Loading...
Report (42) NE W aL.0S 60-5.5"vs-will 7c thio 13TUs ��ft 4'% •- \ S L , U/i/ T‹ --6-, &., lid, l RECEIVED MAR 6 2013 fI V, CITY IOF IGAAS 4 BUILD N CITY OF TIGARD was Approved C . [ p �I A i H 17�',, Conditionally Approved [ See Letter to:Follow [ Attached. Permit Number: EC-- 1 01 � � Addr I - -• &e.—!.___s �` Y / CJs By: c2 Date: l '31s ' Approved plans V shall be on job site. 11 OFFICE OFFICE COPY 44r* r e. •,(1 OA 014 )' If r ii414 / j::::11 IVN I M Ext T)►XGS 6-*iMEik go4 A i.t& . fa e,l OO d`D „b/£ ` ��BIS LZ I 0 Q NR�EIO3Lb�J�O 01 3TJF1 VIO bL-..b16 N�J'lLi • \ fl Q 40••••••07001111.1, rr ll/l<i C) 1 0 MAIM" .RJECTRCAL/GENERAL DATA - GE pew, HEAlmI\G PERFORMANCE _ Model: YrC09:F Ovesze 1 Motor HEATING-GENERAL DATA Llit Operating WAage 187-253 MCA WA Heating Model: Medun Lilt Rimer)/Verge: 208 MFS WA flit Secondary Vdtage 230 MCEt WA Heating IrpU( 150,000105,000 Lrit Heti 60 Heating CN ipit(Btu): 120000'84,000 U-it Phase: 3 No.Eune s 3 No.Stages 2 EER 12.6 3ada-d Motor Field Installed C 'erelzed Mator Gas Irl Presage MC:A 41.9 IvtCA WA Natral Gas(MnMa): 4.514 MFS 50.0 MFS WA LP(MrrMac) 10.0'14.0 MC8 50.0 IVOH N/A Gas Pipe Cbmection Sze 3`4' INDOORMOTOR Sar lord Md]r Overs zed Mdbor Feld Installed Oversi zed Md7or Wrrber 1 NUrrbe' WA Nrioer. WA Ftrseponer. 3.8 I-trsepaner. WA Ft esepaner. WA Motor Speed(FPM): — hrbtor Speed(FPM) WA Motor Speed(FPM) WA Phase 3 Phase N/A PI'S WA Fill L17ai Arrps 8.5-as FU I Load Or r w WA Fill Load Arrps WA Locked F3tcrArrps _ Locked fdYo-Ants. WA Lod<edRica'Arms MA CON/PRESSOR ()mut 1/2 OUTDOOR MOTOR N-rrber. 2 Nurber 1 Ha-sepaner. 3.8/2.8 I-tarsepove. 0.75 Phase 3 Mdor Saeed(FRA): 1 100 Famed LmdArrps 15.9/10.0 Phase: 1 Locked FbtrrArrFa 110.071.0 Full LoadArrps 3.5 Lacked RaorGrrps 9.3 FOV EXI-I8UST ACCESSORY R L I LtzS REFI GERANT (2) (Feld I rstal led Poser Exhe rt) ` Type R410 Riese 1 Twe Hrseponer. 0.87 F died: YTS ! FadaryCharge Motu'Speed(l RM): 1075 NrrLer 4 Cinit#1 5.5 lb FUI LaadArrps 5.7 Recommended 20k2557 Omit K2 4.2 lb Locked Rota-Az f FA 13.6 NOTES 1.Makinvn(HAO Orait Beaks sang is for install dic s in tte Lilted Sates orly. 2 igerart charge is an app-cxirrate value.Fa-a more precise value,see int re replate and seri ce irslncti ors. 3.Value dxs rd include Pdner EMaust Accessory. 4.Value i'dudes mers zed rrotor. 5.Value does not include Parer Exhaust Accessory. 6.EER is rated a Al-a cendtims aid in accadarce v ith CCE test pi:nedues. • Page 4 . ID nbuifir I NBTALLED ACCESSCR ES NET 1AEI GFiT DATA ACCESSORY i WEIGHTS ECC7JCMIZE 36.0 Ib MOTCRZHJQITSCEAIROM/PER C '1/40 MAMJALCUTS CEAIRD . BA 3v€TRCREIJEF Ov8RS ZD M CITCR o i ��r/�`t` E LTCRVEMOTOR o a IiJ1l��I. 11,�ff l POAERI 4-AUS- [ 80.0 Ib o a �tkk�, iiiiii T-FIZUGHTTHEB4gBFCTRC�+L(F1CP' ```�� WTMCLNTEJCIR311T9�1 2(F1CP�l `� W TMCI NTED CI SDNECT(R C-6) PQ/EREOCC NM JENCE QJTLET(FICP� HNCEDCCCFS(FICP O \O 1-14ILGUAF3J arlacE L>=I tL-I c--(S.PPLY/F E TLF N NOJAR Cx7JTRCL p xc jc s/ELECTRON_ OCR BZV HGHT STAANL6SST1E L FEAT BC-ANGER FE-EAT FCC r CIFE BASCWTNHG-RS OCRNER aGHTS CENTER CF GRAMMY • 151511=RNG 1 NET OA 340.0 lb ( 0 249.0 lb (E)LBJCHT (F)WIDTH I 1124.0 lb 10Q6.0Ib O 233.01b I QD 2134.0 lb 41" 23' (NOTE 1.CCFd is WHG1-FTSAFE G1\EJ FCRIN=CF3v1Al1GN GTLY. 2.TOE ST1 MATE SiPPIN3 V'HG1-(TADJ 5 LE TONEf V\BG1-FT". 1 3.B4SCLNTVABG-ITCCESNOTINCLUCEACC 'W8G1-fr.TOCHTANTOTAL VBG-fT.ACOAOCESSCR e FEET V B CHIT TOB39C LNTWB GHT. fres4.44.4.4%.0%44.44%. 4.VJBG-f1S FGR CPT1 C'6 NOTUSI tU ARE>5 LES. \� 17-/�=ice`/ \ `' E �� e . i F l PC S/BOOL RGCaNGAND CENTER CFGRMTY Page 5 MANE"11111 CLEARANCE FFCRA TCP CF WIT 72' CLEARANCE 36' CLEARANCE 48' ..,,,,,< ,...1.......-.._..... .. ..., .. '''''''''''''',.. " N! :, ,z t:1 1 i 1 iiiii * hzi,,.• 1 1 ..141,,,, \ RETLRN i en DCMNFLG,NQEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36' RoCKPCED G-S/ELECTRIC CLQ FCCF CP9JI e I I -1 WTCUM M1ETh I I \`� 53 114" —_, L 46' --i 889'8' PACKPCD CSS/U 1T C CCONFLCVVTYFI CAL F CCF C FENNG Page 6 b • IT • POAEREXHAUST 111 63/4" 4 161!2' FCIAIER Da-PLLSTFPD HOOD POS • Page 7 4tINtittNitiNtto.: .,,T4t**::::::ttttttitet%*ittetet%%:•••••••••••••00° • 6 7/6" • 00 00 -+— 163(4" ACCESSORY-ECONonI ZER Hcco • Page 8 r • nuita- General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F incooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll Compressors. Crankcase heaters shall be included on 6-10 ton units. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092,102, 120E). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1-phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-8Y2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick- adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 71/2-81/2 (high efficiency) have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser coil is standard for the T/YSC 10 ton models and 7'/2 ton high efficiency models. The microchannel type condenser coil is not offered on the 71/2 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction Improves re-cyclability. Galvanic corrosion is also minimized due to allaluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall Page 9 = M • be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double-sloped condensate drain pan with through the base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing" tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat,the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Accessory-Powered Exhaust The powered exhaust shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. Page 10