Report (14) 4u1 c)--Ulf , ex-1=03, /a Iq2 S&) Se ofs TRANS' Submittal : ` , AN 4 2016 Prepared For: Date: 7` it 1 01' 9 MAR American Heating December 22, 2015 r, Lita lilON Job Name: American Heating- Providence Scholls Ferry RTU-3 Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product Specification Section 1 Trane Voyager 2 Rooftop Replacement The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Matt O'Banion Trane 7257 SW Kable Lane Portland, OR 97224-7181 Phone: (503)620-8031 Fax: (503)639-1454 J:IJOBS1124159321121Submittal(Rev. 0).doc American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Tag Data-Packaed Gas/Electric Rooftop Units Qty: 1) Item Tag(s) Qty Description Model Number Al RTU-3 1 15 Ton Trane Voyager 2 Rooftop YSD180F4RLB--KHB000060004000000000000000 Product Data -Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 15 Ton DX Cooling w/Natural Gas Heat R-410a Refrigerant Standard Efficiency 460V/3 Electrical (No Disconnect) VAV Supply Fan w/VFD and Shaft Grounding 2-Stage Low Gas Heat Capacity I Low Leak Economizer w/Dry Bulb Controls 2" Filter Rack w/ 1 Set of MERV 8 Filters BACnet MS/TP Controls Interface Standard On/Off Power Exhaust(FId) Adapter Curb to Existing Trane BTC170G (FId) 1St Year Whole Unit Parts and Labor Warranty 2nd 5`h Year Compressor Parts Warranty Rooftop Notes: 1) Less(or by others): Installation, storage, rigging, seismic calculations/restraints, external vibration isolation, spares, conduit, power wire/wiring, disconnects, over current protection, gas piping and accessories, regulators, condensate piping and accessories, traps, air balance, start-up, owner training, commissioning, installation of field accessories(FId), and warranties not listed. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 3 of 12 Others t American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Performance Data -Packaged Gas/Electric Rooftop Units Tags RTU-3 Design Airflow(cfm) 6000 Cooling Entering Dry Bulb(F) 80.00 Cooling Entering Wet Bulb(F) 64.00 Ent Air Rel Humidity(%) 41.56 Ambient Temp(F) 95.00 Cooling Leaving Unit DB(F) 59.13 Cooling Leaving Unit WB (F) 54.69 Gross Total Capacity (MBh) 181.54 Gross Sensible Capacity(MBh) 153.21 Gross Latent Capacity(MBh) 28.33 Net Total Capacity(MBh) 166.25 Net Sensible Capacity(MBh) 137.92 Net Sensible Heat Ratio(Number) 0.83 Heating EAT(F) 60.00 Heating LAT(F) 91.18 Heating Temp Rise(F) 31.18 Output Htg Capacity(MBh) 203.00 Output Htg Capacity w/Fan(MBh) 218.29 Design ESP(in H2O) 1.500 Component SP Add(in H2O) 0.370 Field Supplied Drive Kit Required None Indoor Mtr. Operating Power(bhp) 4.85 Indoor RPM (rpm) 913 Indoor Motor Power(kVV) 3.62 Outdoor Motor Power(kW) 0.95 Compressor Power(kW) 13.78 System Power(kW) 18.35 IPLV @AHRI (IPLV) 13.2 MCA(A) 40.00 MOP (A) 50.00 Compressor 1 RLA(A) 15.40 Compressor 2 RLA(A) 9.60 Condenser Fan FLA(A) 1.60 Evaporator Fan FLA(A) 7.60 Evaporator Face Area(sq ft) 26.00 Evaporator Face Velocity(ft/min) 231 Evaporator Fin Spacing(Per Foot) 180 Evaporator Rows() 3 Min. Unit Operating Weight(Ib) 1818.0 Max Unit Operating Weight(Ib) 2240.0 Fan Motor Heat(MBh) 15.29 Evap Coil Leav Air Temp(DB) (F) 56.36 Evap Coil Leav Air Temp(WB) (F) 53.55 Rated capacity(AHRI) (MBh) 176.00 Exhaust fan power(kW) 0.56 Refrig charge(HFC-410A)-ckt 1 (lb) 11.4 Refrig charge(HFC-410A)-ckt 2 (Ib) 6.0 ASHRAE 90.1 Yes Saturated Suction Temp Circuit 1 (F) 49.09 Saturated Discharge Temp Circuit 1 (F) 120.13 Saturated Suction Temp Circuit 2 (F) 50.58 Saturated Discharge Temp Circuit 2(F) 118.15 IEER Rating () 13.20 EER @ AHRI Conditions(EER) 11.0 Total Static Pressure(in H2O) 1.870 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 4 of 12 Others 1 American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Mechanical Specifications-Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 General • The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A,and 100 percent run tested to check cooling operation,fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 8117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal,service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced,fire-resistant, permanent, odorless, glass fiber material.The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive, hermetic,scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors.All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. These are standard on all Voyager models. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter driers factory installed as standard.An area shall be provided for replacement suction driers. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components.A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation,a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow. On an initial call for heat,the combustion blower shall purge the heat exchanger 45 seconds before ignition.After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane(field installed kit) and shall also comply with California requirements for low NOx emissions. The 12%-25 tons shall have two stage heating (Gas/Electric Only). Microchannel coils The microchannel type condenser coil is standard for the T/YCD 12.5-25 ton standard efficiency models. • Due to flat streamlined tubes with small ports,and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume,which leads to better compressor reliability.Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re-cyclability.Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition,flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity.The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 5 of 12 Others American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves.All motors shall be thermally protected. Oversized motors shall be available for high static application.All indoor fan motors meet the U.S. Energy Policy Act of 1992(EPACT). Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort.A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Low Leak Economizer This accessory meets low leak requirements for ASHRAE90.1, IECC, and Title 24 standards;Allows 100 percent outdoor air supply from 0-100 percent modulating dampers; Comes standard with Barometric Relief; can be paired with Powered exhaust for additional building evacuation; Can be paired with Fault Detection(FDD)to meet current mandatory Title 24 requirements; Dry Bulb; And, available for down flow applications. Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit,the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the discharge line cools down,the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. Two-Inch Pleated Filters Two inch pleated media filters shall be available on all models. BACnet Communications The BACnet communications interface allows the unit to communicate directly with a generic open protocol BACnet MS/TP Network Building Automation System Controls. Differential Pressure Switches These options allow for individual fan failure and dirty filter indication.The fan failure switch will disable all unit functions and"flash"the Service LED on the zone sensor.The dirty filter switch will light the Service LED on the zone sensor and will allow continued unit operation. Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These indications will be registered with either a zone sensor with status indication lights or an Integrated Comfort System. Accessory-Powered Exhaust The powered exhaust shall provide exhaust of return air,when using an economizer, to maintain better building pressurization. VAV Operation The VFD shall receive a 0-10 Vdc signal from the unit controls based upon supply static pressure and shall cause the drive to accelerate or decelerate as required to maintain the supply static pressure setpoint. When subjected to high ambient return conditions the VFD shall reduce its output frequency to maintain operation. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 6 of 12 Others r American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Unit Dimensions -Packaged Gas/Electric Rooftop Units Item:Al Qty: 1 Tag(s): RTU-3 NOTES: 2.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS.(SELECTED OPTION:SEE ACCESSORY SHEET) • 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 1111 6 1a/1s' DOWNFLOWCONDENSATE DRAIN CONN 1"NPT I'41,1111 I �� 64 11116" 1 44,4 GAS CONNECTION(SEE NOTE 1) 121 11/16" 11/16" 32 9 15/16" II 7/6"DIA.HOLE (UNIT CONTROL WIRE) 211/16" -• \16' `2"DIA.HOLE (UNIT POWER WIRE) PACKAGED GAS/ELECTRIC-DOWNFLOW ISOMETRIC DRAWING 4 1/4" 19 15116' 28 3/4" 26 7/16"- 4 /16" '4 1/4" ^\ 68 11/16" 76 5/16" SUPPLY RETURN L— --J O PACKAGED GAS/ELECTRIC-DOWNFLOW PLAN VIEW DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 7 of 12 Others American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Unit Dimensions-Packaged Gas/Electric Rooftop Units Item:Al Qty: 1 Tag(s): RTU-3 • ELECTRICAL/GENERAL DATA • GENERAL PERFORMANCE Standard Motor (1)(3) Model(Ton): YSD180F(15.0) Minimum Circuit Ampacity: 38.0 Unit Operating Voltage Range: 414-506 Maximum Fuse Size: 50.0 Unit Primary Voltage: 460 Maximum(HACR)Circuit Breaker 50.0 Unit Secondary Voltage: - UnitHertz: 60 Oversized Motor (1)(41 Field Installed Oversized Motor (11(4) Unit Phase: 3 MCA: 40.0 MCA: N/A MFS: 50.0 MFS: N/A EER:15) 11.0 MCB(HACR): 50.0 MCB(HACR): N/A GAS HEATING COMPRESSOR Heating Models: Low Circuit(s) Heating and 1 Stage Input(Btu/h) 250,000/175,000 Number 2 Heating and 1 Stage Output(Btu/h): 203,000/142,000 Horsepower 3.60/4.75 Min./Max.Gas Input- Phase: 3 Pressure Natural or LP: 2.5/14.0 Rated Load Amps: 15.6/96 Gas Connection Pipe Size: 1/2" Locked Rotor Amps: 142.0/62.0 INDOOR MOTOR Oversized Motor (4) Field Installed Oversized Motor (4) Number (3) 1 Number: 1 Number N/A Horsepower. 3.00 Horsepower 5.00 Hp: N/A Motor Speed(RPM): 1,740 Motor Speed(RPM): 3,450 Motor Speed(RPM): N/A Phase: 3 Phase: 3 Phase: N/A Full Load Amps: 4.8 Full Load Amps: 7.6 FLA: N/A Locked Rotor Amps: 40.5 Locked Rotor Amps: 549 LRA: N/A OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Number 2 Horsepower: 0.75 (Gas-Fired Heating only) Horsepower 0.50 Motor Speed(RPM): 1,040 Motor speed(RPM): 1.100 Phase: 1 Horsepower 0.1 Full Load Amps: 3.2 Motor Speed(RPM): 3,500/2,800 Phase: 1 Locked Rotor Amps: 8.4 Phase: 1 Full Load Amps: 1.6Full Load Amps: 0.8 Locked Rotor Amps: 3.8 Locked Rotor Amps: 2.00 FILTER REFRIGERANT (2) Circuit#1/2 Type: Throwaway Type: Furnished: Yes R410 Factory Charge Number 4/4 Recommended See: 20"x20"x2"/20"x25"x2" Circuit#1/2: 11.4 Ib/6.0 Ib NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value incudes oversized motor. 4.Value does not include Power Exhaust Accessory. 5.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 8 of 12 Others Ai American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Weight, Clearance& Rigging Diagram-Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 CLEARANCE fiB" \/ (1727.2mm) i CLEARANCE 36" CLEARANCE FROM THE (914.4mm) TOP OF UNIT 72" (1828.8mm) i t P P �o Q CLEARANCE 60" �'� , (1524mm) P fie CLEARANCE 48„ (1219.2mm) a 0 \v\ DOWNFLOW-PACKAGED GAS/ELECTRIC CLEARANCE UNIT OUTLINE 40/0 \ ROOF OPENING \ 76 1/2" 81" \ i • DOWNFLOW-PACKAGED GAS/ELECTRIC ROOF OPENING CLEARANCE FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 9 of 12 Others American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Weight,Clearance& Rigging Diagram-Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 INSTALLED OPTIONS NET WEIGHT DATA • Accessory Accessory Economizer Motorized Outside Air Damper n Manual Outside air Damper .029 Manual Motor High Static Drive [(W1 Thru the Base Electrical WelifUnit Mounted Circuit Breaker Unit Mounted Disconnect // \\�� Power Exhaust 95.0 lb 1111���//ri.Al��lll Hinged Doors Zone Sensor LPG Conversion Kit �--r - -- -- Powered Convenience Outlet 0/21 Roof Curb CORNER WEIGHT BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET O © © © E F 2281.OIb 1822.OIb 618.01b 493.OIb 336.OIb 378.OIb 57" 33" NOTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT OF OPTION/ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3.NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. 5 WEIGHT ARE OF BASE UNIT ONLY.FOR TOTAL WEIGHT,10 DIGIT FACTORY INSTALLED • OPTION(ECONOMIZER AND/OR OVERSIZED MOTOR OR FIOP/ACCESSORY WEIGHT MUST BE ADDED. • Afr • • % � l o del o RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 10 of 12 Others American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Accessory-Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 0 " P- i &VA m ,„, \ ilk ViA 01 ttfr„p 4 / .14 rio w N0 z 0 0 W A } CL 0 w . ? \ U 0 Q O J LL z O 0 W z Q w a co co Lu a / i J W Z a 0 W 0 0 x • LU w N M 0 Z 0 " w FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 11 of 12 Others • j American Heating-Providence Scholls Ferry RTU-3 December 22,2015 Accessory- Packaged Gas/Electric Rooftop Units Item: Al Qty: 1 Tag(s): RTU-3 • r , ( tlicox , ,,,,„, -,..„,,,,, ,,____...---______ . END PLANEL \ o ECONOMIZER 9 HOOD • ::"; ✓p A. ✓ 1 /11,/ '.:-4,1/4,4,1111111111111111* DOWNFLOW ACCESSORY-POWER EXHAUST POWER EXHAUST ` I 39" — FROUNT OF POWER EXHAUST F FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 12 of 12 Others I 1 t • • • OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI YIASM-1152 REVISIONS MATERIAL: 14ga.GAL STEEL REV. DESCRIPTION DATE APPROVED 1"1-112LB DUCT INSULATION (R VALUE 3.85) Attn: Tag: 1 INITIAL DRAWING 5/7/09 00 GASKET PROVIDED WITH CURB 2 MADE CURB 20"TALLIWAS 2E1 3/3/10 MWG 1 1/2"ADDED TO EXISTING CURB O.D. 3 UPDATE TO 14GA 21/2013 HMH Approval: RETURN AIR 77 7/8" - �'� - 49 5116" y 24 1/16" J 1 `/` SUPPLY AIR ISINtow EXISTING CURB LAYOUT - JP 1, 4e00 71 5/i6" 1 76 1/4" F. 2„4 • t • • • • •- — 2" 603!4" VERTAI4X 58 1 / \ RETURN SUPPLYI 1 • I I 2 1/4"— y 16 3/4" 116 7/8" --� 17 3/4" f 32 13/16"— r - 80 5!8" II 20" II II 3 •. 77 3/4" -11 3 L. 62 1/4" 1 1 CURB WEIGHT ILBS.I APPROVALS DATE MU 1-3665-3020 CURB SHOWN IS CDI STANDARD CONFIGURATION 250.08 wE<..;jpetere CDI RESERVES THE RIGHT TO CHANGE LAYOUT ---- Monday,October 24,2011425:18 PM QUOTE#: WITHOUT NOTIFICATION.IF CURB IS NEEDED IN A 'VERIFY EXISTING CURB OD 17660 TYLER ST NW ORAWOMO MO DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED 'VERIFY SUPPLY AND RETURN OPENINGS "'"' CDI ELKRIVER,MN55330 1-3665-3020 PRIOR TO PLACING AN ORDER. NOTEANrcHANGes rw _ 'CALL WITH ANY QUESTIONS (763)391.7790 'FAX BACK IF DRAWING IS OK AS IS m..1..I••• 4.5 (763)391.7661 {EAU 1 25 I SWEET 1 or 2