VDAIKIN ® Submittal Data Sheet
absolute comfort
Project Name:
Location: Approval:
Engineer: Date:
Submitted to: Construction:
Submitted by: Unit#:
Reference: Drawing#:
FTXN18KVJU RXN18KEVJU
cl
1 v
g /hut f 7P
tlteri Vie
FTXN18KVJU RXN18KEVJU
Std U.S. Warranty:6yrs Compressor,2yrs Parts Std U.S. Warranty:6yrs Compressor,2yrs Parts
Daikin AC(Americas),Inc.,1645 Wallace Drive-Suite 110,Carrollton,TX 75006 Page 4 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
(Dailun's products are subject to continuous improvements.Daikin reserves the npht to modily product dasign,specification;and information In this data sheet without notice and vAthout incurring any obhgahons)
i.
VDAIKIN AC® Submittal Data Sheet
absolute comfort
Project Name:
Location: Approval:
Engineer: Date:
i Submitted to: Construction:
Submitted by: Unit#:
Reference: Drawing#: I
Dimensional Drawing-Condensing Unit RXN18KEVJU
HANDLE
SPANS NAME."LATE MAN.irACT'JO=PS
51€i75 !11115'30,_(5 8i IS,9'005J 31 a,s,795) 2 I-' P,.ATE
161'1, 310.IND01101581. I
.1111111111111.1
10.111)
I = = U_, IIr_i JII I TOPVALvL
��11
e _
all• — `
If
SE PORT II il':!: :'7:;'
i
m - _-—1._ ��_-:: ��
__ - 12!131
12- 51,8-:tY;
''9,160.35)
ASIA LLA1108 LEG GAS STOP VALVE
PTaii IN CASE OF 451.05150 0,'1,4,,cu"
19.7.16(342' sTOR'VALVE COVER
51:4A!M1'a.,'''.:_, OUTDOOR A THC?MIST co
;II.D,S'A 1,p15.95-10:E'OR CONNECTION a-r'OLESFJ 50,,N1/41 ON BOLTS
W 111 DNA JO1Ni, 08 OR StlOi
4111111111111111111111,111111
E F I
22-5,8i57r) S-il 1191) "T
i5-1/2(495- ,�_ I
• -- 1
I' k I
r I I
13.1102.51
MINIMUM SPACE FOR AIR PASSAGE '.YALE HEIGHT ON All OVTLI T SIDE
-1.`SF, HAI,4;.1:411 00:
II: ? E
•• Q
7— ,
'"iti-"1"1-7
1::D:H.t.,,:50, —7:
L;N1T::'.N:',Hi m.;
•
Daikin AC(Americas),Inc.,1645 Wallace Drive-Suite 110,Carrollton,TX 75006 Page 3 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations)
IrDAIKINAC°
absolute comfort Submittal Data Sheet
Project Name:
Location: Approval:
Engineer: Date:
Submitted to: Construction:
Submitted by: Unit#:
Reference: Drawing#:
Performance
Indoor Unit Model No: FTXN18KVJU Indoor Unit Type: Wall Mounted
Outdoor Unit Model No: RXN18KEVJU Condensing Unit Type: Std SEER Heat Pump
Rated Cooling Capacity(Btu/hr): 18000 Indoor:80°F DB/67°F WB
Sensible Capacity(Btu/hr): 12680 Rated Cooling Outdoor:95°F DB/75°F WB
Max/Min Cooling Capacity(Btu/hr/kW): 18000/6800 Conditions
Cooling Input Power(kW): 1.5 Indoor:70°F DB/60°F WB
SEER: 18 Rated Heating Outdoor:47°F DB/43°F WB
Rated Heating Capacity(Btu/hr): 21600 Conditions
Max/Min Heating Capacity(Btu/hr/kW): 24000/6800 Rated Piping Length(ft) 25
Heating Input Power(kW): 2.2 Rated Height Separation(ft) 0
Heating COP(Btu/hr/Btu/hr): 3.52
HSPF: 8.5
Indoor Unit Details
Power Supply(V/Hz/Ph:) 208-230/60/1 ph Airflow Rate(CFM wet coil) 614/533/448/403
Power Supply Connections: L1, L2, Ground Moisture Removal(pt/h):
Min Circuit Amps MCA (A): N/A Gas Pipe Connection(inch): 1/2
Max Overcurrent Amps MFA (A): N/A Liquid Pipe Connection(inch): 1/4
Dimensions(HxWxD): 11-7/16x41-5/16x9-3/8 Condensate Connection(inch): 11/16
- Panel(HxWxD): N/A Sound Pressure Level(dBA): 45
Net Weight(lbs): 26.5 Sound Power Level(dBA): 61
Weight with Panel(lbs): Static Pressure Rated/Max(inWg) 0/0/0
•
Condensing Unit Details
Power Supply(V/Hz/Ph): 208-230/60/1 ph Compressor Type: Inverter
Power Supply Connections: L1, L2, Ground Capacity Control Range(%):
Min. Circuit Amps MCA (A): 15.5 Airflow Rate(CFM): 1603
Max. Overcurrent Amps MFA(A): 20 Gas Pipe Connection(inch): 1/2
Max. Starting Current MSC(A): Liquid Pipe Connection(inch): 1/4
Rated Load Amps RLA (A): 6.8 Sound Pressure Level(dBA): 53
Dimensions(HxWxD): 23-7/16x31-5/16x11-13/16 Sound Power Level(dBA): 67
Net Weight(lbs): 93
System Details
Refrigerant Type: R-410A Max. Pipe Length(Vertical ft): 65.6 ft
Holding Refrigerant Charge(lbs): 3.2 Cooling Operation Range(CF): 14- 115
Additional Charge(oz/ft): 0.21 Cooling Range w/Baffle(F): 0- 115
Pre-charge Piping(Length ft): 33 ft Heating Operation Range(F): 5- 77
Max. Pipe Length(Total ft): 98.4 ft Heating Range w/Baffle('F): 0- 77
Daikin AC(Americas),Inc.,1645 Wallace Drive-Suite 110,Carrollton,TX 75006 Page 1 of 4
Daikin AC TRL Generated Submittal Data
(Dalkin'c products are
www.daikinac.com
subject to continuous improvements.Daikin reserves the right to moldy Product design,specdicatbre and information In this data sheet without notice and*Mout incurring any obligaaoos)
L—
•
• VDAIKIN ®
•
Submittal Data Sheet
absolute comfort
Project Name:
Location: Approval:
Engineer: Date:
Submitted to: Construction:
Submitted by: Unit#:
Reference: Drawing#:
Dimensional Drawing-Indoor Unit FTXN18KVJU
.,/1((240;
SMIIM
«r/% MODEL NAME
'1111` PLATE
c.AIR FLCW J.4DOOR;
TEO(
PAaNAL BLOw0H ;'FOR PERFORMANCE AND MAINTENANCE)
THE MARK I')SHOWS PIPING DIRECTION D OI.NDTERM.NAL iiia
1 IIkyG I
LEFT t REAR 41.5,16110501 REARI ;
RIGHT , W
(SRN;E-04 MAIRTENANCc it 1,
I 41 '
• MINT,Si16(50)J V2 g
INCLUDING j MM.1.15.'16(501 y.
{,
INSTALLATION PLATE I /SPAT:"AOR MAINTENANCE)
REQUIRED SPACE
OPERATION LAMP
SIGNAL RECEIVER
INDOOR UNfT OK'OFF
SWITCH
.RO DEIEMP THERM45TOR [... .. ._.. ,41
ENI -1-i TIMER LAMP GAS P!PE+12CuTDRAM HOSE FO
FROM GPiLLE FIxJNG$CREWS (THE LENGTH OF PIPE OUTSIDE /CONNECTING PART •
FLAPS (INSIDE) THE UNIT;ABOUT 13.3:81 1.0116.0111 t/16i
•
LIQUID PIPE 4(i4 CuT (THE HOSE LENGTH OF OUTSIDE
' (THE LENGTH CF PIPE OUTSIDE THE UNIT'.ABOUT 1+5rt61
THE UNIT:ABOUT 15-3/81
•
aek—SIGNAL TRANSMITTER A,.,0FuoNTAI BLADE BLADE ANGLES ‘
2-1:4(581 3/4(18/ IAU`OMATICI
• il Hi-
COOLING HEATING DRY 41
• 41-'16(10.)1
•
""�` 35-Y16(. .51 -1'16
' •0 5�/ °} (52.5)
40 1ei00 ./As/ 35` 5
s3° Is
•
FAN VERTICAL BLADE(MANUALi
L
WIRELESS REMOTE •
5cvs • •—•—•—• •
.111111111111111:11111%
��i� 2•141(60) 3.15r1.'y9.51 SWCONTROLLER N 55`
(ARC452A20) Wk.L HOLE;OR STANDARD LOCATIONS OF WALL HOLES WALL HOLE
EMBEDDED PIPING +3-1.8 HOLE
•
40.1..E HOLE
3
•
Daikin AC(Americas),Inc.,1645 Wallace Drive-Suite 110,Carrollton,TX 75006 Page 2 of 4
Daikin AC TRL Generated Submittal Data
www.daikinac.com
(Daikin't products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incunirg any obligations)
L.