Loading...
Report (25) P 5 R01 (e - OO pa (--/ RECEIVED Lt11C0 Worldwide Fire Protection FR 1 7 2016 Contacts www.tyco-fire.com Products (ATV OF TIG'ARD Series TY-FRB — 2.8, �M;NU��; end 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General spheres.Although corrosion-resistant coated sprinklers have passed the Description standard corrosion tests of the appli- cable approval agencies,the testing is 7 d# IN The TYCO Series TY-FRB, 2.8, 4.2, not representative of all possible cor- '. • 5.6, and 8.0 K-factor, Upright, Pen- rosive atmospheres. Consequently, i ! dent, and Recessed Pendent Sprin- it is recommended that the end user 1' klers described in this data sheet are be consulted with respect to the suit- t , ,. quick response, standard coverage, ability of these coatings for any given - decorative 3 mm glass bulb-type spray corrosive environment.The effects of ;II �' - sprinklers designed for use in light or ambient temperature,concentration of . _ _ t ordinary hazard,commercial occupan- chemicals,and gas/chemical velocity, cies such as banks, hotels, and shop- should be considered, as a minimum, ping malls. along with the corrosive nature of the chemical td which the sprinklers will be The recessed version of the Series TY- exposed. FRB Pendent Sprinkler,where applica- ble, is intended for use in areas with a An intermediate level of the Series TY- ' finished ceiling.This recessed pendent FRB Pendent Sprinklers is detailed sprinkler uses one of the following: in Technical Data Sheet TFP356, and f uUe. Sprinkler Guards are detailed in Tech- ,- u:. • A two-piece Style 10(1/2 inch NPT) nical Data Sheet TFP780. i or Style 40(3/4 inch NPT) Recessed ' 1 j!:4 - Escutcheon with 1/2 inch(12,7 mm)of NOTICE ! recessed adjustment or up to 3/4 inch .g (19,1 mm)of total adjustment from the The Series TY-FRB, 2.8, 4.2, 5.6, -, ,---, ., j flush pendent position,or a and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers • A two-piece Style 20 (1/2 inch NPT) described herein must be installed or Style 30(3/4 inch NPT)Recessed and maintained in compliance with Sprinkler Escutcheon with 1/4 inch(6,4 mm)of this document and with the applica- recessed p adjustment or up to 1/2 inch ble standards of the National Fire Pro- Identification (12,7 mm)of total adjustment from the tection Association, in addition to the flush pendent position. standards of any authorities having Number (SIN) The adjustment provided by the jurisdiction.Failure to do so may impair Recessed Escutcheon reduces the the performance of these devices. TY1131: Upright 2.8K, 1/2"NPT accuracy to which the fixed pipe drops The owner is responsible for maintain- TY1231: Pendent 2.8K, 1/2"NPT to the sprinklers must be cut. ing their fire protection system and TY2131: Upright 4.2K, 1/2"NPT Corrosion-resistant coatings, where devices in proper operating condition. TY2231: Pendent 4.2K, 1/2"NPT applicable, are utilized to extend the The installing contractor or sprinkler TY3131: Upright 5.6K, 1/2"NPT life of copper alloy sprinklers beyond manufacturer should be contacted with TY3231: Pendent 5.6K,1/2"NPT that which would otherwise be obtained any questions. TY4131: Upright 8.0K,3/4"NPT when exposed to corrosive atmo- TY4231: Pendent 8.0K,3/4"NPT TY4831: Upright 8.0K, 1/2"NPT TY4931: Pendent 8.0K, 1/2"NPT IMPORTANT Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING"that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 OCTOBER 2013 TFP171 VII TFP171 « Page 2 of 10 . *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing I / 1 7/16"0 ��1' . (11,1 mm) �;1,1�'` 3 i NOMINAL , 2-1/4" ��L iii i �r 2 °1 MAKE-IN (57,2 mm) I • II 2-3/16" 4 1 (55,6 mm) I if 1-9/16". (39,7 mm) 11 r5 - \ ii ■% 1� ii-■ '� :- i --6* 1/2"NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE T1\ 7/16" ��1'(11,1 mm) A 1 NOMINAL 2-3/16"1 / rMAKE IN 1 (55,6 mm) Iiif ; 0� 2 3/16" 1-1/2" 41 !=, (55,6mm) li (38,1mm) • 5 In 1/2"NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(7Y2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE 7/16" ——--—---- 11111Wii-- ._------------------ Emir_ P pt 3 (11,1 mm) . rr NOMINAL I � 2 3/16" � � 42 MAKE-IN (55,6 mm) IN I�� 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) I=_!-------5 _ - 6* 1/2" NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS - 5.6 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2" I / off �� 4 F 3 (12,7 mm) A MAKE- NOMINAL ..0 2-5/16" �� d 2 1 (58,7 mm)OA s 1 2-1/4" I 1-9/16" 1 4 (57,2 mm) . (39,7 mm) . f`___________5 3/4"NPT** t WRENCH STYLE 30 or 40 6 FLATS RECESSED 2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT ti TFP171 Page 4 of 10 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* - ��•� —-�y� Assembly ,E �f 3 4 - Bulb 7/16" /72-1/4" J f* 1 (11,1 mm) I (57,2 mm) %� A 2 NOMINAL I — MAKE IN I I * Temperature rating is r �1 2 3/16" 1 9/16" 4 indicated on Deflector. (55,6 mm) i ii (39,7 mm) C1,--5 ** Pipe thread connections -__-• _„'iii`\` * per ISO 7 1 can be 6 provided on special 1/2"NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES 7Y-FRB UPRIGHT(7Y4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Design torque can distort the sprinkler Inlet with consequent leakage or impairment Data Criteria of the sprinkler. Do not attempt to compensate for ' Approvals The TYCO Series TY-FRB, 2.8, 4.2, insufficient adjustment in the Escutch- UL and C-UL Listed 5.6, and 8.0 K-factor, Upright, Pen- eon Plate by under-or over-tightening FM, LPCB, and NYC Approved dent,and Recessed Pendent Sprinklers the sprinkler. Re-adjust the position of Refer to Table A and B for complete are intended for fire protection sys- the sprinkler fitting to suit. - approval information including tems designed in accordance with the corrosion-resistant status. standard installation rules recognized Series TY-FRB Upright and Pendent by the applicable Listing or Approval Sprinklers Maximum Working Pressure agency (such as, UL Listing is based The Series TY-FRB Pendent and Refer to Table C. on the requirements of NFPA 13, and Upright Sprinklers must be installed FM Approval is based on the require- in accordance with the following Discharge Coefficient ments of FM's Loss Prevention Data instructions. K=2.8 GPM/psilI2 (40,3 LPM/barl12) Sheets). Only the Style 10, 20, 30, or Step 1.Install Pendent sprinklers in the K=4.2 GPM/psi1i2 (60,5 LPM/barl'2) 40 Recessed Escutcheon,as applica pendent position. Install upright sprin- K=5.6 GPM/psi112 (80,6 LPM/bar112) ble,is to be used for recessed pendent K=8.0 GPM/psi112 (115,2 LPM/bars/2) installations. klers in the upright position. Step 2. With pipe-thread sealant Temperature Rating Installation applied to the pipe threads, hand- Refer to Table A and B. tighten the sprinkler into the sprinkler The TYCO Series TY-FRB, 2.8, 4.2, fitting. Finishes 5.6,and 8.0 K-factor,Upright, Pendent, Step 3.Tighten the sprinkler into the Sprinkler: Refer to Table D. Recessed and Recessed Pendent Sprinklersmust sprinkler ighg using ri thekW-Type 6 Escutcheon:White Coated, Chrome be installed in accordance with this Sprinkler Wrenchg onlynigure 14).With refer- ence .. Plated, or Brass Plated. section. to Figures 1 through 5,apply the Physical Characteristics General Instructions W-Type 6 Sprinkler Wrench to the sprin- Frame Bronze Do not install any bulb-type sprinkler if kler wrench flats. Button Brass/Copper the bulb is cracked or there is a loss Sealing Assembly Beryllium of liquid from the bulb.With the sprin- Series TY-FRB Recessed Pendent Nickel w/TEFLON kler held horizontally,a small air bub- Sprinklers Bulb Glass ble should be present. The diameter The Series TY-FRB Recessed Pendent Compression Screw Bronze Sprinklers must be installed in accor- Deflector Copper/Bronze of the air bubble is approximately 1/16 pp inch(1,6 mm)for the 135°F(57 C)and dance with the following instructions. Bushing(K=2.8) Bronze 3/32 inch(2,4 mm)for the 286°F(141°C) Step A.After installing the Style 10,20, Operation temperature ratings. 30, or 40 Mounting Plate, as applica- A leak tight 1/2 inch NPT sprinkler joint ble,over the sprinkler threads and with The glass bulb contains a fluid that shold be obtained by applying a min- pipe-thread sealant applied to the pipe expands when exposed to heat. When imum to maximum torque of 7 to 14 threads,hand-tighten the sprinkler into the rated temperature is reached, the ft.-lbs. (9,5 to 19,0 Nm). A leak tight the sprinkler fitting. fluid expands sufficiently to shatter the 3/4 inch NPT sprinkler joint should be Step B.Tighten the sprinkler into the glass bulb, allowing the sprinkler to obtained with a torque of 10 to 20 ft.- sprinkler fitting using only the W-Type - activate and water to flow. lbs. (13,4 to 26,8 Nm). Higher levels of 7 Recessed Sprinkler Wrench (Figure TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) KBULB LIQUID NATURAL CHROME SIGNAL*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED WHITE 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 UPRIGHT (93°C) Green 200 F(93 (TY1131) ° ° 286°F(141°C) Blue 135°F(57°C) Orange • 2.8 RECESSED C) Red 1/2" 155°F 68 ° ( °NPT PENDENT (TY1231)* 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 1,2,4 135°F(57°C) Orange RECESSED ° 155F(68 C) Red PENDENT ° (TY1231)** 175°F(79°C) Yellow Figure 7 200°F(93°C) Green 135°F(57°C) Orange • PENDENT (TY2231) 155°F(68°C) Red and 175°F(79°C) Yellow UPRIGHT ) (TY2131) (200°F 93°C Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 RECESSED 155 1/2" 155°F(68°C) Red 1,2 NPT PENDENT ° (TY2231)* 175°F(79°C) Yellow Figure 8 • 200°F(93°C) Green 135°F(57°C) Orange RECESSED F 155 68 C) Red PENDENT 155°F( ° (TY2231)** 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. •Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. —*Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10,20,30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 . Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME SIGNAL*** LEAD _ FACTOR COLOR BRASS PLATED WHITE COATED 135°F(57°C) Orange PENDENT TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F(93°C) Green (TY3131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 5.6 PENDENT 175°F(79°C) Yellow 1,2,4,5 N/A 1/2 NPT (TY3231) Figure 10 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red (TY3231NT 175°F(79°C) Yellow 1,2,3,4,5 N/A Figure 11 200°F(93°C) Green 286°F(141°C) Blue . 135°F(57°C) Orange PENDET (TY 2311) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT (TY4131) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 8.0 PENDENT 175°F(79°C) Yellow 1,2,5 N/A 3/4 NPT (TY4231) Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red TY4231NT 175°F(79°C) Yellow 1,2,3,5 N/A Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDT (TY 981) 155°F(68°C) Red 1/28 NPT and 175°F(79°C) Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. 'Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. *'*Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B - LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS w c TFP171 Page 7 of 10 SPRINKLER FINISH • K TYPE NATURAL CHROME SIGNAL LEAD FACTOR BRASS PLATED WHITE COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and UPRIGHT(TY2131) 4.2 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and UPRIGHT(TY3131) 250 PSI(17,2 BAR) (12,1 BAR) 5.6 OR 175 PSI(12,1 BAR) — 1/2"NPT (SEE NOTE 1) RECESSED N/A PENDENT(TY3231) PENDENT(TY4231) 175 PSI and UPRIGHT(TY4131) (12,1 BAR) 8.0 ••-, 175 PSI(12,1 BAR) 3/4"NPT RECESSED N/A PENDENT(TY4231) PENDENT(TY4931) 1/2"NPT UPRIGHand T(TY4831) 5 PSI 175 PSI(12,1 BAR) (121 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and corrosive products of combustion, but tion Service in accordance with local have not operated,should be replaced requirements and/or national codes. if they cannot be completely cleaned Maintenance Care must be exercised to avoid dam- by wiping the sprinkler with a cloth or The TYCO Series TY-FRB must be by brushing it with a soft bristle brush. age to the sprinklers -before, during, and after installation. Sprinklers dam- maintained and serviced in accordance Care must be exercised to avoid dam- aged by dropping, striking, wrench with this section. thesprinklers- before, during,to sp e s twist/sli a e, or the like, must be and after installation.Sprinklers dam- PP g Before closing a fire protection system P � replaced. Also, replace any sprinkler main control valve for maintenance aged by dropping, striking, wrench that has a cracked bulb or that has lost work on the fire protection system twist/slippage, or the like, must be liquid from its bulb. (Ref. Installation that it controls, obtain permission to replaced. Also, replace any sprinkler Section). shut down the affected fire Protection that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Initial and frequent visual inspections of systems from the proper authoritiesbq random samples are recommended for and notify all personnel who may be Section.) s affected by this action. The owner is responsible for the thecorrosion-resistantintegrity ityof o sprinklers atverifya P the integrity of the corrosion-resistant Absence of the outer piece of an inspection,testing,and maintenance of material of construction. Thereafter, escutcheon, which is used to cover their fire protection system and devices annual inspections per NFPA 25 should a clearance hole, can delay sprinkler in compliance with this document, as suffice. operation in a fire situation. well as with the applicable standards of the National Fire Protection Associa- Inspections of corrosion-resistant Sprinklers which are found to be leak- tion (e.g., NFPA 25), in addition to the sprinklers are recommended at close ing or exhibiting visible signs of corro- standards of any other authorities hav- range, instead of from the floor level sion must be replaced. ing jurisdiction. Contact the installing per NFPA. Inspection at close range Automatic sprinklers must never be contractor or sprinkler manufacturer can better determine the exact sprin- painted, plated, coated, or other- regarding any questions. kler condition and the long-term integ- wise altered after leavingthe factory. rity of the corrosion-resistant material, Y Automatic sprinkler systems are rec- which can be affected by the corrosive Modified sprinklers must be replaced. ommended to be inspected, tested, conditions present. Sprinklers that have been exposed to and maintained by a qualified Inspec- TFP171 . Page 8 of 10 . 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 6,4 mm 1/4"(6,4 mm) (12,7±3,2 mm) 1/4" 2-1/4"DIA. 2 1/4"DIA. ( ) / FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" f (3,2 mm) (3 mm) � 1 1 _ Z,41.1__ MOUNTING ' Ir f MOUNTING SURFACE IP SURFACE ii�I�. ����N.i. CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16'(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8'DIA. _ 2-7/8'DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 1/46,4 mm" �-2-1/4"DIA. -y 2 1/4'DIA. ( ) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 411_ / 1/8" / 1/8" (3,2 mm) (3,2 mm) ��_i ___I Vir , J 1 \ MOUNTING1�r .MOUNTINGSURFACE SURFACE • CLOSURE SERIES 1-1/4'(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT s' TFP171 Page 9 of 10 2-7/8"DIA. - 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8` (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 1/4"(6,4 2-1/4"DIA. 2-1/4"DIA. mm) / FACE OF (57,2 mm) MOUNTING / FACE OF F (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" / 1/8" (3,2 mm) 20_ _ (3,2 mm) �� f \ ,,, MOUNTING ,�' MOUNTING 4 ��_ SURFACE - SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4'(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 2-7/8"DIA. - (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2'(12,7 mm) 5/8±1/4" 1/2±1/8" (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) / (57,2 mm) MOUNTING / FACE OF (57,2 mm) 1 MOUNTING FACE OF ' SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8' 1/8" / (3,2 mm) / (3,2 mm) l r 7/;/ i. ror,.... . mr.111 .4_7 1•- --..-=---e LI I I 7 7 7 7/: ' '�. MOUNTING MOUNTING L_. MI Af SURFACE SURFACE � 1 CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16'(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3M INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3M INCH NPT 8.0 K-FACTOR,3M INCH NPT Gv WRENCH RECESS WRENCH RECESS (END"A" USED FOR /!41 ,/.... 1/2"NPT MODELS) • t WRENCH RECESS (END"B"USED FOR 3/4° NPT MODELS) PUSH WRENCH • IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 3 PURE WHITE 155 155°F(68°C) (RAL9010)' 340 4.2K UPRIGHT(1/2"NPT) TY2131 4 SIGNAL WHITE 175 175°F(79°C) (RAL9003) 341 4.2K PENDENT(1/2"NPT) TY2231 5 JET BLACK 20G 200°F(93°C) (RAL9005)" 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 *Eastern Hemisphere sales only. **Available in only 2.8K,4.2K,and 391 8.0K PENDENT(3/4"NPT) TY4231 8.0K,155°F(68°C)and 200°F(93°C); requires lead time to manufacture. 360 8.0K UPRIGHT(1/2"NPT) TY4831° 361 8.0K PENDENT(1/2"NPT) TY4931° TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB(Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N(specify from Table D) Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N(specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 *Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright 0 2013 Tyco Fire Products,LP. All rights reserved. -two TEFLON is trademark of The DuPont Corporation. Fire Protection Products