Plans (14)
ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES _ A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A r ,41 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. FEB 2 5 ZO16 ` CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CITY OF TIGARD EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. BUILDING DIVISION (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, CITY OF TIGARD FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE REVIEWED FOR CODE COMPLIANCE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE Approved: [ Ilj • GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY OTC: [ HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Permit#: Prs1-2C(G-- oc ▪ Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Address: Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Suite #: �/I 1(;7,kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC By: Date: LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OFFICE COPY OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET C!) PV2 SITE PLAN '' , PV3 STRUCTURAL VIEWS _ PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES :� PV5 THREE LINE DIAGRAM Cutsheets Attached OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC W RGC, CGC1 AND 2012 IBC. { 2. ALL ELECTRICAL WORK SHALL COMPLY WITH 0 THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON ELECTRICAL SPECIALTY CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Tigard REV BY DATE COMMENTS MI11=1 DATE COMMENTS ©©© UTILITY: Portland General Electric 40"" I * CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-97231 9 5 00 OIMER � • CONTAINED SHALL NOT BE USED FOR THE PHILLIPS, KENNETH E. PHILLIPS RESIDENCE Ian Wilson 14s" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: -P-i‘SolarCit NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8400 SOUTHWEST NORFOLK COURT 2.86 KW PV ARRAY i� y PART TO OTHERS OUTSIDE THE RECIPIENT'S MIMES: TIGARD OR 97224 3055 a Way ORGANIZATION, EXCEPT IN CONNECTION WITH s THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZSCI,Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN SHEET: REV: DATE T:(650)638-1028 F:(650)638-1029 PERMISSION OF soLARaTY INC. PAGE NAAE (971) 777-9659 SOLAREDGE , SE3000A—US—ZB—U COVER SHEET PV 1 1/27/2016 (888)-sol-alr(765-2489)n.a.eoiercity.com PITCH: 24 ARRAY PITCH:24 MP2 AZIMUTH:270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 36 ARRAY PITCH:36 8400 Southwest Norfolk Court MP3 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories (E)DRIVEWAY Front Of House 0 1, D ,' , AC LEGEND ® U Q (E) UTILITY METER & WARNING LABEL 12' P B JD O In Cl ® ® ® 0® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS 3 O • - O 0I DC °UnloHceO Gated° P3 {-.-•-1 DC DISCONNECT & WARNING LABELS I a o t} Q O t F9 AC DISCONNECT & WARNING LABELS • ee .0 0 0 N ; 0 DC JUNCTION/COMBINER BOX & LABELS ° lonlockod Gated O o ji W O PIhA D DISTRIBUTION PANEL & LABELS 23 C, O El NLc 0 LOAD CENTER & WARNING LABELS 6 = ❑ O DEDICATED PV SYSTEM METER I 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r,=-i l% `I INTERIOR EQUIPMENT IS DASHED L_'J SITE PLAN N TOTAL ARRAY AREA (SF): 199 Scale: 3/32" = 1' 1111TOTAL ROOF AREA (SF): 1804 w `r E TOTAL ARRAY AREA IS a 11.05 01' 10' 21' PERCENT OF TOTAL ROOF AREA I'I—� s CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-9723195 0 0 PREMISE OWNER: DESCRIPTION: DESIGN CONTAINED SHALL NOT BE USED FOR THE PHILLIPS, KENNETH E. PHILLIPS RESIDENCE Ian Wilson `f sSoiarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: •�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8400 SOUTHWEST NORFOLK COURT 2.86 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS OR 97224 3055 CleaNew Way ORGANIZATION, EXCEPT IN CONNECTION YAM MODULES: THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZSan CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERIER: PAGE NAME: SHEET: REV: DATE T:(650)638-1028, F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3000A-US-ZB-U (971) 777-9659 SITE PLAN PV 2 1/27/2016 (888)-sol-aTY(765-2489)www.soIarcity.com k \ (E) 2x4 ® / (E) 2x4 1:(d..................#._ .'i ' \ PRE—MANUFACTURED TRUSS ] PRE—MANUFACTURED TRUSS STRUCTURE MEETS THE - . —2 5'-4'' / 5'-8” / STRUCTURE MEETS THE • rillIk. 4'-6" PRESCRIPTIVE REQUIREMENTSOF THE OSSC SECTION 3111 (E) LBWPRESCRIPTIVE REQUIREMENTS 1 OF THE OSSC SECTION 3111 SIDE VIEW OF MP3 NTS SIDE VIEW OF MP2 NTS B MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" TOP CHORD 2x4 @ 24" OC ROOF AZI 180 PITCH 36 STORIES: 2 TOP CHORD 2x4 @ 24" OC ROOF AZI 270 PITCH 24 STORIES: 2 ARRAY AZI 180 PITCH 36 ARRAY AZI 270 PITCH 24 BOT CHORD 2x4 @24" OC Comp Shingle BOT CHORD 2x4 @24" OC Comp Shingle PREMISE OWNER: DESCPoPiION: DESIGN: CONFIDENTIAL— THE INFORMATION HERON JOB NUMBER: ���� ■ CONTAINED SHALL NOT BE USED FOR THE �B-9723195 00 PHILLIPS, KENNETH E. PHILLIPS RESIDENCE Ian Wilson �'�� SolarCity. • BENEFIT OF IITBE"D�DISCLOSED IN 'MIO E OR IN Moom sYSTok 8400 SOUTHWEST NORFOLK COURT 2.86 KW PV ARRAY ;P,' PART TO OTHERS OUTSIDE NE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 3055 CI�„fe„Way THE SALE AND USE OF NE RESPECTIVE (11) REC # REC260PEZ P NAME SHEEP: REV DATE San 5ateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC' SOLAREDGE # SE3000A—US—ZB—U (971) 777-9659 STRUCTURAL VIEWS PV 3 1/27/2016 (888)-sal-CRY(765-2489) wolorcIty. UPLIFT CALCULATIONS 01.27.2016 PV System Structural Version#53.6 SolarCU' 'I Design Software ProjectnformationTableVfTable its gry: II PVRisk SyCatest t oTYPe SolarCity Sleefd+foufit"' Comp Roof Comp Roof LatierS6f Comp Roofing 2 • Roof Slope 36° Rater Spino 24"D.C. PV System Module Orientation Landscape and Portrait PV Mothtle Area « 195 sf PV Module Width 39" PV Module Length 66" ,Standoff(Attachment Hardware) Comp Mount Type ItedOcnd GIxaun /Roof Ltve/Sricav Loads Ground Snow Load pg 25.0 psf ASCE Table 7-1 Surrounding Roof Snow 100% 25.0psf ASa Eq:7.4.1 Roof Snow Over PV Modules 100% 25.0 psf `ASCE Eq:7.4-1 Windsign Cilterta Wind Design Code ASCE 7-05 WincitXtsign Method ioar#ally/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure y C ' Section 6.5.6.3' Roof Style Gable Roof 'Ftg.6-118/C/o-14i s Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.8 sf IBC 1509.7.1 Wind _ re Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 To .is Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Import factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(VA2)(i) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6-118/Uo-14,Va Ext.Pressure Coefficient(iia) , GCp tn) , O.:a;. 8-11ef14A/a Design Wind Pressure p p=qh(GCp) Equation 6-22 Windure U per ` -17.6 ,.. Wind Pressure Down p(down) 16.2 psi , . #9t' laiiiice solacing*''. 'iE 1ir Max Allowable Standoff Spacing Landscape 72" 39" • Al ntiever LieicNcaPe 24" NA Standoff Configuration Landscape Staggered MintStieldeffTriblitaly Area Trib 20 PV AssemblyDead Load W-PV 3 psf NetWindUna .; at Standoff T-actual -316 lbs Uplift Capacity of Standoff T-allow 500 lbs 1_ Demand/Capatibt Max Allowable Standoff Spacing Portrait 48" 66" MairAitowatte Catileuer Porlralt 2 NA Standoff Conjuration Portrait Staggered StanchAfTritkitailr Area''s Trib , 22sf.. PV Assembly Dead Load W-PV 3 psf Net Wing Standoff - T -lbs Uplift Capadty of Standoff T-allow 500 lbs OCR 70796 CONFIDENTIAL- NE INFORMATION HEREIN JOB NUMBER: JB-9723195 00 PREMISE OWNER: DESCIMPTIOIN DESIGN: CONTAINED SHALL NOT BE USED FOR THE PHILLIPS, KENNETH E. PHILLIPS RESIDENCE Ian Wilson �`'!• it . BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8400 SOUTHWEST NORFOLK COURT 2.86 KW PV ARRAY ►�� PART TO OTHERS OUTSIDE NE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION NATH MODULES CARE), OR 97224 111E SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ 3055 aeanABw Way SOLARCITY EQUIPMENT, SNOUT THE WRITTEN NVERIIR: PAGE NAME SHEET: REV.. DATE San T:(650)539-1026,CA 94 236-1029 PERMISSION of soLARCITY INC. SOLAREDGE # SE3000A-US-ZB-U (971) 777-9659 UPLIFT CALCULATIONS PV 4 1/27/2016 (�)-SOL-an(765-2489)ww.Duct y.corn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:BR2040B200 Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE SE3000A—US—ZB—U LABEL: A —(11)REC REC26OPEZ OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24523705 Inverter; 30010W, 240V, 97.5% w/Unifed Disco and ZB, AFC' PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 I INV 3 In AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER I200A/2P Disconnect ® SOLAREDGE • I SE3000A—US—ZB—U (E) LOADS /Il A Li 240v R. o • L2N �� 20A/2P1 (0303 b GND EGO — 1 .� DC* DC+ ♦ A r�7 ----1�1——I �— GEC -—— `N D� Dc- MP 2 &3: 1x11 rh B • • - I I GND I EGC t EGC J I I N L — I I JEGCIGEC j CI- Z–Z CD — 7E GEC r 1 TO 120/240V I I SINGLE PHASE I UTILITY SERVICE I I I III II I 1 I I I Voc* = MAX VOC AT MIN TEMP POI—(1)CUTLER—HAMMER/B 0 PV BACKFEED BREAKER A —(1)CUTLER—HAMMER /DG221UR8 AC PV —(11)SOLAREDGE/P300-2NA4AZS DC Breaker, 20A 2P, 2 aces Disconnect; 30A, 240Vac,Non—Fusible, NEMA 3R /y PowerBox Optimizer, 300W, H4, DC to DC, ZEP —(2)Gr Rd Rod —(1)CUTLER—HAMMER !DGO3ONB 5/8 x 8. Copper Ground/Neutrd Kit; 30A, General Duty(DC) O—(1)AWG#10, THWN-2, Block (2)AWG#10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC -g-(1)AWG#10, THWN-2, Red OJL(1)AWG#6,Stranded Bare Copper EGC Vmp =350 VDC Imp=8.07 ADC —(1)AWG#10, THW1-2, White NEUTRAL Vmp =240 VAC Imp=12.5 MC (1)Conduit Kit; 3/4'EMT AWG#6,StrandWG/8,.TH.W01-2,Green . . EGC/GEC-(1)Conduit.Kit;.3/4'.EMT. . . , . . . . . . CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9723195 0 0 PREkISE OAR DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Ian Wilson BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: PHILLIPS, KENNETH E. PHILLIPS RESIDENCE %�„�SolarCityNORSHALLITBEDISCLOSEDINWHOLEORIN Comp Mount Type C 8400 SOUTHWEST NORFOLK COURT 2.86 KW PV ARRAY ►r PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION PATH MODULES TIGARD, OR 97224 3055 CIea .way THE SALE AND USE OF THE RESPECTIVE (11) REC # REC260PEZ PAGE NAME SHEET: REV DATE Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3000A-US-ZB-U (971) 777-9659 THREE LINE DIAGRAM PV 5 1/27/2016 (868)—SOL—CITY(765-2489).nnx.sdarcity.com - Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC)(P01) WARNING (POI) Per Code: OPERATING CURRENT Per Code: Per Code: IFC 605.11.1.4 MAXIMUM AC - V NEC 690.54 INVERTER OUTPUT NEC 690.64.6.7 OPERATING VOLTAGE CONNECTION DO NOT RELOCATE Label Location: THIS OVERCURRENT PHOTOVOLTAIC DC (DC)(INV) DEVICE DISCONNECT Per Code: NEC 690.14.C.2 Label Location: WARNING (AC)(P01) ELECTRIC SHOCK HAZARD Per Code: Label Location: Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) WARNING (DC)(INV) TERMINALS ON BOTH LINE AND Per Code: - MAXIMUM POWER-- (DC)(INV) LOAD SIDES MAY BE ENERGIZED ELECTRIC SHOCK HAZARD A NEC 690.35 F POINT CURRENT(Imp) Per Code: IN THE OPEN POSITION THE DC CONDUCTORS OF THIS ( ) • PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER-_V NEC 690.53 POINT VOLTAGE(Vmp) UNGROUNDED AND INVERTER IS MAY BE ENERGIZED MAXIMUM SYSTEM_V UNGROUNDED VOLTAGE(Voc) SHORT-CIRCUIT (ISO) A Label Location: CURRENT(ISO) PV SYSTEM (AC) DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK DC VOLTAGE IS HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT WARNING (DC)(INV) r.'Ax MUM AC - Per Code: OPERATING VOLTAGE ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.B.4 Label Location: PHOTOVOLTAIC SYSTEM (C PHOTOVOLTAIC AC (AC)(P01) (C)):: : AC Disconnect Conduit DISCONNECT Per Code: (CB): Combiner Box NEC 690.14.C.2 _ Label Location: (D): Distribution Panel (DC): DC Disconnect CAUTION (D) (P01) (IC): Interior Run Conduit • Per Code: Inverter With Integrated DC Disconnect PHOTOVOLTAIC SYSTEM (INV): g CIRCUIT IS BACKFED NEC 690.64.B.4 (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR %bitj 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED .i•'� :SSan Mateo,CA`94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set 1�„ oiar(ity T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (888} m SOL-C (765-2489)www.sdarcity.com SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. a ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 Ze �. S p la y' 3/26/15 Ze o to r 3/26/15 Z This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch - General Design Information: Roof Pitch 4 Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Load Duration Wind Snow , design load landscape= 15.35 27.64 27.64 psf design load Uplift= 656 lbs N/A 's+''' g portrait= 12.28 27.64 27.64 psf tr Lateral= 357 lbs 290 lbs ery 85818 note:use 10 psf minimum Down Force= 1074 lbs 771 lbs OREGON Snow Calculations fy 4- To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing Calculations 4.„. , , Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 degrees. Uplift Spacing PRE : 12/31/'€8 Allowable Uplift Load FOR PAGES 1-4 uplift spacing = Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qh GCN (snow load spread over the length of the rafter) qh=0.00256 KZ KZt Kd V2 I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Exposure= C Roof Zone= Edge Zone Combinations: 14 30 D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof KZt= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.755 31.59 31.91.,',psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force lscape effective area= 13.0 ft2 GCN portrait= -1.5 iortrait effective area= 21.7 ft2 landscape down force spacing= 39"x 31191psf x 144 ft2 =89" Piandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf portrait down force spacing= 65"x 31.91psf x 144-ft2 = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf 656 lbs . landscape uplift spacing = 39"x 27.73 psf x 144 ft2 = 87" 656 lbs portrait uplift spacing = 65"x 25.89 psf x 144 in = 56" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 Zep S o to r 3/26/15 Zep S o to r 3/26/15 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+.120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load lateral spacing -_ Maximum Uplift Pressure Landscape= -27.73 module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf Ps=C5 pf Roof Pitch= 31 45 degrees landscape module spacing = -1.4545 x 31.91 psf+ 120.7273 = 74" pf=0.7CeCflpg Ce= 0.9 C5= 0.71 0.45 q= 1.2 pf= 22.68 22.7 psf portrait module spacing= -0.8182 x 31.91 psf+79.909 = 54" I= 1.0 ps= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" 30° Lateral 30° 27° Lateral Force Component 74" 48" 44" Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 290Ibs in landscape lateral spacing= 39"x 14.49 psf x 144 ft2 = 74" 2901bs in portrait lateral spacing = 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in portrait lateral spacing= 65"x 13.50 psf x 144 ft2 =48" ,, 0 ., 0 ^$OlafClty ZepSolar Next Level PV Mounting Technology ''-sitSolarCity ZepSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs ;.. ye► . RAe ` Leveling Foot Ground zep Interlock ," . .-; Part No.850-1172 , ETL listed to UL 467 3 y 1 Pte i f 'q, zep Braun. ..,,.:... . _,� " Rod Attachment ArraySklrr Comp Mount Part No.850-1382 IL,Milliell " Listed to UL 2582 Mounting Block Listed to UL 2703 , '';''' 4°14 ,,,, ti ��• Description :''' ,,,:*.i.7-:',,.;'1!,:',:-44'.::4*.H.::?7,E1,,,,:l..0,7,—Tz, • • PV mounting solution for composition shingle roofs T% 0 • Works with all Zep Compatible Modules °OMP!, • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices kik • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com 850-1460,850-1467 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM cc solar - • • = w solar - • • SolarEdge Add On forPower North AmericaOptimizer A P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America H (for60-ce11PV (for72•ceiIPV (for96-ceIIPV modules) modules) modules) P300 / P350 / P400 INPUT ORated Input DC Power" 300._,.. 350 . 400. W .,,. < ,,M11`..--'0'';`,'5,''''''-(440!'"? ., mss. Absolute Maximum Input Voltage you at lowest temperature) 48 60 80 Vdc 0J,>"'' €f<� ' 7 " .✓' givr4:rei MPPT Operating Range 8 48 8 60 8-80 Vdc e . ,� pyo Maximum Short Circuit Current(Ise) 10 Adc `f+ tR .2 't € r a 1•,� Maximum DC Input Current 12.5 Adc a i SF vs. u+ w Maximum Efficiency .. 99 5 % ,, �;,. ,„y ' Weighted Efficiency 98 8 % �. Overvoltage Category II ” OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER( } s5 O Mawmum utpu[Current IS Adc r Maximum Output Voltage 60 Vdc a rtd.k. r J� 1.� OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM M INVERTER OR INVERTER OFF) I g ,�"' t �: Safety Output Voltage per Power Optim zer _ 1 Vdc T ` ' 't"VitiV t STANDARD COMPLIANCE ;, i _'"'ejw" EMC FCC Part15 Class B,1EC61000-6-2,IEC61000-6-3 Safety \lag „ � � IRoHS NSTALLATION SPECIFICATIONS IEC62109-1(class YesII safety),UL1741 Maximum Allowed System Voltage 1000 Vdc -.;`,',,f,-,, fir`` Dimensions(W x Lx H) 141x 212 x40.5/S.SSx8.34x1.59 mm/in ,1,,� rz Weight(including cables) 950/2.1 gr/Ib "E.,' d Input Connector MC4/Amphenol/Tyco [J;,, z 1<, Output Wire Type/Connector Double Insulated;Amphenol , Output Wire Length D95/3D 1.2/3.9 m/ft Operating Temperature Range 40 +85/-40-+185 *C/'F -.4.41,,„;',!. M�' '� i Protection Rating IP65/NEMA4 T ` .4 ,,f . ri:47 Relative Humidity 0 100 % a ,. § z:mes wW�•mm�moa,.-reoa�e o sxoow�,�o enwez o.me. %Eh PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE sof _� € , SINGLE PHASE ? ;, , `t` .� i`5..., .a-s INVERTER..... ----- 208V 480V PV power optimizationat the modal'' "' sStringLength( Optimizers) 8 10 18 +�'Up to 25%more energy Maximum Power per String 25........ _...25.,,. 50 I ._. Supelta'ef6tiEneYt' 5%) Maximum StringwLengthOptimizers) 1 5250 6000 12750 W MinimumPowerO timizers I o gt (Power - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Parallel Strings of Different Lengths or Orientations Ves Flexible,system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety a USA - GERMANY ITAIY - FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us 1 \\\\ ENERGIZING LIFE TOGETHER tI-r t -- ' ^ ` ^� ^. X41 r`Ist• eC " C • r� ItiglINi;o:1-SlI 7S a,y W „des ). . Vs" x� s "r.,0„,,.. .lex s �'. apt 0•4 ° �' s r ^ 4' v s„ vrs ^ : , _ - rU "� rs3 ` t '4,:.. TY .. xs A tkkrrbell,,,,k-_,:::.:51„,:e:-.-:.:i..„:,.;:,,..!.,........4.i;51,,,rs: t8�. A f All measurements m orches -`', - a ^` Nominal Power-Pwrn(WP) 260 � ."' ;t WattClassSorting(WP) /-5 r��' d ; �, Nominal Power Volta VW:t. (V) 30.7 x-- - r - �, i Nominal Power Current-IMnn A) 8.50 {il� 4:141 ,�seri t pss sihlf( 5 Open Circuit Voltage-V0(V) 37.8 '. )1 r; �. , 1 Short Circuit Current-I5C(A) 9.01 - `.,I,. ` � 1 '� t \\ PanelEfficiency(%) 15.8 -^' �*t' Ty,°. et��to. '• �, A � The electr cal ch -t tics ith (:,,,r-mill the-ndicated values ofl c,Vor and Pat standard Test conditions(STC). ."_ zfoe \ Values at standard test cond tions STC(airmass AM 1.5 irradiance 1000 W�m',cell temperature 77°F(25°C)) "tue` ilin4 in-.?„.1-4,4- 11141'r eta s, `� t� At low irradiance of 200 W/m'(AM 1 5&cell temperature 77°F(25°C)(at least 97%of the STC panel effiuency wdl be achieved_ s. 1 ,i 7;; ��� � � � �� ��° s�� � 1�° � _.,_ ��; rs �, ., - _ a "*.. • Nominal PowerPM,p(WP) 197 ``^:�- ° - ;t Nominal Power Voltage-VM,p(V) 29.0 r i Nominal Power Current-IMrr(A) 6.81jjj1F -��'� t, _ "'s � 1, ShortClrcuttCurrent-Ist(A) 7.24 _ \ )1(/ \\ \'. " '"ltg4pogwAAA �`,1 '� �Z\ Nominal operating cell[emperature NOCT(800 W/m',AM LS,wlndspeedlm/s,amblent temperature 68°F(20°C)_ \ � l0 year productwarranty. V \, c �� 25yearlinearpoweroutputwarranty _y 1 „up (max.degressioninperformanceof0.7%p.a.). ` � _ '� �� \ UL 1703,fire rating.Type 1,ClassC 1 • 1l � � :` REC is a leading global provider of solar energy solutions. With more\ si\?<°e \\\\\ \ , , than 15 years of experience,we offer sustainable,high performing R C C `` `, products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better \4, ':// \ :\, \ \ • ` �4. �'1 `1 meet the world's growing energy needs.REC isheadquarteredinNorwayandlistedontheOslo5tockExchange(ticker.RECSOL).Ourl,600 ^ 1 employeesworldwidegeneratedrevenuesofUSD647millionin2013. \ www.recgroup.com ,SolarCity ZepSolar Next-Level PV Mounting Technology . DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE j�/ DWV DEBRIS GUARD COMP ROOF MOUNT 41111101 jj��jj COMP ROOF j Cie iiia DWV Debris Guard Construction Detail Debris Guard,close up c,pMPo�e`� Prevent blockages and keep vents open with the DWV Debris Guard. • Protects against: Fp a • Leaves • Rain cOMPPr • • Pine needles • Insects • Snow • Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. A • zepsolar.com ., This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1677-001 Rev A Date last exported:April 3,2015 4:04 PM • CC solar - • • Single Phase Inverters for North America solar • •• SE3000A-US/SE3800A US/SE5000A US/SE6000A US/ LLJ SE7600A US/SE10000A-US/SE11400A-US F- SE3000A-US ISE3800A-US SE5000A-US SE6000A-US ISE7600A-US SE10000A US�SE11400A-US j OUTPUT SolarEdge Single Phase Inverters CC 9980 @ 208V I Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA 10000 @240V W Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA For North AmericaMin.-Nom.-Max.," 545°@24°" _. 1095°@24°" AC Output Voltage Min-Nom.-Max 10 I 183-208 229 Vac SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ Ac output Voltage Min.-Nom.-Max.l'1 SE7600A US/SE10000A US/SE11400A US Z 211-240-264 Vac AC Frequency Min:Nom.-Max.1'I 59.32-:;-26008.v5(with HI country setting 57-60-60.5) Hz -. . _ r , E, -- --- --- 48 @ 208V r, x Max.Continuous Output Current 12.5 16 25 32 47.5 A _ • '`s•°' . .. -.. ._._ 21@240V • 42@208V GFDI Threshold 1 A i. �, Utility Monitoring,Is an Protection Country Configurable Thresholds Yes Yes_ INPUT c Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 .15350 W � qG " Transformer less,Ungrounded Yes �` ,,, ,r riattt, rT¢* : „. Max.Input Voltage ... .500 Vdc V,ViB -4.. s. t o -, Nom.DC Input Voltage 325 @ 208V/350 : 240V Vdc 11'Z t3tiT " a.,y f ..... .. .... i,,a it}�% .3 Max.Input Current' 9 5 13 16.5 @ 240V 18 23 33.0208V 34.5 Adc , .t- 15,5 @ zaov 3os @ 240V Max.Input Short Circuit Current 45 Adc '`- Reverse Polarit Protection Yes € t:cliePitt r r v,;7 x e Ground-Fault Isolation Detection 600ks:Sensltiv ty r �.,.a -- '034•114'."'"',13'"', 41rA Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 �`� 97.5 @ 208V 97 @ 208V , CEC Weighted Efficiency 97 57 98 @ 24 97 5 397_8:5 V<!'4 9/.5 98 OV 975@240 7 2a r Nighttime Power Consumption s.2.5 -T ADDITIONAL FEATURES --�� - "�"� _._ v W x a • - .r Supported Communication Interfaces: RS485 RS232,Ethernet,Ziggee(optional) ,11,6 _ ,: , Revenue Grade Data,ANSI C12.1 Optionall'1,.. .. • �a ' 44 ,- i Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedj°1 6 x , �.` STANDARD COMPLIANCE_____- ,, a , Safety.... ...... ..__.__.__......_. . ._..UL1741,UL1699B,UL1998,CSA 22.2 ._.... ..... i .. Grid Connection Standards ,�, ,,, INSTALLATION SPECIFICATIONS EEE154l a€, a �"' Emissions FCC part15 class B R ''' AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG "„' €'`�`' ,., a DC input conduit size/ff of strings/ 3/4"minimum/1-2 stnngs/ 3/4"minimum/1-2 strings/16-6 AWG 14-6 AWG "F".„:',1. AWG range :`ia Dimensions with Safety Switch 30.5785: x 12.5 x 10 5/ in/ - 30.5x12.5x7.2/775x315x184 � -a::'1'4. (HxWxD) I 75 x 315 x 2 mm it Weigh[with Safety Switch 51.2/23.2 54.7/24.7 7 88 4/401423 60 I6/kg ... 'a' Natural convection t Cooling Natural Convection and internal Fans(user replaceable) ,...,�?.., fan(user I _- ;- _ � replaceable) �+ L,. a' he beR '�' Ir Sol y,� w RrR r .. ` Noise....... .......__._.__ _. ._ ._ . ...._._..<25 -...._ .__.. _ . . .<50. .... . . . d8A 77 `1 for NEC2011 69 m iianc Min:Max.Operating Temperature I I a 1 1 -13 to+140/-25 to+60(-40 to+60 version available s) -F/-C as .€€ Range . . € i i i - DF � r� s� L {- Protection Rating NEMA 3R ,-.Small,lightw c d easy to ll on.provided bracket )y Irl For other reg anal sel4ng,please contact Sol Edg pport p ,,,.,r ,y'; [ PI A h gher current source may be used,the nverter w II m1[is input current to the values stated -': Buiit-in module-level monitoring 131 Revenuegrade nverter p/N StosssA u5000NNR2lint]GWW-nverter SE]600A-U5002NNR2i. Hl Rap d shutdown kd P/N sE1000-RSD Sl • r Internet connection through Ethernet or Wireless . Isl y0 version P/N:SExxxsa.xSuvxNNu4(for 7600W inverter:SE]600A-uSuO2NNU4i. ', .. Outdoor and indoor installation . Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 EIl, r.liM Rol-IS USA-GERMANY-ITALY-FRANCE-JAPAN-CI-1INA-AUSTRALIA-.iHf:NETHERLANDS-ISRAEL. www.solaredge.Us