PFI2016-00069 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12016-00069
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/30/2016
Parcel: SEG1933
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: Comcast
Project Description: Adjacent to 14605 SW 88th Ave. Boring 302'from existing CATV at 8810 SW Pinebrook Dr to 14605
SW 88th Ave existing CATV.
Owner: FEES
Description Date Amount
PFI Permit Fee 03/30/2016 $300.00
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
IVAN CHANDLER
11308 SW 68TH PARKWAY
TIGARD, OR 9722
PHONE: 971-777-0908
Total $300.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant Not Present
Signature:
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12016-00069
Type: Condition Name: Status: Severity:
PFI—Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches,etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection,and after completing work covered by the permit.
Kenny Smith at 503.816.6146
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
RECEIVED
MAR 2 8 2016
City of Tigard CITY OF TIGARD
P! A^lN!!�Y73!ENGINEERING
� PUBLIC WORKS — ENGINEERING
Public Facility Improvement (PFI) Permit
DESCRIPTION OF WORK(in the right-of-way) TYPE OF WORK
Check one: G6tihty Connection TYPE 1-Franchise Utility Work
❑ Sidewalk/driveway approach Mork performed by NWN,PGE
❑ Street improvements and/or utiliry agency-
Detailed description: . r-eolm el1ST AXi E] TYPE 2-Sidewalk/Driveway/Sewer
CA-K( A-"( St5lC-7 SW I'INEC la01�- Pe TO Work performed for the purpose of:
O� W A\1 i f u .A�� - Sidewalk installation or repair.
1' • Driveway approach installation
Property address/location(s):
Sw g Q/ i and/or repair
• Sanitan sewer lateral installation
and/or main line tap
❑ TYPE 3-Full scale Development
Applicant: C'kcsf LE1L- \X'ork performed with Land use
approval which includes any of
Address: ((3 S uJ �//� f 2�`��I the following:
City/state: � /p tJ C— Zip: 72-2 3 - Subdivisions or Partitions
Phone:g71-777'GIV6 Lmail: iVA" cAl-01 CA5"r' `�`" • Street widening
Contact name: t0t� I Ca1S.A VLAF& Phone: • Mainline installation for Sanitary
sewer,Storm sewer,Tigard water
Contractor: 71 L ITI�s and/or Tigard\Fater SerNice.1rea
CCB#: 2 Ub q$ h.xpiration: t -7 SUBMIT COMPLETED APPLICATION TO:
Address: 19 I O SC 9 i4"' AJC City of Tigard
City/state: C,*r 4A5 �W R 29(o0-7 9(00-7 Planning/Engineering
13125 SW Hall Blvd.
Phone:-5 -21(0-9446 Email: b me=w X1_LZ- O NIL-6LXrre5.6ow1 Tigard,OR 97223
Contact name: -CG l Phone: \ppltcanons for"miner work in nght-of-%%,a%"
only matbe emailed to:
rownp r m i t s(jtlgard-o r.g o V
Engineer:
Address:
Cite/state: zip: / )_
Phone: Email: Case No.:
Contact name: application subrtuttal fee: "
Addluonal fees:
Estimated value of work is required(if over S5,000):$ Application accepted:
(within the public right-of-way) By: �` Date: 2 04,v
Applicatiog reyzewid:
Is work related to a LAND-USE DECISION? ❑ les 21<10B\ <_. ! Dare: S L
Z-a} �!
If so,please specify (NILP,SDR, SUB, etc.) case #:
Apphl tified: 3`Zq
Is work related to a BUILDING PERMIT? El Yes PKo By: I14 re Date:
If so,please specify(BUILDING PERN111)case#: \CURPLN\Marten\Lend UW Appl"Wffl Rev 07/09/2015
City of Tigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 • w•ww:tigard-ongov - 503-7,18-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as ".-Applicant"shall be designated"Pernuttee"and shall provide financial assurance for work.
W11C11 the owner and the applicntir zire different people,the applicant must be the purchaser of record ora lessee in possession with written
authorization fro"] 111C owner of 1171-,1gC11t 0f the OWI!Cr. ThCowllcr(s)mum S4111 this application in the space povided or submit a written
authorization with this application.
BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT:
• The above reqtiest does nor violate any deed rcstriction's that tn;v.,be attachcd to or imposs:d upoil the sitbiect properti.
• If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to 111 the
conditions and limitations of the approval.
• A0 of the above statements and the statements in the plot plait,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is f6tirid that im-such
statements are false.
• The applicant has read the entire contents of theapplicirion,including the policies and criteria,and understands the
requirements for approving or denying the application.
SIGNATURES of each owner of the subject property required.
itit1/ALithon'zed Agent's signature Print mane Date
0xvner's signature Print name Date
Owner's signature Print 11111me Date
Owner's signature Print narne Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard - 13125 S\V]]all Blvd. - '1*igardJ)regon91223 - vm,-\v.tigajd-or.gov 503-7/18-2421 - Page 2of4
COMCAST
SPAN REPLACEMENT
14635 SW 88th AVE.
TIGARD, OR.
CONTACTS S=wF SHEET INDEX
s S"� No. DESCRIPTION
IVAN CHANDLER ` a
COMCAST CABLE S.McU.nafds: o-- "SWMCDanaldSi SWWoonaldsl FMO /Mp ��� 1 COVER
CONSTRUCTION DEPT. �, 2 STANDARD LEGEND
11308 SW 68th PARKWAY svr s s: -
TIGARD, OR. 97223 3 GENERAL NOTES AND
CELL 971-777-0908 SWMan ��-� "p TYPICAL TRENCH DETAILS
ivan—chandler@coble.comcast.com ,,� ,.b�h,� a 4 PLAN
' 9 3
LARRY FOSTER JOB SITE
NX UTILITIES swrc.s, swrc.s swuris swlns� sweomm�d - swearaaaa
FIELD SUPERVISOR
1910 SE 8th AVE Swm,M�s ,K ,pdkSd�. r�.or.m {
CAMAS WA. 98607 n,swr.bv..u, swv„Ke am n, �
Ph: 360-335-5201 MxdMSI -
LFOSTER@nxutilities.com
.;s Dor a
�a” F
SW SUUn 51 ---- SW Sanler 5l --5W SnNer SlSW Sattlrl 5l SIN Sanlerh 'SM
sr,wt,—
VICINITY
t,nVICINITY MAP
TWNSEC: 2s DIAL 811 W.O.: 47894
SEC: 11
1947 CLAXTER RD NE RNG: IW
ND UTILITIES SALEM,OR CALL LOCATE SHT 1
PH: 971.800.0807
FAX:971.275.1882 BEFORE YOU
DRWN: DET DIG OF 4
nxutlllties.com SCALE:NONE DATE: 2116116
TYPICAL LINE TYPES
SYMBOL LEGEND
CpJIE/JURE
Cln 1L113 qty Lmm WRUpJr/BRwS$CM ® rF1FA1o1E POIf-IX51e1c G
CURB/0.1TIFA
afCM ORa1 aIICM 81131 CURB W1Ff JbM USE PIXE-EJ15IN0
E15EYe11 E4R— .— i—_ _— —EM— —ESur � TFIJ:AIOME MHAIFR-ExaTrc
cm
FFRCE • • v v • • UTa1 8141-RELrNRRE � 1r1FP11011E PmESM.-EIOSTMG
GlMR00.4L _ _ _ _ _ - _ _ Gla1 B 9N-RU11rO • IpIPIgRE COOL PED-IX150M0
PINEYIXT EDGE STORM aVN YNUIaE
PROPFIlry URE 1F1FP1OIE SIJ-E)]511110
�� SMR ClFN1IXlr ® IFIFPIIOJE UBMET-EbSIWG
RIa1f Or eNY
9CfleLLl(
SMR uNa1aJ: O 1EIFP11aE WNO NdE-EIOSfNC
S1RfAY/SrpRF1riE
wNi, als wwo ROLE mw1oRE uwlolE-Ex5TR10 I rTJ JI
an cls'e'rn •
RJa•PaLE
a%. NR--vrt,1ssE1JBLr w.•e WIn RaE-REM 13
PORFR E E
El
SEY'ni _ R1SR_ 9E1If/1 YIhIFA WN110LE O
slaw aaw ___SIag1 :ea-r�1MR0 Rola-rew
mEP11ac _. ->a __ rurtr+vNrLT
PROPrJsm mEs.neE-HANE I¢E»1oI[wwoE-RE1P O
PRLPosm r¢E»o1E-aRem w�IEn vN.vE �
IRNr1C swtam csac Iwr ---...
ro+ wool r%a Rrpwlr ntEP1aI[uewEr-REir
LRY/LaJRrr oa.Rwrrool BwR-0r./Iu(rRa) p mEslnle Loa PEn-REw
R•rrn NEIFA p ,ElEPNORE sN-REw
ury wwo wLE ❑
ecle m
STANDARD ABBREVIATIONS STANDARD BUILD ury PrttsrJi
lrnnr Pm RaIE LourpR
r NeJ�nr,1�r.. urioEnrneurlo euan_ 0 �_ RORv+rwralc OE TcitsL�oRE ooRRary orar-nEw
n roP rno voE T%w N1c InlcwR IRErJCH/PLnw
Q Poem uerlEr � IEI(ggRE N1LH]R-MEM
rs rro sIREEr poE MN ualE N+N eolE 0 •rc Ica-EJOSIMc onRA
rP roP ReoE PoSJrgN •wet cRoss raR uJBel0Ranlo R•ln- Lam- Porro swacRccw
1�NEr oR colc+arE cur _ .___-. cuvEm
RS tt1P NSCE SRKFT 40E OG 001rn GUY %pa.
RN wP 1RoolE Pa9110N � oa,ac Llano Net amax•nN>aE,n RpR[R TRN1s,aRNEp ® mNr,t sol d
roP rov oulsnE PosnoR rys rxea rus Nlu �J Poew RN10 ralF E nne
\/ Ivc PaE 0
ED
ros wP aursnE srR¢r snE rs n¢n soE NnNi euan `/ � raRm rtrw
ec eorrou rxin snE a cw+m Na I
as conal srREEr soE ws 1elcRr of 3nN:RNErrt seal mn mc' Po.w PEOEsrN � `,..J
eP eonw•+sioE PasroR ru PwRr or•nrLRutrn PORm�-cox D] TR¢
rrs Bona+NtypE slRm snE ouc ovEJBrwo cur °` 1°a" ac-r00c�i srREn L%in
v eonou uBa[PosmoR Rs Ram swE rp+NL 1fIOP/cBL pQ
eoP eorrou aJrsoE PasilpR s1N+ lxalr oR PQYFrJ coJJPNJr envlrear RuumJTRNr1C soul axJIRLL uJRRET
rrnuL vucE Ca
Bos Bonou aursgE srnEEr snE sxu soEvwx I,vcRoa N10 an rwEric soNl Pa1E O cELL rw[R a
w.a vw,,� RER caRSIRucIIOR ^ rwEnc mra.LaaR a-eox m
Pl PALE rEIe1 TUe1111AL RprE BUBBIE /)('/-') TINrC SYJNL.1MND 1101E
IX FJOSlY10 m•NS TINHSFOIJNEA
(�) MNBER a:RFJ15 IMS 6 9NPE RFDUEST rTR Ppepi Cal%Hr r0 CIFAe UP uip
SECalawr POe4A GBU:S NO/aI IOP a' a BLm
RSEA CNYES 50 R fi19F CNI BE
•nlriRn Rlnlwr vnuTelc nc w'RUJ:
TWN 2S
SEC 11 COMCAST DIAL w.0.: 47894
1947 CLAXTER RD NE RNG 1 W
ND UTILITIES SALEM,OR SPAN REPLACEMENT SHT 2
PH: 971.600.0601 CALL LOCATE
FAX:971.275.1852 DRN:DET 14635 SW 88th AVE BEFORE YOU
nxutiiities.com SCALE: NONE DATE. 2/16/2016 TIGARD, OR. DIG OF 4
REPLACE WITH MIN.
GENERAL NOTES: NATIVE TOPSOIL..
RESTORE TO EXISTING 6" MIN. DEPTH OF 1"
1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING. CONDITIONS OR BETTER. DIA. CRUSHED ROCK
2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTIUTY PIPES OR STRUCTURES
SHOWN ON THESE PIANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE .. �
AVAILABLE CITY OR COUNTY RECORDS.SINCE THE ACTUAL LOCATION AND NATURE OF THE ;t.�.:-:}-
UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN,THE MAINTAIN 95%
CONTRACTOR Is REQUIRED TO VERIFY PRIOR TO EXCAVATION. MAINTAIN 95% 'v COMPACTION OR
3. THE RICHE-0F-WAY SHOWN HAS NOT BEEN SURVEYED OR nm.RIGHT-0COMPACTION OR RIGHT-OF-WAY GREATER & BACKFILL GREATER & BACKFILL
LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIAL CONTRACTOR PER JURISDICTIONAL
TO VERIFY ALL RIGHTS-OF-WAY AND/OR EASEMENTS PRIOR To CONSTRUCTION. PER JURISDICTIONAL STANDARDS AND
STANDARDS AND rT SPECIFICATIONS n
4. FOR LINDERCIROUND ACTNTIY:TEST AND VENTILATE MMIHOLE/UTILNY VAULT PRIOR TO SPECIFICATIONS
ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REWIRED,AND USE EYE
AND HEAD SAFETY PROTECTION PER FEDERAL.STATE.AND LOCAL REGULATIONS.
5. ALL EXCAVATION,TRENCHING,AND SHORING IS TO ADHERE TO THE CODE OF FEDERAL PROPOSED PROPOSED
RFGIUTONS TCFRT 1926.650 c_URPART P. SDR-11 SDR-11
a. PROVIDE ALL PTI5 WITH 1'.1'SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN
INGRESS/EGRESS.
b: �LAADDEE ALL OPEN SPO PITS AND TOREN—CMwGGFFOR2PUBLICFROM
SAFETY.OALLLBARRICAADES� 4" MIN. BEDDING 4" MIN. BEDDING
MUST BE EQUIPPED WITH FASHING LIGHTS FOR NIGHT VISIBILITY.
d. FOR PITS GREATER THAN 4'IN DEPTH,USE APPROPRIATE SHORING FOR WALL
STABILITY. TYPICAL TRENCH DETAIL TYPICAL TRENCH DETAIL
6. TRENCH COVER IS 70 BE 36•MINIMUM AND FREE OF ROCKS.DEBRIS,AND CLODS. UNIMPROVED AREAS GRAVEL STREETS
THE TRENCH IS TO BE A MINIMUM OF 36'COVER IN DEVELOPED ARES AND A MINIMUM OF
48'OF COVER IN UNDEVELOPED MEAS(ANY VARIANCE FROM THESE STANDARDS WILL BE NTS NTS
SPECIFIED ON THE PLANS).
7. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED.DISTURBED.OR DAMAGED/S A
RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER IN
ACCORDANCE WITH JURISDICTIONAL AGENCY STANDARDS AND SPECIFICATIONS.
SAWCUT EACH SIDE OF TRENCH
8. NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING. WIDTH OF TRENCH - SAWCUT WIDTH
9. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED. REPLACE ASPHALT CONCRETE 6" 12" 6" 12" OR LESS 6" MIN.
PER JURISDICTIONAL GREATER THAN 12" 12" MIN.
10. BOND BURIED/AERIAL FACILITES AS REQUIRED BY JURISDICTIONAL AGENCY(S). STANDARDS AND
SPECIFICATIONS. 3" MIN.
11. AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE AND
LOCAL REGULATIONS.
12. ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH APPROVED
WARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR MAINTAIN 95%
PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.IF REQUIRED.A
TRAFFIC CONTROL PUN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY. COMPACTION OR
PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN GREATER & BACKFILL
ADVANCE OF CONSTRUCTION ACTIVITIES. PER JURISDICTIONAL
13. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SWILL BE MAINTAINED AT ALL STANDARDS AND
nMES.AS NECESSARY,TEMPORARY PEDESTRIAN CROSSWALKS AND WAUGNG MEAS SHALL SPECIFICATIONS R7
BE PROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC
WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.
14. THE FOLLOWING FOOTAGE ME ESTIMATES.FOOTAGES TO BE VERIFIED PRIOR TO PROPOSED
CONSTRUCTION. SDR-11
4" MIN. BEDDING
taL TYPICAL TRENCH DETAIL
CONTRACTOR OR HIS AGENTS SHALL NOT ENTER OR ENCROACH UPON PRIVATE PROPERTY ASPHALT SURFACE
WRHOUT NOTIFYING THE PROPERTY OWNER A MINIMUM OF 72-HOURS IN ADVANCE OF
TIME OF PHYSICAL VISIT. IN
HANGER RSHALL NOTIFY PROPBY DOOR HANGER ERTY OWNER OF THE F OWNER IS NOT PRESENT AT NTS
CONTRACTOR'S
NAME,PHONE NUMBER,AND NATURE OF ENCROACHMENT AND WORK TO BE
PERFORMED
FDATE
S DIAL w.0.: 47894
1 COMCAST
1947 CLAXTER RD NE W 811 A
N� UTILITIES SALEM,OR SPAN REPLACEMENT CALL LOCATE SHT 3
PH: 971.600.0601
FAX:971.276.1862 14635 SW 88th AVE BEFORE YOU
ET TIGARD, OR. DIG OF 4
nxutllitle9.com SCALE: NONE 2�16/2016
EX CATV PED
I I I
4'x4' BORE PIT
I I I
14605
I I I
w
4635
Cy) I 00
00 4'x4' BORE PIT 00
' � — — — — I — — EX CAN PED I�
4'x4' BORE PIT
14665
a16
n 32
I 1I
I I
I
SW PINEBROOK DR EEL:
X CATV PED — — — _—
4'x4' BORE PR
8840 rff 8810 °
TWN:2S
SEC: 11 COMCAST DIAL W.0.: 47894
1847 CLAXTER RD NE �t RNG 1W
UTILITIES PHA�EM,OR1-600 G01 SPAN REPLACEMENT CALLLO�1 SHT 4
D FAX:871.276.1862 20 ° 40 14635 SW 88th AVE
BEFORE 1 DRN: DET ODRG YOU OF 4
nxu0lklea.com
SCALE:1"=40' DATE: 2/16/2016 TIGARD, OR.