Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (52)
o M 0 y y] o.n 0 a,O . 0 ' 1.t1.4: ('' @7 mm,.,,,,, O t0 SCOPE OF WORK FIRE EQUIPMENT SYMBOL LIST ;,c/111 t i ,/.S 5 PART ROUGH-IN NOTE MOUNTING HEIGHT 1 J o INSTALL A NEW ZONED SPRINKLER MONITORING SYSTEM, SYMBOL DESCRIPTION N / CENTRAL STATION FIRE ALARM SYSTEM WHICH INCLUDES NOTIFIER SELF-CONTAINED SURFACE MOUNT 54'TO TOP OF HIGHESfi'-' �< SPRINKLER FLOW AND TAMPER VALVE MONITORING, I FACP1 FIRE ALARM CONTROL PANEL SFP-5UD 19.0"H X 16.65"W X 5.207"D USER FUNCTION AFF m CENTRAL STATION OFF-SITE REPORTING, MANUAL PULL STATION, i+/t n -1 SMOKE DETECTOR, AND MINI-HORNS. '.,f�t I l,� G.. © FLOW SWITCH BY OTHERS BY OTHERS BY OTHERS , GENERAL NOTES 1111 ® TAMPER SWITCH BY OTHERS BY OTHERS BY OTHERS 2 NOTIFIER 1 Ilk 14 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 0 MANUAL PULL STATION BNG-1R 1-GANG DEEP 46"TO CENTER AFF ,` 72 AND NFPA 70, ARTICLE 760, POWER UMITED SYSTEMS. elk 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE SYSTEM SENSOR 4-INCH OCT OR 1-GANG CEILING MOUNT !it li,„ O PHOTOELECTRIC DETECTOR 2W-B THAN ONE FLOOR SHALL BE RISER RATED. 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. SYSTEM SENSOR 4" SQUARE DEEP OR 80" MIN TO LENS BOTTOM AFT 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. M� MINI-HORN MHW 1-GANG DEEP 96" MAX TO TOP OF LENS AFF 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND 6" MIN TOP OF LENS TO CEILING LIGHTNING PROTECTION DEVICES. . 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED. 120 VOLT WATER FLOW BELL BY OTHERS BY OTHERS BY OTHERS • 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS "FIRE ALARM CIRCUIT". Approvedplans 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.4 PRIVATE MODE (NFPA 72). 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NAPA 72). 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH SECTION 14.6.2.4 (NFPA 72). NOTIFICATION CIRCUIT SCHEDULE VOLTAGE DROP CALCULATIONS N FIRE ALARM RISER DIAGRAM GKT, DEVICE LOCATION/AREA CSICUIT TOTAL WIRE NIRS VOLT VOLT ACCEPTED VOLT0) ORIGIN AMPS DIST 92E DROP AT EOL DROP DROP R fY r- -i N-1 MINI-HORNS APARTMENT NOTIFICATION FACP 0.289 690 14 1.22 19.18 YES 6.00 FACP AND NACS (TYPICAL) N-2 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00 W 0 ""'END OF LINE METHOD - VOLTAGE DROP CALCULATIONS... CITY OF TIGAnT Q I- (/) ZONE SCHEDULE © •• .4.7K Approved...• ..t t- _ ZONE DEVICE LOCATION /AREA 0 4.7K Conditionally Approved..............[ 1 > (C1) Z-1 PHOTO SMOKE AT PANEL �- G 4.7K See Letter to:Follow•..........••.•.••[ 4 Z-2 PULL PULL BY FIRE RISER �'' Attached•••••••••••••••• �' Z-3 FLOW MAIN SYSTEM FLOW ZONE8/2C FPLR I� 4.7K -1.4fi5 W I° Q Z-4 TAMPER MAIN SYSTEM TAMPER �. Permrt S��y •`�� �' 2-5 TAMPER VAULT TAMPER IrE 4.7K Ad K- / ]4r�.. - i ( J �H. O y ►7 , Date: ///. /.� (I) P B 2/2_5-1Y -/ Q 1 2 3 4 5 NOTIFIER 1 ° 4.7K FIRE ALARM OPERATIONAL MATRIX m Li_ FACP SYSTEM OUTPUTS N FACP TO TELEPHONE RJ 1 W/INTEGRAL LO TERMINAL BOARD [ I 1 DACT �S in 2 I �M +RE 4.7K p� S�P� ?�� CT1 120VAC DEDICATE �TYPICAL NAC �4p� h1P �� �yh� BY SPRINKLER RISER I 14/2C FPLR �' h P� R J �o� �o FP`��4° y y1� R•c��o (........"..3.VP . BATTERY CALCULATIONS FP°�a��° ��'�e�. {'y�. J°'s0� ° �0��+`� )Aliiirj6 3 5y NOTIFIER SFP-5UD �P��43 0�0�` SSS ����� GAN^4'A, 1/611 � STANDBY(HRS): 24 BY SPRINKLER RISER SYSTEM INPUTS PJeP,�P 4`-�fifi 4)4) vs' es NOTES: DWG REV. / DATE ALARM TIME (MIN): 5 • PULL STATION • • ' ' 0 12/13/13 SMOKE DETECTOR • • • • PART# DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL WATER FLOW • • • • SFP-5UD MAIN CIRCUIT BOARD 1 .1100 .1100 .2140_ .2140 • • ADDITIONAL 24VDC DEVICES NOT COVERED IN THE FACP CURRENT DRAW TAMPER '+f PS-DA PULL STATION 1 .0000 .0000 .0000 .0000 DRAWN BY: 2W-B PHOTOELECT DETECTOR 1 .0000 .0000 .0400 .0400 LOSS OF AC POWER AT FACP • • SMB MHW MINI-HORN 17 .0000 .0000 .0170 .2890 OPEN CIRCUIT • • CHECKED BY: STANDBY AMPS = 0.1100 ALARM AMPS = 0.5430 DISCONNECTION OF BATTERIES •, • MGH STANDBY Ah = 2.6400 ALARM Ah = 0.0453 GROUND FAULT • • , FILE NAME: AMPERE HOURS REQUIRED = 2.6853 _ . • • FA.dwg 20%DERATE = 3.2224 PRESS SIGNAL SILENCE KEY DRAWING/: BATTERIES TO BE INSTALLED = 7.0 AMPERE HOURS PRESS RESET KEY • OFFICE COPY FA-1 /OF DWGS IN SET: SHEET 1 OF 4 0Z-1 FZ-2 o n o oooi O0 .O Qw �h FACP Llat FS z-3 0 1 b r p q— r 1 J TS Z-4 SL PRINKLER i ` 111 RISER o it k UNIT 112m .- 1\1--.1 UNIT 115 N-1 CM ____,,.._ i___, N-1 yr___-1--)1.-_ I �^©\ �J OW N \ _ N h -,--r W O m N-1 J 00 0 TO ABOVE l. JM 000 ® 000 0 a LLIJ o ® O J >— „ , L .,_ ,, , ,, � ./. 0 �o,____ > 1 ,,....._, ,_ i___ L---i. m ii0 . o1 ® o8 1 N-1 (n Z H W Q a Ct m to Lnrn01 DWG REV. / DATE 0 12/13/13 VAULT TS Z-5 • DRAWN BY: SMB CHECKED BY: N MCH ,1111''" OB A S E V E N T FLOOD PLA\ 0 4' 8' 16' ALE NAME: FA.dwg 111111 1111111 SCALE: 1/8" = 1'-0" �� DRAWING SCALE: 1/8"=1'-0" PLAN FA-2 /OF DWGS IN SET: SHEET 2 OF 4 i A 4 , 1 L u 1 x, J O -:3(' '\) z co ® [ jm(;,, ---- z -, . e p �� (-- , =1 ____If: 8 \7 o (--- W&D >40tPz nD m - 1 7 C Z co /1i. -1-1 {1 rI �� r b O W O AJ Ooo 000 [A0 I 7. . mml °J z WAD \ \7 i z T D h m C s 00cci oCM by, o---. a) - tor I, a 1. a 1, ... I oan 0 z we > >q Kri N>O _ a z C SR K 1 z DRAAANCS PREPARED BY. g a>> So CO m 9 f L m < ,. . m MAINSTREET VILLAGE - oW Z D > 9356 SW MAPLEWOOD DRIVE TIGARD, OR 97223 IU'�t 5863 LAKEVIEW BLVD. #100 LAKE OSWEGO, OR 97035 �M FIRE ALARM SYSTEM Mondor (503) 627-0,00 [7 4i iPPORATEIN m FIRE ALARM SYSTEM Monitor (503) 627-0100 C.rl CORPORATUN 7 OLI,O ono I' L, Y 111111.11 _IQ 1lba� T • 1MN-i rn% UNIT 114 N-1 1 M UNIT 117 r ©'N-1 I�—\, a o ' _ , Dw N Ep. .m) N 11 Cn N-1 —•a •o o LIJ o M E__ M ooh 0 - 000 0 6 w a V) r L. ® oo _J E. 10II > cc } W E W O J M W o Q 0 o L_ o N-1 Q FROM BELOW I ZLK_____,: a LU CY M < < O N-1 N-1 M Iii I OL • coin c rn 0 QO DWG REV. / DATE 0 12/13/13 /I DRAWN BY: SMB CHECKED BY: • N MCH IMI'' iIliIll 1 UPPER E L 0 0 PLAN 0 4' 8' 16' FILE NAME: 111101 111111 SCALE: 1/8"= 1'-O" m FA.dwg I. .. ." 1" .1" DRAWING/ PLAN SCALE: 1/8"=1'-0" FA-4 /OF DWGS IN SET: SHEET 4 OF 4