Loading...
Report • /3.;-0/6 oao -- 7 COOPER Wheelockt):, ? 2016 City c.- BOIL , Series ET Speakers`theSpeaker Strobes :_::... FIRE FIRE SERIES ET70 SERIES ET90 Description Features The Wheelock high performance Series ET Speakers and Series • Approvals include: UL Standard 1971, UL Standard 1480, ET Speaker Strobes provide high audio output,clear audibility,dual New York City(MEA),California State Fire Marshall(CSFM), voltage(25/70 VRMS)capability and field selectable taps from 1/8 Factory Mutual(FM),and Chicago(BFP) See approvals by to 8 watts.They are designed to meet the critical needs of the life model in Specifications and Ordering Information safety industry for effective emergency voice communications,tone • ADA/NFPA/UFC/ANSI compliant signaling and visible signaling to alert the hearing impaired. • The low profile design incorporates a speaker mounting plate Meets OSHA 29 Part 1910.165 for faster and easier installation. Each model has a built-in level • Wall mount models are available with Field Selectable Candela adjustment feature and an aesthetic two(2)screw grille cover. Settings of 15/30/75/110cd or 135/185cd (Multi-Candela The Series ET Speaker Strobe models incorporate Low Current models)or 1575cd(Single Candela model) draw Series RSS Strobes. • Ceiling mount models are available with field selectable Strobe options for wall mount models include 1575 cd or Wheelock's candela settings of 15/30/75/95cd or 115/177cd(multi-candela patented MCW multi-candela strobe with field selectable candela models) settings of 15/30/75/110cd or the high intensity MCWH strobe with • Strobes produce 1 flash per second over the regulated voltage field selectable 135/185cd. range Ceiling mount models are available in Wheelock's patented • 24 VDC with wide UL"Regulated Voltage"using filtered DC MCC multi-candela ceiling strobe with field selectable intensities or unfiltered VRMS input voltage of 15/30/75/95cd or the high intensity MCCH strobe with field • Synchronize with sync modules or power supplies with built-in selectable 115/177cd. sync protocol The strobe portion of all Series ET Strobes may be synchronized • Field selectable taps for 25 or 70 VRMS operation from 1/8 when used in conjunction with the Wheelock SM, DSM sync watt to 8 watts modules or the Wheelock PS-24-8MC Power Supplies with patented Sync Protocol. Wheelock synchronized strobes offer • High efficiency design for maximum output at minimum an easy way to comply with ADA recommendations concerning wattage across a frequency range of 400 to 4000 HZ photosensitive epilepsy. • Fast installation with IN/OUT screw terminals using #12 to Series ET70 and ET90 Speaker Strobes are UL Listed for indoor #18 AWG wires use under Standard 1971 (Signaling Devices for the Hearing Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan®lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. Color options for Series ET speakers and speaker strobes are red, white,or nickel plated. YL /lO) 11> MEA I" "'I APPROVED S5391 151-92-E 7125-0785:152(ET70/90 MC) S2652 7125-0785:146(ET7OWP) NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances(Indoor use only). • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology"Listed Voltage Range". Table 1: Average RMS Current* ET70 Strobe current-Wall Mount ET90 Strobe current-Ceiling Mount ET70/ET90 Speaker 241575W 24MCW 24MCWH 24MCC 24MCCH Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: ET70/ET90 UL Reverberant dBA @ 10 Feet** * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS watts 1/8 1/4 1/2 1 2 4 8 current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at ET Speaker 78.3 81.5 84.4 87.2 90.1 92.8 94.9 the minimum listed voltage(16v for 24v units). For ET Speaker Strobe 78.3 81.5 84.4 87.2 90.1 92.8 94.9 audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR **dBA ratings are based on UL testing under UL Standard 1480 ratings,see installation instructions. Wiring Diagrams# SERIES ET SPEAKER&STROBE OPERATE SERIES ET SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY(NON-SYNC OR SYNC) WITH MULTIPLE DSM MODULES DSM#1 FROM TO NEXT PRECEDING Strobe NAC Cir. Sync MEM APPLIANCE APPLIANCE 2+ OR VOICE - OR EOLR T' ■-�;_ Note: Figure EVACUATION r PANEL ^ DSM#2 shows intercon- _ L Strobe NAC CilliSync nection to strobe _ 1-f FROM + - — — — — — +TO NEXT B® ® through sync PRECEDING STROBE ORIII STROBE. - - — I I 1 r — — —— — - EOLR C module. Speaker y-1 SYNC MODULE, I ' 'DSM#3 POWER SUPPLY ,� II , A P Sync portion requires 2 OR FACE ii �i �i Strobe NAC Ci Ii z�+ ® ® separate conduc- tors to FACP. DSM Interconnecting wiring shown.Maximum of STROBE SPEAKER twenty(20) SERIES ET SPEAKER STROBE APPLIANCES SERIES ET SPEAKER STROBE APPLIANCES&RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH PS-12/24-8CP and CLASS "A" DSM PS-12/24-8MP Series PS-12/24-8MP STROBE + NAC SYNC / CIRCUIT - 0 ET [ C OUT r+9 UT 1 OUTPUTS \ EOLR T ; +IN1 Ir® ®.'®, F9-CLASS I-4 �` _� MINUS I A OR FACP �� ,+AUDIBLI /� 2-CLASS ET \ MINUS 2 l• 1 o p I,IN 2 �®IECE14 STROBE Q+OUT 2 �� NAC ET a 41) CIRCUIT RETURN Series PS-12/24-8M For wiring information on the PS-24-8MC Power Supply, please refer to Data Sheet#8900. Specifications and Ordering Information Strobe Sync w/ # # # Agency Approvals Model Order Wall Ceiling Non- SM,DSM or Strobe Can- Model Model Model Mounting Code Mount Mount Sync PS-12/24-8CP/MP dela Color Color Color Options UL MEA CSFM FM BFP RED White Nickel ET70-24MCW-FR 9020 X - X X 15/30/75/110 X - L,O,P,Q,U,Y X X X X X ET70-24MCW-FW 9021 X - X X 15/30/75/110 - X L,O,P,Q,U,Y X X X X X ET70-24MCW-FN 3091 X - X X 15/30/75/110 * - X L,O,P,Q,U,Y X X X X X ET70-241575W-FR 7848 X - X X 15(75 on Axis) X - L,O,P,Q,U,Y X X X X X ET70-241575W-FW 7853 X - X X 15(75 on Axis) - X - L,O,P,Q,U,Y X X X X X ET70-241575W-FN 3092 X - X X 15(75 on Axis) - - X L,O,P,Q,U,Y X X X X X ET70-24MCWH-FR 3472 X - X X 135/185 X - - L,O,P,Q,U,Y X X X X * ET70-24MCWH-FW 3475 X - X X 135/185 - X - L,O,P,Q,U,Y X X X X * ET70-24MCWH-FN 0061 X - X X 135/185 - - X L,O,P,Q,U,Y X X X X * ET7OWP-2475-FR 9077 X - X X 180 X - - M(Outdoor) X X X * * ET90-24MCC-FW 3164 - X X X 15/30/75/95 - X - L,Q,U,V,Y X X X X * ET90-24MCC-FR 3163 - X X X 15/30/75/95 X - - L,Q,U,V,Y X X X X * ET90-24MCC-FN 3186 - X X X 15/30/75/95 - - X L,Q,U,V,Y X X X X * ET90-24MCCH-FW 3473 - X X X 115/177 - X - L,Q,U,V,Y X X X X * ET90-24MCCH-FR 0139 - X X X 115/177 X - - L,Q,U,V,Y X X X X * ET90-24MCCH-FN 0062 - X X X 115/177 - - X L,Q,U,V,Y X X X X * ET7O-R 7840 X X - - - X - - L,O,P,Q,U,Y X X X X X ET70-W 7844 X X - - - - X - L,O,P,Q,U,Y X X X X X ET7O-N 3097 X X - - - - - X L,O,P,Q,U,Y X X X X X ET9O-R 7842 X X - - - X - - L,Q,U,V,Y X X X X X ET90-W 7846 X X - - - - X - L,Q,U,V,Y X X X X X ET9O-N 3098 X X - - - - - X L,Q,U,V,Y X X X X X # Models are available in either Red or White. Call Customer Service for Order Code&Delivery. *PENDING NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. Architects and Engineers Specifications The speaker appliances shall be Wheelock Series ET Speakers and speaker strobe appliances shall be Wheelock Series ET Speaker Strobes or approved equals.The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Signaling Devices for the Hearing-Impaired. In addition,the strobes shall be certified to meet the requirements of FCC Part 15,Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS,with selectable power taps from 1/8 watt to 8 watts. All models shall have listed sound output of up to 93 dB at 10 feet and a listed frequency response of 400 to 4000 Hz.The speaker shall also incorporate a sealed back construction.All inputs shall employ terminals that accept#12 to#18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The strobe shall be of low current design. Where, Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95 cd or 115/177cd for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 1575 strobe shall be specified when 15 candela UL Standard 1971 listing with 75 candela on- axis is required(e.g.ADA compliance). When synchronization is required,the strobe portion of the appliance shall be compatible with the Wheelock SM, DSM sync modules or Wheelock PS-24-8MC Power Supplies with built-in Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed),the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting.The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series ET speakers and speaker strobes shall be white, red or nickel plate. All speakers and speaker strobes shall be backward compatible. 00 COOPER Wheelock 273 BranchportAvenue XE NIA Long Branch, NJ 07740 Phone: (800)631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732)222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA S0310 ET 06/06 HN Series Effective October 2014 HS Series Technical Data TD001017EN Supersedes May 2013 ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners 40, `f with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes,voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. W The Wheelock Exceder Series incorporates high reliability and high FIREFIRE efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings(90, 95, 99 dB).All switches to change settings, can be set without the use .'J of a tool and are located behind the appliance to prevent tampering. �. P Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base(UMB)designed to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust, paint and damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation,while the ceiling models provide a captivated screw to prevent the screw from falling during installation. EAT,,N Powering Business Worldwide • Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series Features • Environmentally friendly • • Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw D • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings O Patented • 90,95, 99 dB Note:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. • Industry leading-8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 A WARNING • Ceiling: 15/30/60/75/95/115/150/177 PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Universal mouting base • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to • Ceiling and wall 120°F(0°C to 49°C)and maximum humidity of 93% (± 2%) UL • Mounts to 5 backbox types: 1 gang, 2 gang,4" square, 464(85% UL 1971). 3.5" octal. &4" octal. (100mm for international customers) • Series Exceder horns are under UL Standard 464 for audible Universal mounting base Contact cover signal appliances(Indoor use only). lig Compatibility and requirements f e �r • Synchronize using the Wheelock Sync Modules or panels with lir built-in Wheelocka Patented Sync Protocol ` �� r �' • Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage t • • Strobes produce 1 flash per second over the"Regulated Voltage" range Common base for wall and ceiling with 5 mounting options Compliance • Voltage test points for quick troubleshooting and easy spot • UL 1971, UL 464, ULC, CSFM, FM checking (wall models only) • ADA/NFPA/ANSI/OSHA • RoHS v n 2 EATON www.eaton.com HN Series Technical Data TD001017EN HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current CO 24VDC/24FWR 12VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current@ at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 0.197 - 0.242 0.282 - 0.125 - UL Max Current CC at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current CC at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - CC UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe _ AL = Alert Lettering(strobes only) FIN _ 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2.HSR=Horn Strobe,Red,Wall Mount sync w/117,M. or Example 3:HSW=Horn Strobe,White,Wall Mount Wheelower 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDCOO Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMBD � HSW 15/1575/30/75/95/110/135/185 X X UMBO 4 L. 4 -.l HSRC 15/30/60/75/95/115/150/177 X X UMBO ,„, 1 4 L ,�� HSWC 15/30/60/75/95/115/150/177 X X UMBO ,,..-' Strobes !_ 1. STR 15/1575/30/75/95/110/135/185 X _ X UMBO 1NL "*.....`' , 41! ,, STW 15/1575/30/75/95/110/135/185 X X UMBOi C,, STRC 15/30/60/75/95/115/150/177 X X UMBO ` STWC 15/30/60/75/95/115/150/177 X X UMBO ' J; Horn f` ~ ,,,..?)%ofr HNR X X UMBO HNW X X UMBO L i 1"1 HNRC X X UMBO Example: HSR Example:HSWC HNWC X X UMBO CC 12 VDC models feature 15&15/75 settings CO UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall I incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(11 flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30,60, 75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang,double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP).The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe • activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. MENA tarnamm WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperNotification.com ©2014 Eaton E_.t.IV All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No.TD001017EN All other trademarks are property Powering Business Worldwide October 2014 of their respective owners.