Plans /6u f)>1(. -WI) 7 /, WALL SIGN DESIGN S 4 L % /5/'( K,/ Scope of work is for the design of the connection of the interior wall sign to the existing structure only. tvJ 113` OM YOUR PERSONAL JEWELER SINCE 1912 Cleat Locations 15'-01/2- ti ? 4�sn YOUR PERSONAL JEWELER SINCE 1912 Design Pressures: Cleat Locations F= -5.00 psf 1/4" DIA. ROD WITH TOGGLER THROUGH Sign Dead Load= 4.00 psf(max) SHEETROCK, TYP. AT 3' O.C. ALONG TOP Fastener Capacities: AND BOTTOM OF SIGN Tc=' 89 lb Vc= 81 lb .05) PROFe Max trib.area= 9.47 ft2 =1/(((-5*-1)/891b+4/811b) � ‘ C' t N FR /� 44' 725 PE Sign Geometry: Height= 3 ft Width= 15.25 ft Iry /4 Area= 45.8 ftZRy g ti �� Space anchors along top and bottom of sign "44.,/ U � #of fasteners= 5 required(min.) JOSEPH N1`Q' Fastener spacing= 73 in o.c.(max)along top and bottom of cabinet,(15.25'•2)'12/(5 fasteners) Actual Spacing= 36 in EXPIRES:12-31-2016 Provide 0.25"dia.Rod with Snaptoggle Toggler at 36"o.c.along top and bottom of sign 9570 SW Barbur Blvd Project Name Ben Bridge Wall Signs Project# 160450 Suite One Hundred Portland,OR 97219 Location 9585 SW Washington Square Road, Space 405, Portland, Oregon MILLER Client Tube Art Group Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJM4/12/16 4/12/16 1 of 1 www.miller-se.com By Ck'd Date Page ENGINEERS GENERAL THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD.ANY MATERIAL NOT AS SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE DESIGNED BY OTHERS. SCOPE OF WORK IS FOR THE DESIGN OF THE CONNECTION OF THE WALL SIGN TO THE EXISTING STRUCTURE ONLY. SPECIAL INSPECTION OF WELDS AND POST INSTALLED ANCHORS ARE TO BE PROVIDED BY A SPECIAL INSPECTION AGENCY AS REQUIRED BY THE BUILDING OFFICIAL FOR ELEMENTS OF THE PROJECT THAT DO NOT MEET THE APPROVAL OF CONSTRUCTION OF A MINOR NATURE OR AS WARRANTED BY CONDITIONS IN THE JURISDICTION (SECTION 1704.2, EXCEPTION 1). CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. BUILDING CODE ALL PHASES OF THE WORK SHALL CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE, BASED ON THE 2012 INTERNATIONAL BUILDING CODE, INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. 40Gp'PROFess/o 4er 725 PE 4g ''� "Ps: ti R� Osof <t- ✓OSEPH Mai` EXPIRES:12-31-2016 9570 SW Barbur Blvd Project Name Ben Bridge Wall Signs Project# 160450 Suite One Hundred Portland,OR 97219 Location 9585 SW Washington Square Road, Space 405, Portland, Oregon Client Tube Art Group MILLER Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJMIL+hM 4/12/16 www.miller-se.com BY Ck'd Date Page ENGINEERS DESIGN LOADS THE FOLLOWING ARE THE DESIGN REQUIREMENTS: STRUCTURAL DESIGN CRITERIA RISK CATEGORY II LATERAL LOAD: 5 PSF ALUMINUM ALL STRUCTURAL ALUMINUM SHAPES AND PLATES TO BE 6061-T6.ALL WELDS TO USE 4043 ALUMINUM FILLER ALLOY. A PROTECTIVE BARRIER SHALL BE PROVIDED BETWEEN ALL STEEL AND ALUMINUM TO PREVENT CORROSION.ALL WELDING TO CONFORM TO AMERICAN WELDING SOCIETY(AWS)D1.2.WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE ALUMINUM DESIGN MANUAL.WELDING SHALL BE BY AWS CERTIFIED WELDERS FOR WELD TYPES SPECIFIED.WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED.ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS UNLESS NOTED OTHERWISE ON STRUCTURAL DRAWINGS.ALL WELDS TO RECEIVE THE SAME FINISH COAT AS THE MEMBER BEING WELDED.ALL FASTENERS IN CONTACT WITH ALUMNIUM TO BE TYPE 304 STAINLESS STEEL WITH MATCHING NUTS OR HAVE A PROTECTIVE BARRIER TO PREVENT CORROSION. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION. ,4D PROpe I NFFI� 725 PE t ice' ,,• ,,N oo e<cy Y 05 :t. Q JOSEPH\ EXPIRES:12-31-2016 9570 SW Barbur Blvd Project Name Ben Bridge Wall Signs Project# 160450 Suite One Hundred Portland,OR 97219 Location 9585 SW Washington Square Road, Space 405, Portland, Oregon MILLER Client Tube Art Group Phone 503.246.1250 CONSULTING Fax 503.246.1395 CJ MISM 4/12/16 www.miller-se.com BY Ck'd Date Page ENGINEERS