Report (22) /ylsriXisj°9/
r' � VW
GeoP Me
Engineering,Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel (503)598-8445
Investigation•Design•Construction Support Portland, Oregon 97224 Fax(503)941-9281
DAILY FIELD REPORT
PROJECT:Brittany Homes Misc.—6919 SW Oak Street DATE: March 16,2016
JOB#: 16-4164 WEATHER:
CLIENT:Brittany Homes CONTRACTOR: Brittany Homes
PERMIT NUMBER: PAGE#: 1 of 1
Inspection Notes: (Include location,testing data,substitutions/deviations,materials,and methods of construction,conformance statement,etc.)
TYPE OF OBSERVATION: Foundation Subgrade
GeoPacific geotechnical engineer Jim Imbrie on site to observe the preparation of foundation subgrade. I provided
recommendations to the earthwork subcontractor to excavate to stiff, native subgrade and place approximately 4 to 6
inches of 4"-0 crushed aggregate. A layer of%"-0 crushed aggregate will be placed over the 4"-0. Based on my
observations, foundation subgrade has been adequately prepared and is suitable for further construction.
DISTRIBUTION LIST: OBSERVED BY: James D. Imbrie
Jeff Luedloff(jeff@brittanyhomesinc.com)
GeoPacific Engineering, Inc.Signature
Information contained herin pertains to materials testednnspected only. The fact that any particular work has been observed or tested does not waive
the contractors responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information
contained herin should be considered preliminary until review by the project engineer.
'S
GeoP 11118
Engineering.Inc.
Real-World Geotechnical Solutions 14835 SW 72nd Avenue Tel(503)598-8445
Investigation•Design•Construction Support Portland,Oregon 97224 Fax(503)941-9281
DENSITY TEST DATA SHEET
PROJECT SOIL DESCRIPTION DATE
Brittney Homes Miscellaneous Baker Resources 3/21/2016
PROJECT NUMBER 3/4"-0 Crushed Rock WEATHER
16-4164 Partly Cloudy,55°F
CLIENT NUCLEAR GAUGE SERIAL# CONTRACTOR
Brittany Homes Inc. 67718 Brittney Homes
PERMIT NUMBER METHOD OF TEST PAGE#
Troxler Gauge,T-180/90% 1 of 1
TEST ELEV FIELD FIELD DENSITY MAX.DRY COMP. COMP. OPTIMUM PASS
TYPE TEST LOCATION (�) MOIST. (PCF) DENSITY SPEC, RESULT MOISTURE LAB ID OR
% WET DRY (PCF) % % % FAIL
SF 6919 SW Oak St. Footing Pad, FG 6.6 128.4 120.4 133.3 90 90.3 11.9 P15-171 P
NE Corner,3'W,20'S
SF 6919 SW Oak St. Footing Pad, FG 6.5 125.1 117.5 133.3 90 88.1 11.9 P15-171 F
NE Corner, 12'W,12'S
SF 6919 SW Oak St. Footing Pad, FG 6.6 130.3 122..2 133.3 90 91.7 11.9 P15-171 P
NE Corner, 12'W, 12'S RETEST
SF 6919 SW Oak St. Footing Pad, FG 7.2 129.3 120.6 133.3 90 90.5 11.9 P15-171 P
NE Corner,20'W,2'S
SF 6919 SW Oak St.Footing Pad, FG 7.8 134.7 124.9 133.3 90 93.7 11.9 P15-171 P
Far SW Corner, 10'E,3'N
SF 6919 SW Oak St. Footing Pad, FG 6.2 131.2 123.5 133.3 90 92.6 11.9 P15-171 P
Far SE Comer,2'W, 15'N
SF 6919 SW Oak St. Footing Pad, FG 6.5 131.5 123.4 133.3 90 92.6 11.9 P15-171 P
Far SE Corner, 10'W, 18'N
SF 6919 SW Oak St. Footing Pad, FG 5.9 128.6 121.4 133.3 90 91.1 11.9 P15-171 P
Far SE Corner,27' E,25'N
SF 6919 SW Oak St.Footing Pad, FG 6.4 133.1 125.1 133.3 90 93.9 11.9 P15-171 P
Far SE Corner,55'W,2' N
SF 6919 SW Oak St. Footing Pad, FG 6.9 128.5 120.2 133.3 90 90.2 11.9 P15-171 P
Far NW Corner,20' E,2.5'S
TEST TYPE: LF=Lot Fill SF=Structural Fill ST=Sanitary Trench DT=Storm Trench WT=Water Trench RF=Roadway Fill
RW=Retaining Wall Backfill PS=Pavement Subgrade BC=Base Course FT=Franchise Trench
REMARKS:
GeoPacific was onsite to conduct nuclear density testing of backfill in the area of the footing placement. 4" rock was
placed directly beneath the tested material, which was 3/4"crushed rock at approximately 7"thick.Test results met
project specifications for compaction at the locations tested.
TESTED BY:Adam Hessenkemper REVIEWED BY:
Information contained herein pertains to materials testedfinspected only. The fact that any particular work has been observed or tested does not waive the
contractor's responsibility for the means and methods of construction,job site safety,or to comply with the contract documents. This information