Report (23) Dan Nelson From: Roger Brockway <roger@esigc.com> Sent: Tuesday, March 29, 2016 9:07 AM To: Dan Nelson Cc: Branden Taggart Subject: FW: Scan Data from XC-A08EEE Attachments: img-329080151-0001.pdf March 29, 2016 Building Permit#BUP 2015-00112/JIBC Dan Nelson: Dan Good morning: Attached is the information from American Buildings Company/engine and Gary Lewis(foundation engineer) required for us to move the std.X bracing which is currently located between grid lines E and D to between lines E and F of grid line 1 (north elevation) or our pre-engineered metal building. As you know this is a common (in the field type of modification) when there is a conflict with a personnel door or window location. We have contacted Carlson Testing to perform their inspections of the welds for the new connection plate to the building column at line F and the relocation of the anchor shoe to the concrete, when completed. Please call me on my cell if you have any questions,or you can call Gary Lewis on his cell phone 503-805-5586. He is currently working from home recuperating from open heart surgery. SPECIAL. fir, w£�? P'`` yURED State of O, ,r u cru a1 Sp ci y Code Thanks very much for your h Respectfully, 1: CeD1(2- ❑ Concrete and Reinforcing Steel City of Tigard A : ,•,, Pians olts Installed in Concrete B r%,►�F,� �� 0 Special Moment-Resisting Concrete Frame Roger Brockway Date President eib 0 ❑ Reinforcing Steel&Prestressing Steel Tendons ESI Construction and Suppl Me Structural Welding 10875 SW Herman Road VISIO ❑ High-Strenght Bolting Tualatin OR 97062-0833 503-968-3118 Office Structural Masonry 503-968-6639 Fax OFFICE COPY ❑ Reinforced Gypsum Concrete 503-341-1888 Cell ❑ Insulating Concrete Fill www.esiconstruction.net ❑ Spray Applied Fire-Resistive Materials ❑ Pipings, Driled Piers and Caissons Original Message ❑ Shotcrete From: WorkCentre 7120 [mailto:Scans@nwghelpdesk.com] Sent: Tuesday, March 29, 2016 8:02 AM ❑ Special Grading, Excavation and Filling To: Roger Brockway<roger@esigc.com> ❑ Smoke-Control Systems Subject: Scan Data from XC-A08EEE ❑ Other Inspections ESI Construction Inc. Office Phone: 503-968-3118 Office Fax: 503-968-6639 1 r, V AMERICAN BUILDINGS A r11-11=MR COMPANY 2260 Tenaya Dr. Modesto,CA 95354 (209)236-0580 Fax: (209)236-0588 March 21, 2016 ABC Job No.: W15G0032 Project Name: 8500 SW Spruce, Tigard, OR Mr. Brockway The following are response to your request dated 3/18/2016. Per attached page 2,we checked the new brace location attaching to column at grid F the column strength is not affected. Note that the revised foundation check with the new brace location is not by ABC. _coo PROft.e Arturo Magana, P.E. 40 �dtN '4 �� Q• 90 PE 7,p>, ,yOREU�ON y V. ,Y1620 J? 490 MAG PNP 3/21 EXPIRES:12/31/(t'v - . I .;T:;-....--::..;:•.-.., . • !...%,. „, - ,,,--,:.---n..-77,;,.:;,:::.• -i ; "•-:; ——:.--,*777:17-",,.7.7—,,,=•••••_...7.7.-7: .-•._ —:-.- .•-•;•-,:,,,,•-•i-- •-••••!.. .- ---7--.'t------— . _.:Is--ii 41..•!,Z.:la-2.. ";,:. ..":--"..11:-:••.- _L..... '1.71..L.!"...7;_'?';.:?:_:.:::.: 2.CP.-I; -- ' I ; 1 -.;›:I 1 r.,:: -.; I ..:::,.1:-.2 •.= , -•!- ! - 1 . :':!:....,I 1 r.-.. , --- j. . - 1 !:1:-.1,-.• .2 1 1 c.17.:1.7.1 1 7-, ' .. --- . I j- --1- E:..:;:;=-:! :_' . -•'. i...11:1. --Tn.-. '', ---;.; 1 1.-,:.•-• : 7.. ; 7:-?-,....: -,-- • .:"..r..., .,:'-'. ! ' . "-0... I ',-t I t•,::-7 1 i".•:: . ....!........- i , .5-7'..f.r.rt 1 i:.. I • ' -- .,,....", 1 1 : 1 I , . . .,.. ":1.::,.. F7:7' -: . - I,,,-..-7 i . • . .. : . . i.s...L.:1 i = i 1 ..14.-.,:_.I .,.. 1 -...‘- .' - - . ,-z-,',..'"-2,'''''•-'`': l'eri.LON: !i..".-:'..M I I 7.:71.1.-,e .:_--,; I --... • !:-:, j I 5:rt 7:1-.7_,PG-1.16:1147 1 11. 1._.1,E,!.F.:•1 1 1.11:::1:..1 :.:-:'1 jj. T.- ,__ 1..4%.!_lm:,%.,m i..c.1:.•L(74- . 1-' !-a; C--g2: I .......-• — I ..i.4-. "7-- •,. I id:- ... I ,It.r...1 • - 1 ...:::.!! • I t . 1 i 1 cr.i- :......." t.t,s-., ,7.,..1:...'e-. 1 0,2 r-•,..,.1,-4141-, I 1.-,1 o- - --,---:, 1;Xii:7:.:!': -:: 2 1%,44..F7-2-0.2-.: 1.1_1:111-,1.. `,.7-4-,,,... ,...-j,0.-,-.3v“! 4 . -. - -' 7 L ...o.1 , z ;" ; - , s: 1 i.•7.1 'la - I _ .J.I_ :. _ 1 I I ..._ ---7 i I j •-.. I I.' „___ s.z I 1 '. t •". 11 I3 1 ,:. I ,; 7 _.!. 1- .1- - 11 __ I I 1 t I .- FI l'3 I 1 -- - .' - 1 1 I ! 1.-1,7,-2 1 ::..-^M.11::: - I --c 1 ! -11 _1 :•-.-q ---...i I _4 1 ' r- ,, -] ,,, ! _ ,..-.. r i E ..... ',. —,-...- 1 ii 1 1;P-r 1• 1 1 ,, L..±.).-,-..-;-.1.,.-.1...,:•„_.„..„...,,,H?,-, - • ..-.:•!.1.11-"Z . r '-jji. 1,4 ' •'- '...7='-' i ! I I I , 1 I I 1:ex.111.-K.,- 7:: : lr- ..„.:, , ----,,---, —_, ••t .,.' ,ta• 1 h - I, 7 ... III '-. 1 - I 1 1 . _. I ,• _, I ! I, . . I ! - 1 1j. - • 1 -1: I 1 I. • 1 .. ii, ..-":1:EL-_-.. r1'1 1-, I 6 , . ft: r''4 ill . .-:....... .e... -------13J-R ! I ,,..• • I 1 •:.. , 1;-12. - --, - .....--------. 6- ____----r.f-----------7-- 1 ____• .1 '- ,-... + 1 . ,,,---- --------- . ---.----7-------7,-----, „,... , . ! ! t • ..---"- ---1, C.. 'I . 1 2.11: '7 (7,-, •;.-: ,...,.. . . ••1. . :,-------- . .s.-. ......, , ,z,..,.,...s i.i7.1.;..3,..i..1.3.- ,.....i..:11'_•::::.!,-,..2v,:'‘J..:4.--3..i...,.-.• -*, -%:'",74.--N,...__-) '; / , 1, c, 1 ..._ ,: -.,.:1- :::_.•:-.172..-r--s t 5,,..14.ta.b---",-:z-s.,... ,_,,.:., ...!,-..-_,-. It ,,,,.....,•: ; 1 .., , .... . • . . - - : .. . . , . • 11 ! -\-,-•,.''___ ,., --07 ,. . •••,--.--.--..•-•.-••' •:.%—— __. _ ___ .. _ , l'•':,.. . i "... - - ii" . . . : .i. , • ••,,,,, /,. . . . •-ss., . . ' , . . , i . I . ."-,.., P, , . , ! / , 1 • , ' •„..7 .. 1 .? _ *•,•-• - ----- - - ,.: • •.--...._-_. - !-•• 79- ,:i..,,.. , : • ; : i, ..i I•,. ', - — '!",,,,!• ri . , .., _ ,,.. ... -) \\....., •. e.9 i f-. --._ .— - o.-•-' . — ,-. -.------ , . . - • 1 . -...'".'--:7111)TWur — ' -7----.7-7'---- ' — - . . ._ — 1 _ . I i . .. _ _. . _.• - .. . l'' -, - • . , . __ - - - ---- ,..,,- .s--;,.',.„ . • - __ • •____. ___, _. , us,:,.• 6148 !pi i III (ToG' 87," do 6"znv A 7 CYZfg-_,7 sy /f t;1liji pi..r.,..„ 7 ....0'6)1) t-. ,.-- (.)4 . 10 - ,,,7111 '1a (q iq *VI Pi e !'! • ' K , ,,,,,,--, .,t, i,s----- G.f.;4 el -:::-:!. ,-- Irt.4 - , -,, \., „...„„pi,r(.1 --t.,..z•Q.,. .- 1 ,e• ,..,..0 a . „,---- , . . . Standard Welds Weld Details for Rod Brace to Angle BRACING WELD ROD BWR 110111111 I'��I� N. 6" BRACING CONNECTOR CLIP BCC AB5—G4 r' For Rods =3/4" to 1 1/2" 3" For Rods = 5/8" * 3" *Add 1/4" reinforcing fillet per AB4—F1 U U • Weld Details for Rod Brace to Flat Bar BRACING WELD ROD BWR ED- 111,111111.1=- - 6" BRACING CONNECTOR PLATE BCP AB5—G5 Rod For Rods = 3/4" to 1 1/2" N 3" For Rods = 5/8" * 3" *Add 1/4" reinforcing fillet per AB4—F1 v' Revised July 23, 2012 Page 29 LEWIS & VAN VLEET principals chris c. van vleet, p.e. Bary j. lewis, p.e. TO: Roger Brockway/ESI FROM: Gary J. Lewis, S.E. DATE: March 28, 2016 R E: Japanese International Baptist Church Bracing location revision and attachment We have reviewed the proposed revision relocating the bracing from the D-E bay to the E-F bay at JIBC. The attachment to the Grid E column was designed by the building engineer, and is acceptable to us as designed. The attachment to the perimeter footing at grid E.5 has been designed by us,and calculations for the anchors are attached. Use(4)7/8" diameter A36 threaded rods in the existing bracing shoe,spaced 3"and 9" and embedded a minimum of 12" into the concrete.Attach using Simpson SET adhesive with special inspection. Since the brace cable still attaches to the column but on the opposite face,the uplift reaction at the column does not change and the original anchor bolts are adequate. The foundation reaction for the brace cable that goes to the footing is the same as previous location,and the continuous footing is adequate,with the continuous reinforcement providing breakout confinement at the anchors. Revision is acceptable for the concrete foundation.Gary J.Lewis,S.E. f. (t.\\cj PAOFF / l�I\ rA\/Q *psi JREG' ., • Of 1.4 f ?�, 3i f it11ES EXPIRES 12-31-2016 CONSULTING ENGINEERS 1 8660 S.W. BOONES FERRY ROAD TUALATIN, OREGON 97062 (503) 885-8605 PHONE (503) 885-1 206 FAX Signature Certificate g Rl htSl nature g Document Reference: 'l r. Easy Online Document Signing Gary Lewis Party ID PS4XCTIVSIRX9BUEXNRM53 IP Address 98 246 164.14 �..�/�,'� t:l gjle I is d?lvvi coal �/ rim;;rr;iin!C a, k ab4e8f8032bead863c4c8a016bc8a7c596e04703 'III�jN■uLto ni` gR{y„S tl III Timestamp Audit All parties have signed document. Signed copies sent to:Gary Lewis and Gary J Lewis. Document signed by Gary Lewis(gjlewis@lvvi.com)with drawn signature.- 166.176.186.71 Document viewed by Gary Lewis(gjlewis@Ivvi.corn).-98.246.164.14 Document created by Gary J Lewis(gjlew s@lvvi.com).-98.246.164.14 • This signalllre page pr ovitids 1 record c;f i fi °n'ine �� � d(_tivlty execdtjng thi :onlydct, Page 1 of 1 SIMPSON Anchor DesignerT" Company: Lewis&Van Vleet,Inc. Date: 3/28/2016 Ergineer: GJL Page: 1/4 • Software Project: JIBC Ston.I.ie Version 2.0.5090.42 Address: 18660 SW Boones Ferry Road,Tualatin,OR Phone: 503-885-8605 E-mail: 1.Proiect information Customer company: ESI Project description:Bracing anchorage Customer contact name:Roger Brockway Location:Tigard,OR Customer e-mail: Fastening description:7/8"bracing anchors with SET Comment: 2.Input Data&Anchor Parameters General Base Material Design method:ACI 318-08 Concrete:Normal-weight Units:Imperial units Concrete thickness,h(inch):24.00 State:Cracked Anchor Information: Compressive strength,T<(psi):3500 Anchor type:Bonded anchor 4'C.v. 1.0 Material:F1554 Grade 36 Reinforcement condition: B tension,B shear Diameter(inch):0.875 Supplemental reinforcement:Not applicable Effective Embedment depth,her(inch):12.000 Do not evaluate concrbreakout in tension:Yes Code report:ICC-ES ESR-2508 Do not evaluate concreteete breakout in shear:Yes Anchor category:- Hole condition:Dry concrete Anchor ductility:Yes Inspection:Periodic h,<(inch):16.38 Temperature range:1 c„(inch):22.68 Ignore 6do requirement:Not applicable C,;"(inch):1.75 Build-up grout pad:No S,,„"(inch):3.00 Base Plate Length x Width x Thickness(inch):12.00 x 6.00 x 0.50 Load and Geometry Z Load factor source: ACI 318 Section 9.2 Load combination: not set Seismic design:Yes 33606 Anchors subjected to sustained tension: No , Strength reduction factor for brittle failure,0, 04 Apply entire shear load at front row: No '�f PPy � �3..; Anchors only resisting wind and/or seismic l0 1 x fi zi <Figure 1> 4 ss '' � '' oIb '',� i},..•"` } '�fi �rr Oft-Ib '142: '''!:4!&4 * `1:1,44't' $,y f :1,44{ > ' fin." y '.. j 11; �\EQ PAOf4cs S� 1N iZI1��� Q 15,099 #Y .a ti OREGON ,� 7.'Fp. i1 rl • :3. lam. Jr1 NI ES EXPIRES 12-31-2016 • Input dots and results must be checked for agreement with the existing circumstances,the stondord:and guidaelincs must he checked nor plausibility. 5956 W.Las Pestles Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtic.com SIMPSON Anchor Designer TM Company. Lewis&Van Vleet, Inc. Date: 3/28/2016 Engineer: GJL Page: 214 strmt'tT a Software Project: JIBC Version 2.0 5090.42 Address: 18660 SW Boones Ferry Road,Tualatin,OR Phone: 503-885-865 E-mail: Figure 2> ^ �* `"t» ;� ' lilt':-, t, ' I:31 0 N 12.00 - 12.00 Recommended Anchor Anchor Name:SET-XP® SET-XP w/7/8"0 F1554 Gr.36 Code Report Listing:ICC-ES ESR-2508 k ,:}.rpt 1 i 1 I. 1 1 • i 1 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. ,Strong-h 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 vrnw.strongtic.com 1 SIMPSON Anchor Designer TM Company: Lewis&Van Vlect,Inc. Date: 3/28/2016 Engineer: GJL Page: 3/4 Strong-Tie Software Project: JIBC Version 2.0 5090.42 Address: 18660 SW Boones Ferry Road,Tualatin,OR e Phone: 503-885-8605 E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, N„0(Ib) V,O,(Ib) Vu,y(Ib) v(V„0.)2+(V,,2y)z(Ib) 1 840.0 920.0 0 0 920.0 2 B40.0 920.0 0.0 920.0 3 840.0 920.0 0.0 920.0 4 840.0 920.0 0.0 920.0 Sum 3360.0 3680.0 0.0 3680.0 Maximum concrete compression strain(16):0.00 <Figure 3> Maximum concrete compression stress(psi):0 01 02 Resultant tension force(Ib):0 Resultant compression force(Ib):0 Eccentricity of resultant tension forces in x-axis,a N,(inch):0.00 Eccentricity of resultant tension forces in y axis,e'Ny(inch):0.00 ,/ Eccentricity of resultant shear forces in x-axis,e'v,(inch):0.00 Um- Eccentricity cf resultant shear forces in y-axis,e'vy(inch):0.00 x'Ilr 04 03 4.Steel Strength of Anchor in Tension(Sec.D.5.1) N.(lb) 4 ON.(lb) 26795 0.75 20096 6.Adhesive Strength of Anchor in Tension(AC308 Sec.3.3) Tkcr= TkcrfsM1on-ta,mKsataN.3ea Th..,(psi) fsrwn-rem, Km aN,m Tko,(psi) 700 1.00 1.0D 0.80 560 Nao=rk.nrdAI(Eq.D-16f) rkc,(psi) da(in) her(in) Nao(Ib) 560 0.88 12.000 18473 0.750 4Na9=0.75404(ANa/ANao)y'ed,NaY'gNaY'0c,N0Y'o,NaNao(Sec.D.3.3.3,D.4.1 &Eq.D-16b) AN,(in`) ANao(int) '!'edN, YQN, Y'cc,Na '4,N, N0o(Ib) 4 0.754o4Nx. (lb) 621.77 365.39 1.000 1.274 1.000 1.000 18473 0.55 6605 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. tan,.,,- .t :1' „i 1r .,nn-,y i' 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax 925.847.3871 www.strongtie.com SIMPSON Anchor Designer TM Company: Lewis&Van Vlect,Inc. Date: 3/28/2016 Engineer: GJL Page: 4/4 Stro�rlle Software �e Project: JIBC Version 2.0.5090.42 Address: 18660 SW Boones Ferry Road,Tualatin,OR e Phone: 503-885-8605 E-mail: 8.Steel Strength of Anchor in Shear(Sec.D.6,1) Vs.(lb) cq,o„r 0 tAsets iv,ouf(AV sews 0V„(Ib) 16080 1.0 0.65 0.68 7107 10.Concrete Prvout Strength of Anchor in Shear(Sec.D.6.3) 0.75ytvOVcpq=0.75s6aqiminika,N,g;krpNcbg =0.7500 m nIk,(An./Ae oJ'/ed,Nx l'.Na Pee N,Vp,N,Nao;km(Arx/ANee)TecN'Fed NY'c,N`/'cP,NNb (Eq. D-30b) kq, AN.(in2) Ae&(in2) y'.drv, '/'e,Na i�.N, '/',Na N,o(Ib) Na(Ib) 2.0 621.77 365.39 1.000 1.311 1.000 1.000 18473 41197 Ark(int) Awe.(in2) l...N 'FON '/c,N I,F,N Nt(Ib) Net(Ib) ¢ 891.00 576.00 1.000 1.000 1.000 1.000 19233 29752 0.70 0.7540V, (Ib) 12496 11.Interaction of Tensile and Shear Forces(Sec.D.7) Tension Factored Load,N.(ib) Design Strength,mN.(lb) Ratio Status Steel 840 20096 0.04 Pass Adhesive 3360 6605 0.51 Pass(Governs) Shear Factored Load,V.(Ib) Design Strength,aVn(ib) Ratio Status Steel 920 7107 0.13 Pass Pryout 3680 12496 0.29 Pass(Governs) Interaction check N./ON„ Vva/014 Combined Ratio Permissible Status Sec.D.7.3 0.51 0.29 80.3% 1.2 Pass SET-XP w17/8"(2)F1554 Gr.36 with hef=12.000 inch meets the selected design criteria. 12.Warnings -Concrete compressive strength used in concrete breakout strength in tension,adhesive strength in tension and concrete pryout strength in shear for SET-XP adhesive anchor is limit to 2,500 psi per ICC-ES ESR-2508 Section 5.3. -Concrete breakout strength in tension has not been evaluated against applied tension load(s)per designer option.Refer to ACI 318 Section D.4.2.1 for conditions where calculations of the concrete breakout strength may not be required. -Concrete breakout strength in shear has not been evaluated against applied tension load(s)per designer option.Refer to ACI 318 Section D.4.2 1 for conditions where calculations of the concrete breakout strength may not be required. -Desigrer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. ti ern it, ,_ ,t,,;...!, Ili, 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 vvvvw.slrongtie.com This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. • Signature Certificate RightSignature Document Reference: i r Easy Online Document Signing Gary Lewis Party ID ZLUPVWIPF1383D3AZLESEY IP Address. 98 246 164.14 ve:of 1r1 E.r:Vt cern r�icril,I Fi j„ „int chr�F :.n, ab4e8f8032bead863c4c8a016be8a7e596e04703 1111 0,BIMPOMIN 6"i 11111 Timestamp Audit All parties have signed document. Signed copies sent to:Gary Lewis and Gary J Lewis. Document signed by Gary Lewis(gjlewis@Ivvi.com)with drawn signature.- 166.176.186.71 Document viewed by Gary Lewis(gjlewis@Ivvi.corn).-98.246.164.14 Document created by Gary J Lewis(gjlew.s@Ivvi.com).-98.246.164.14 • Eh. a i This signature page provides a record of the online ' � achvitv executing this ei_intract. Page 1 of 1