PFI2016-00051 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12016-00051
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/14/2016
Parcel: SEG1423, 1434, 1479
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: Adjacent to 13475 SW 110th Ave. Replacing UG Primary Cable-275 ft. See job sketch for more details.
Owner: FEES
Description Date Amount
PFI Permit Fee 03/14/2016 $300.00
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
TSAHAI ANDERSON
10800 SW AVERY ST
TUALATIN, OR 97062
PHONE: 503-612-6106
Total $300.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant Not Present
Signature:
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12016-00051
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code,and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced, with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
Kenny Fisher at 503-816-6146
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard MAR 0 7 2016
GE WORK ORDER# M1429240
PUBLIC WORKS — ENGINWWNQIGARD
■ PLA INMNG NEF N
�f
Public Facility 15F vent (PFI) Permit
DESCRIPTION OF WORK(in the right-of-way) REQUIRED SUBMITTAL
Check one: W Utilities ElSidewalk/driveway approach El Street improvements ELEMENTS
Detailed description: Replacing UG Primary Cable - 275ft 8 Minor work in right-of-way
(sidewalk repair,curb cut,street
See Job sketch for more details. opening,etc.)requires:
•Application form,completed
and signed
•Submit one(1)copy of scaled sketch
Property address/location(s : 13475 SW 110th Ave Tigard, OR of the proposed work to be done
•Submit one(1)copy of traffic
control plan
–OR–
Phil Merriman/Tsahai Anderson ❑ Substantial project work requires
Applicant's name: above items and professional
Address: 10800 SW Avery Street engineered plans for:
Tualatin OR 97062 •Street widening
Ci /state: Zip: •Subdivision infrastructure
Phone: 503-804-3579 Email: TBDSupportAvery@pgn.com •Main utility line extension:
- Storm Drain,Sanitary—Tigard
- Water—Tigard Water Service
Contractor's name: PGE Area(includes Durham,King City
CCB#: 103663 Expiration: and a portion of unincorporated
Washington County)
Address:
City/state: Zip: DELIVER APPLICATION TO:
City of Tigard
Phone: Email: Planning/Engineering
13125 SW Hall Bbd.
Engineers name: N/A
Tigard,OR 97223
Applications for"minor work in right-of-way"
Address: only may be emailed to:
City/state: Zip: ro ermits eigard-orgay
Phone: Email:
Case No.: YOFilQu(p"
Estimated value of work (within the public right-of-way): $
Application submittal fee: 3�
Is work related to a LAND-USE DECISION? ❑ Yes & No Application accepted:
If so,please specify (MLP, SDR,SUB, etc.) case #: By: S Date:
Is work related to a BUILDING PERMIT? ElYes 8 No Applicata n re 'ewed:
If so,please specify(BUILDING PERMIT)case#: By: Date:
Applicants/notified:
By: / ZZ Date:
I:\CURPLN\Masters\land Use Applications Rev.07/16/2014
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 www.tigard-or.gov • 503-718-2421 • Page I of 4
APPLICANTS
NOTE: Person specified as "Applicant" shall be designated"Permittee" and shall provide financial assurance for work.
*When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written
authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written
authorization with this application.
BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT:
• The above request does not violate any deed restrictions that may be attached to or imposed upon the subj ce t propel.
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in the plot plan, attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
SIGNATURES of each owner of the subject property required.
Digdally signed by TSAHAI ANDERSON ^A ^r
TSAHAI ANDERSON omml=TSAHAIANDERSON@PGNCOM,_US TSahal Anderson n 1 3/3/16
Date:2016 03.06 13.59:36-06'00'
Applicant/Authorized Agent's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of 4
DEVELOPMENT ENGINEERING FEES
1. Public Facility Improvement(PFI) Permit:
Part 1: Required submittal fee$300.00
Part 2: All non-water system improvements
Engineer's estimate X 5% (less $300.00 submittal fee)
Engineer's estimate X 2%Plan Review
Part 3: All public water system improvements
Engineer's estimate X 12%
Total Permit Fee = Part 2 + Part 3
PFI Permit Fee Exemptions:
There will be no permit fee charged,or assurance required for the following types of work:
• Sidewalk or,driveway repair(less than 20 lineal feet)
• Relocate or replace mailbox
• Ditch cleaning that does not involve regrading.
• Weephole repair
• Curb repair or replacement (less than 20 lineal feet)
• Lawn sprinkler system installation or repair
• Street tree pruning or planting
• Planter strip landscape maintenance
• Test wells
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 Page 3 of 4
r—
SAMPLE SKETCH:
SAY
Edge of Pavement
I Ditch _t
Streetlight ------------- —r---
• - Raaf Dna,
r M—
1 �
i
' T—LTi oj�os cf-Selrw'er" 11:
I I -
I
IN
I �� Existing House
I r� Existing
F I �i Driveway
31 I
CI � I �•
a i r
vl � 1
o, I I
aI I v
d' I -
a,
-,E I
0 1
Existing Shop �
Powerpole I I a
------- 95� ------�---
property Line-
1
QI Fire Hydrant(FH)
I � i
Scale: I"=30'
I � �
1 I
I I
I I
i I �
MINIMUM SKETCH REQUIREMENTS (Put"N/A"if Not Applicable):
North arrow Property lines &dimension Slope of property
Street& street name(s) Existing building,structures Utility&street light poles
Proposed work Existing curb or edge Trees
Existing S/W or of pavement Existing utility locations
D/W apron (sewer,water, storm)
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 - www.tigard-or.gov - 503-718-2421 - Page 4 of 4
Page 118 2011 Edition
Lane Closure at Intersection with Flagging Diagram 620
Diagram 620 covers work within an intersection when normal traffic control
must be interrupted. Work vehicles may or may not be in the work space.
1. During flagging, traffic signals shall be turned off. Contact the road
jurisdiction for approval and assistance (see Chapter 3).
2. For multi-lane facilities, traffic approaching the intersection shall be
reduced to a single lane on each approach. See Chapter 3 for
information on flagging through intersections.
3. There should be one flagger for each approach. One flagger may
control two adjacent approaches if sight distance, low volumes on side
roads, and flagger position allows for safe operation and clear direction
to motorists. For low traffic volume intersections (fewer than 400
entering vehicles per day), one flagger may be used.
4. The"ONE LANE ROAD AHEAD" (W20-4)sign is optional and should
be considered on high volume or high speed roads, or when extended
queues may be expected.
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs Buffer
Speed A B c Space
20 50
25 100 100 100 75
30 100
35 40 350 350 350 125
150
45 180
50 500 500 500 210
55 250
Chapter 5 December 2011
2011 Edition Page 119
Lane Closure at Intersection with Flagging Diagram 620
pAAD
word(
AHEAD
LANcowl ROADBE
e C 1
B
PREP
B
A ropdona9
ROAD
1001L M— E RPD
' 70 sloe WORK
� AHEAD
A B B C
Buffer
,00iL Mmc+i
C B B A
Rao BE
WORK
AHEAD TO Prop 100t Mm
Row
Tt
copft4 1111 A
A
B
*.EB (00-4
1 1 C Row
Rao
want
AFffM
December 2011 Chapter 5
Page 84 2011 Edition
Stationary Lane Closure with Flagging Diagram 320
Diagram 320 covers total closure of one lane of a two-lane, two-way
roadway. See the detail inset for the layout if using a single flagger to control
both directions of traffic on low volume roads (less than 400 ADT)with good
sight distance as discussed below.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Flaggers at each approach are required if any of the following
conditions exist:
a. Night Operations.
b. Work space is over 200 feet in length.
c. Sight distance is less than 750 feet from each approach
through the lane closure.
d. Traffic volumes are greater than 400 ADT.
4. The length between the Flagger Ahead signs shall not exceed one
mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one
mile.
5. Cones should be used to outline the work space when curves or other
roadway alignments prevent clear direction for the motorists to pass
the work space safely.
6. Cones along the work space are recommended when posted speeds
are 45 mph or greater,when working under heavy traffic or when travel
lanes are narrower than 11 feet.
7. Extended queue signing (see Diagram 54)should be used when
traffic queues extend beyond the initial advance warning sign.
8. When flagging near an intersection, the "Flagger Ahead" (CW23-2)
sign should be visible to traffic entering from any side road. Additional
advance warning and Flagger Ahead symbol signs may be placed on
the side road(s).
9. Sign set-up and flagger placement shown may be used for intermittent
full road closures of 20 minutes or less.
10. The"ONE LANE ROAD AHEAD"(W20-4)sign is optional and should
be considered on high volume or high speed roads, or when extended
queues are expected.
Chapter 5 December 2011
wv I------ ----- ----� N No
f1 N O A A W W N N
'00 0
� (T O(Jf O fly O CT O �rws I W �
3 a I Single Flagger Operation ,.
for Low To,
(Optional) o m
LI
Cm wC, o y N m I c�T<400) ro emr xao I o:
0 0 o mBE
I " " I PREPARED ONE LANE
m AD
n I B H B H c H I TO STOP AHF r
o 'o m oo I 4— 'n°' 4— I
0 0 0
m I — —• — — ♦— I ROAD
I r•® • WORK
o o n> > I K c•t a•t e K A I-- AHEAD
0 0 o m N I
mo,
°* W
G.
NN���+ Nm I roeia I ISA
O OOO(NTO�O t;'�` v I moo I ,v
PpMnM
A B B C
I-- -------- -----i H H 3
f' max s
d
. ' ® •. F
cn
13
K K K K
B
Buffer
Protection Vehicle
ROAD -- w/TMA(both Optional)
WORK Th'■1•� See Chapter 4 _G
AHEAD
BE
ONELANE PREPARED p�
ROAD AHEAD
TO STOP Two Flagger Operation 3
CD
(Optional)
N
O c�i,
i
LEGEND
10930 20'-Unknown WR CHECKLIST
Open 2003 ITEM YES COMMENT
13445 ; w, REMOVE FACILITIES _INSTALL FACILITIES
11155 etiPv, z HOLEDIGGER
8501164 F Boots
JWL 3 VTI INSTALL ADDITIONAL FACILITIES/MODIFY FACILITIES
Install: 3 VT- 4 BACKHOE
ELBOW KIT-JKTO C�ABLE-#2AL I ROW 50'
Fes , PGE TRENCH CONDUCTORS
10920
ORE X 275 FT
cv I INSTALL
13475 ' 1 LOCATES X _______ 1-N2 AL{PR JKT-D PRIMARYPROVIDED
645 I U AND INSTALLED BY PGE.
20' > STAKING 1-2-CONDUIT PROVIDED&INSTALLED BY
1 2 1-- I Q. PGE APPROVED CONTRACTOR.
11145 SPANI-2 PL4410 TO VT6324: I N 2r FLAGGING X
Install: ♦ I J
(275)l-PHASE OF#2 AWG,AL,EPR, TREETRIM
W I m ABANDON02AL
(275')CONTRACT BORING 11/ LANDSCAPE GROUND ABANDONED CABLE PER LC22035-7
(275')1-2"PVC CONDUIT Q I 10910 EASEMENT
Abandon: N I 10900
(275)1-PHASE OF JKT#2 AL DB Lb x Q PERMITS X TIGARD
1 505 N TRAFFIC PLA X
C2 1-03D
11135m' CUTSHEET 1-LINE DIAGRAM
2 UG CIR.VER.
TRANSMISSION 82AL
VT-6323
WL 1 PL4410: I N SHUTDOWN
Install: N vl -6324 0 h
1-2-IN PVC COND UNIT W/12"BKTS LL
1-142 C/O-FUSE 40T m ; O O CUSTOMER
X I
sHuroowN 7 ACCOUNTS / { --
Remove: 13535
11215 1-2-IN PVC COND I W W DOOR HANGAR
1-142 C(O-FUSE 40T h� 10965 10915 1
- 4410 I CONTACT —?—�T---
40'4 t COMPANY JOB SITE
1960 I 4388
�r r I ROW 50 40'-4 PH# C# p° B 2
r3.`� coNouR I FOC 2T 1900 T SSR _
11 143 F40T R
14240T ¢ ,
N
B 2 A[;Sf� O Z
1205
0 30 60 120 Feet 2-B-2/o AL m
Open SW FA/RHAVEN ST B2 AAC
1 1 1 I I 1 1 I I U THINK
Q SAFETY
13565 m 1os6o 10910
FIRST �.� B2Acsa
PGE
NYDEVIA7701V FROM THISDE96N MUST
GE
�Q'f�V14 IA SW Df RRY DELL C' REAPPROVED BYTHEPGf PROlfC7MANAGER PGE CONSTRUCTION DRAWING
AS-BUILT VERIFICAT10N6 NESC VIOLATIONS CORRECTED
RIGHT-OF-WAY PERMIT NOTICE: "
401� A PERMIT FROM THE LOCAL JURISDICTION IS REQUIRED BEFORE ANY Foreman: E oma. Date:
WORK IN THE RIGHT-OF-WAY MAYBE PERFORMED. ONLY PGE APPROVED General Foreman: Date:
rn S W PARK ST CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL
AGREEMENTS WITH PGE WILL BE ALLOWED TO WORK UNDER PGE'S PERMIT SDPUFJVG REVIEW SBUILT BYDESIGNER.
C m S W THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 48 HOURS DATE r . .ALcACCOUNT A— J B N
g15V' 9DA� )MIRA BEFORE WORK IS TO BEGIN.ACOPY OFTHE PERMIT MUST BEONSITE. 02/29/2016 1"=60' 1070001 1 14628 M7429240
CT SW COOK LN TITLE
� PGE- REPLACE UG PRIMARY CABLE-275 FT
j
ATTENTION: CALL 811 BEFORE YOU DIG TIGARD-TIGARD 13/` CIRCUIT SI/F
Q 11x17
( OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED LOCATION
P BY THE OREGON UTILITY NOTIFICATION CENTER. � 13475 SW 110TH AVE,TIGARD,OR
S1Y FA!RMAVEH 5T SW FAIRHAVCN$T THOSE RULES ARE SET FORTH IN OAR 952-001-0010 • DESCRIPTION
THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OF ` FROM PL4410 TO VT6324 SHEET
q Oq_ THE RULES BY CALLING THE OREGON UTILITY BEAVERTON COUNTY I SECTIONS
JOB SITE NOTIFICATION CENTER ADMINISTRATION @(502-232-1987) LINE CENTER WASHINGTON C21-030 WORK WITH
Y# G Vicinity Map TO REQUEST UTILITY LOCATES CALL THE OREGON wIQ�M�lY b�OYY. OLS/GN BY PHONE(9l1 OHAWNBY 1 of 1
SW FAIRFiAYEN WAY UTILITY NOTIFICATION CENTER,811 AT LEAST �� a1Js"��DOR PHIL MERRIMAN 804-3579 HUGO MEJIA
BEAVERTON,OR.
2 BUSINESS DAYS PRIOR TO EXCAVATION