Correspondence Dan Nelson
From: Albert Shields
Sent: Tuesday, October 06, 2015 1:57 PM
To: Walter Barnett; Dan Nelson
Cc: Mark VanDomelen
Subject: FW: Permit#BUP2015-00284
Attachments: 215236 ASI.pdf
I'm not sure what you want to do with this. Permit was just issued to create warehouse space. Albert.
From: Russell Finley [mailto:rfinley@aIrsarchitects.com]
Sent: Tuesday, October 06, 2015 1:40 PM
To: Albert Shields
Subject: Permit #BUP2015-00284
We discovered that the building was not sprinklered as indicated on the permit drawings. Attached is a stamped
revision to the drawings. Please let us know if you need additional information. I have send the contractor the revision
so he can update his drawings on site.
Thanks,
Russell Finley I Senior Interior Designer I LRS Architects Portland I Shanghai
503.265.1521 direct• 720 NW Davis Street Suite 300• Portland,OR 97209•www.lrsarchitects.com • vCard
Please consider the environment before printing this e-mail
DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail
may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained
by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule."
City of Tigard
Apptrov d Plans
By Date to
111.
( 2( 7 G30
REVISION , ,
OFFICE COPY � \ 1,4
\\
1
. ._
PROJECT SUMMARY CODE SUMMARY (SERE EGRESS PLAN BELOW)
V. EMERGENCY SYSTEM STANDARDS: REQUIRED EXITS PER SECTION 1015
1. NOT USED.
OCCUPANCY : . - ; • REQUIRED PROPOSED
BIS-1 1 2
2 IN BUILDINGS WITH EXISTING SMOKE DETECTORS: 1 1
PROVIDE CODE MINIMUM CORRECTIONS AS
REQUIRED.SMOKE DETECTORS TO BE TIED TO THE EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER
BUILDING ALARM SYSTEM. TABLE-1016.2
3. IN BUILDINGS EQUIPPED WITH AN E IST1NG VISUAL •
STROBE SYSTEM:PROVIDE CODE MINIMUM OCCUPANCY - - - ..., PROPOSED
CORRECTIONS AS REQUIRED.IFA SYSTEM DOES NOT
EXIST,DO NOT ADD ONE. B/S-1 N 200'MAX
4. PROVIDE EMERGENCY EGRESS UGHTING FOR THE
EGRESS PATH IN ALL PUBLIC AND TENANT SPACES. 1
MINIMUM INTENSITY SHALL NOT BE LESS THAN 1
FOOTCANDLE AT FLOOR LEVEL ALONG THE ENTIRE
LENGTH OF THE PATH. CONNECT TO BUILDING
ELECTRICAL SYSTEM.
5. PROVIDE EXIT SIGNAGE.EXIT SIGNAGE SHALL BE
CONNECTED TO BUILDING POWER SUPPLY WITH
BATTERY BACK-UP FOR MIN 1-1t2 HOUR ouRAnoN. DEFERRED SUBMITTALS - DESIGN BUILD
6. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS
AS REQUIRED. ELECTRICAL SYSTEMS (1:;
MECHANICAL SYSTEMS
400
SPEC TENANT- PARK 217 REFERENCEA001
Lrs720 NW Dols ADDRESS: 12178 SW GARDEN PLACE
Bulls 300: Poland OR B7209 PROJECT NUMBER 215236
%MUMN ARCHITECTS 503.221.11212 DATE ISSUED 10.06.15
.
IN vs www.hsurdiNicb oom 903.221.2077OF
IRS Inc.02014 AS! 01
rw.at.e•ar-rlOWNNAMPtim.rv.nn. .g174117me0.-riall. .wn0MIA"
RCP GENERAL NOTES
1. ALL ELECTRICAL WORK IS DESIGN BUILD-EXISTING&NEW LIGHT
FIXTURES SHOWN FOR REFERENCE ONLY. VERIFY EXISTING
CONDITIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT.
SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO
CONSTRUCTION. CLEAN&RESTORE ALL LIGHTS TO WORKING
ORDER PRIOR TO JOB COMPLETION.
2. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING&NEW
DIFFUSERS SHOWN FOR REFERENCE ONLY. VERIFY EXISTING
CONDMONS AND REPORT ANY DISCREPANCIES TO ARCHITECT.
SUBMIT MECHANICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO
CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB
COMPLETION.
3. SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING,
STROBES&SMOKE DETECTION TO ARCHITECT FOR REVIEW AND
COORDINATION PRIOR TO CONSTRUCTION.
1
4. REPLACE ALL DAMAGED CEILING TILES&GRID TO MATCH EXISTING
BUILDING STANDARD.
5. WHERE NEW LIGHTS ARE ADDED-MATCH EXISTING BUILDING
STANDARD TYPE AND FINISH.
40,0
SPEC TENANT- PARK 217 REFERENCE A202
flEIEUE C` T 720 NW Davis ADDRESS: 12178 SW GARDEN PLACE
X011111 4 • P2iArtl�■r 300 OR 97200
NNW*
NUMBER 215238
ILO `o ARCHITECTS 503.221.1121S DATE ISSUED: 10.08.15
OF
ASI 02
NUE 12Ap.•00.144 r/M.Mewlo L,r,.7p7.Wy 7.171N1100,0mt-M7MAYOApbO7Matas,