC-4A) provides four(4) Each management station includes PC-based,color- fully supervised, programmable output circuits for use graphics software designed for use with the XNET on each FireFinder XLS. Model DC-4A supplies four(4) network,offering full control and annunciation. 'Class B'(Style Y)or'Class A'(Style Z)type output circuits, An extensive history log of all XLS-FACP events, as well as power limited to 3.0 amps maximum per circuit. extensive report-generation capabilities, is easily maintained. Additionally, user-programmable function buttons allow site-specific control functions. s Industry, Inc. Building Technologies Division J F i reF i nder XLS Components—(cont.'d) Each circuit for Model ZIC-4A can be independently programmed for use with listed audible or visual notification appliances; listed emergency audio speakers; municipal tie boxes; leased lines,or as releasing circuits. Model ZIC-4A plugs into one(1)slot in the Model CC-5 or Model CC-2 card cage,and has on-board LEDs for system status and troubleshooting. Indication of power,communication, internal operation, and ground-fault conditions are provided,as well as NIC-C Network Interface Card indication of circuit activation or Trouble conditions. NIC-C Network Interface Card The Network Interface Card(Model NIC-C)provides HNET or XNET network communications between enclosures. In addition to the HNET or XNET communication,Model NIC-C provides CAN network communication within an enclosure or external to the enclosure. HNET or XNET communication fp can be wired Style 4 or Style 7, but the CAN network can t a be wired Style 4 only. ZIC 8B/ZIC-2C Zone Indicating Cards When used for HNET communications, Model NIC-C ZIC-8B/ZIC 2C provides communication between enclosures on a single system. The Zone Indicating Card(Model ZIC-8B)provides eight(8)fully When Model NIC-C is used for XNET communications, supervised,programmable output circuits for use on FireFinder XLS. Model ZIC-8B supplies eight(8)'Class B' Model NIC-C provides communication between systems. (Style Y)type output circuits, power limited to 2.0 amps The maximum of XNET Model NIC-C cards on a single maximum per circuit.Each circuit can be independently system (single node) is one(1),for a total of 64 XNET programmed for use with listed audible or visual notification Model NIC-C cards on a peer-to-peer networked system. appliances,or listed emergency audio speakers. Model ZIC- Model NIC-C has diagnostic LEDs that indicate: Card Fail, 8B plugs into one(1)slot in the Model CC-5 or Model CC-2 CAN Fail,HNET Fail,XNET Fail,Ground Fault,Loop'A'Fail and card cage,and has on-board LEDs for system status and Loop'B'Fail. Model NIC-C Card also has LEDs to indicate troubleshooting. Power,Style and Active Networks. Model ZIC-2C mounts directly on Model ZIC-8B,and allows each of the Model ZIC-8B output circuits to be used for _•__. 1110 two-channel voice applications. Indication of power, �+ communication, internal operation,and ground-fault conditions are provided,as well as indication of circuit activation or Trouble conditions. ; 40 HCP •. HCP—>Control Point Module HCP Control Point Module 1. • Model HCP provides an intelligent control point for the ' FireFinder XLS. Model HCP can be programmed as an or ; F i reF i nder XLS Components—(cont.'d) 0,4 .. ,.� • r, 4. - e e • CRC-6—>Controllable Relay Card • CRC-6 Controllable Relay Card MLC—>MXL Line Card[for FireFinder XLS] The Controllable Relay Card (Model CRC-6) is used with MLC - MXL Line Card [for FireFinder XLS] the FireFinderXLSFACP. Model CRC-6 is designed to The MXL Line Card (Model MLC) is an optional card for provide auxiliary control of building functions,such as: the FireFinder XLS panel that supplies two (2) door-holder release,elevator capture,smoke control, lock intelligent analog circuits, utilizing the Model 'I'series; release,etc. Model CRC-6 plugs into one(1)slot in the Model' ID'series; Model' IL'series or Model ' FP'series- Model CC-5 or Model CC-2 card cage. Model CRC-6 type intelligent devices. Model MLC occupies two (2) provides six(6),fully programmable relays. Each relay addresses on the HNET network,and devices connected contains one(1)set of SPDT contacts rated at 4 Amps 30 VDC to the Model MLC circuits are dynamically supervised by /120VAC resistive and 3.5 amps 120VAC inductive (0.6 P.F.) FireFinder XLS through the use of a unique communications protocol. 120 ■- a SIM-16-->Supervised Input Module NRC—> Network Ring Card SIM-16 Supervised Input Module NRC Network Ring Card—Second Generation The Supervised input Module(Model SIM-16) is a Model NRC,which is the 2"d generation of Model NRC,is a remotely located,general-purpose input module. Model networking ring card that transmits single-mode or multi- SIM-16 provides 16 input circuits for remote system mode network communication via fiber-optic or copper monitoring. Each input can be individually programmed lines. Each card uses a'Class A'(Style 7)ring configuration as supervised(dry-contact only)or unsupervised(general- for connection with each FireFinder XLS FACP. purpose input.) Model SIM-16 has two (2) 'Form C'relays. The relays and inputs are programmed using the Zeus One(1)Model NRC(per system node)provides XNET,peer- system software-programming tool. to-peer communication between FireFinder XLS FACPs, allowing a max,64,XLS FACPs to be networked together. II , a II II FCM-6 —> Fan,Motor,Dampers Control Module CDC-4—>Conventional Detector Card FCM-6 Fan, Motor, Dampers Control Module CDC-4 Conventional Detector Card The Fan,Motor,Dampers Control Module(Model FCM-6)is a The Conventional Detector Card (Model CDC 4) is used FireFinder XLS command-console option module that to monitor Siemens Fire Safety conventional detectors provides manual control of building HVAC system fans, on the FireFinder XLS system. Model CDC-4 can be motors,and dampers. Each Model FCM-6 module provides used in applications where conventional detectors are six(6)sets of three(3) push-button switches for manual- more suited than addressable detectors, such as system control. Each switch has three (3),associated hallways or large meeting rooms. Also, Model CDC-4 LEDs to indicate Fan/Damper/Motor status:OFF(Red LED), can be used to upgrade Siemens conventional fire-alarm ON(Green LED), Trouble(Yellow LED). panels to the FireFinder XLS system without requiring detector replacement. s Industry, Inc. Building Technologies Division F i reF i nder XLS Components—(cont.'d) 4sis saw Each Model SCM-8 switch is fully programmable,and may I I I I be used to control speaker circuits and a wide range of I 1 general-system functions such as: All Call,All Evac, IWarden's Page, Speaker,etc. Any number of circuits may! I be grouped and controlled by a single switch. Switch usages and zone groupings are assigned using the CC-2 Card Cage-2 Slots CC-5 Card Cage-5 Slots Zeus system software-programming software. Model CC-5 /CC-2 Card Cages SCM-8 modules are mounted on a hinged panel,as a part of the FireFinder XLS Command Console enclosure. The Models CC-5/CC-2 card cages provide the physical mounting location and all wiring connection points for all fire-and-voice system options cards for the FireFinder XLS IMP: l�: system. Model CC-5 has five(5)slots,while Model CC-2 MID: has two (2)slots. INV MID: All cards plugged into the CC-5/CC-2 card cage communicate with other FireFinder XLS modules via a LCM-8 LED Control Module common data bus.Connectors are provided on the left and LCM-8 LED Control Module right side of the CC-5 to connect a 60-pin cable for The LED Control Module(Model LCM-8) is a FireFinder communications with the FireFinder XLS operator interface, XLS-option module that provides LED annunciation for power supplies and amplifiers modules. FireFinder XLS system activity. Each Model LCM-8 Field wiring to devices and circuits terminates on the contains eight(8)groups of two(2)LEDs-each of which Models CC-5/CC-2 card cages.All cards designed for use can be assigned to desired outputs using the Zeus with the Models CC-5/CC-2 route their field wiring system software-programming tool. terminations to the'top'of the Model CC-5/CC-2 card Eight(8) LEDs are dual-color capable(Red or Green/ cages. These connections are all power limited. Internal flashing or steady). The remaining LEDs are Amber wiring connections distribute 24VDC to cards or high-level flashing or steady. A space is provided for labeling of LED audio signals(depending on application used)connect to functions. The label slides behind a clear,protective the'bottom'of the Model CC-5/CC-2 card cages.These membrane. Model LCM-8 dimensions are identical to connections are all non-power limited. Model SCM-8,and Model LCM-8 is mounted on the same All wiring connections to the Model CC-5/CC-2 card cages hinged panel,as a part of the FireFinder XLS Command are to removable terminal blocks. Terminal blocks are Console enclosure. rated for use with wire sized 12 American Wire Gauge (AWG)to 24AWG. Each connector is numbered to make • 111411111 ""' "` "' "' vassal • wiring terminations to the correct position on the • `, ` terminal block simple in order to reduce potential wiring errors. RNI- Remote Network Interface RNI Remote Network Interface WIN: G IMP; The Remote Network Interface (Model RNI) provides a INN: lam: connection point for use with equipment mounted in a : MIN: remote-lobby enclosure on the FireFinder XLS FACP. Model RNI is used to provide additional input,output and control SCM-8-> Switch Control Module features to the system remotely,via the main FACP. SCM-8 Switch Control Module The Switch Control Module(Model SCM 8)is a FireFinder These additional features may include control switches and indicators: (Models SCM-8, LCM-8 and FCM-6), remote- XLS-option module that provides manual control to the Emergencyemergency paging microphones or telephones: (Models Voice Evacuation System(EVAC)or manual fire-system control. Each Model SCM-8 module provides LVM, FMT),or controls used in graphic annunciators(Models SIM16,OCM-16)or system-status display with the ability to eight(8) momentary push-button switches and 16 acknowledge alarms, silence audibles and reset the light-emitting diodes(LEDs)to indicate their status. system (Model SSD-C-REM). Each switch is assigned two(2)LEDs, as well as a label Model RNI allows The Person Machine Interface to be to indicate the switch's programmed usage. The label mounted in the Model REMBOX2 or Model REMBOX4 slides behind a clear protective membrane. One set of remote lobby enclosure. LEDs assigned to each switch is a dual-colored LED, which is used to indicate what type of signal is active. s Industry, Inc. Building Technologies Division • F i reF i nder XLS Components—(cont.'d) i aI ■ MOW ;� .Y. #. re; 11 HI 11 H 11 11 i, *� '"�" a :11 O 11 N n I$ 11 11 u n ial a PSC-12 -* Power Supply Charger Module PTB—>Power Termination Board PSC-1 2 Power Supply Charger Module PTB Power Termination Board The Power Supply Charger Module(Model PSC-12) is a Model PSC-12 comes packaged with a module called the high-current power supply that provides the FireFinder Power Termination Board (Model PTB). Model PTB is XLS primary-regulated 24VDC power to operate. Model required for operation with Model PSC-12. Model PTB filters PSC-12 is rated at 12Amps(Alarm)/5Amps(Standby),and the power from the incoming AC mains,and distributes has a built-in battery charger,capable of charging up to 100 it to the Model PSC-12 power supply and the optional Model AH batteries. Model PSC-12 is an addressable-intelligent, PSX-12 power-supply extender. microprocessor-controlled module that communicates its Model PTB has an optional connector that can be used during status to the system-operator interface. system installation,commissioning and service to provide Each Person Machine Interface is then able to query the the technician with a place to plug in their laptop PC, if status of the power supply to obtain data regarding required. Model AC-ADPT is an optional accessory cable system-charging current,terminal-loading information, that allows connection on one side to Model PTB,via a ground-fault conditions and more. keyed connector and on the other end directly into to the laptop's transformer. OM Most laptop-computer external power transformers have _, 111 " removable AC power cords,which can be replaced by the 1 wm11s optional Model AC-ADPT to temporarily provide an AC i i i ' power source for laptop-PC usage during system +1 1 installation,service and maintenance calls when needed. II U 1+ U. 1111 11 ,1 - 1 It, Mir ii 44160. PSX-12- Power Supply Extender PSX-12 Power Supply Extender The Power Supply Extender(Model PSX-12)is a high-current, ,,;,, auxiliary power supply that expands the main Model PSC-12 `'s , power supply and battery charger of the FireFinder XLS system with an additional 24VDC power. Model PSX-12 TSP-40A—>Thermal Strip Printer is rated at 12 Amps. TSP-40A Thermal Strip Printer • The Thermal Strip Printer(Model TSP-40A) is designed for use with the FireFinder XLS system. Model TSP-40A acts as an event-logging device, providing a permanent history report of all system activity. Model TSP-40A mounts in the FireFinder XLS Model CAB 1, Model CAB2 or Model CAB3 enclosure, and its printout is RPM- Remote Printer Module visible through a window in the locked-door enclosure. RPM Remote Printer Module Printouts are automatically spooled onto a take-up reel for The Remote Printer Module(Model RPM)provides a tidy,uniformed records storage. means of connecting the FireFinder XLS system to a printer,such as Model PAL-1,for creating a hard copy of system status and configuration reports. Simultaneously, Model RPM provides an output port that can be configured to communicate with external systems. s Industry, Inc. Building Technologies Division F i reF i nder XLS Components—(cont.°d) • • r ' Itaim • i System-Status Display SSD-Series System-Status Display MDACT -a Multi-Point Digital Alarm Communicator Transmitter The System Status Display (SSD-series model displays) MDACT - Multi Point Digital Alarm is a remote LED/LCD display that shows the local status of Communicator Transmitter a FireFinder XLS system. An LED illuminates when Alarm, Supervisory, Trouble,and Security events occur The Multi-Point Digital Alarm Communicator Transmitter on the system. A(4)four-line liquid-crystal display (Model MDACT) is used in FireFinder XLS systems where (LCD)will give details of the event in alphanumeric point identification of Alarm, Supervisory, Security and form. Trouble events is required at Central or Remote Receiving The display can be toggled to display additional events. Stations. An intelligent RS-485 communications protocol Optional remote system control capabilities are transmits all system information to Model MDACT. available. The installer selects the specific event or groups of Models SSD-C,SSD-C-INT,and Model SSD-C-REM have events that are set to transmit from Model MDACT over three(3)additional control buttons to acknowledge phone lines to listed receiving station equipment. In events, silence audible circuits,and reset the system. turn, Model MDACT can transmit point information,via the Amco Ctact ID and thSIA A Mt Plate(Model MOM2-XonMP),MOM-2 card cageprotocol.,andounan XMIing InterfacedeCard are required fore installation. I IC->Interface Isolation Card IIC-Interface Isolation Card • The Interface Isolation Card (Model IIC) is designed to isolate network signals when used with a Model NCC ring configuration,via Model NRC. Model IIC executes the aforementioned isolation by removing the i networkCAB1 -* Single Row Enclosure backplane signals from each Model CC-2 card g g cage. Model IIC also provides one(1) end of CAN CAB1 Single Row Enclosure termination on each side of Model CC-2. Model CAB 1,the smallest of the FireFinder XLS Models SSD-C and SSD-C-INT have an integral keyswitch enclosures, can house a single Model CAB-MP cabinet mountingplate for mountingcard power supplies enables these control buttons to operate. Model cages,po a supe es SSD-C-REM is located within a locked cabinet. and bulk amplifiers. Model CAB1 also has four(4) Therefore, no additional keyswitch is required for mounting slots on the inner door for mounting The Person manual activation of the control buttons. Machine Interface and Model ID-MP switch module brackets. Model CAB1 comes complete with a black back box;black inner and outer doors;a single lock and key set on the outer door;a single, installed cabinet mounting plate(Model CAB-MP),and a single,installed outer door lens plate (Model OD-LP). A red version (Model CAB1-R) is also available. Approximate size: 27" (68.6cm.) high, 26"(66cm.)wide, and 8"(20.3cm.)deep. s Industry, Inc. Building Technologies Division F i reF i nder XLS Components—(cont.'d) CAB-MP Cabinet Mounting Plate The Model CAB-MP cabinet mounting plate provides mounting for a single row of modules in a FireFinder XLS cabinet. Four(4) module spaces are available on Model CAB-MP,which is used to mount the Model CC-5 card cage;the Model CC-2 card cage;the Model PSC-12 power supply;the Model PSX-12 power-supply extender, and the Model ZAM-80/180-zone amplifiers. Enclosure Trim Kits CAB2 Two-Row Enclosure Trim kits are available for all system enclosures for semi- CAB2 Two-Row Enclosure flush mounting applications. Model CAB1-TK(for black The Two-Row Enclosure(Model CAB2) is the mid-sized enclosures)and the Model CAB1 R-TK(for red enclosures) FireFinder XLS enclosure capable of housing up to two fit inside the Models CAB1 and CAB1-R enclosures. (2) Model CAB-MP cabinet mounting plates. The inner Similarly, Models CAB2-TK and CAB-2R-TK fit inside the door has two(2) rows of four(4) mounting slots. Model CAB-2 enclosure,while Models CAB3-TK and CAB3R- The outer door has space for mounting two(2)outer TK fit the Model CAB-3 enclosure. door plates(Models OD-LP,OD-BP or OD-GP),and can be Remote Transponders configured to open from either side. Model CAB2 consists of the Model CAB2-BB back box,the Model The FireFinder XLS system can use remote transponders CAB2-BD black inner and outer door package,and one(1) for mounting additional modules such as amplifiers Model OD-LP lens plate. The outer door has a single lock without requiring A Person Machine Interface or any and key set installed.A red version(Model CAB2R) is also control switches. Special doors are available for systems available. using Model CAB-2 or Model CAB-3 remote transponders. These doors(Models CAB2-XBD and CAB3-XBD)omit the Approximate size is 45" (114.3cm.) high, 26" (66cm.) unused inner door,and come complete with ventilation wide,and 8"(20.3cm.)deep. louvers built into the door. Model CAB2-XBD fits into Model CAB2-BB,and Model CAB3-XBD fits into Model CAB3-BB. Model CAB2-XBD and CAB3-XBD are supplied in black. Red versions(Models CAB2-XRD and CAB3-XRD)are also available. Complete box and door kits are available,Models CAB2-X and CAB3-X. CAB3-*Three-Row Enclosure - CAB3 Three-Row Enclosure Model CAB3,the single largest FireFinder XLS enclosure available,can house a maximum three (3) Model CAB-MP cabinet mounting plates in the enclosure, and three(3) rows of inner-door mounting slots. ID-MP–>Inner Door Mounting Plate The outer door can be configured to open from either ID MP Inner Door Mounting Plate side. Model CAB3 consists of the Model CAB3-BB back The inner door mounting plate(Model ID-MP) is box,the Model CAB3-BD black inner and outer door mounted on the inner door of any given model CAB package,and one(1) Model OD-LP lens plate. The outer enclosure. Model ID-MP plates are used to mount door has two(2) locks and key sets installed. A red switch-control modules (Model SCM-8); LED control version(Model CAB3R) is also available. modules(Model LCM-8),or fan-control modules (Model Approximate size is 63" (160cm.) high, 26" (66.4cm.) FCM-6). wide, and 8" (20.3cm.)deep. Four(4) mounting plates are included in each Model ID- MP. Each mounting plate has four(4)spaces for control voussmosserimpoommiiir} modules,and can hold either four(4) Model SCM-8 modules(one [1] control module space for each } f module); four(4) LCM-8 (one [1]control module space for each module),or two(2) Model FCM-6 modules(two [2] module spaces for each module). CAB-MP-Cabinet Mounting Plate s Industry, Inc. Building Technologies Division III F i reF i nder XLS Components—(cont.'d) ID-MP Inner Door Mounting Plate Combinations are also allowed. Blank spaces in Model ID- MP can be covered using the blank-control-module plate (Model BCM). Up to four (4) Model ID-MP modules can be mounted in a single row on the inner door. OD-BP->Outer Door Blank Plate OD-BP Outer Door Blank Plate The Outer Door Blank Plate (Model OD-BP) is used to cover an entire row on the outer door of a system cabinet. Model OD-BP is used when there is no Person Machine Interface or control modules mounted on the adjacent row of the inner door. One(1)blank plate is included in each Model OD-BP. ID-SP->Inner Door Blank Single Plate ID-SP Inner Door, Blank Single Plate The inner door,blank single plate(Model ID-SP)is used to cover any single-module blank spaces within the inner door where a Person Machine Interface or Model ID-MP is not being used. Up to four(4) Model ID-SP modules OD-GP->Outer Door Grill Plate can be mounted in a single row on the inner door. Two OD-GP Outer Door Grill Plate (2)blank plates are included in each Model ID-SP. The Outer Door Grill Plate(Model OD GP)also covers an entire row on the outer door of a system cabinet, but has four(4)rows of ventilation louvers on it. Model OD-GP is mounted in front of system bulk amplifiers, card amplifiers,or other modules that generate heat. Using Model OD-GP will permit airflow across these modules to aid in heat dissipation. One (1) grill plate is included with each Model OG-GP. BCM -> Blank Control Module Plate BCM Blank Control-Module Plate Remote System Enclosures Model BCM plates can be mounted on a single ID-MP. Models REMBOX2 and REMBOX4 are FireFinder XLS Four(4)blank module plates are included in each system enclosures that are used for remotely mounting Model BCM. inner-door modules,such as: Person Machine Interfaces; switch modules(Model SCM series); Live Voice Modules (Model LVM),and Firefighters'Master Telephone(Model FMT) modules. V "4 41. Models REMBOX2 and REMBOX4 are thinner than regular rl$,s,1 r Model CAB-series of enclosures–just 5 (12.7cm.)deep k. s overall,and are perfect for mounting in limited-space areas OD-LP Outer Door Lens Plate (e.g.–office-complex lobbies or behind a receptionist's OD-LP Outer Door Lens Plate desk). The Outer Door Lens Plate (Model OD LP) is a clear plastic No card cages, power supplies or bulk amplifiers can be mounted in a given Model REMBOX-series enclosure due to lens plate mounted on the outer door of a system their smaller depth. However,Person Machine Interfaces cabinet. Model OD LP is used to allow operators to see and some modulese. the remote network interface the system interface and controls mounted on the inner modules(e.g. module [Model RNI];the output control module[Model door,but restricts access to unauthorized users. The plate OCM-16],and the supervised input module[Model SIM- covers an entire row on the outer door.A single lens plate is included with each Model OD LP. 16])can be mounted in a given Model REMBOX-series enclosure. Due to the depth of Models LVM and FMT, no Model OCM- 16 or Model SIM-16 modules can be used simultaneously with Model LVM or Model FMT. Model REMBOX2 and Model REMBOX4 are designed for flush mounting with no trim kit required. Both enclosures also come with a clear lens plate on the cover. s Industry, Inc. Building Technologies Division Fi reF i nder XLS Components —(cont.'d) ri:11 11111 XLS-MSE2-ADPT-►Enclosure Adapter REMBOX2->Two-Module Remote Enclosures REMBOX2 Two Module Remote Enclosures XLS-MSE2/R-ADPT- XLS MSE-2/R Enclosure Adapter Model XLS-MSE2-ADPT,which must be used in conjunction Model REMBOX2 has two(2)inner-door module spaces, with Model CAB-MP,is an adapter that allows FireFinder and can hold a single Person Machine Interface, up to two XLS cards to be mounted in older-generation MXL Model (2)switch module brackets and one (1) Model LVM. MSE-2 small black enclosures. Combinations are also allowed. Model XLS-MSE2R-ADPT,which must be used in Model REMBOX2 can also mount a single RNI remote conjunction with Model CAB-MP,is an adapter that allows network interface on a bracket included in the backbox. A FireF inder XLS cards to be mounted in older-generation bracket, known as Model REMBOX2-MP,can be used to MXL Model MSE-2R small red enclosures. mount up to four (4) Model OCM-16 output control modules or SIM-16 supervised input modules. Model REMBOX2-MP must be purchased separately. El aim Approximate size of Model REMBOX2 is 14-1/2" (36.8cm.) wide, 18-1/2" (47cm.) high and 5" (12.7cm.)deep. 1111 11111 XLS-MME3-ADPT-*Enclosure Adapters XLS-MME3/R-ADPT-XLS MME-3/R or MBR-2 Enclosure Adapters Model XLS-MME3-ADPT,which must be used in conjunction with Model CAB-MP,is an adapter that allows FireFinder XLS cards to be mounted in older-generation REMBOX4-> Four-Module Remote Enclosures MXL Model MME-3 or Model MBR-2 medium black REMBOX4 Four-Module Remote Enclosures enclosures. Model REMBOX4 has space for mounting four(4)inner-door Model XLS MME3R ADPT,which must be used in modules. Any combination of A Person Machine Interface conjunction with Model CAB MP,is an adapter that allows FireF inder XLS cards to be mounted in older-generation (two-module spaces);switch module brackets; Model MXL Model MME 3R medium red enclosures. LVM, or Model FMT (one-module space each)can be used. Unused module spaces can be covered with Model ID-SP blank plates. Model REMBOX4 can also mount a single, remote network interface (Model RNI)on a ., , `` bracket included in the backbox. A bracket known as Model REMBOX4-MP can be used to mount up to eight(8)output control modules(Model OCM- 16)or supervised input modules(SIM-16). XLS-MLE6-ADPT->Enclosurere Adapter Model REMBOX4-MP must be purchased separately. Approximate size of Model REMBOX4 is 24"(61cm.) XLS-MLE6/R-ADPT-XLS MLE-6/R Enclosure Adapter wide, 18-1/2" (47cm.) high and 5" (12.7cm.) deep. Model XLS-MLE6-ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in older- generation MXL Model MLE-6 large black enclosures. Model XLS-MLE6R-ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in older- generation MXL MLE-6R large red enclosures. s Industry, Inc. Building Technologies Division F i reF i nder XLS Components-(cont.'d) iii E;;;Iii XLS-MSE3-ADPT-*Enclosure Adapters XLS-MSE3/R-ADPT—XLS MSE-3L/R or MSE-3M/R VPM-MP—>VESDA Mounting Plate Enclosure Adapters VPM,VESDA-HLI-KIT and VMP-MP— Model XLS-MSE3-ADPT is an adapter that allows VESDA Interface Equipment FireFinder XLS cards to be mounted in older- The Very Early Smoke Detection Aspiration (VESDA) generation MXL-IQ Model MSE-3L or Model MSE-3M Peripheral Module (Model VPM)and the VESDA High- black enclosure. Level Interface Kit(Model VESDAHLI-KIT)are optional Model XLS-MSE3R-ADPT is an adapter that allows FireFinder XLS modules that work in conjunction to FireFinder XLS cards to be mounted in older- provide bi-directional communication between the generation MXL-IQ Model MSE-3LR or Model MSE- FireFinder XLS FACP and multiple VESDA detection 3MR red enclosure. networks for the following types of VESDA detectors: • LaserCOMPACT • LaserFOCUS • LaserPLUS • LaserSCANNER •• Model VPM allows each FireFinder XLS FACP to XLS-RCC I-ADPT— Enclosure Adapter annunciate'Alert,"Action,"Fire 1,'and'Fire 2'levels, as well as provide'faults'from any zone on a XLS-RCC-1-ADPT—XLS RCC-1 Enclosure Adapter connected VESDA network. Model XLS-RCC1-ADPT is an adapter that allows the The VPM Mounting plate (Model VPM-MP)allows FireFinder XLS Model SSD/-C series remote annunciator mounting one (1) Model VPM and two (2)of Model to be mounted in older-generation Model RCC-1 VESDAHLI-KIT inside a standard FireFinder XLS Model surface-mount enclosure. CAB1, Model CAB2 or Model CAB3 enclosure. Model VPM-MP utilizes two(2) module spaces on a single :1 row of each enclosure. ® _ .. ®1 1111111111 `., •• : t. XLS-RCCI 3F-ADPT-+Enclosure Adapters ' • XLS-RCC13F/R-ADPT—XLS RCC-1 FIR or RCC-3F/R Enclosure Adapters C900V2-4 Dialer-Capture Ethernet Module Model XLS-RCC13F-ADPT is an adapter that allows the C900V2— Dialer-Capture Ethernet Module FireFinder XLS Model SSD/-C series remote annunciator The Dialer-Capture Ethernet Module (Model C900V2) to be mounted in older-generation Model RCC-1 F or links the data output of Model MDACT from the _ Model RCC-3F black, flush-mount enclosure. FireFinder XLS FACP to an Ethernet connection—on a Model XLS-RCC13FR-ADPT is an adapter that allows the local-area network(LAN)or wide-area network(WAN)— Model SSD/-C series to be mounted in older-generation for communication to a central station over the Internet. RCC-1 FR and RCC-3FR, red flush-mount enclosure. Model C900V2 also allows Model MDACT to be optionally linked to the public switched telephone AP • . network(PSTN) for communication to a central station `I, over telephone lines. Temperature and Humidity Range VPM—>VESDA VESDA-HLI-KIT—>VESDA High- FireFinder XLS components are®UL 864 9th Edition Interface Equipment Level Listed for indoor dry locations within a temperature Interface Kit range of 120+/-3°F (49+/-2°C) to 32+/-3°F (0+/- 2°C) and a relative-humidity range of 93+/-2%at a temperature of 90+/-3°F (32+/-2°C). s Industry, Inc. Building Technologies Division Details for Ordering Details for Ordering — (continued) Part Part Model Number Description Model Number Description AC-ADPT 500-633992 Technician Laptop-Power connector NIC-C 500-033240 Network Interface Card BCM 500-033320 Blank control module plate, NRC S54430-A2-A1 Network Ring Card: 2nd Generation [four(4)per package] OD-BP 500-633017 Outer Door Blank Plate C900V2 554430-C13-A2 Dialer-Capture Ethernet Module OD-BP-R 500-634919 Outer Door Blank Plate,red CAB-1 500.633007 Complete Single-Row Cabinet,black OD-GP-R 500-634920 Outer Door Grill Plate,red CAB-1R 500-633728 Complete Single-Row Cabinet,red OD-GP 500-633018 Outer Door Grill Plate CAB1-TK 500-633013 Single-Row Trim-kit Cabinet,black OD-LP 500-633016 Outer Door Lens Plate CAB1R-TK 500-633729 Single-Row Trim-kit Cabinet,red PAL-1 500-692407 4DUL Listed Parallel Printer _ CAB2-BB 500-633009 (2)Two-Row Back Box,black — 599-050092 PMI and GPMI CAB2-RB 500-634941 (2)Two-Row Back Box,red PMI-2 S54430-C1-Al Person Machine Interface 2 CAB2-BD 500-633008 (2)Two-Row Inner&Outer Door set,black PMI-2-SPAN-LAB S54430-C10-Al Spanish Overlay for Model PMI-2 CAB2-RD 500-633755 (2)Two-Row Inner&Outer Door set,red PMI-2-PORT-LAB 554430-C11-Al Portuguese Overlay for Model PMI-2 CAB2-TK 500-633014 (2)Two-Row Trim-kit Cabinet,black PMI-2-FRENCH-L 554430-C12-A1 Canadian[French]Overlay for Model PMI-2 CAB2R-TK 500-633753 (2)Two-Row Trim-kit Cabinet,red Power supply with battery charger CAB2-XBD 500-633768 CAB2 Transponder Door PSC-12 500-033340 [12A @ 24VDC] CAB2-X 599-034252 Complete CAB2 w/Transponder Door Power supply extender [no inner door] PSX-12 500-034120 [12A @ 24VDC] _ CAB2-XRD 500-633792 Medium-Enclosure Transponder Door,red P1B 500-033390 Power termination board [mounts to Model CAB2-RB] REMBOX2 500-633772 (2)Two-module remote lobby enclosure,black CAB3-BB 500-633011 (3)Three-Row Back Box,black CAB3-RB 500-634942 (3)Three-Row Back Box,red REMBOX2R 500-6 50 61 2 (2)Two-module remote lobby enclosure,red CAB3-BD 500-633010 (3)Three-Row Inner&Outer Door set,black a e M CAB3-RD 500-633757 (3)Three-row Inner&Outer Door set,red REMBOX2-MP 500-634211 Mounting plate for Models OCM-16/SIM-16 in Model REMBOX2 CAB3-TK 500-633015 (3)Three-Row Trim-kit Cabinet,blackREMBOX4 500-633914 (4)Four-module remote lobby enclosure,black CAB3R-TK 500-633754 (3)Three-Row Trim-kit Cabinet,red Mounting plate for Models OCM-16/ CAB3-XBD 500-633769 CAB3 Transponder Door REMBOX4-MP 500-634212 SIM-16 in Model REMBOX4 CAB3-X 599-034253 Complete CAB3 w/Transponder Door REMBOX4R 500-650613 (4)Four-module remote lobby enclosure,red [no inner door] RNI 500-033420 Remote network interface module CAB3-XRD 500-633793 Large-Enclosure Transponder Door,red RPM 500-033270 Remote printer module [mounts to Model CAB3-RB] SCM-8 500-033040 Switch module,eight(8)switches CAB-MP 500-633012 Back Box Module Mounting Plate SIM-16 500-034060 Supervised input module CAN Cable SSD 500-034740 System-status display 3 ft.(91.4 cm.)Length required for: CCL 599-634214 SCM/LCM/FCM modules from Models CC-5/CC-2 SSD-C 500-648733 System-status display with control Inner Doors and from Row-to-Row on Model CAB- SSD-INT 500-034740 System-status display with series Inner Doors multi-lingual overlays CC-2 500-633440 Two(2)Slot Card Cage SSD-C-INT 500-034750 System-status display with control CC-5 500-633037 Five(5)slot Card Cage and multi-lingual overlays CDC-4 500-034200 Conventional Detector Card SSD-C-REM 500.634773 System-status display with control for COM-BRK S54430-B7-A1 Communications Bracket remote lobby enclosure CRC-4 500-033250 Controllable Relay Card TSP-40A 500-634933 Thermal-strip printer CSB 500-03 31 30 CAN Sounder Board TSP-XB 500-849949 Brackets for thermal-strip printer DCT-P 500-699291 MDACT Programmer TSP-XC 500-849950 Cables for thermal-strip printer DLC 500-033090 Device Loop Card VPM S54430-F93-A2 VESDA Peripheral Module Fan-Control-Module Switches VPM-MP S54430-F95-A2 Mounting Plate for VESDA FCM-6 500-033140 (ON,OFF,AUTO) Peripheral Module GPMI-UK 500-650066 Software-Upgrade Kit for PMI(vers.1) VESDA-HLI-KIT S54430-F99-A2 VESDA High-Level Interface Kit (to allow global functionality) XLS-MLE6-ADPT S54430-C9-A1 MLE-6 enclosure adapter for XLS,black GPMI-2 554430-C3-A1 Model PMI-2[with GPMI-HW-KEY] XLS-MLE6R-ADPT 554430-C9-A2 MLE-6R enclosure adapter for XLS,red HCP 500-034860 Intelligent Control Point Module MME-3 and MBR-2 enclosure adapters for HLIM 500-033170 Line-Isolator Module XLS-MME3-ADPT 554430-C8-A1 FireFinder XLS,black ID-MP 500-633027 Inner-Door Enclosure Mounting Plate, XLS-MME3R-ADPT S54430-C8-A2 MME-3R enclosure adapter for XLS,red [four(4)per package] XLS-MSE2-ADPT S54430-C7-Al MSE-2 enclosure adapter for XLS,black ID-SP 500-633028 Single-Module Inner-Door Enclosure XLS-MSE2R-ADPT 554430-C7-A2 MSE-2R enclosure adapter for XLS,red - Mounting Plate,[two(2)per package] MXL-IQ MSE-3L and MSE-3M enclosure adapters IIC 500-850328 Interface Isolation Card XLS MSE3-ADPT 554430-C14-A1 for XLS,black LCM-8 500-033100 LED Annunciator Module XLS-MSE3R-ADPT S54430-C14-A2 MXL-IQ MSE-3LR&MSE-3MR enclosure (eight(8)LED sets] adapters for XLS,red MDACT 500-699254 Multi-Point Digital-Alarm XLS•RCC1-ADPT 554430-Z14-Al RCC•lenclosure adapter for XLS-SSD,black_ Communication Transmitter XLS-RCC13F-ADPT 554430-Z13-A1 RCC-1F&RCC-3F enclosure adapters,black MLC 554431-B4-A1 MXL Addressable-Device Line Card XLS-RCC13FR-ADPT S54430-Z13-A2 RCC-1FR&RCC-3FR enclosure adapters,red MOM2-XMP 500-634822 Mounting Plate for Model MOM-2 ZIC-2C 500-648671 (2)Two-channel adapter card, MXL Module Card Cage via(Model ZIC-8B) MOM-2 500-892766 [one(1)full slot] ZIC-4A 500-033050 (4)Four-circuit zone indicating card ZIC-8B 500-648670 (8)Eight-circuit zone indicating card Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road s Industry, Inc. Florham Park,NJ 07932 East Oakville,Ontario September 2014 Building Technologies Division Tel:(973)593-2600 [511-F5) L6HOH6/Canada Supersedes sheet dated 2/14 FAX:(908)547-6877 Printed in U.S.A. Tel:[905]465-8000 (Rev.131 URL:www.usa.Siemens.com/Fire URL:www.Siemens.CA SIEMENS Data Sheet Fire Safety&Security Products FireFinderTM XLS Fire Alarm Enclosures & Equipment Models: CAB1,CAB-BATT,CAB-BATT-R,CAB2-BB,CAB2-BD,CAB3-BB,CAB3-BD,CAB-MP, ID-MP, ID-SP, ID-FP, BCM,OD-LP,OD-BP,OD-GP, REMBOX2, REMBOX4,XLS-MLE6-ADPT, XLS-MME3-ADPT,XLS-MSE2-ADPT,XLS-MSE3-ADPT and XLS-RCCI3F-ADPT ARCHITECT AND ENGINEER SPECIFICATIONS • One(1),two(2),and(3)three-row enclosures for the FireFinder XLS system • Blank plates for inner and outer doors • Lens and grill plates for outer door • ®UL 864 9th Edition Listed and®ULC Listed; FM, CSFM & NYMEA Approved 11111 CAB1 CAB2 CAB3 Product Overview Enclosures, Doors & Plates The FireFinder XLS fire alarm enclosures (Models CAB1 —Single-Row Enclosure CAB1, CAB2, and CAB3) and their accessories Model CAB1,the smallest of the FireFinder XLS provide a complete set of hardware for mounting enclosures, can house a single Model CAB-MP all FireFinder XLS main system and remote cabinet mounting plate for mounting card cages, transponder cards and modules. power supplies and bulk amplifiers. Model CAB1 The hardware allows the FireFinder XLS system to also has four(4) mounting slots on the inner door for be configured for a wide variety of applications, mounting a Model PMI interface and Model ID-MP and allows for future system upgrades. Included in switch module brackets. the enclosure series are backbox and door sets, Model CAB1 comes complete with a black back box, removable mounting plates and clear lenses, with black inner and outer doors, a single lock and louvered ventilation grill plates,and blank plates for key set on the outer door,and a single OD-LP outer use with the enclosure doors. door lens plate (installed). A red version (Model All enclosures come with ground straps for the inner CAB1-R) is also available.Approximate size is 27" and outer doors, shield termination lugs, (68.6cm.)high, 26"(66cm.)wide,and 8"(20.3cm.) grounding lugs, and tie wrap lances for securing deep. wire. All enclosures can also mount system backup batteries up to 31 AH in capacity. FireFinderTM XLS Enclosures 6327 SIEMENS Industry, Inc. Building Technologies Division I- Enclosures, Doors & Plates—(cont.'d) Enclosure Trim Kits Trim kits are available for all system enclosures for semi-flush mounting applications. Model CAB1-TK (for black enclosures)and Model CAB1 R-TK(for red enclosures)fit Models CAB1 and CAB1-R enclosures. Similarly, Models CAB2-TK and CAB2R-TK fit the Model CAB2 enclosure, and Models CAB3-TK and CAB3R- CA61 Enclosure TK fit the Model CAB-3 enclosure. CAB2–Two-Row Enclosure Door Remote Transponders Model CAB2 is the mid-sized FireFinder XLS enclosure The FireFinder XLS system can use remote transpon- ders for mounting additional modules such as capable of housing a maximum two (2) Model CAB-MP amplifiers without requiring a Model PMI or any cabinet mounting plates. The inner door has two (2) control switches. Special doors are available for rows of four(4) mounting slots. The outer door has systems using Model CAB2 or Model CAB3 remote space for mounting two(2)outer door plates(Models OD- LP,OD-BP or OD-GP). The outer door can be configured transponders. These doors, Models CAB2-XBD and to open from either side. Model CAB2 consists of the CAB3-XBD,omit the unused inner door and come Model CAB2-BB back box;the Model CAB2-BD black inner complete with ventilation louvers built into the and outer door package, and one(1) Model OD-LP lens door. Model CAB2-XBD fits on Model CAB2-BB,and plate.The outer door has a single lock and key set Model CAB3-XBD fits on Model CAB3-BB. The installed. Red doors are available in Model CAB2-RD. transponder doors are supplied in black. Additional door mounting plates must be ordered Complete box and door kits are available as Models separately. Approximate size is 45"(114.3cm.) high, 26" CAB2-X and CAB3-X. (66cm.)wide,and 8"(20.3cm.)deep. CAB2 Enclosure CAB3–Three-Row Enclosure CAB2-XBD Door CAB3-XBD Door Model CAB3,the largest single FireFinder XLS enclosure OD-GP–Outer-Door Grill Plate available,can house a maximum three(3) Model CAB-MP Model OD-GP also covers an entire row on the outer cabinet mounting plates in the enclosure, and three door of a system cabinet, but has four rows of ventilation (3) rows of inner door mounting slots. The outer door louvers on it. Model OD-GP is mounted can be configured to open from either side. Model in front of system bulk amplifiers, card amplifiers, CAB3 consists of the Model CAB3-BB back box;the Model or other modules that generate heat. Using Model CAB3-BD black inner and outer door package, and one(1) OD-GP will permit airflow across these modules to aid Model OD-LP lens plate. The outer door has two (2) locks in heat dissipation. A single grill plate is included with and key sets installed. Red doors are available via each Model OG-GP. Model CAB3-RD. Additional door mounting plates must be ordered separately. Approximate size is 63"(160cm.)high, 26" (66cm.)wide, and 8" (20.3cm.)deep. OD-GP Remote System Enclosures Models REMBOX2 and REMBOX4 are FireFinder XLS system enclosures that are used for remotely mounting inner-door modules, such as the Model PMI interface, switch modules, Model LVM live-voice CAB3 Enclosure modules, and Model FMT Firefighters' Master Telephone modules. SIEMENS Industry, Inc. Building Technologies Division Enclosures, Doors & Plates—(cont.'d) 1111 REMBOX4 are FireFinder XLS system are thinner than the regular CAB enclosures(just 5"deep overall),and are perfect for mounting in places where space is limited (such as lobbies or behind a receptionist's desk). Due to their smaller depth,no card cages,power supplies or bulk amplifiers can be mounted in a REMBOX. However, modules such as the Remote Network Interface Module REMBOX4 REMBOX4 (Model RNI);the Output-Control Module(Model OCM-16) (with doors closed) (with doors open) and the Supervised Input Module(Model SIM 16)can be Note:A red,(4)four-module remote lobby enclosure mounted in a REMBOX. Due to the depth of the live-voice (Model REMBOX4R)is also available. module and the firefighters'master telephone,no Model CAB-MP—Cabinet Mounting Plate OCM-16 or Model SIM-16 modules can be used The cabinet mounting plate(Model CAB-MP) provides simultaneously with Model LVM or Model FMT. mounting for a single row of modules in a FireFinder Both Models REMBOX2 and REMBOX4 are designed for XLS cabinet. Four(4)-module spaces are available on flush mounting with no trim kit required. Both enclosures Model CAB MP. Model CAB-MP is used to mount the Model also come with a clear lens plate on the cover. CC-5 card cage, the Model CC-2 card cage, the Model PSC-12 power supply,the Model PSX-12 power supply REMBOX2—Two-Module Remote Enclosure extender,and the Model ZAM-80 1180 zone amplifiers. Model REMBOX2 has two(2)inner door module spaces, and can hold a single Model PMI, up to two (2) switch module brackets,one(1)Model LVM live voice module. Combinations are also allowed. Model " xy ` 5 REMBOX2 can also mount a single Model RNI on a bracket included in the backbox. A bracket(Model REMBOX2-MP)can be used to mount up to four(4)Model Ii 3 - ' t t t i t OCM-16s or Model SIM-16 enclosures. Model REMBOX2- MP must be purchased separately. Approximate size of cnB-Mr Model REMBOX2 is 14-1/2"(36.8cm.)wide, 18-1/2" ID-MP—Inner Door Mounting Plate (47cm.) high and 5"(12.7cm.)deep. The inner door mounting plate (Model ID-MP) is mounted on the inner door of a CAB enclosure. Model ID-MP plates are used to mount Model SCM-8 switch control modules; Model LCM-8 LED control modules,or with Model FCM-6. Four(4) mounting plates are included in each Model ID- MP. Each mounting plate has four(4)spaces for control modules,and can hold either four(4) Model SCM-8 modules{one [1] control module space each};four(4) Model LCM-8 modules{one [1] control module space REMBOX2 REMBOX2 each};or two(2) Model FCM-6 modules{two [2] module (with doors closed) (with doors open) Note: A red,(2)two-module remote lobby enclosure spaces each}. Combinations are also allowed. Blank (Model REMBOX2R) spaces in Model is also available. REMBOX4— Four-Module Remote Enclosures ID-MP can be covered using the Model BCM blank control module plate. A maximum four (4) Model Model REMBOX4 has space for mounting four(4)inner door ID-MP plates can be mounted in a single row on the modules. Any combination of Model PMI (two-module inner door. spaces), switch module brackets, Model LVM or Model FMT(one-module space each) can be used. Unused module spaces can be covered with Model ID-SP blank plates. Model REMBOX4 can also mount to a single Model RNI on a bracket included in the backbox. A bracket known as Model REMBOX4-MP can be used to mount a maximum eight(8) Model OCM-16s or Model SIM-16s. Model REMBOX4-MP must be purchased separately. Approximate size of Model REMBOX4 is 24"(61 cm.) wide, 18-1/2" (47cm.) high and 5" (12.7cm.)deep. ID-MP SIEMENS Industry, Inc. Building Technologies Division XLS-MSE2/R-ADPT—XLS MSE-2/R Enclosure Adapter Enclosures, Doors & Plates—(cont.'d) ID-SP—Inner-Door Single Blank Plate Model XLS MSE2 ADPT, which must be used in Model ID-SP is used to cover any single module blank conjunction with Model CAB MP, is an adapter that spaces on the inner door not used to mount the Model allows FireFinder XLS cards to be mounted in older- PMI or a Model ID-MP. Up to four(4) Model ID-SP plates generation MXL Model MSE-2 small black enclosures. can be mounted in a single row on the inner door.Two(2) Model XLS-MSE2R-ADPT, which must be used in blank plates are included in each Model ID-SP. conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in older- generation MXL Model MSE-2R small red enclosures. 1111 111 ID-SP ID-FP—Inner-Door Full Blank Plate 11111 Model ID-FP,which is a blank plate that covers the full XLS-MSE2-ADPT opening of the row on an inner door, is used for XLS-MME3/R-ADPT—XLS MME-3/R or MBR-2 applications requiring full dead-front protection. Enclosure Adapters A single full blank plate is included with Model ID FP. Model XLS-MME3-ADPT, which must be used in BCM —Blank Control Module plate conjunction with Model CAB-MP, is an adapter that Model BCM is used on Model ID-MP to cover any blank allows FireFinder XLS cards to be mounted in older- areas where control modules are not used. A maximum generation MXL Model MME-3 or Model MBR-2 four(4) Model BCM plates can be mounted on a single medium black enclosures. Model ID-MP. Four(4), blank-module plates are included Model XLS-MME3R-ADPT, which must be used in in each Model BCM. conjunction with Model CAB-MP, is an adapter that 11111 allows FireFinder XLS cards to be mounted in older- generation MXL Model MME-3 R medium red enclosures. BCM 1111 1111 11 OD-LP—Outer Door Lens Plate a El Model OD-LP is a clear plastic lens plate mounted on the outer door of a system cabinet. Model OD-LP is used to allow operators to see the system interface and XLS-MME3-ADPT controls mounted on the inner door, but restricts access XLS-MLE6/R-ADPT—XLS MLE-6/R Enclosure Adapter to unauthorized users. Model OD-LP covers an entire Model XLS-MLE6-ADPT, which must be used in row on the outer door. A single lens plate is included conjunction with Model CAB-MP, is an adapter that with each Model OD-LP. allows FireFinder XLS cards to be mounted in older- OD-BP—Outer-Door Blank Plate generation MXL Model MLE-6 large black enclosures. Model OD-BP is used to cover an entire row on the Model XLS-MLE6R-ADPT, which must be used in outer door of a system cabinet. Model OD-BP is used conjunction with Model CAB-MP, is an adapter that when there is no Model PMI or control modules mounted allows FireFinder XLS cards to be mounted in older- on the adjacent row of the inner door. A single blank generation MXL MLE-6R large red enclosures. plate is included in each Model OD-BP. IIII • III III OD-BP XLS-MLE6-ADPT SIEMENS Industry, Inc. Building Technologies Division Enclosures, Doors & Plates —(cont.'d) Details for Ordering XLS-MSE3/R-ADPT—XLS MSE-3UR or MSE-3M/R Model Part Enclosure Adapters Number Number Description Model XLS-MSE3-ADPT is an adapter that allows FireFinder XLS cards to be mounted in the older BCM 500-033320 Blank control module plate, four[4]per package generation MXL-IQ Model MSE-3L or Model MSE-3M CAB-1 500-633007 Complete single-row cabinet,black black enclosure. CAB-1R 500-633728 Complete single-row cabinet,red Model XLS-MSE3R-ADPT is an adapter that allows Model TK 500-633013 Single-row trim-kit cabinet,black FireFinder XLS cards to be mounted in the older CAB1 R-TK 500-633729 Single-row trim-kit cabinet,red CAB2-BB 500-633009 (2)Two-row back box,black generation MXL-IQModel MSE- LR orModel MSE-3MR 3CAB2-RB 500-634941 (2)Two-row back box,red red enclosure. CAB2-BD 500-633008 (2)Two-row inner&outer door set,black 1 CAB2-RD 500-633755 (2)Two-row inner&outer door set,red 1111 1;;;11 IIII CAB2-TK 500-633014 (2)Two-row trim-kit cabinet,black CAB2R-TK 500-633753 (2)Two-row trim-kit cabinet,red CAB2-XBD 599-633768 CAB2 transponder door CAB2-X 599-034252 Complete CAB2 w/transponder door [no inner door] CAB3-BB 500-633011 (3)Three-row back box,black I XLS-MSE3-ADPT CAB3-RB 500-634942 (3)Three-row back box,red XLS-RCC-I-ADPT—XLS RCC-1 Enclosure Adapter CAB3 BD 500-633010 (3)Three row inner&outer door set,black CAB3-RD 500-633757 (3)Three-row inner&outer door set,red Model XLS-RCC1-ADPT is an adapter that allows the CAB3-TK 500-633015 (3)Three-row trim-kit cabinet,black FireFinder XLS Model SSDI-C series remote annunciator CAB3R-TK 500-633754 (3)Three-row trim-kit cabinet,red to be mounted in the older generation Model RCC-1 CAB3-XBD 599-633769 CAB3 transponder door surface-mount enclosure. CAB3-X 599-034253 Complete CAB3 w/transponder door [no inner door] • CAB BATT 500-633917 Field-mounted enclosure for 100AH batteries,black - CAB-BATT-R 500-634925 Field mounted enclosure for 100AH batteries,red CAB-MP 500-633012 Back box module mounting plate •• ID-FP 500-633029 (4)Four module inner-door blank plate XLS-RCC1-ADPT ID-MP 500-633027 Inner door enclosure mounting plate, four[4]per package XLS-RCC13F/R-ADPT—XLS RCC-1 F/R or RCC-3F/R ID-SP 500-633028 Single-module inner-door enclosure Enclosure Adapters mounting plate[two(2)per package] OD-BP 500-633017 Outer door blank plate Model XLS-RCC13F-ADPT is an adapter that allows the OD-BP-R 500-634919 Outer door blank plate,red FireFinder XLS Model SSDI-C series remote annunciator OD-GP 500-633018 Outer door grill plate to be mounted in the older generation Model RCC-1 F or OD-GP-R 500-634920 Outer door grill plate,red Model RCC-3F black, flush-mount enclosure. OD-LP 500-633016 Outer door lens plate REMBOX2 500-633772 (2)Two-module remote lobby enclosure,black Model XLS-RCC13FR-ADPT is an adapter that allows the REMBOX2R 500-650612 (2)Two-module remote lobby enclosure,red Model SSD/-C series to be mounted in the older REMBOX2-MP 500-634211 Mounting plate for Models OCM-16/ generation RCC-1 FR red and RCC-3FR red flush-mount SIM-16 in Model REMBOX2 REMBOX4 500-633914 (4)Four-module remote lobby enclosure,black enclosure. REMBOX4R 500 650613 (4)Four-module remote lobby enclosure,red REMBOX4-MP 500 634212 Mounting plate for Models OCM 161 MME-3 and MBR-2 enclosure adapters SIM-16 in Model REMBOX4 XLS-MLE6-ADPT S54430-C9-A1 MLE-6 enclosure adapter for XLS,black XLS-MLE6R-ADPT S54430-C9-A2 MLE-6R enclosure adapter for XLS,red XLS-MME3-ADPT S54430-C8-A1 for FireFinder XLS,black XLS-MME3R-ADPT S54430-C8-A2 MME-3R enclosure adapter for XLS,red XLS-RCC13F-ADPT XLS-MSE2-ADPT 554430-C7-A1 MSE-2 enclosure adapter for XLS,black XLS-MSE2R-ADPT S54430-C7-A2 MSE-2R enclosure adapter for XLS,red Temperature and Humidity Range XLS-MSE3-ADPT 554430-C14-A1 MXL-IQ MSE-3L and MSE-3M enclosure adapters for XLS,black Products are®UL 864 90 Edition listed for indoor 1 dry MXL-IQ MSE-3LR&MSE-3MR enclosure locations within a temperature range of 120+/-3°F XLS-MSE3R-ADPT 554430-C14-AZ adapters for XLS,red (49+I-2°C)to 32+/-3°F (0+I-2°C)and a relative humidity XLS-RCC1-ADPT 554430-Z14-A1 RCC-1 enclosure adapter,black of 93+I-2%at a temperature of 90+/-3°F (32+/-2°C). XLS-RCC13F-ADPT 554430-Z13-A1 RCC-1F&RCC-3F enclosure adapters,black XLS-RCC13FR-ADP1 554430-Z13-A2 RCC-1 FR&RCC-3FR enclosure adapters,red SIEMENS Industry, Inc. Building Technologies Division Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario Tel: 593-2600 1511-FSI L6T 5E4/Canada October 2011 973 Building Technologies Division ( ) Supersedes sheet dated 8/11 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.7) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 SIEMENS Catalog Sheet Fire Safety&Security Products FireFinder XLS Network Interface Card Model NIC-C ARCHITECT AND ENGINEER SPECIFICATIONS • HNET communications • XNET communications ilftsen 1.. . • CAN network communications form., • Supports Class B-Style 4 or Class A - " Style 7 wiring for XNET or HNET • Supervises the HNET or XNET and CAN networks • Diagnostic LEDs • Isolates short circuit faults • Ground-fault detection • Network repeater Ie . • Downloadable firmware • ®UL 9th Edition Listed &®ULC Listed; FM, CSFM and NYMEA Approved Model NIC-C Model NIC-C (Front View) (Side View) Product Overview The Network Interface Card(Model NIC-C)provides HNET or When Model NIC-C is used for XNET communications, XNET network communications between enclosures. In Model NIC-C provides communication between systems. addition to the HNET or XNET communication,Model NIC-C The maximum XNET Model NIC-C cards on a single system provides CAN network communication within an enclosure (single node)is one(1)-for a total of(59)XNET Model or external to the enclosure. The HNET or XNET can be NIC-C cards on a peer-to-peer, networked system. The XNET wired Class B-Style 4 or Class A-Style 7,but the CAN Model NIC-C card must reside in the same enclosure as the network can only be wired Class B-Style 4. Person Machine Interface(Model PMI). Model NIC-C supervises the XNET network to ensure Specifications proper operation. Model NIC-C also isolates a short-circuit A single Model NIC-C can provide either HNET or XNET fault to each individual segment of the XNET network. communications. The CAN interface is available Model NIC-C provides an electrical repeater for each regardless of the HNET or XNET usage. XNET pair. MXL systems may also reside on the same When Model NIC-C is used for HNET communications, XNET with FireFinder XLS systems. Model NIC-C provides communication between enclosures The FireFinder XLS will also report all events over the within a single system. The maximum HNET Model NIC-C XNET to the Network Command Center for display. cards on a single system (single node)is 50. Model NIC-C Events are displayed on Model NCC-G: Trouble, supervises the HNET network to insure proper operation. Acknowledge,Alarm-Silence and System-Reset Model NIC-C also isolates a short-circuit fault to each commands are also initiated at Model NCC. Model NCC individual segment of the HNET network. Model NIC-C can also be used to perform maintenance commands on provides an electrical repeater for each HNET pair. an individual Fire Finder XLS on the XNET. FireFinder XLS 6338 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Details for Ordering The NIC-C Card takes one card slot and mounts in a Msdsl Por Description CC-2 or CC-5 Card cage inside a CAB-1, CAB-2, or Number Number CAB-3 Enclosure. NIC-C 500-033240 Network Interlace Card The NIC-C provides the CAN network which supports the LCM-81 SCM-8/FCM-6/OCM-161 SIM-16 CAN Temperature and Humidity Range modules. Up to(99)CAN module addresses are Products are®UL 864 9th Edition listed for indoor dry available per enclosure. locations within a temperature range of 120+/-3°F The NIC-C Card has diagnostic LEDs that indicate (49+1-2°C)to 32+1-3°F(0+/-2°C)and at a relative Card Fail, CAN Fail, HNET Fail,XNET Fail, Ground humidity of 93+/-2%at a temperature of 90+/-3°F Fault, Loop-A Fail and Loop-B Fail,as well as LEDs to (32+/-2°C). indicate Power,Style and Active Networks. Electrical Ratings Input Pow Output Power 24V Back Plane Current 120nA Each HNET/XNET 8V peek b peak max. ork Screw Terminal 24V Current 0 And CAN Netw Pai 75mA max.(during meg Ira wr iseion) 6.2V Back Rene Current 0 24V Standby Current 1211mA Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario May 2010 Building Technologies Division Tel:(973)593-2600 Isul L6T 5E4/Canada SuDersedessheet dated 7/09 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.2) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 • SIEMENS Fire Safety BB-55, BB-55R and DE-2, DE-3 Accessory Enclosures ENGINEER AND ARCHITECT SPECIFICATIONS • BB-55 Enclosure Holds 55 A.H. Hour or Smaller Battery Sets • DE-2 and DE-3 Enclosure for Document Storage • Sturdy Welded Construction • T-45 Key and Lock Set Installed • Vented for Heat Dissipation • Available in Black with Siemens Logo • BB-55R is a Red Battery Enclosure • ® Listed Description Ordering Information The Siemens BuildingTechnologies,Fire Safety Division's Model BB-55 and BB-55R are steel battery enclosures with Number Description Part Number sufficient capacity and strength to house 60 A.H. or - 9 BB-55 BatteryBox BTX-2-Black 500 693298 smaller battery sets.The BB-55 is a black enclosure with BB-55R Battery Box BTX-2-Red 500-693484 the Fire Safety logo.The BB-55R is red to meet specific DE-2 Document Enclosure-A size 500-699269 local codes. DE-3 Document Enclosure-D size 500-699270 Both boxes have the same dimensions.The width is For Dimensions of Fire Safety Battery Sets 24 inches to match the enclosure width of our larger see Catalog Number 3361. systems.The enclosures are secured with the same lock set provided on all Fire Safety equipment. The enclosures are constructed for long life and heat dissipation.A top knockout aligns with the bottom knockout in the MXL enclosure.This product is listed by Underwriters'Laboratories for its intended use. The Fire Safety DE-2 and DE-3 can be used to store and secure documents pertinent to the fire alarm system wherever they may be required.This enclosure matches the fire alarm system enclosure in color, logo and key set. CATALOG NUMBER 3326 Dimensions BB-55 and BB-55R [• 24.00(INSIDE) 112-314 KNOCKOUT .4--6.50--► 1.75 7.00 INSIDE 000000000000000000000000000000000000000000000000000 TOP 21.25 >• 1.37 12 PT. t.aa ! UL SIEMENS 1.38 LABEL �. MOOELBBaB • east rn1srr 1111. (it WINO 7.125 e 11.00 I 8.00 INSIDE H 00.437 I ___ . +if1 BACK 25.50 (OUTSIDE) DP I I ; t 12.50 (OUTSIDE) t V FRONT -r - Document Enclosure T 4.00 Outside 1e01001oa10000000e0cn00uo0n0t1ni0110010on0aue0 TOP 14- 26.25 -01 A DE-2=14.25 DE-3=23.625 i i _ V FRONT i NOTICE:The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss,damage,liabilities and/or service problems. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 11/06 Brampton, Ontario Siemens BuildingTechnologiesTel: (973) 593-2600 5M Canada L6T 5E4 FAX: (973)593-6670 SFS-IG Tel: (905) 799-9937 November 2006 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: 1905)799-9858 Supersedes sheet dated 1/04 PS-12550 12 Volt 55.0 AH f Rechargeable Sealed Lead Acid Battery x "' We've Got The Power.' Features • Absorbent Glass Mat(AGM) technology for superior . performance 1 ;7,.--(...40,46e -, • Valve regulated, spill proof construction allows safe -- - „x; operation in any position • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover(UL94-HB) • Integrated ABS carrying handles for ease of movement • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified 9� u Q • U.L. recognized under file number MH 20845 Terminals (mm) Performance Specifications P°•itive Teraina! Nepadve Terminal Voltage 12 volts(6 cells) +I '° IL5 lNominal Capacity • U:Universal terminals: Heavy-duty posts with O 1 N= p O 1 20 hr. (2.75A to 10.50 volts) 55.0 AH 'nut&bolt'fasteners 10-hr. (5.1A to 10.50 volts) 51.0 AH mL:L m mL:gym 5-hr. (8.8A to 10.20 volts) 44.0 AH 3 ;3 1-hr. (30.6A to 9.00 volts) 30.6 AH 15-min.(96A to 9.00 volts) 24.0 AH Physical Dimensions: in(mm) Approximate Weight 36.0 lbs.(16.33 kg) Energy Density(20-hr.rate) 1.64 W-h/in3(100.30 W-h/l) ISpecific Energy(20-hr.rate) 17.65 W-h/Ib(38.91 W-h/kg) W internal Resistance(approx.) 7 milliohms Max Discharge Current(7 Min.) 165.0 amperes O• ® a O Max Short-Duration Discharge Current(10 Sec.) 410.0 amperes _,_t-a_)T n ; Life(%of nominal capacity at 68°F(20°C)) T1 Month 97% pgisigariffw HT H 3 Months 91% 6 Months 83% Operating Temperature Range H-- L I Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) L 9.04(230) W:5.45(138) H:8.15(207) HT 8.98(228) Case ABS Plastic Tolerances are+/-0.04 in.(+/-imm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-1210000A-C height dimensions.All data subject to change without notice. T r r„ire nar a 7 affin l , ,an always rafar t T I.i�st c dd,'^`oar Te•r ',I M a l an Pahl h .d e .ni,wr bs.tr. www.power-sonic.com PwER�I, ;//iSON/C PS-1255012 Volt 55.0 AH Constant Power Discharge Ratings FINAL WATTS PER CELL @ 25° C MODEL VOLTAGE 5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN 175 320 210 184 153 115 87 72 PS-12550 1.70 342 225 190 158 118 89 73 1.67 354 230 194 160 120 90 74 Discharge Time vs. Discharge Current Discharge Characteristics _ 14.0 40 Ambient Temperature 20°C(68°F 15 \ 13.0 - 10 S EEEEE m 12.0 __ • -----".""IN L &lp m 5 Final ' zp 11.0 E voltage I= 2 10.5V \\ A 2.75 E 10.2V \� E 10.0 - 11 S.5 n• ! 1 \ € 9.0 _27.5 c \ Final 55 30 • 9.6v \ 8.0 Voltage I I 110 - C 9.0V 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 10 \ 40°C(104°F) 20°C (68°F) - min _..I..._-h-_.I 0°C (32°F) Discharge Time 5 8.1I 1 i 2.75 5.5 11 27.5 55 110 Shelf Life&Storage Discharge Current(A) 0 100 Charging is not necessay unless p 100%of capaaly Charging is requied. ce 80cha!gng before Cycle Applications:Limit initial current to 16.5A.Charge until battery voltage cc 5°C use is necessary (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 (41°F)J rohepr«wva full capacity. volts until current drops to under 550mA.Battery is fully charged under these r 60 . . conditions,and charger should be disconnected or switched to"float"voltage. `., , _ cnagemat ral ki 40°C 30°C 20°C cap restceDo not "Float"or"Stand-By"Service:Hold battery across constant voltage source of v 40 (104°F) (86°F) (68°F) sietttes reach 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its o I I I this state. own current level and maintain itself in a fully charged condition. V 0 0 2 4 6 8 10 12 14 16 18 20 - Note:Due to the self-discharge characteristics of this type of battery,it is Standing Period(Months) imperative that they be charged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales®power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way•San Diego,CA 92154• USA•Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0309 1M SIEMENS Catalog Sheet Fire Safety& Security Products FireFinder XLS System-Display Status Series Models SSD, SSD-C, SSD-INT, SSD-C-INT and SSD-C-REM ARCHITECT AND ENGINEER SPECIFICATIONS • 4 X40 Backlit LCD displayamigo • . ,; • Event and audile status LEDs • y • Scroll buttons to view additional events • • Local sounder • Supports Style 4 or Style 7 wiring SSD • Built-in transient protection • Mounts in its own enclosure or REMBOX ; • Optional local-system control • Downloadable firmware 3 ©U L 864 9th Edition Listed and®ULC Listed; -- FM, CSFM &NYMEA Approved SSD-C with Control Product Overview The SSD Series System Status Display is a remote LED I LCD The LCD display on the SSD Series display has four rows display that shows the local status of a FireFinder XLS —40 characters for each row. When the FireFinder XLS system. A LED will illuminate when Alarm,Supervisory, system is in its normal supervisory state with no events Trouble and Security events occur on the system. A present,the display will annunciate the system ID four-line LCD will give details of the event in alphanumeric information,along with the date and time. form. The display can be toggled to display additional When an event occurs on the system,the LCD display events. Optional remote-system control capabilities are will show the event type and address, the time of the available.ab e. event, the custom message for that address, the usage ed of the device,and whether the event is acknowledged Specifications or not. Additionally, display the dis la will show the total The SSD Series display has separate LEDs for Alarm, number of all types of events present on the system. Supervisory, Trouble and Security events on the The display has a backlight feature that operates upon FireFinder XLS system. Each LED will flash when receivingany event information or when any operator unacknowledged eventsofthattYpa are present on the buttons are pressed. system. The LED will change to steady, upon A local sounder is included with the SSD Series display acknowledgment of the event. Also,there are two LEDs that operates when any events are displayed on the that indicate the state of audible circuits on the system. The sounder can be optionally disabled system: one LED to indicate that the circuits are through software programming. Pressing any operator active, and one to indicate that the circuits have been buttons will silence the local sounder when an event silenced. is present. FireFinder XLS 6326 Building Technologies Fire Safety&Security Products Specifications — (continued) Details for Ordering The SSD Series display has two display control buttons that Medel Part Description are used to display the next or the previous event Number Number information in the sequence,and a local sounder silence SSD 500-034170 System Status Display button. Programming for the SSD display is done with the SSD-C 500-649733 System Status Display w/control Zeus programming tool. SSD-INT 500-034740 System Status Display w/international language overlays Models SSD-C,SSD-C-INT,and Model SSD-C-REM have three SSD-C-INT 500-034750 System Status Display w/control& additional control buttons for acknowledging events, international language overlays silencingaudible circuits,and resettingthe system.The SSD-C-REM 500-634773 System Status Display w/control for y remote lobby enclosure SSD-C and SSD-C-I NT have an integral key switch that REMBOX2 500-633772 Small remote lobby enclosure enables these control buttons to operate.The SSD-C-REM REMBOX4 500-633914 Large remote lobby enclosure is located within a locked cabinet,so no additional key BCM 500-033320 Blank control module plate switch is required for enabling the control buttons. The SSD Series display is remotely connected to the H- Electrical Ratings Net communication bus from any NIC-C interface in a FireFinder XLS system enclosure using Class B,Style 4 or Typical 200mA(max)at 24VDC Class A,Style 7 wiring. 24VDC is required to run the SSD 24VDC(Nominal) Series display,and it can be provided from a Model PSC- Input Voltage (31VDC max)filtered 12 Power Supply or PSX-12 Power Supply Extender in the FireFinder XLS system enclosure. Power from other Notes: An auxiliary-regulated,power-limited power supply may be used UL Listed 24VDC power sources is also acceptable. to provide power to the 550.The power Supply must be UL approved for Fire-Protection Signaling Application. Be sure to also include the SSD-C in The SSD Series display has screw terminals capable of the battery calculations. supporting 12-to-22-gage wires.The H-Net communication from the FireFinder XLS system can be terminated on the SSD Series display, or may pass Typical 200mA(max)at 24VDC through for communication with other modules. 24VDC(Nominal) Diagnostic LEDs on the SSD Series display indicate Input Voltage (31VDC mm()filtered power and communication status. Notes: An auxiliary-regulated,power-limited power supply may be used to Models SSD,SSD-C,and SSD-C-INT can be mounted in a 2- provide power to the SSD.The power supply must be UL approved for Fire gang electrical box or a 4-inch square electrical box. No Protection Signaling Application. flush-trim kit is required.The unit is approximately 10-112"(26.7cm.)wide, 6-1/8"(15.2cm.) high, and 1-1/2"(3.8cm.)deep. Typical 200mA(max)at 24 VDC The Model SSD-C-REM is mounted in a Model 24VDC(Nominal) REMBOX2 or REMBOX4 Remote Lobby Enclosure,or any Input Voltage (31VDC max)filtered CAB enclosure inner door.The SSD-C-REM requires two Notes: An auxiliary-regulated,power-limited power supply may be used module spaces in the remote lobby enclosure, and its to provide power to the SSD-C-REM.The power supply must be UL/ULC bracket supports the mounting of four inner door approved for Fire Protection Signaling Application. Be sure to also include modules(such as SCM-8s or LCM-8s)below the display.The the SSD-C-REM in the battery calculations. inner door module spaces are arranged in two rows of two module spaces. Products are®UL 864 9th Edition listed for indoor dry locations within a temperature range of 120+/-3°F (49+1-2°C)to 32+/-3°F (0+1-2°C)and at a relative humidity of 93+1-2%at a temperature of 90+1-3°F (32+1-2°C). Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety&Security Fire Safety&Security 8 Femwood Road 2 Kenview Boulevard Building Technologies Florham Park,NJ 07932 Brampton,Ontario Fire Safety&Security Products Tel:(973)593-2600 SFS L6T 5E4/Canada July 2009 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Supersedes sheet dated 8/08 rtes. URL:www.SBT.Siemens.com FIS FAX:(905)799-9858 SIEMENS Catalog Sheet Fire Safety& Security Products MXL, SXL-EX and System 3TM Panels [4] Four-Channel Digital Communicator Models 5128 and 5129 ARCHITECT AND ENGINEER SPECIFICATIONS • Four(4)fully supervised input channels • Dual-phone line interface and line-fault monitoring • Automatic 24-hour test 11181111111151111111anw 1.1 • Reports in eight(8)standard- 5230 �- communication formats • Local-keypad Programmer/Annunciator module (Model 5230) 5129 • Remote programming (Upload/Download) 5128 • Relay output for system Alarm or Trouble • ®UL864 9th Edition Listed; conditions Meets NFPA 72 Chapter 4,for Central Station/Remote Station monitoring • Compact size allows mounting in most control • ®UL Listed as a slave communicator for Cabinets;also available in separate enclosure connection to System 3TM,SXL-EX®and (Model 5129) MXL fire-alarm control panels(FACPs) Product Overview The System 3TM control panel, via the Model CSI-35 Siemens Industry, Inc.—Fire Safety offers the (4) module, provides a combination of contact closures four-channel, dual-line digital communicators and active high voltage input to activate Models (Models 5128 and 5129 by Silent Knight). These 5128 and 5129. The SXL-EX and MXL FACPs use a 'slave'communicators are designed to monitor®UL contact closure for each channel. Listed FACPs. Model 5128 is specifically designed The preset channels are programmed as follows: and listed to be mounted in the System 3TM, SXL Channel 1: Alarm (Fire) EX®and MXL system enclosures. Power from each Channel 2: Trouble(Fire) of the aforementioned FACPs drives Model 5128. Channel 3: Sprinkler Supervisory Programming and troubleshooting time is Channel 4:Alarm (Undefined) minimized by user-friendly English language Phone-Line Monitors messages available with the local programmer Two (2) phone-line circuits detect phone line (Model 5230) and PC-based, remote-downloading g faults bymonitoringtheir voltages. Reporting of a software (Model 5561). 9 P 9 fault as a trouble condition is delayed by 40-90 Specifications seconds. If the condition should persist, an Channel Inputs audible trouble event in either Model 5128 or Four (4) supervised I unsupervised channel inputs Model 5129 communicator will sound, and the can be configured as either voltage inputs;active, trouble event will be reported to the central high or low inputs, or contact closure inputs. station. Models 5128 and 5129 are equipped with line seizure to ensure phone-line accessibility. (4) Four-Channel Digital Communicator 4000 SIEMENS Industry, Inc. Building Technologies Division • •_ Specifications - Specifications — (continued) Technical Data Test Functions Input-24 VDC from t1UL Listed After power-up,the Models 5128 and 5129 self- Electrical: fire alarm control panel(FACP) test system status. A'watchdog'circuit on the Maximum DC Load: Standby-84mA microprocessor resets the communicator if a Alarm-154mA failure occurs. Additionally,a 24-hour auto test AC Monitoring Input: AC Trouble output from Model CSI-35 can be programmed to a central station at a of the System 3TM panel preciseFtime. The installer can also initiate a 4 VDCrm / 4t 1AC f mp; Relay Output: 24 VDC 124 VAC for manual test using the Model 5230 programmer. Alarm or Trouble Programming/ DownloadingGreen LED:LDD: PowerPhone-line g g Indicator Lights' Red Phone-line Trouble The LCD keypad programmer(Model 5230) can Yellow LED:Input fault and be temporarily connected to program or system Trouble troubleshoot the on-site communicator. English- Screw terminals for phone line and language messages assist in enteringdata, Connection: relay outputs.Color-coded flying leads g for control-panel inputs changing the 24-hour test time, and describing Communicates via: current conditions. A ring detector on Models • SK 3/1 5128 and 5129 allows one (1)call to download • SK412 3/1 when used with the optional remote- Reporting Formats: • SESCOA SKK FSK SK((41/22 ) programming software and modem, Model 5561. • Radionics BFSK 14 and 23 • SIA 8/SIA20 formats AC Monitoring FCC registration No.: All FACPs—as well as the Model 5128 and 5129 AC6USA-75160-AL-E Telephone communicators—can be programmed to delay Ringer Equivalence: 0.9B transmission of this signal to a central station as Requirements: Type of Jack: RJ31X[two(2)jacks required] required by Underwriters'Laboratories.The - System 3TM transmits this signal via an active high output from the Central Station Interface(Model Details for Ordering - CSI-35). Model Part Number Number Description Mechanical Data Silent Knight 4-Channel,Dual-Line Digital Model 5128 5128 500-693213 Fire Communicator—Internal Dimensions: 8-3/4"H x 4"W x 1-1/4"D 5129 500-693214 Silent Knight 4-Channel,Dual Line Digital Fire Communicator—Remote Enclosure: Vinyl 1 Acrylic,meets tDUL94 VO 5230 500-693215 Programmer I Annunciator with Harness Color: Black 5561 500-693216 Downloading Software I Modern Kit Weight: 2 Lbs. TIK-512 500-293218 Telephone Interface Kit Model 5129 CSI-35 500-892318 System 3TMCentral Station Interface Module Dimensions: 10-3/8"H x 10-1/8"W x 3"D Enclosure: Sheet-metal Cabinet Color: Red Mounting Suggestions Weight: 6 Lbs. System 3TM: Mount in rear of enclosure, or on _ Accessories mounting rails Model 5230: Programmer/Annunciator with harness SXL-EX: Mount on inside front door below viewing Model 5561: Downloading Software/Modern Kit window, or left-side back box - Telephone Interface Kit—includes MXL: Mount on inside of Model MHD-2 or Model Model 5128: RJ-31 X block and cord(3 ft.)with spade MSR-1 rail kit connectors Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 511-Fs L6T 5E4/Canada SUveAugustsheet2010dated 1iw FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Rev.t) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 SIEMENS Data Sheet Fire Safety& Security Products Intelligent Detection Devices Photoelectric Smoke Detector Model FDO421 ARCHITECT AND ENGINEER SPECIFICATIONS • Compatible with Siemens Model'H'-series devices on the same loop (with Model FC20—series fire-alarm control panels) • Compatible with Model DPU(device programmer/loop tester) • Utilizes advanced microprocessor-based signal processing • Extended temperature and humidity operating range • Each detector is self-testing: ~F • self monitored for sensitivity within®UL Listed limits • complete diagnostics performed every 10 seconds • Polarity insensitive utilizing SureWireTMtechnology , • Compatible with Model DB-11—series mounting bases • Tri-color detector status LED with 360°viewing • Field-selectable application sensitivity profiles • Remote sensitivity-measurement capability • Utilizes advanced signal processing • Automatic environment compensation • Superior EMI/RFI immunity • ®UL268A Listed [for direct air-duct use], • RoHS compliant ®ULC Pending;CSFM Approved Product Overview The Model FD0421 Photoelectric Smoke Detector Model DPU eliminates the need for cumbersome, uses state-of-the-art microcontroller circuitry and unreliable mechanical programming methods—such surface-mount technology for maximum reliability. as dials or switches—and reduces installation and Model FD0421 incorporates an optical sensor using service costs by electronically programming and testing a light-scattering detection principle. The device the detector prior to installation. utilizes advanced software algorithms to analyze the For proper operation of Model DPU,the technician signals,and provides highly stable and accurate selects the accessoys program mode,and enters the smoke detection. desired address. In turn,Model DPU automatically sets Further, Model FD0421 uses state-of-the-art and verifies the address,as well as tests the detector. microprocessor circuitry with error check;detector When in the'test'mode,Model DPU will perform a self-diagnostics,and supervision programs. series of diagnostic tests without altering the address or Field-Device Programmer other stored data,allowing technicians to determine if the detector is operating properly. Model FD0421 is compatible with the Siemens—Fire Model DPU operates on AC power or rechargeable Safety field-device programmer l test unit(Model DPU), batteries,providing flexibility and convenience in which is a compact,portable and menu-driven programming and testing equipment from practically accessory for electronically programming and testing any location. detectors easily and reliably. Photoelectric Smoke Detector 6152 SIEMENS Industry, Inc. Building Technologies Division , Product Overview— (continued) Sensitivity Settings - Model FD0421 is a plug-in,two-wire and addressable Application Parameter Sets photoelectric smoke detector. Model FD0421 is Model FD0421 provides four(4)pre-programmed sensitivity - ®Underwriters'Laboratories Listed parameter sets that can be selected by the FACP to match the [@UL268A Listed for direct in-air duct usage]. expected application or environmental conditions: Each detector consists of a dust-resistant photoelectric • Sensitive chamber;a solid state,non-mechanical thermal sensor,and • Standard microprocessor-based electronics with a low-profile plastic • Robust housing. Every Model FD0421 fire detector is shipped with a •Air-duct protective dust cover: Sensitive: This application parameter set is practically suitable for areas where few misleading sources of false alarm are present,and is appropriate where priority is given to 1 detecting open fires as soon as possible(e.g.—typically a clean application with controlled environmental conditions.) Standard: This application parameter set is practically et_ apt for normal office, hotel-lobby-type applications,and 2 is the default setting. Robust: This application parameter set offers improved t resistance to false alarms in areas where misleading t, sources, such as cigarette smoke or exhaust fumes, may cause a nuisance alarm. 1. Dust cover 2. Thermal detector Air-Duct: This application parameter set is used when - the detector is used a OUL268A(DI)compliant direct in- Operation air duct application without a duct housing. Model FD0421 is a wide-spectrum,photoelectric smoke Model FD0421 does not require a field sensitivity test. - detector incorporating an infrared light-emitting diode(IRLED), Model FD0421 is®UL Listed as a self-testing device and and infrared light-sensing photodiode. Under normal complies with NFPA 72 as a self monitoring detector and conditions,light transmitted by the LED is directed away from control panel arrangement. Additionally,this parameter set the photodiode and scattered through the smoke chamber in a is also used when Model FD0421 is used in air-duct controlled pattern. housings(Models FDBZ492 and FDBZ492-HR). The smoke chamber is designed to manage light dissipation The visible LED flashes green every 10 seconds to indicate and extraneous reflections from dust particles or other non- communication with the FACP,and to notify Model FD0421 smoke,airborne contaminants in such a way as to maintain has passed its self-test. Should Model FD0421 sense a fault stable,consistent detector operation. When smoke enters the or failure within its system,the LED will flash amber,and detector chamber,light emitted from the IRLED is scattered by the detector will transmit the data to the FACP. the smoke particles,and is received by the photodiode: A quick visual inspection is sufficient to indicate the «,-_) condition of Model FD0421 at any time. If more detailed information is required,a printed report can be provided le .1�. from the compatible FACP,indicating the status and �'� settings assigned to each individual detector. When Model If "Iter I � h:,�" FD0421 moves to the alarm mode,the detector will flash Ipiltft .�/ �T o •`tt`I la�� red and continue flashing until the system is reset at the - ��..� FACP. At that same time,any user defined,system alarm ilia", _,1J' functions programmed into the system are activated. 1.Labyrinth Model FD0421 contains a tri-color LED indicator,capable of 2.Optical transmitter flashing any one(1)of three(3)distinct colors: green, , B.Optical receiver or red. During each flash interval,the microprocessor-based detector monitors the following: • Smoke sensitivity is within the range indicated on the nameplate label • Smoke in its sensing chamber • Internal sensors and electronics are functional SIEMENS Industry, Inc. Building Technologies Division • Operation — (continued) Based on the monitoring results,the LED indicator flashes the Should questions arise regarding detector placement,observe following colors based on the following conditions: NFPA 72 guidelines. Good fire-protection system engineering Flash and common sense dictate how and when fire detectors are Flash installed and used. Contact your local Siemens Industry—Fire Color Condition Interval Safety distributor or sales office whenever you need assistance in seconds Normal supervisory operation. applying Model FD0421 in unusual applications. Be sure to Smoke sensitivity is within 10 follow NFPA guidelines and®UL Listed I®ULC Pending rated limits. installation instructions—included with every Siemens—Fire Detector is in trouble and Safety detector—and local codes as for all fire protection Yellow: needs replacement. 4 equipment. Alarm condition. 1 No Flash: Detector is not powered. -- Technical LED can be turned OFF. 1 echnical Data Please follow the corresponding description of the panel used. Operating A quick visual inspection is sufficient to indicate the condition Temperature +32°F (0°C) to 120°F (49°C) of the detector at any time. If more detailed information is Range: required,a printed report can be provided from the Model FC20-series FACPs indicating the status and settings assigned Relative Humidity: 0—95%; non-condensing to each individual detector. Air Pressure: No effect Installation All Model FD0421 detectors use a surface-mounting base, Air Velocity: 0—4,000 ft. 1 min (0-20m 1 sec) Model DB-11 or Model DB-11E,which mounts on a 4-inch Input Voltage Range: 16VDC—30VDC octagonal,square or single-gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self- Alarm Current(max.): 410NA wiping contacts for increased reliability. The Model DB-11 base can be used with the optional Model LK- Standby Current(max): 250pA, max. (average) 11 detector locking kit,which contains 50 detector locks and Maximum Spacing: 30-foot centers (900 sq. ft.), an installation tool to prevent unauthorized removal of the per NFPA 72 detector head. Model DB-11 has decorative plugs to cover the outer mounting screw holes. Detector Weight: Model FD0421 may 9 be installed on the same initiating circuit 0.317 Lbs. (0.144 Kg.) with the following Siemens Model'H'-series detectors[when Mechanical Protection Guard: used with the Model FC20-series of FACPs]— ®UL Listed 1®ULC Pending • Model HFP-11 with STI Guard Model STI-9604 • Model'HMS'-series manual stations • Model'HTRI'-series interfaces • Model HCP output-control devices • Model'HZM'-series of addressable, conventional zone modules Application Data Installation of Model FD0421 detectors requires a(2)two- wire circuit. In many retrofit cases,existing wiring may be used. T-tapping'is permitted only for Style 4(Class B) wiring. Model FD0421 is polarity insensitive,which allows a substantial reduction in installation and debugging time. Model FD0421 can be applied within the maximum 30-feet center spacing(900 sq.ft.areas,)as referenced in NFPA 72. This application guideline is based on ideal conditions— specifically,smooth ceiling surfaces,minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram Details for Ordering Dimensions Model Part Number Number Description N-------4.13" (10.5 cm.) FD0421 S54320-F4-A1 Photoelectric Smoke Detector 9 1 500-094151 Detector Mounting Base 1— DB-1 ,l;5 DB-11E 500-094151E Detector Base{small} :3.11.34" i DB2-HR 554320-F12-A1 Relay Base stomm'mmemmo5. Remote Alarm Indicator: / I RL-HC 500-033230 ‘1.1 Mf ♦ 1 4"octagon-box mount,red RL HW 500-033310 Remote Alarm Indicator: Single-gang box mount,red FACP Compatibility Table FDBZ492 554319-B22-A1 Addressable Air-Duct Housing Mod1l _ FDBZ492-HR 554319-623-A1 Addressable Air-Duct Detector weber with Relay LK-11 500-695350 Base Locking Kit FC2005 50 point panel FC2025 252-point panel In Canada,order: (networkable) . FC2050 504-point panel NIJn)!ber. Number DeSaligicln (networkable) DB-11C 500-095687 Detector Mounting Base for®ULC(pending) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario September 2011 Building Technologies Division Tel:(973)593-2600 (SII-FS) L6T 5E4/Canada New Issue FAX (908)547-6877 Printed in U.S.A. Tel (905)799-9937 URL:www.SBT.Siemens.com/FIS FAX (905)799-9858 SIEMENS Catalog Sheet Fire Safety& Security Products FireFinder XLS & FS-250 Control Panels Intelligent Thermal Detector Model HFPT-11 ARCHITECT AND ENGINEER SPECIFICATIONS • Microprocessor-based design • Rate compensated • Innovative technology provides high-speed, fault-tolerant system/detector communications • Multi-color detector status LED • Polarity insensitive utilizing SureWireTM technology 4111, • Detectors are self-testing: Complete diagnostics every four seconds • Two-wire operation • Compatible with DPU device programmer/tester unit • ®UL and OULC Listed; FM, CSFM & NYMEA Approved Product Overview Model HFPT-11 Intelligent Thermal Detector provides The HFPT-11 thermal detector is®Underwriters Laboratory an advanced method of detection,address and®Underwriters'Laboratory of Canada listed. programming and supervision—combined with sophisticated control-panel communication. Model Specifications HFPT-11 uses a state-of-the-art thermistor that provides Model HFPT-11 is a plug-in,(2)two-wire thermal detector, up to 135°F(57.2°C)rate-compensated temperature. compatible with the FireFinder XLS and FS-250 families of The Intelligent Thermal Detector is compatible with the control panels. Each Model HFPT-11 detector has Device Program I Test Unit(Model DPU). Model DPU microcomputer-chip technology and highly stable, solid-state is a compact, portable and menu-driven accessory electronic circuitry. that makes programming and testing detectors Model HFPT-11 detectors utilize a modern,accurate and shock- fa ster, easier and more reliable than other methods. resistant thermistor to sense temperature changes. Model DPU eliminates the need for cumbersome, This electronic-sensing method virtually eliminates unreliable mechanical-programming methods, thermal lag associated with mechanical temperature- and reduces installation and service costs, via sensing devices, and provides almost instantaneous electronically programming addresses and temperature information to the control panel. Model functionally testing the FPT-11's performance HFPT-11, in its default mode, provides up to 135°F before the detector is installed. (57.2°C)rate-compensated temperature. FireFinder XLS and FS-250 Control Panels 6302 SIEMENS Industry, Inc. Building Technologies Division f Specifications —(continued) Model HFPT-11 can be programmed from the When the user selects the test mode,a series of tests control panel as a fixed temperature detector are automatically conducted and the user is informed without rate-of-rise, at the user's option. whether the detector has passed or failed. Model HFPT-1 1 detector's microprocessor uses Model HFPT-11 detector is compatible on the same an integral EEPROM to store the detector's address. FireFinder XLS or FS-250 initiating circuit with other H- Communications within the detector itself and be- series detectors, HMS manual stations, HTRI-series tween the HFPT-11 and the control panel,or with addressable interfaces,or HZM-series addressable, Model DPU,are supervised and safeguarded against conventional zone modules. disruption by reliable, microprocessor based error Model HFPT-11 detectors use a surface mounting base, checking routines. Additionally, the (Model DB-11), which mounts on a 4-inch octagonal, microprocessor supervises all EEPROM memory square or single gang electrical box. Relay base Model locations, and provides a high degree of EEPROM DB-HR mounts to a 4-inch-square-deep electrical box. failure-fault tolerance. HFPT 11 is listed as a self testing device. Audible base Model ADBH-11 also mounts to a 4-inch- ModelModel HFPT-11's visible light emitting diode(LED) square-deep electrical box. Model DB-11 as well as Models DB-HR and ADBH-11 use screw-clamp terminals for all flashes green every four(4)seconds to indicate it is electrical connections and self-wiping contacts for communicating with the control panel, and to reliability. The bases also contain a provision for an show it has passed its internal self-test. Should optional,concealed locking mechanism to prevent the detector sense a fault or failure within its unauthorized removal of the detector head, Model LK-11. systems,the LED will flash amber,and the detector will transmit that information to the control panel. Application Data A quick visual inspection is sufficient to indicate the The FireFinder XLS and FS-250 control panels use loop condition of the detector at any time. If more circuits with each circuit capable of supporting up to 252 • detailed information is required, a printed report Model HFPT-11 intelligent detectors. can be provided from the FireFinder XLS panel indicating the status and settings assigned to each Locate Model HFPT-11 on the ceiling, at least 4 inches individual detector. from the side walls. For an ideal, smooth ceiling - When Model HFPT 11 moves to the alarm mode, it condition, place the detectors at a maximum center will flash red and continue flashing until the control spacing of 50 feet(2,500 square feet),25 feet from side walls or room partitions. For FM-approved installations, panel is reset. At that same time, any user-defined Model HFPT-11 has a RTI rating of'FAST.' Use a system alarm functions programmed into the system maximum center spacing of 25 feet(625 square feet), are activated. 12.5 feet from side walls or room partitions. A Device Program I Test Unit(Model DPU) is used to Actual job conditions and sound engineering judgment program and verify the detector's address. The user must determine detector spacing. Consider environmental selects the program mode to enter the desired factors including ambient temperature fluctuation,and the address. The DPU Programmer I Test Unit then nature of the fire hazard. Room or area configuration and automatically sets /verifies the address, as well ceiling type(sloped or flat,smooth or beamed)also as tests the detector. dictates placement. Model DPU has rechargeable batteries,which allows a Should questions arise regarding detector placement, detector's address to be programmed by the user follow the drawings provided and/or approved by Siemens from the most convenient location. The user can Industry—Fire Safety Division or by its authorized also separately test the detector for functionality. distributors. SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram Technical Data s_(15.2 ans.)I Operating Temperatures: +32°F(0°C)to DIAMETER BASE 1 00°F (38°C), per®UL 269/268A 011"1 •�~~� Humidity: 0-93%Relative Humidity Non-condensing 23" , Maximum Spacing: 50-foot Centers (2500 Square Feet) 11/7,11 FM-Approved Spacing: 25-foot Centers (625 Square Feet) Current Draw: 1 mA in Alarm or Supervisory mode Removal of Dust Cover without approval from Siemens may void warranty. Details for Ordering Model Part Number Number Description HFPT 11 500-033380 AddressableThermal Fire Detector DB-11 500-094151 Detector Mounting Base DB-HR 500-033220 Relay Base ADBH-11 500-033210 Audible Base RL-HC 500.033230 Remote(red)alarm indicator-octogan box mount RL-HW 500-033310 Remote(red)alarm indicator-single gang box mount LK-11 500-695350 Base Locking Kit for Series 11 detectors In Canada Order. Model Part Number Number Description ADBH-11C 500-033210C Audible Base(ULC) HFPT 11 C 500-033380C AddressableThermal Fire Detector(ULC) DB-11C 500-095687 Detector Mounting Base(ULC) DB-HR-C 500-033220C Relay Base(ULC) SIEMENS Industry, Inc. Building Technologies Division Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 511 L6T 5E4/Canada Juno 2010 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 Supersedes sheet dated 7/09 (Rev.21 URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 SIEMENS Data Sheet Fire Safety&Security Products Intelligent Initiating Devices HMS-Series Models HMS-D, HMS-S ARCHITECT AND ENGINEER SPECIFICATIONS • Durable design • Shock-and-vibration resistant • Pull-down lever is down,until manually reset ch • Reset with Allen Key �N • No break rods necessary FIRE FIRE • Custom microcomputer-chip technology • Dynamic supervision to the fire-alarm control panel(FACP) PUSH HERE 0 .0 • Polarity insensitive via SureWireTM technology THEN • Two-wire operation • Surface or semi-flush installation • Model DPU programs and verifies address PULL DOWN PULL DOWN and tests functionalityof each device l • Electronic-address programming is easier,more SIEMENS SIEMENS efficient and more dependable • Comes in single-action(Model HMS-S)and double-action(Model HMS-D)stations Model HMS-D Model HMS-S • ®UL Listed; Dual-Action Station Single-Action Station FM,CSFM&NYC Fire Dept.Approved Product Overview The Siemens intelligent manual fire-alarm boxes Models HMS-S and HMS-D operate with Siemens— (Models HMS-S and HMS-D)provide the most Fire Safety FACPs. The microcomputer chip to the advanced method of address programming and manual fire-alarm box has the capacity of storing—in supervision. Each Model HMS-series manual box memory—identification information as well as achieves the state of an'intelligent-initiating device' important operating-status data. by incorporating custom microcomputer-chip Innovative technology from Siemens—Fire Safety technology with sophisticated, bi-directional also allows all Model HMS-series intelligent manual communication capabilities with the FACP. fire-alarm boxes to be programmed via the Device Specifications Programmer 1 Test Unit(Model DPU). Model DPU is a Models HMS-S and HMS-D are constructed of compact, portable and menu-driven accessory that . durable, molded polycarbonate material that is matte makes programming and testing of a manual fire finished in red with raised white lettering. The alarm box device faster,easier and more dependable housing accommodates a'pull-down'lever,which— than previous methods. when operated—locks into position;indicating the The programmer I tester eliminates the need for manual fire-alarm box has been activated. mechanical-addressing mechanisms of a device because Model The pull down lever remains down I in the'locked' od DPU electronically o y s et s the address of position, until the fire alarm box is manually reset. the manual fire-alarm box into its microcomputer The manual fire alarm box can only be reset by chip, non-volatile memory. Hence,vibration, opening the hinged housing cover with an Allen key; corrosion and other conditions that can compromise followed by closing and locking the cover. or even deteriorate mechanical-addressing mechanisms are no longer a cause for concern. HMS Series Intelligent Initiating Devices 6306 SIEMENS Industry, Inc. Building Technologies Division • Specifications — (continued) Electrical Ratings _ Models HMS-S and HMS-D are fitted with screw Current Draw(Active or Standby)— 1.5mA terminals for connection to an addressable circuit, and can be either surface or semi-flush mounted. Details for Ordering The Model HMS-series manual fire-alarm boxes Model Part Shipping derive their power,communicate information and Number Number Description Weight receive commands over a single pair of wires. HMS-D 500-033400 Addressable Manual Fire 2.5 Lbs. 1.13 Oz. The Model HMS-series is compatible on the same Alarm Box,Dual Action circuit with all Model'H'-series detectors, interfaces HMS-S 500-033200 Addressable Manual Fire 2.0 Lbs. 0.9 Oz. or addressable, conventional zone modules. Alarm Box,Single Action LTP 500-620490 Reset Tool Package 0.5 Lb. 0.23 Oz. [contains two(2)tools] SB-5R 310-019860 Surface-Mounting Box 1.5 Lbs. 0.7 Oz. Mounting Diagram 1 SURFACE-MOUNTING ENCLOSURE ? '<4 in HOUSING HINGED TO NAMEPLATE SB-5R BACKPLATE c--1-516 i � - AN 00..-- 5-viz in. % Att.A 1 1:411 . ..„...\ - OF l&rikNG � ,, 1 JF a ��- ' •' HOU LOCKING 0 3 m. SCREW \ • BACKPLATE i I )N : 3-1/2 in DEEP (0 0.0.- SWITCH BOX (USER SUPPLIED) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry,Inc. Florham Park,NJ 07932 Brampton,Ontario 3 September 201 Building Technologies Division Tel:(973)593-2600 ism) L6T 5E4/Canada s<o<rs<aembe r 2 13 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (R<,.,4) URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 • SIEMENS Data Sheet Fire Safety&Security Products HTRI-Series Interface Modules Models HTRI-D, HTRI-R and HTRI-S ARCHITECT AND ENGINEER SPECIFICATIONS • Interfacing and supervising normally open(N.0)or normally closed(N.C)contacts • Integral single pole,double-throw(SPDT)relay on Model HTRI-R (upto4amps) • Dual input on Model HTRI-D,using a single address • Polarity insensitive with SureWire m technology • • Multi-color light-emitting diode(LED)indicates system status: • green/amber/red • Easy front access to programming port and wiring terminals .., • Mounts in a 4-inch square,2-1/4"-deep box(or double-gang box) orrMufti • Dynamic supervision • Comes with 5-x-5"faceplate 3� • Two-wire operation • Device Programmer/Tester programs and verifies address of the device and tests for proper functionality • Electronic address programming is easy and dependable •®UL Listed&®ULC Listed; FM,CSFM and NYC Fire Department Approved Product Overview The Siemens—Fire Safety HTRI-series Intelligent The interface module reports the status of the (N.0) interface modules are designed to provide the means or(N.C) contact to the control panel. Model HTRI-S of interfacing direct shorting devices to the fire-alarm can only monitor and report the status of the contact, control panel (FACP) loop circuit. while Model HTRI-R incorporates an addressable The HTRI-series modules provide the most advanced 'Form C' relay. method of address programming and supervision on The Model HTRI-R relayand contact device input are P 9 9 P P the market—combined with sophisticated control controlled at the same address. For the FACP, the panel communication. Each HTRI-series interface relay and input contact can be controlled as a module incorporates a microcomputer chip,and each separate function. The relay is typically used where interface module achieves the state of an'intelligent control or shunting of external equipment is device'through its microcomputer chip technology, required. combined with its sophisticated, bi-directional The Model HTRI-D is a dual-input module that is communication capabilities with the FACP. designed to supervise and monitor two (2) sets of dry Specifications contacts. Model HTRI-D only requires one (1) address, but responds independently to each input. The HTRI-series intelligent interface modules are Model HTRI-D is ideal for monitoring a water-flow available in three(3) models. Models HTRI-S and switch and its respective valve tamper switch. HTRI-R are designed to monitor a(N.0)or(N.C)dry Model HTRI has a multi-color LED that flashes green contact. when operating in Normal;', in ,'if unit is in Trouble condition, and'red'to indicate a change of state. HTRI Series Interface Modules 6304 SIEMENS Industry, Inc. Building Technologies Division Specifications (continued) Mounting Diagram .Model HTRI-D flashes twice—once for each Models HTRI-S, HTRI-D and HTRI-R mount directly into address, and Model HTRI-R LED indicates a change a 4-inch square, 2 '/4-deep box or to a user-supplied of state in the relay. The device's microcomputer double-gang box. A 5-inch square, off-white chip has the capacity of storing, in memory, faceplate is included with each HTRI-series module. identification information;as well as important operating-status information. MOUNTING SLOTS 4-INCH Siemens—Fire Safety innovative technology FOR allows all HTRI-series intelligent interface modules SWITCHBOX to be programmed via the Device Programming I Test Unit: a compact, portable and menu-driven accessory that makes programming and testing J an interface device faster, easier and more dependable than previous methods. (S1 HTRI-S/-D/-R ?a—a; MODULE The programmer 1 tester eliminates the need for 7' mechanical addressing mechanisms, such as: program jumpers, DIP switches or rotary dials, a MOUNTING since Model DPU electronically sets the HTRI- ' HOLES FOR series interface address into the non-volatile SWITCHPLATE memory of the interface microcomputer-chip. Vibration, corrosion and other conditions that of O deteriorate mechanical addressing mechanisms are no longer a cause for concern. The HTRI-series is fitted with screw terminals for connection to an addressable circuit, and is fully MOUNTING SLOTS compatible on the same Siemens FACPs with all FOR DOUBLEGANG intelligent'H'-series detectors, 'H MS'-series SWITCHBOX addressable manual stations, or any other addressable intelligent modules, such as Model Details for Ordering HZM or Model HCP. Model Part Shipping Wgt. All HTRI-series intelligent interface modules are Number Number Description Lb. Kg. ®UL Listed. Environmental operating conditions HTRI-S 500-033370 Single Input 7oz 2 for all HTRI-series modules are 32°F (°C)to 120°F HTRI-R 500-033300 Single Inputw/Relay 7 oz. 2 (49°C)with a relative humidity of no greater than HTRI-D 500-033360 -Dual Input 7 oz 2 93%, non-condensing. Electrical Ratings Current Draw (Active or Standby) 1 mA Model HTRI-R Relay Ratings Resistive: 4 Amps, 125 VAC 4 Amps, 30 VDC Inductive: 3.5A, 120 VAC(0.6P.F.) 3.0A,30 VDC(0.6P.F.) 2.0A, 120 VAC(0.4P.F.) 2.0A, 120 VAC(0.35P.F.) 2.0A,30 VDC(0.35P.F.) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario December 2011 Building Technologies Division Tel:(973)593-2600 (sit) L6T 5E4/Canada Supersedes sheet dated 6/10 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.2) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 Data Sheet Fire Safety Products FACP Accessories PAD-4 Distributed Power Supply Unit Notification Appliance Circuit Extender Models PAD-4-ENCL, PAD-4-MB (with FP2011-U1, FP2012-U1 power supplies) ARCHITECT AND ENGINEER SPECIFICATIONS • Four(4) 'Class B', power-limited notification appliance circuits(NACs) SIEMENS • 'Class A',field-selectable wiring , ■ Each unit can support an optional module(Model PAD-4-CLSA)that C_ - O converts two(2)built-in'Class A'NACs into four(4)'Class A'NACs Class A' • Up to 3 Amps of auxiliary-power output Adapter Card • Optional built-in strobe synchronization [Model PAD-4-CLSA] ■ Supports coded audible signals,including Temporal 3,Temporal 4 patterns • Battery supervision and control • 'Form C'general Trouble/AC Fail monitoring contact papa • Power supplies support NAC power 11111 • Up to 6A used with Model FP2011-U1 Main Board Unit Enclosure ■ [Model PAD-4-MB] [Model PAD-4-ENCL] Up to 9A used with Model FP2012-U1 • 24VDC output voltage • Multi-module mounting in System 3'"'enclosures • Ground-fault detection • Multiple modules share battery set • Advanced microprocessor control • ADA Compliant • Uses Flash memory-based system firmware • ®UL 864 gth Edition Listed,®ULC-S527 Listed; ■ Optional system-diagnostic and firmware-upgrade tool ®UL 1481 Listed (for power supplies)CSFM Approved Product Overview Used with Siemens—Fire Safety fire alarm control The PAD-4 unit provides consistent 24VDC output panels (FACPs),the Distributed Power Supply PAD-4 voltage to each NAC—independent of voltage Unit is a NAC expander with a built-in, auxiliary- fluctuations on the primary or secondary power power output. Each PAD-4 unit distributes source. As a result, a larger voltage drop and a additional power in buildings for audible and visual greater wire length for each NAC are supported by indicators that conform to the Americans with each PAD-4. Disabilities Act (ADA). PAD-4 also has the following features: Specifications • NACs This version of the Siemens Distributed Power Supply PP Y • Signal-input circuits Unit can be configured in the following manner that • Battery charging circuit makes the outputs easily programmable: • Trouble relays for remote monitoring • Diagnostic light-emitting diodes(LEDs) • 'STEADY'outputs • Alternating Current(AC)power connection • Synchronized strobe outputs • American National Standards Institute(ANSI)Temporal 3 The Siemens NACs, which connect with alarm • ANSI Temporal 4[for carbon monoxide(CO)alarm signal] signaling devices, have been designed to provide the highest level of reliability and performance. There are also two (2) inputs used to control the Signal coding on the circuits is accomplished activation of the four (4) outputs. Programming can through integrated circuits (rather than relays), be set so one (1) input will silence the audible signal which eliminates mechanical wear on the output on Siemens Models'AS' series, 'NS' series, or'ZH' circuits. series horn and horn-strobes while the strobes remain active. Distributed Power Supply— NAC Extender (Model PAD-4 series) 3363 s Industry, Inc. Building Technologies Division • Specifications — (continued) Operation of each PAD-4 unit is controlled by Each unit is packaged in its own sheet-metal firmware stored in Flash memory on the main board, enclosure with sufficient space to house up to 7AH as well as the storage of a 10-event log,which can battery sets. The enclosure (Model PAD-4-ENCL) is be viewed via Model PAD-4-FDT. In the event that available in red. an upgrade to the system firmware is required, the The battery charger used in each unit can energize firmware can be transferred to the system without batteries of up to 18AH. Though, when battery sets the replacement of firmware chips. greater than 7AH are required,the battery set must An optional firmware-download software tool, be housed in a System 3 enclosure or a separate Model PAD-4-FDT, can be used for system diagnostic ®UL Listed battery enclosure. testing of the following: System 3 enclosures may also be used to house • Primary-power voltage readouts multiple Model PAD-4 units in a single enclosure, via • Current draw for power charger • Configuration switch settings the Model S3AP Adapter Plate. Two (2) units are • Firmware version capable of sharing the same battery set when • Battery voltage mounted in the same enclosure. Model S3AP can When the tool is in communication with Model PAD- also be used to mount the PAD-4 main board and 4-MB, the'Test Mode'LED is illuminated. Model 170-Watt power supply (Model FP2011-U1) into a PAD-4-LUA is a USB serial port adapter that is PAD-3 enclosure. required for tool-kit operation. Each Model PAD-4 unit complies with seismic Each NAC extender supervises a variety of functions certification, pursuant to the following: including: • ASCE Standard 7,2005 Edition • Low AC power • International Building Code,2006 Edition • Battery-voltage level • California Building Code,2007 Edition • Earth ground fault conditions -■ ICC-ES AC 156,effective 2007 All power can be directed to two (2) 'Class A'or four • OSHPD preapproved,under: OSP-0057-10 (4) 'Class B'power-limited NACs. Each NAC supports - OSHPD CAN 2-1708A.5,Rev.3 up to 3 Amps per circuit. Either one (1) or two (2) Each Model PAD-4-series unit also complies with inputs can control four(4) outputs,which are seismic certification, pursuant to ASC/SE'7-05, compatible with all Siemens—Fire Safety 24VDC Section 13.2.2,when used with the PAD-4 battery alarm signaling devices. bracket(Model PAD4-BATT-BRKT). In cases where'Class A'circuits are used, an optional Model PAD-4-CLSA module can be added, providing Configuration Options two (2) additional 'Class A'outputs to each PAD-4 unit. Option I nput[s] Output Controls Circuit Types 1 Each NAC extender is also capable of operating other Input 1 All outputs Class B'circuits parts of a Siemens fire alarm system, such as door 2 Input 1 All outputs 'Class B'circuits holders, via 3 Amps @ 24VDC max of power-limited Input 2* Silences horns on Output 1 — auxiliary output. When the output activated,the 3 Input 1 Outputs 1 and 2 Class B'circuits total power available cannot exceed 6 Amps when Input 2 Outputs 3 and 4 Class B'circuits used with Models FP2011-U1 or 9 Amps when used 4 Input 1 Output 1 Class B'circuits with FP2012-U1. Input 2 Outputs 2,3 and 4 'Class B'circuits . Trouble conditions are monitored through each 5 Input 1 Outputs 1 through 4 Class A' g circuit pairs unit's two (2) inputs. In addition, one (1) 'Form C' 'Class A' Input 1 Outputs 1 through 4 circuit pairs Trouble contact is provided for monitoring each unit 6 that is connected through the input of a Siemens Input 2* Silences horns on Output 1 — FACP. Therefore,the user has the option of Input 1 Outputs 1 and 2 'Class A' connecting a PAD-4 NAC extender unit into a NAC of 7 circuit pairs InputOutputs 'Class A' a Siemens FACP, or the unit may be monitored with 2 3 and 4 P circuit pairs a Model TRI series monitoring module on a Siemens *denotes when used with Siemens Model'AS','NS'or'ZH'--series intelligent fire system. horn/strobe devices A separate'Form C' Trouble contact is used exclusively with each NAC extender to indicate AC Fail Trouble events on the NAC extender. s Industry, Inc. Building Technologies Division • _• Indicator Lights Temperature and Humidity Range AC Power ON: Each PAD-4 Distributed Power Supply Unit is®UL 864 AUX/PS: Yellow 9th Edition Listed for indoor dry locations within a Ground Fault: Yellow temperature range of 120+1-3°F (49+/-2°C)to Out.ut 1 Trouble: Yellow 32+/-3°F (0+/-2°C) and a relative humidity of 93+/-2% Outs ut 2 Trouble: Ye(, ata temperature of 90+/-3°F (32+/-2°C). Out.ut 3 Trouble: Yellow out•L1t 4 Trouble: Yellow Details for Ordering Test Mode: I Yellow Model Part Number Number D l -- .. PAD-4-ENCL 500-050081 PAD-unit enclosure PAD-4-MB 500-650217 PAD-unit main board Technical Data FP2011-U1 500-450222 170-Watt power supply FP2012-U1 S54400-Z60-A1 300-Wattowersu supply PP Y ' . .;" 7'17 2.OA @ 30VDC,max. m.: „r 4''� [resistive] System Kits— mow 4's" s7 7Y 2.OA @ 30VDC,max. �� r •: !a i�.��.aa x •a�. .� 1� �,� [resistive] 7. '5` � , Number. , Num'r•; ° c ;�C%�t .' �d., ,a �� �, 3.OA�er circuit,max._-- ,, .¢_ , ' ''.' t 4 - - 6A,max {via Model FP2o11 U1} Complete 6A PAD-4 kit with: + __-_--_—_- - '"" -One(1)Unit Enclosure,PAD-4-ENCL «f} 9A,max {via Model FP2012 U1} PAD4-6A S54339-A1-A1 s ,, , -One(1)Main Board,PAD-4-MB :u 32°-120°F -One(1)170W power supply,FP2011-U1 ',�, ,c. ! 1_^ i (0°-49°C) COmplete6APAD-4 kit with: V: .:-,`W'' Up to 93%@ 86°F(30°C); -One(1)Unit Enclosure,PAD-4-ENCL PAD4-6A-CLSA 554339-A2-A1 -One(1)Main Board,PAD-4-MB _ -� ,,- non-condensin• -One(1)170W power supply,FP2011-U1 ' One(1)circuit @ 3A max. -One(1)'Class A'Adapter Card,PAD-4-CLSA e 18AH Complete 9A PAD-4 kit with: PAD4-9A S54339-A3-A1'`'� " s -One(1)Unit Enclosure,PAD-4-ENCL f Two(2)'Class B'supervised -One(1)Main Board,PAD-4-MB t ; or -One(1)300W power supply,FP2012-U1 `^ ,v 4 -k'"'..'1.;i%•:'11 :, Two 2 'Class A'su.ervised Complete 9A PAD-4 kit with: , a ,.fi s' 7.OmA,max. -One(1)Unit Enclosure,PAD-4-ENCL G PAD4-9A-CLSA 554339-A4-A1 -One(1)Main Board,PAD-4-MB '._a' : s„ ; -;`. 16-33VDC/VFW -One(1)300W power supply,FP2012-U1 1' .s, .« ;:: rt Indoor,dry - One(1)'Class A'Adapter Card,PAD-4-CLSA ° - ct ria 0Supervised,power-limited — --- -- Optional Accessories '4',-,14..-...,-,-,,,,,,,,,;. :.,,....,,,,:.%,%.,, o 1.OmA standby - Ur — , s, current,max. — - fiber .Nub � i ' crri ' o Four(4)circuits o 2K ohms(+),8K ohms(-) PAD4-BATT-BRKT 554430-B4-A1 Battery bracket for NAC expander 24VDC @ 6 Amps PAD-4-LUA 554389-C1-A1 PAD-4 Laptop-Upload Adapter (with Model FPzo11-u1); PAD-4-CLSA 500-850254 'Class A'Adapter Card Total Outpt t Power • 24VDC @ 9 Amps S3AP 500-650257 PAD-4 NAC expander adapter plate (for use with PAD-3 and System 3 enclosures) (with Model FP2012-u1) o Two(2)'Class A'; -Up to four(4)'Class A' Output Circuits/ __'iia Model PAD-4 CLSA] Configurations: o Four(4)'Class B'; o One(1)Class A, Two 2 Class B; Single-Unit Dimensions: W•x-H x-D 13.5"-x-18.75"-x-3.25" Model PAD-4-ENCL (34 3 cm -x-47.6 cm.-x-8.3 cm.) Color: Red Model,PAD-4-ENCL s Industry, Inc. Building Technologies Division • • • Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road s Industry, Inc. Florham Park,NJ 07932 East Oakville,Ontario February 2014 Building Technologies Division Tel:(973)593-2600 (SII-F5) L6H OH6/Canada Supersedes sheet dated 10/13 FAX:(908)547-6877 Printed in U.S.A. Tel:[905]465-8000 (Rev.3) URL:www.usa.Siemens com/Flre URL:www.Siemens.CA PS-1280 12Von 8.0AH Rechargeable Sealed Lead Acid Battery We've Got The Power.'" Features • Absorbent Glass Mat(AGM)technology for superior performance • Valve regulated,spill proof construction allows safe operation in any position • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover(UL94-HB) • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 20845 Terminals (mm) Performance Specifications • Fl-Quick disconnect Nominal Voltage 12 volts(6 cells) tabs,0.187"x 0.032"- Mate with AMP.INC. Fl F2 Nominal Capacity FASTON"187"series F32l I-3.4-I 20-hr. (400mA to 10.50 volts) 8.00 AH -OR- MI I415 Mal 16.35 • F2 Quick disconnect 10-hr. (720mA to 10.50 volts) 7.20 AH tabs,0.250"x 0.032" ®=o.e ®208 5-hr. (1.33A to 10.20 volts) 6.65AH -Mate with AMP.INC 1-hr. (4.90A to 9.00 volts) 4.90 AH FASTON"250"series 15-min.(15.1A to 9.00 volts) 3.78 AH Physical Dimensions: in(mm) Approximate weight 5.51 lbs.(2.5 kg) Energy Density(20-hr.rate) 1.69 W-h/in3(103.39 W-h/I) ISpecific Energy(20-hr.rate) 17.42 W-h/Ib(38.41 W-h/kg) 0 w internal Resistance(approx.) 18 milliohms ® I Max Discharge Current(7 Min.) 24.0 amperes Max Short-Duration Discharge Current(10 Sec.) 80.0 amperes r Shelf Life(%of nominal capacity at 68°F(20°C)) ". _s /O 1 Month 97% " ow I_ HT H 3 Months 91% MODEL PS-1280 Fl 6Nw��°" �^M. � � 6 Months 83% Operating Temperature Range I" L I Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) L 5.95(151) W:2.56(65) H:3.72(94.5) HT 3.94(100) Case ABS Plastic Tolerances are+/-0.04 in.(+/-1mm)and+1-0.08 in.(+1-2mm)for Power-Sonic Chargers PSC-12800A,12800A-C height dimensions.All data subject to change without notice. 1 c urr sa i 1 t r. ti n hauv°rrrnr I;.iha lutea •dibon of our�<_finical M s rssh a,pit li,lrd,...... s. t www.power-sonic.com 1 p ,,wER�,,,;//iSON/l PS-1280 12 Volt 8.0 AH Discharge Characteristics Charging Characteristics(Cycle Use) 6V Battery 12V Battery - M M Charge Charging Charged To .:alum:25T Volume Current Voltage 6.5- 13.0 % (A) ht/cell) 0.10CA-2.25 V/Cell Temperature:25'C 6.02 - 12.0 --� `�4` 120- 0.25- a) 15- Charged Volume CM _ 0.20_ _ 5.5- 11.0 , t00- 14 - --- - Charge Voltage, 400A • 5.0- 10.0 .-/c.�1.88A.74�• 80- 0.15- 13 r r Constant 2.25 V/Cei1 6 I I I •C 45- 9.0 ' 8A SA 0.10- �'r / ---Alter 50%Discharge 12 t I I y f 40- -After 100%Discharge ~ 4.0- 8.0 -J-� 0.05- 11- I I 24A 16A 20 Charging CurrentI I t I 1 2 4 8 8 10 20 40 80 2 4 8 8 10 20 - 0- -0 4 8 12 16 20 24 28 32 36 40 I min h l Discharge Time Charging Time(Hours) Temperature Effects in Relation to Battery Capacity Cycle Life in Relation to Depth of Discharge 120 Testing rwndibon 0.05CA Diachsrging:rwrrent 0.17C(FV 1.7V/cel); 3e 100 - 0.10 CA Charging:artent 2.45V/cegmax.0.25CA; 0.20CA Charging volume:125%of discharged capacity. 9 80 120 1111111•111M111111111111111111111111.1 m ----■ 0 60 . ICA 2CA 100 ��- 40 -.' 3CA 60 \�� _ ■ • 0 20 v 60 _`,--``. 0 0 -100% SUN. -- 30%O ■ -20 -10 0 10 20e( 30 40 50 ro 40 DOD DODDOD Temperature(°C) 20 --- Ambient Temperature: ■ Self Discharge Characteristics 0 200 400 600 800 1000 1200 Number of Cycles a 100 `--_ l ii 80 m 60 •"`- ao ����ea� Charging E 20 •--•-- 0 ..----- Cycle Applications:Limit initial current to 2.4A.Charge until battery voltage 0 2 4 6 8 10 12 (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 volts until current drops to under 80mA.Battery is fully charged under these Storage Time(Months) conditions,and charger should be disconnected or switched to"float"voltage. gmlik No supplementary charge required (Carry out supplementary charge before use 6100%capacity is required.) "Float"or"Stand-By"Service:Hold battery across constant voltage source of 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its Supplementary charge required before use.Optional charging way as below own current level and maintain itself in a fully charged condition. Ili1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8-10hours at limted current 0.05CA. Note:Due to the self-discharge characteristics of this type of battery,it is imperative that they be charged within 6 months of storage,otherwise permanent Mk Supplementary charge may often fail to recover the capacity. loss of capacity might occur as a result of sulfation. The battery should never be left standing till this is reached Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for°CSeries downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@powersonic.com customer-service@pawer-sonic.com support@power-sonic.com intemational-sales@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way• San Diego,CA 92154• USA•Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0211 1 M 0 2012 Power-Sonic CorporationAll rights reservedal trademarks are the property of their respective owners. • SIEMENS Data Sheet Fire Safety&Security Products '08 Series Notification Appliances ZH & ZR — Strobes, Horns, & Horn / Strobes Application: Indoor .0s FIRE Model Model (ZR&ZH 'ZH'Series 'ZR' Series Mounting) Product Overview — Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, XLS panel,or PAD-3 power supply with built-in sync protocol — Selectable Continuous Horn or Temporal (Code-3)Tones with 90 or 95 dBA selectable setting (ZH) — Ceiling-mount models feature field-selectable Candela settings of 15/30/75195cd and 115/177cd — Wall-mount models feature field-selectable Candela settings of 15/30/75/110cd and 1351185cd — Base plate is protected by a disposable cover,and the appliances can quickly snap onto the base after the walls are painted — Strobes produce 1 flash per second — "Special Applications"listed with Siemens panels — EZ Mount Universal Mounting Plate(Model ZB Series)—uses single plate for ceiling and wall mount installations — EZ Mount design—with separate base plate—provides ability to pre-wire the base and test the circuit wiring before the walls are covered — ®UL Listed &®ULC Listed; FM,CSFM &NYC Fire Department Approved — ADA/NFPA compliant Specifications • General — Audible/Visual notification appliances shall be listed for indoor use only — Appliances shall be listed under®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired)and®UL Standard 464(Fire Protective Signaling) — Appliances shall use a universal back plate,which shall allow mounting to a single-gang,double-gang,4-inch-square,4"-octal,or a 3-1/2"-octal backbox — Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate — Continuity check shall occur for entire NAC circuit prior to attaching any audible/visual-notification appliances — Dust cover shall fit and protect the mounting plate — Dust cover shall be easily removed when the appliance is installed over the back plate — Removal of an appliance shall result in a trouble condition by the Siemens Fire Alarm Control Panel (FACP) '08 Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) _ • Strobes — Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second)over the Regulated Input Voltage Range,and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens — Strobes shall be available with two or four field-selectable settings in one unit,and shall be rated—per®UL 1971 —for up to: • 15/30/75/110cd for wall mounted • 1351185cd for wall mounted • 15/30/75195cd for ceiling mounted • 115/177cd for ceiling mounted — Strobes shall operate over an extended temperature range of 32°F to 120°F(0°C to 49°C),and be listed for maximum humidity of 95%RH — Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Siemens FACP • Audible and Audible/Strobe Combinations — Horns and horn/strobes shall be listed for Indoor use under®UL Standard 464 — Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output — Horns shall have at least 2 sound-level settings of 90 and 95 dBA • Synchronization Modules — The strobe portion,when synchronization is required,shall be compatible with _ DSC sync modules, FS-250 panel,XLS panel,or PAD-3 power supply with built-in sync protocol — The strobes shall not drift out of synchronization at any time during operation — Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability - to silence the audible, if required — Strobes shall revert to a non-synchronized flash-rate,if the sync module or Power Supply should fail to operate(i.e.—contacts remain closed) — All notification appliances shall be listed for Special Applications: ■ Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" ➢ Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second,and ADA Guidelines specify a flash rate of 1-to-3 flashes per second • All candela ratings represent minimum-effective Strobe intensity, based on®UL Standard 1971 ■ Series ZH Strobe products are listed under®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%) ■ Series ZH horns are listed under®UL Standard 464 for audible signal appliances(Indoor use only) SIEMENS Industry, Inc. Building Technologies Division r . Mounting Diagram 1,- 4.85 1.86 4.8li • 2>N 1 4•85 294-1 I i i1 • • 1 1 Mk • I r r , 111 •L____ • ✓ L _ ✓ L - (Shown In Inches) Mounting Options ® / § F'401 11:i-4 —•- •-' - SEGUEING ai SIDE OPENING FOR PLAT ScaEWOnMR \ Figure 3:Installment Fiore d:hero al(See stet S Wow* 1. Instal mounting plate as shown in figure 1 to a singlegang. 6. Important Device only has one mounting orientation.Match the double-gang.4'square.4'octagon,or a 3'J,'octagon badibox top of the base to the top of the device. with the provided pan head screws. To remove dust cover. 7. If it is desired to further secure the device to the base.then two place thumb and index finger on too edoes of cover and pull off optional screws are provided.To install these saws punch out cover. the screw holes located at the top and bottom of the device. 2. Connect field wiring per figures 2 and 3. 8. To remove the apprance,push a smal flat-bladed screwdriver 3. Address wires back into backbox. into the side opening. The screwdriver must clear the snoop mounting4. Place dust cover over mounting plate to protect the terminals release opening by Wto disengage the snap. Do not pry off Mile performing wiring continuity check.. housing with the screw driver.Apply pressure with screw driver, 5. Remove dust cover before snapping or installing the appliance Inserted in either side opening.as shown in Fig 4 to release the onto the mounting plate per fig 3. housing. Technical Data DI and ZH#IC Horn Reverkerent MA Per UL464 ZH Horn Current Drew[ZH-MC and ZH at 24V] (Am _'s) Setting 16-33 Volts 16.OV 24V 33.0V DC Hilt' 0.044 Continuous High 83 87 90 _ Low - 0.018 - Horn Low _ 77 81 83 FWR High' 0.075 Code 3 Horn or High _ 79 82 86 Love e March Tm'ie' Low 72 76 79 *Current ode 3 Horn and`d Tine elling'. - 'Available in sync mode only SIEMENS Industry, Inc. Building Technologies Division w V Technical Data - (continued) ®UL Listed Models and Ratings Operating Range Voltage [ strobe( c ) ® F Mounting®UL19711 S526 02] Models* (VDCNRMS) (VDCNRMS) (c� ZR-MC 16.0-33.0 20.0-31.0 - WaN 15130/75/110 ZR-HMC 16.0-33.0 20.0-31.0 - WaN 135/185 ZR-MC-C _ 16.0-33.0 20.0-31.0 - Ceiling 15/30175/95 ZR-HMC-C 16.0-33.0 20.0-31.0 - Ceiling 115/177 ZH-MC 16.0-33.0 20.0-31.0 X Wal 15/30/75/110 ZH-HMC 16.0-33.0 20.0-31.0 X Wal 135/185 ZH-MC-C 16.0-33.0 20.0-31.0 X Ceding 15130175/95 ZH-HMC-C 16.0-33.0 _ 20.0-31.0 X Ceiling 115/177 ZH 16.0-33.0 20.0-31.0 X Wail or Ceiing - - *Maiabk in red and while ®UL Current Ratings (ZR Strobe Only) Maximum RMS Current(AMPS) MC HMC MC-C HMC-C 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd DC 16-33VDC 0.064 0.098 0.175 0.233 0.318 0.445 0.069 0.111 0.200 0.264 0.318 0.445 FWR-16-33VRMS 0.108 0.164 0.268 0.368 0.482 0.684 0.117 0.180 0.297 0.398 0.482 0.684 ®UL Current Ratings ZH Horn/Strobe Maximum RMS Current(AMPS) Horn MC HMC MC-C HMC-C Setting 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 1-Iigh' 0.078 0-113 0.195 0259 0.371 0.506 0.087 0-131 0.222 0.292 0.371 0.506 DC 16-33VDC Law• 0.070 0.107 0.188 0.246 0.324 0.455 0.075 0.121 0.213 0.277 0.324 0.455 FWR 16-33VRMS Hi 0.141 0.200 0.302 0.406 0.521 0.722_0.149 0.216 0.331 0.436 0.521 0.722 Low 0-123 0.179 0.290 0.391 0.497 0.699 0-131 0.195 0.319 a421_0.497 0.699 •Ctrrent Draw is the same for the Continuous Hon; Code 3 Horn and March Time Settings Details for Ordering - (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Description Mounting UL ULC FM CSFM Number Number Options* ZH-R 500-636159 Z Horn: Red B,D,E,F X X X X ZH-W 500-636160 Z Horn: White B,D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela(Wall),Red B,D,E,F X X X X ZH-MC-W 500-636162 Z Horn: Multi Candela(Wall),White B,D,E,F X X X X ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela(Wall),Red B,D,E,F X X X X ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela(Wall),White B,D,E,F X X X X ZH-MC-CR 500-636165 Z Horn: Multi Candela(Ceiling),Red B,D,E,F X X X X ZH-MC-CW 500-636166 Z Horn: Multi Candela(Ceiling),White B,D,E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela(Ceiling),Red B,D,E,F X X X X ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela(Ceiling),White B,D,E,F X X X X ZR-MC-R 500-636169 Z Strobe:Multi Candela(Wall),Red B,D,E,F X X X X ZR-MC-W 500-636170 Z Strobe:Multi Candela(Wall),White B,D,E,F X X X X ZR-HMC-R 500-636171 Z Strobe:Hi Multi-Candela(Wall),Red B,D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe:Hi Multi-Candela(Wall),White B,D,E,F X X X X ZR-MC-CR 500-636173 Z Strobe:Multi Candela(Ceiling),Red B,D,E,F X X X X ZR-MC-CW 500-63 61 74 Z Strobe:Multi Candela(Ceiling),White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe:Hi Multi Candela(Ceiling),Red B,D,E,F X X X X ZR-HMC-CW 500-636176 Z Strobe:Hi Multi Candela(Ceiling),White B,D,E,F X X X X ZB-R 500-636193 Accessory-(Includes base,dust cover,mounting screws and installation sheet) ZB-W 500-636194 Accessory-(Includes base,dust cover,mounting screws and installation sheet) X =Listed 1 Approved *=Refer to data sheet#:2585 for detailed mounting options Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario June 2012 Building Technologies Division Tel:(973)593-2600 (sip L6T 5E4/Canada SupersedesJun nee dated 3i10 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.3) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858 appliances are specified, the strobe intensity shall have that shall allow mounting to a single-gang, double-gang, field selectable settings and shall be rated per UL Stan- 4-inch square, 100mm European type backboxes, or the - dard 1971 at 15/30/75/110 or 135/185 candela for wall SHBBS Surface Backbox. mount and 15/30/75/95 or 115/177 candela for ceiling All notification appliances shall be listed for Special Ap- mount. The selector switch for selecting the candela plications. - shall be tamper resistant. When synchronization is required,the appliance shall • Strobes are designed to flash at 1 flash per second be synchronized using the Siemens DSC sync modules, minimum over their"Regulated Input Voltage Range". FS-250 panel,XLS panel, or PAD-3 power supply with Note that NFPA-72 specifies a flash rate of 1 to 2 built-in sync protocol. The strobes shall not drift out of flashes per second and ADA Guidelines specify a flash r synchronization at any time during operation. If the sync rate of 1 to 3 flashes per second. module or Power Supply fails to operate, (i.e., contacts • All candela ratings represent minimum effective Strobe remain closed), the strobe shall revert to a non-synchro- intensity based on UL Standard 1971. nized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while main- taining strobe activation when used with Siemens syn- chronization. For complete technical information, please consult the The Series AS Audible Strobe and Series AH Audible relevant installation sheets as well as the Siemens shall incorporate a Patented Universal Mounting Plate Compatibility Guide. Ordering Information / Mounting Requirements /Approvals Model Wall Ceiling Agency Approvals Number Order Code Mount Mount Mounting Options** UL ULC CSFM FM AS-MC-R 500-636010 X - A,B,D,E,F,G,J,N,R,X X # # 4 AS-MC-W 500-636011 X - A,B,D,E,F,G,J,N,R,X X # # # - AS-HMC-R 500-636012 X - A,B,D,E,F,G,J,N,R,X X # # # AS-HMC-W 500-636013 X - A,B,D,E,F,G,J,N,R,X X # # # AS-MC-CR 500-636006 - X A,B,D,E,F,G,J,N,R,X X # # # AS-MC-CW 500-636007 - X A,B,D,E,F,G,J,N,R,X X # # # AS-HMC-CR 500-636008 - X A,B,D,E,F,G,J,N,R,X X # # # AS-HMC-CW 500-636009 - X A,B,D,E,F,G,J,N,R,X X # # # 1 AS-75-R-WP 500-636016 X - I X # # 4 AS-75-CR-WP 500-636015 - X I X # 4 # AH-R 500-636003 X X A,B,D,E,F,G,J,N,R,X X # # # AH-W 500-636004 X X A,B,D,E,F,G,J,N,R,X X # # # AH-R-WP 500-636005 X X K X # # # X=listed/approved #=pending *=Refer to Data Sheet#2585 for mounting options. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE - USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park,NJ 07932 7/07 Brampton,Ontario Siemens Building Technologies Tel:(973)593-2600 SM Canada L6T 5E4 FAX:(973)593-6670 SFS-IG Tel:(905)799-9937 July 2007 Fire Safety Website:www.sbt.siemens.com/fis Printed in U.S.A. FAX:(905)799-9858 Now Issue SIEMENS Fire Safety AS/AH AS Audible Strobe Appliances and AH Audibles ENGINEER AND ARCHITECT SPECIFICATIONS • UL listed. ULC,CSFM,and FM pending. • ADA/NFPA/UFC/ANSI Compliant .; • Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 135/185cd(Multi-Candela models) • Ceiling mount models are available with field selectable candela settings of 15130/75195cd or 115/177cd(Multi- candela ceiling models) AS-MC-CW AS-MC-R • Selectable Continuous Horn or Temporal(Code 3). • 3 Selectable dBA settings(99,95 and 90 dBA)in both tones • Weatherproof models are available for outdoor use • Strobes can be synchronized using the Siemens DSC sync modules,FS-250 panel,XLS panel,or PAD-3 power supply with built-in sync protocol. • Fast installation with IN/OUT screw terminals using#12 to#18 A AWG wires H-W AH-R Description The Siemens 2-wire Series AS Audible Strobe Appli- 2 or more visual appliances within the field of view all of ances and Series AH Audibles offer more features with this plus the ability to silence the audible is achieved by low current draw. using only 2 wires. Strobe options for wall mount models include the Sie- mens MC multi-candela wall strobes with field selectable Engineering Specifications candela settings of 15/30/75/110cd, or the high intensity HMC strobe with field selectable 135/185cd. The notification appliances shall be Siemens Series Ceilingmount models incorporate Siemens MC multi- AS Audible Strobe appliances and Series AH Audible p appliances or approved equals. The Series AS Audible candela ceiling strobe with field selectable settings of be listed for UL Standard 1971 (Emergency Devices for 15/30/75/95cd or the high intensity HMC strobe with field the Hearing-Impaired)for Indoor Fire Protection Service. selectable settings of 115/177cd. The Series AH Audible shall be UL Listed under Stan- _ The audible provides a selectable choice of either a con- dard 464(Fire Protective Signaling). Both shall meet tinuous horn or temporal pattern (Code 3)when constant the requirements of FCC Part 15 Class B. All inputs voltage from a Fire Alarm Panel (FACP) is applied. Each shall be compatible with standard reverse polarity su- tone has 3 dBA settings from which to choose. pervision of circuit wiring by a Fire Alarm Control Panel When used with the Siemens DSC sync modules, (FACP). FS-250 panel, XLS panel, or PAD-3 power supply with The audible portion of the appliance shall have a mini- built-in sync protocol, synchronization of the continuous mum of three(3)field selectable settings for dBA levels horn tone provides the temporal (code 3)tone(man- and shall have a choice of continuous or temporal (Code dated by NFPA 72)simultaneously for all audible appli- 3)audible outputs. ances. This ensures a distinct temporal (code 3) pattern The strobe portion of the appliance shall produce a flash when 2 or more audibles are within hearing distance. If rate of one(1)flash per second over the Regulated not synchronized the temporal sound could overlap and Voltage Range and shall incorporate a Xenon flashtube not be distinctive. At the same time the strobes will be enclosed in a rugged Lexan®lens. The Series AS synchronized. This provides the ability to comply with shall be of low current design. Where Multi-Candela ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing CATALOG SHEET 2578 • SIEMENS INSTALLATION INSTRUCTIONS AUDIBLE STROBE WEATHERPROOF APPLIANCE fWALL/CEILING MOUNT VERSIONI IMPORTANT—All audible and visual signaling appliances must be The AS-WP appliance can be field set to provide high (HI) dBA, installed in accordance with all applicable national and local fire alarm medium(MED)dBA or low(LO)dBA sound output. codes and any other required regulatory agencies. The strobe is designed for use with either filtered DC (VDC) or Series AS-WP appliance is the industry's first 2-wire horn strobe alarm unfiltered full-wave-rectified (FWR) input voltage. All inputs are appliance that provides a selectable continuous or Code 3 horn tone polarized for compatibility with standard reverse polarity supervision of and continuous strobe when connected directly to the Fire Alarm circuit wiring by a FACP. Control Panel (FACP), or provides a synchronized Code 3 horn tone (or March Time) and synchronized strobe when connected to a NOTE: The Code 3 temporal pattern(1/2 second on, 1/2 second off, notification appliance circuit running the Siemens sync protocol. 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat)is Additionally,Siemens Multi-High-Candela(AS-HMC-WP and AS-HMC- specified by ANSI and NFPA 72 for standard emergency evacuation C-WP)appliances provide two selectable settings(135/185 or 115/177, signaling. The Code 3 Horn should be used only for fire respectively). The AS-WP appliance is UL Listed for indoor/outdoor evacuation signaling and not for any other purpose. use under Standard 1638 for Emergency Devices for the Hearing Impaired (Visual Signal Appliances), UL464 for Audible Signal NFPA 72/ANSI 117.1 conform to ADAAG Equivalent Facilitation Appliances and UL Standard 1971 for Emergency Appliances for the Guidelines in using fewer, higher intensity strobes within the same Hearing Impaired. For outdoor application the AS-WP must be protected area. mounted to the Weatherproof Backbox(WPBBS). The AS-WP uses a xenon flashtube with solid state circuitry enclosed in a polycarbonate NOTE: Refer to P/N 315-096363 for the maximum number of lens to provide maximum visibility and reliability for effective visible appliances on a single notification appliance circuit. signaling. CAUTION: NOT RECOMMENDED FOR USE AT REFRIGERATOR I FREEZER DOOR ENTRANCES OR OTHER AREAS WITH PERSISTENT it CONDENSATION. SPECIFICATIONS: Table 1:Models and Ratings Operating Voltage UL Rated Strobe Maximum RMS Current Maximum RMS Current Maximum RMS Current Model** (Special Application) Candela(cd) w/Hi dBA(Amps) w/Med dBA(Amps) w/Low dBA(Amps) • Per UL1638,UL1971 and UL464 At-40°C At 25°C DC FWR DC FWR DC FWR (VDCNRMS) (UL1638) (UL1971) AS-75-R-WP 16.0-33.0 115 30/180* 0.178 0.249 0.164 0.239 0.159 0.233 AS-75-CR-WP 16.0-33.0 115 30/180" 0.178 0.249 0.164 0.239 0.159 0.233 AS-HMC-C-WP* 16.0-33.0 50/75 115/177 0.376/0.509 0.546/0.742 0.360/0.493 0.509/0.716 0.355/0.498 0.488/0.705 AS-HMC-WP* 16.0-33.0 65/90 135/185 0.376/0.509 0.546/0.742 0.360/0.493 0.509/0.716 0.355/0_.498 0.488/0.705 *180cd is on Axis only. - **Available in red and white. Table 2: ASWP-dBA Sound Output Description Volume Reverberant Per UL 464 Anechoic dBA at 10 Feet 16.0VDC 24.0VDC 33.0VDC 20.0VDC 24.0VDC 31.0VDC Low 80 83 86 88 90 91 Continuous Horn Medium 85 88 91 93 95 97 High 88 91 93 97 99 100 Low 75 79 _ 82 88 90 91 Code 3 Horn Medium 80 84 86 93 95 97 (or March Time)*** High 84 87 90 97 99 100 ***Available in sync mode only. _ NOTES: - 1. Strobe will produce 1 flash per second over the Input Voltage range. 2. These models meet the required light distribution patterns defined in UL 1638,UL 464 and UL 1971. 3. All models are UL Listed for indoor and outdoor use with a temperature range of-40°F to 150°F(-40°C to+66°C)and maximum humidity of 98%± 2%RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and is not subjected to misuse or abuse. When calculating the total current: Use Table 1 to determine the highest value of"RMS Current"for an individual AS-WP Appliance then multiply the value by the total number of AS-WP Appliances. Be sure to add the currents for any other appliances powered by the same source and include any required safety factors. These appliances are not designed to be used on coded systems in which the applied voltage is cycled on and off. Siemens Building Technologies,Inc. P84820-001 B 8 Femwood Road Sheet 1 of 3 Florham Park,New Jersey 07932 THESE APPLIANCES WERE TESTED TO THE VOLTAGE LIMITS OF 16.0-33.0 VOLTS FOR 24V MODELS USING FILTERED DC OR UNFILTERED . FULL-WAVE-RECTIFIED VOLTAGE. DO NOT APPLY VOLTAGE OUTSIDE OF THIS RANGE. Note:Refer to the installation instructions for the appropriate NAC to find the maximum allowed voltage drop. Use this value along with the current draw for the appliance to determine the allowable wire resistance. The maximum wire resistance between strobes shall not exceed 35 ohms. CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT. Note: These notification appliances are UL Listed as "Special Application". They are intended to be used only with Siemens notification appliance circuits. WARNING: MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE SYSTEM'S PRIMARY AND SECONDARY POWER SOURCES DO NOT EXCEED THE POWER SOURCES' RATED CAPACITY OR THE CURRENT RATINGS OF ANY FUSES ON THE CIRCUITS TO WHICH THESE APPLIANCES ARE WIRED. OVERLOADING POWER SOURCES OR EXCEEDING FUSE RATINGS COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CANDELA AND SOUND OUTPUT(SPL)SETTINGS: To set the candela,slide the switch to the desired setting. The setting in indicated by the pointer and label visible on the bottom of the lens. Figure 2:Showing Location of Figure 1: Jumper Plug 0 CODE b O POINTERr, CANDELA 36 _.5 SLIDE r-\_ SWITCH OD CANDELA POINTER BOTTOM VIEW BOTTOM VIEW HI ci v 0 ME LO Factory setting is on medium dB and Code 3(or March Time).AS-HMC comes preset at 185cd. AS-HMC-C comes preset at 177cd. 0 WARNING: THE CANDELA SELECT SWITCH MUST BE FIELD SET TO THE REQUIRED CANDELA INTENSITY BEFORE INSTALLATION. _ WHEN CHANGING THE SETTING OF THE CANDELA SELECT SWITCH,MAKE CERTAIN THAT IT"CLICKS"IN PLACE. AFTER CHANGING THE CANDELA SETTING,THE APPLIANCE MUST BE RETESTED TO VERIFY PROPER OPERATION. Figure 3: Jumper plug settings for High,Medium,Low and Figure 4: Jumper plug setting for Continuous Horn Code 3(or March Time). a SHOWN SET ON HIGH dB j —— TURN PLUG 90' MED SHOWN SET ON MED d6 LOW 12 SHOWN SET ON LOW dB CODE 3 (Use needle nose pliers to pull and properly set the jumper plugs) No jumper plug is needed for continuous horn setting. However, it is recommended that the jumper plug be retained in the unit for future use(if needed)as shown in Figure 4. NOTE: The AS-WP must be set for Code 3(or March Time)when used on synchronized notification appliance circuit(NAC). WIRING AND MOUNTING INFORMATION: CAUTION: The following figure shows the maximum number of field wires(conductors)that can enter the backbox used with each mounting option. If these limits are exceeded,there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damage - the product. Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit,especially if sheathed multiconductor cable is used. Figure 5: Figure 6: • The AS-WP Appliance has in-out wiring terminals • • that accepts two#12 to#18 American Wire Gauge FROM PRECEDING APPLIANCE OR FIRE • -•TO NEM APPLIANCE OR (AWG)wires at each screw terminal. Strip leads ALARM CONTROL - - END OF LINE 3/8"inches for connection to screw terminals. PANEL(FACP) RESISTOR(EOLR) • Break all In-out wire runs on supervised circuit 9 (-) supervision as shown in Figure 6. The polarity III• I shown in the wiring diagrams is for the operation of the appliances. The polarity is reversed by the FACP during supervision. IF THE AS-WP HOUSING DOES NOT PROPERLY CONTACT THE GASKET ON THE WPBBS BACKBOX,MOISTURE MAY SEEP INTO THE AS- WP WHEN USED IN A OUTDOOR APPLICATION AND THIS COULD RESULT IN IMPROPER OPERATION OF THE PRODUCT. Siemens Building Technologies,Inc. P84820-001 B Sheet 2 of 3 • . SURFACE(INDOOR/OUTDOOR). WPBBS #6-20 BACKBOX SCREW ‘00D SCREWS MAXIMUM NUMBER OF CONDUCTORS AWG#18 AWG#16 AWG#14 AWG#12 4 4 4 4 THIS UNIT MUST BE MOUNTED ON A FLAT SURFACE,SO THAT THE SURFACE COVERS THE ENTIRE BACK SURFACE OF THE BACKBOX. WHEN USED IN AN OUTDOOR APPLICATION OR A NEMA 3R APPLICATION, USE WEATHER PROOF RATED CONDUIT FITTING ON ALL KNOCKOUTS OF THE BACKBOX. 1. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product. The knock-out opening on the backbox is sized for a '/2"conduit and matching connector. Be sure that a proper watertight conduit fitting is used to connect the backbox for outdoor/severe environment applications. Do not pass additional wires(used for other than the signaling appliance)through the backbox. Such additional wires could result in insufficient wiring space for the signaling appliance. 2. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the signaling appliance. 3. Connect 4 field wires to the AS-WP terminal block(polarity must be observed). 4. Bend the 4 field wires up 90°at the connection to the terminal block and carefully push the 4 field wires into the backbox by hand. 5. Carefully press the AS-WP to the backbox, verifying that the AS-WP is in contact with the gasket all the way around. It should not be resting on the lip of the backbox. 6. Screw the AS-WP to the WPBBS using the#6-20 screw. WARNING: A SMALL POSSIBILITY EXISTS THAT THE USE OF MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW, UNDER CERTAIN CIRCUMSTANCES,MIGHT INDUCE A PHOTO-SENSITIVE RESPONSE IN PERSONS WITH EPILEPSY. STROBE REFLECTIONS IN A GLASS OR MIRRORED SURFACE MIGHT ALSO INDUCE SUCH A RESPONSE. TO MINIMIZE THIS POSSIBLE HAZARD,SIEMENS STRONGLY RECOMMENDS THAT THE STROBES INSTALLED SHOULD NOT PRESENT A COMPOSITE FLASH RATE IN THE FIELD OF VIEW, WHICH . EXCEEDS FIVE(5)Hz AT THE OPERATING VOLTAGE OF THE STROBES.SIEMENS ALSO STRONGLY RECOMMENDS THAT THE INTENSITY AND COMPOSITE FLASH RATE OF INSTALLED STROBES COMPLY WITH LEVELS ESTABLISHED BY APPLICABLE LAWS, STANDARDS, REGULATIONS,CODES AND GUIDELINES. 0 WARNING: REMOVAL OF THE PRINTED CIRCUIT BOARD COVER AT THE BACK OF THE MOUNTING PLATE COULD RESULT IN SEVERE ELECTRIC SHOCK. The 135/185cd and 177cd settings are listed for use in sleeping or non-sleeping areas when installed in accordance with appropriate NFPA Standards and the AHJ. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital appliance,pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver, 3)Connect the equipment into an outlet on a circuit different from that to which the receiver is connected,and 4)Consult the dealer or an experienced radio/TV technician for help. Siemens Building Technologies,Inc. P84820-001 B Sheet 3 of 3 SIEMENS Catalog Sheet Fire Safety& Security Products '08 Series Notification Appliances ST — Strobes and Strobe Plates Application: Indoor .6. • nbtile;11iRE- F., L. ST-MC-RETRO-R ST-MC-CW/ST-HMC-CW Plate Strobe Product Overview — Strobes feature low current draw — Ceiling-mount, multi-Candela models are available with field-selectable Candela settings of 15130175195cd or 115/177cd — Wall-mount, multi-Candela models are available with field-selectable Candela settings of 15/30/75/110cd — Strobes produce one (1)flash per second over the regulated voltage range — Synchronized using the Siemens DSC sync modules, FS-250 panel,XLS panel, or PAD-3 power supply with built-in sync protocol — Fast installation with In 1 Out screw terminals using #12 to#18 AWG wire — ®UL Listed &®ULC Listed; FM,CSFM & NYMEA Approved — Meets OSHA 29 Part 1910.165 Specifications — Visual-notification appliances shall be Siemens Series ST Strobe Appliances or approved equals — The Series ST shall meet and be listed for®UL Standard 1971 for Indoor Fire Protection Service (Emergency Devices for the Hearing-Impaired) — Strobes shall be listed for indoor use only — Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens — All inputs shall be compatible with standard, reverse polarity supervision of circuit wiring by a Fire-Alarm Control Panel (FACP) — Strobe Plates, when installed, shall be the Siemens-Series Strobe Plate (ST-MC-RETRO), and shall have the same electronic circuitry as the Siemens Series ST — The Series ST Strobe shall be of low current design '08 Series Notification Appliances 2573 SIEMENS Industry, Inc. Building Technologies Division • Specifications - (continued) — The strobe intensity for ceiling-mount models shall have field-selectable settings, and shall be rated per®UL Standard 1971 for 15130175195cd or 1151177cd where multi-Candela appliances are specified — The strobe intensity for wall-mount models shall have field-selectable settings, and shall be rated per®UL Standard 1971 for 15130/75/110cd where multi-Candela appliances are specified — The selector switch for selecting the candela shall be tamper resistant — The appliance shall be compatible with the Siemens DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol when synchronization is required — The strobes shall not drift out of synchronization at any time during operation — If the sync module or Power Supply fails to operate, (i.e. -contacts remain closed), the strobe shall revert to a non-synchronized flash rate — The strobes shall be designed for indoor surface of flush mounting — The Series ST Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 100mm European type back boxes, or the SHBBS Surface Back box — The Series ST multi-Candela or single-Candela Strobe Plate shall mount to either a standard, 4-inch square back box for flush mounting, or shall mount to the Siemens SBL2S back box for surface mounting — All notification appliances shall be backward compatible General Notes — Strobes are designed to flash at one(1)flash per second minimum over their"Regulated Voltage Range" * — All candela ratings represent minimum effective Strobe intensity based on®UL Standard 1971 — All notification appliances shall be listed for"Special Applications" * NFPA-72 specifies a flash rate of 1 to 2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second Mounting Diagram 41--588 (Shown In Inches) 2.581 2.70 To • 7365e �- 10.70 _. 11I FIRE It [ i ,,,,,MIV FIRE Mounting Options - B F WS11 lC 1P411NG D FLUSH OR sum=mom. F FWITH OR SURFACE►BUNT X SURFACE Lamm --am SINGLEGIV4 4130 X 1-1Q'033t$4Qa•Oc BACKDOX 2'OEEP oR maim 37.11A41 X 2-14' ILRariANsCKIM CESDACmaf _=SURFACEQ i 37Ra3E ( S) SCRBVSfr , LIOLFRIRO }(1;;;- 9ClEYs wA th r �4 �� STROE • /I ` ;- a ell A 'i .I..� '�PLATE t NG.cam R LM�+ COMER PI1 coa _„•1_,,,-----.. AOJNrm 11 /iA ' I1.1AIOA4 MAIER OF CONDUCTORS MOM/NUMBER of CONDUCTORS IAAxAlA NUMBER OF OO CUCTORS —, oa+ER MGM. MG 016 NIG*14 AYYGt12 MG AIT AWG1016 AWG*14 AMGA12 NAG EIS DWGAlI6 JAVGA14 MG*12 4 4 4 4 4 4 4 4 4 4 4 4 SIEMENS Industry, Inc. Building Technologies Division Technical Data ®UL and®ULC Listed Ratings Operating Voltage Voltage Range Strobe Model (Special APPlt on) Per •U C 5526-02] candela [Per®UL1971] ( (VI�CNRMS) (cd)(VDCNRMS) ST-MC-RETRO-R 16.0-33.0 20.0-31.0 15130175/110 Current Ratings Maximum RMS Current(AMPS) Voltage 15cd 30cd 75cd 110cd DC 16-33VDC 0.064 0.098 _ 0.175 0.233 FWR 16-33VRMS 0.108 0.164 0268 0.368 ®UL and®ULC listed Ratings OPerati9 Voltage Voltage Range Strobe Model (Spic ) [Per®ULC-S526-02] Candela [Per®UL1971] (VDCNRMS) (cd)(VDCNRMS) ST-MC-CW 16.0-33.0 20.031.0 15/30175195 Current Ratings Maximum RMS Current(AMPS) Voltage 15cd 30cd 75cd 95cd DC 16-33VDC 0.064 0.111 0.200 0264 FWR 16-33VRMS 0.117 0.180 0.297 0.398 Details for Ordering — (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Description Mounting UL ULC FM CSFM Number Number Options* ST-MC-CW 500-636098 Strobe:Candela White,Ceiling B,D,E,F,G,J,N,R,X X X X X ST-HMC-CW 500-636097 Strobe:Hi Multi-Candela White,Ceiling B,D,E,F,G,J,N,R,X X X X X ST-MC-RETRO-R 500-636103 Strobe:Multi-Candela Retro Plate,Red D,E,Z X X X X ST-75-CR-WP 500-636104 Strobe:Weatherproof Red,Ceiling T,T+WPS-KIT,GG X X X X ST-75-CW-WP 500-636105 Strobe:Weatherproof White,Ceiling T,T+WPS-KIT,GG X X X X ST-75-R-WP 500-636106 Strobe:Weatherproof Red,Wall T,T+WPS-KIT,GG X X X X ST-75-W-WP 500-636107 Strobe:Weatherproof White,Wall T,T+WPS-KIT,GG X X X X ST-HMC-CR-WP 500-636177 Strobe:Hi Multi-Candela T,T+WPS-KIT,GG X X X X Weatherproof Red,Ceiling Strobe:Hi Multi-Candela ST-HMC-CW-WP 500-636178 Weatherproof White,Ceiling T,T+WPS-KIT,GG X X X X ST-HMC-R-WP 500-636179 Strobe:Hi Multi-Candela T,T+WPS-KIT,GG XX X X Weatherproof Red,Wall ST-HMC-W-WP 500-636180 Strobe:Hi Multi-Candela T,T+WPS-KIT,GG X X X X Weatherproof White,Wall ST-MC-CNMA 500-636141 Strobe: MNS Amber White,Wall(Alert) B,D,E,F,G,J,N,R,X X X — X Strobe: MNS Amber White, ST-MC-RETRO-CNMA 500-636144 Retrofit Plate—Wall(Alert) D,E,Z X X — X ST-MC-R-AR 500-650224 Strobe:Agent-Release Only,Red B,D,E,F,G,J,N,R,X X X X X X =listed I approved *=Refer to catalog sheet#:2585 for detailed mounting options SIEMENS Industry, Inc. Building Technologies Division Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario December 2009 Building Technologies Division Tel:(973)593-2600 (SII-FS) L6T 5E4/Canada Supersedes sheet dated 7/07 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.1) URL:www.SBT.Siemens.com/FIS FAX:(905)799-9858