Loading...
Report (2) F-P5 20P-I se`' RECEIVED SEP 25 2014 CITY OF TIGARD BUILDING DIVISION SIEMENS Siemens Infrastructure&Cities 15201 NW Greenbrier Pkwy,Suite A4 Beaverton,OR 97006 Phone: (503)207-1900 Fax: (503)207-1901 Siemens Infrastructure&Cities Fire Alarm System Contractor Horizon Realty General Contractor FIRE ALARM SUBMITTAL Washington Square APPLE STORE Suite B09 Siemens Job Number 5200404516 Siemens Project Manager C]Volesky Submittal Version Date Siemens Project Engineer Charles Hughes Issued For Permit/Construction 09.17.2014 Proprietary document for approval only BILL OF MATERIALS SIEMENS Washington Square Apple Store Fire Alarm System Item Part# Qty Mfg Description 1 E50H-24MCW-FW 6 Wheelock Speaker/strobe,Multi-candela,White 2 STW 2 Wheelock Strobe, Multi-candela,White 3 TRI-R 3 Siemens Control Relay 5 PS8 1 Wheelock Power Supply 6 7AH12 2 Werker Battery-7amp hour 12vdc PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 9/17/2014 SIEMENS Fire Safety TRI Series Intelligent Initiating Devices Interface Modules for MXL Fire Detection Panels TRI-S,TRI-D,TRI-R ENGINEER AND ARCHITECT SPECIFICATIONS • Interfaces and Supervises Normally Open Contacts • Integral SPDT Relay (up to 4 amps) onTRl-R Model • Dual Input on TRI-D Model • Multi-color L.E.D. indicates status (green, amber, red) • Easy front access to programming port and wiring terminals • Mounts in 4 inch square 214 deep box, or double gang box .w • Dynamic Supervision ,� WI • Comes with 5x5 inch faceplate • Two wire operation . • Model DPU or FPI-32 Programs and Verifies Device's Address and Tests Device's functionality �+�.,, >� • Electronic Address Programming is Easy and Dependable • 0UL Listed, ULC Listed CFSM, FM, NYMEA Approved Introduction module reports the contact's status to the control The TRI Series Intelligent interface modules are panel. The TRI-S model can only monitor and report the designed to provide the means of interfacing direct status of the contact, while the TRI-R incorporates an shorting devices to the MXL system's ALD loop addressable Form C relay. The TRI-R relay and contact circuit. device input are controlled at the same address. For the MXL system, the relay and input contact can be The TRI Series Intelligent interface modules provide controlled as a separate function. The relay is typically the market's most advanced method of address used where control or shunting of external equipment programming and supervision, combined with sophis- is required. ticated control panel communication. Each TRI Series interface module incorporates a microcomputer chip. The TRI-D is a dual input module and is designed to The TRI Series microcomputer chiptechnologyand itssupervise and monitor two sets of dry contacts.This P sophisticated bi-directional communication capabilities interface module requires two address settings. The with the control panel, achieve the state of an "Intelli- TRI-D is ideal for monitoring a waterflow switch and its gent Device." respective valve tamper switch. The TRI has a multi-color Light Emitting Diode that Description flashes green when operating normally, amber if unit The TRI Series Intelligent interface modules are avail- able in three models. The TRI-S and TRI-R are designed to monitor a normally open dry contact. The interface CATALOG NUMBER 6179 , is in trouble condition, and red to indicate a change of Mounting Data state. The TRI-D flashes twice, once for each address, Addressable interface Model TRI S,TRI D,TRI-R the TRl R red L.E.D. indicates a change of state in mounts directly into a 4 inch square 21/4 deep box the relay. or a double gang box (user supplied). A 5 inch square The device's microcomputer chip has the capacity of off-white faceplate is included with each TRI. storing, in memory, identification information as well • as important operating status information. .t,-; i i t:: i P.:. Siemens BuildingTechnologies, Fire SafetyDivision m€tr t-••- innovative technology allows all TRI Series intelligent interface modules to be programmed by using the model DPU or FPI-32 Programmer/Tester. The Pro- [ `1'f' ���''',:t) I grammer/Tester is a compact, portable, menu driven ' -" accessory that makes programming and testing an TR-s'-7..1:-•=. interface device faster, easier and more dependable f .is ,i i than previous methods. . 3, 0 The DPU or FPI-32 eliminates the need for mechanical �_ ) £� '" �a ' addressing mechanisms, such as program jumpers, .. €' =°PCF: DIP switches or rotary dials, because the Programmer/ = ' Tester electronically sets the TRI interface's address into the interface's microcomputer chip nonvolatile ,-'` f memory. Vibration, corrosion and other conditions that ��`, `` deteriorate mechanical addressing mechanisms are no 7/ longer a cause for concern. w1i"ri_INT IFC,,,,.t:1T`"s The TRI Series is fitted with screw terminals for -oi; ouu_ii c .,N connection to an addressable circuit. D„=/TC H.2 :_ The TRI Series is fully compatible on the same MXL Figure A circuit with all intelligent FP IL and ID-60 Series Mounting the TRI-S/-R/-D detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICP Electrical Ratings - All TRI Series intelligent interface modules are Current Draw (Active or Standby): 1.5mA UL listed. Environmental operating conditions for all TRI Series esiTRI- Relay A,R125s R modules are 32°F (°C) to 120°F (49°C) with a relative Resistive: 4A, 15 VAC humidity of not greater than 93% non-condensating. 4A, 300VDC Inductive: 3.5A, 120 VAC (0.6PF) Ordering Information 0VDC ( 3.0A, 120 VAC0 4PF) Shipping Wt. 2.0A, 120 VAC (0.35P.F) Model Description Lb. Kg. 2.OA, 30 VDC (0.35P.F) TRI-S Single Input 7 oz. .2 TRI-R Single Input w/Relay 7 oz. .2 TRI-D Dual Input 7 oz. .2 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 5.06 Brampton. Ontario Siemens Building Technologies Tel: (973) 593-2600 5M Canada L6T 5E4 9 9IeS FAX: (973) 5936670 SFS-IG Tel: (9051 799-9937 May2006 Fire Safety Website: www.sbt.siemens.comifis Printed in U S A FAX: (905) 799-9858 5upersede5 sheet d3?ed 7/03 COOPER Notification Series E5OH & E6OH High Fidelity Speakers and Speaker Strobes E5OH E6OH E5OH E6OH Speaker Strobes Speakers Description Features The Wheelock Series E5OH Wall and E6OH Ceiling Speakers and • Approvals and Compliance Speaker Strobes are designed for high fidelity sound output for -UL 1971,UL 1480, ULC 5526,ULC 5541 indoor applications. With the widest frequency response range (300 to 8000 Hz) in the industry, the Series EH features leading -California State Fire Marshal(CSFM) intelligibility with crisp, clear voice messages and tone signaling, -ADA/NFPA/ANSI compliant ideal for emergency communications, mass notification, voice evacuation and fire alarm. -Complies with OSHA 29 Part 1910.165 Providing a sleek aesthetic appearance, the wall and ceiling • High fidelity sound output appliances feature dual voltage (25/70 VRMS) capability and -Efficient design for high intelligibility at minimum wattage field-selectable taps from 1/8 to 2 watts. For faster and easier across a frequency range of 300 to 8000 HZ installation,the low profile design incorporates a speaker mounting plate, and each model has a built-in level adjustment feature and • Field Selectable Taps snap-on cover with no visible mounting screws. -25 or 70 VRMS operation For visible signaling to meet the hearing impaired,the Series EH -1/8 watt up to 2 watts Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. • 6 Field Selectable Multi-candela Settings Strobe options for wall mount models include 1575 or Wheelock -Wall mount models are available with Field Selectable patented MCW multi-candela strobe with field selectable candela Candela Settings of 15/30/75/110cd or 135/185cd settings of 15/30/75/110cd or the high intensity MCWH strobe with (Multi-Candela models)or 1575cd(Single Candela field selectable 135/185cd. model) Ceiling mount models are available in Wheelock patented MCC -Ceiling mount models are available with field multi-candela ceiling strobe with field selectable intensities of selectable candela settings of 15/30/75/95cd or 15/30/75/95cd or the high intensity MCCH strobe with field 115/177cd(Multi-candela models) selectable 115/177cd. • The strobe portion of all Series EH Speaker Strobes may be Mounting synchronized when used in conjunction with the Wheelock DSM -Low profile design incorporates speaker mounting plate Sync Modules,Wheelock Power Supplies or other manufacturers for faster and easier installation panels incorporating the Wheelock Patented Sync Protocol. -Snap on grille cover with no visible mounting screws Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. -Quick installation with IN/OUT screw terminals using#12 Series EH Speaker Strobes are UL Listed for indoor use under to#18 AWG wires Standard 1971 (Signaling Devices for the Hearing-Impaired) and -4"square backbox prevents wire damage Standard 1480(Speaker Appliances),and ULC listed under CAN/ -Series E5OH-No extension ring required ULC-S526(Visual-audible Signal Appliances,Fire Alarm)and under CAN/ULC-S541 (Speakers,Fire Alarm). All inputs employ IN/OUT -Series E6OH-Optional Extender(E60 Ext)is available for wiring terminals for fast installation using#12 to#18 AWG wiring. mounting to 4"square backboxes Color options for the Series EH Speakers and Speaker Strobes • Compatibility and Requirements are red and white. -Strobes produce 1 flash per second over the regulated voltage range • -24 VDC with wide UL"Regulated Voltage"using filtered DC or unfiltered VRMS input voltage -Synchronize with Wheelock DSM,Wheelock Power Supplies or other manufacturers panels, incorporating °'F the Wheelock Patented Sync Protocol NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS • INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate • of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Table 1: Maximum RMS Current-Series E5OH Table 2: Average RMS Current-Series E6OH E5OH Strobe Current-Wall Mount E6OH Strobe Current-Ceiling Mount E5OH E6OH Speaker 24MCW 24MCWH 241575W Speaker 24MCC 24MCCH Strobes - Strobes • 15cd 30cd 75cd 110cd 135cd 185cd 15/75cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 vdc 0.060 0.092 0.165 0.220 0.300 0.420 0.090 16-33 vdc 0.065 0.105 0.189 0.249 0.300 0.420 Table 3: EH UL Reverberant dBA @ 10 Feet** Watts 1/8*** 1/4 1/2 1 2 E5OH Speaker/ 73 76 79 82 84 Speaker Strobe E6OH Speaker 74 77 80 83 85 E6OH Speaker Strobe 74 77 80 82 85 *RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. **dBA ratings are based on testing under UL Standard 1480. ***1/8 watt tap is for private mode only. Speaker/Speaker Strobe Diagrams with Dimensions 5.00 _.� 5.00 P ' .fi_ 00o 000 05:0So 5.00 ri oogg�ofiI °• 0o°D. I'�I'1_ INN"MY 119 E5OH Speaker E5OH Speaker Strobe .522 2 WEoo T MgAggidli �'oeoOo oo�soo ii" ' �i' • o�oo^00000=�/° 41€1. 111:11, E6OH Speaker E6OH Speaker Strobe Wiring Diagrams" SERIES EH SPEAKER&STROBE OPERATE SERIES EH SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY(NON-SYNC OR SYNC) WITH MULTIPLE DSM MODULES P ROM TO NEXT Audi•I r NA i DSM 1V7 Note: Figure PRECEDING �- + APPLIANCE Strobe NAC Cir. Syn■m+c ©� ©� shows intercon- APPLIANCECE _ OR VOICE - OR EOLR F vection to strobe EVACUATION 'DSM 42 through$ nc PANEL TO NEXE Audible NAC Or 9 Y PROM .+ _ —— A '�sync module. Speaker • PRECEDING r — STROBE Strobe NAC Cr,. ' IMO P SIROBE,SYNC - -— 11 —— ——— - OR • t IN portion requires 2 MODULE, EOLR p DSM 3 POWER _ separate Gond - U Audible NAC Cu UC P OR P �•I Sync tors to FACP. ERCP 0 Strobe NAC Cir. : 1031110 STROBE SPEAKER DSM Interconnecting wiring shown.Maximum of twenty(20) SERIES EH SPEAKER STROBE APPLIANCES SERIES EH SPEAKER STROBE APPLIANCES&RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WHEELOCK POWER CLASS"A" DSM SUPPLIES Series PS Power Supplies STROBE ,--1 + NAC SYNC 0 CIRCUIT e E I OUT // • OUTPUTSJKI ® EOLR ' 4-CLASS MINUS 1�_ „ OR E �/ _ Mil AUDIBLE 2-CLASS MINUS] •A” �J CP STROBE ,/+INS II I ©�©E.IM NAC /+OUT 2 / CIRCUIT E (\\ RETURN Series PS Power Supplies_J For wiring information on the Wheelock power supplies, please refer to Data Sheet#S9100. A For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84905. Specifications and Ordering Information Strobe Sync w/ Agency Order Wall Ceiling Non- DSM or Strobe Model Model Mounting Op- Approvals Model Code Mount Mount Sync Wheelock Power Candela Color Color tions Supplies Red White UL ULC CSFM • E50H-R 9863 X X - - - X E,AA X X X E50H-W 9864 X X - - - X E,AA X X X E50H-24MCW-FR 0092 X - X X 15/30/75/110 X E,BB X X X E50H-24MCW-FW 0093 X - X X 15/30/75/110 X E,BB X X X E50H-24MCWH-FR 0094 X - X X 135/185 X E,BB X X X E50H-24MCWH-FW 0097 X - X X 135/185 X E,BB X X X E50H-241575W-FR X X X 15/75 X E,BB X X X E50H-241575W-FW X X X 15/75 X E,BB X X X E60H-R 9867 X - - - X - E X X X E60H-W 9874 X - - - - X E X X X E60H-24MCC-FR 0187 - X X X 15/30/75/95 X - E X X X E60H-24MCC-FW 0188 - X X X 15/30/75/95 - X E X X X E60H-24MCCH-FR 0189 - X X X 115/177 X - E X X X E60H-24MCCH-FW 0190 - X X X 115/177 - X E X X X E60EXT-R ' 3578 X X - E60EXT-W`*` 3757 X X - • ***E60 EXT is an attractive extender ring that mounts behind the speaker to permit mounting to a 4"square x 2 1/8"deep electrical box without need for an extension ring on the box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in • accordance with Wheelock Inc.standard terms and conditions. • Architects and Engineers Specifications Wheelock Series E5OH The speaker appliances shall be Wheelock Series E5OH High Fidelity Speakers,and the High Fidelity Speaker Strobe appliances shall be Wheelock Series E5OH Speaker Strobes or approved equals.The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing-Impaired.In addition, the strobes shall be certified to meet the requirements of FCC Part 15,Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dBA at 10 feet and a listed frequency response of 300 to 8000 Hz.The speaker ' shall incorporate a sealed back construction. All inputs shall employ terminals that accept#12 to#18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall be of low current design.Where Multi-Candela Speaker Strobes are specified,the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/110cd or 135/185cd for wall mounting. Models with 1575 candela shall also be offered for wall- mount applications.The selector switch for selecting the candela shall be tamper resistant. When synchronization is required,the strobe portion of the appliance shall be compatible with the Wheelock's DSM sync modules or Wheelock Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate,(i.e.,contacts remain closed),the strobe shall revert to a non- synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting to 4"x 2-1/8"electrical boxes without need for an extension ring or surface mounting to Wheelock's E5OSB or E5OSSB surface boxes.The speaker and speaker strobe shall incorporate a speaker mounting plate with a snap-on grille cover.The finish of the Series E5OH speakers and speakers strobes shall be white or red. UL 1971, UL 1480, ULC-S526, ULC-S541, CSFM, FCC. Wheelock Series E6OH The speaker appliances shall be Wheelock Series E6OH High Fidelity Speakers,and the High Fidelity Speaker Strobe appliances shall be Wheelock Series E6OH Speaker Strobes or approved equals.The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing-Impaired.In addition, the strobes shall be certified to meet the requirements of FCC Part 15,Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 300 to 8000 Hz. The speaker shall also incorporate a sealed back construction.All inputs shall employ terminals that accept#12 to#18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range.The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. • When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules or the Wheelock Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e.,contacts remain closed),the strobe shall revert to a non- synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a snap-on grille cover with no visible screws for a level, aesthetic finish and shall mount to standard electrical hardware. The finish of the Series E6OH Speakers and Speaker Strobes shall be white or red. All speaker and speaker strobe appliances shall be backward compatible. UL 1971, UL 1480, ULC-S526, ULC-S541,CSFM, FCC. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY E5OH/E6OH 9/12 - NJ Location FL Location VA Location 273 Branchport Ave. 7246 16th Street E,Unit 105 103 West Broad Street,Suite 500 Long Branch, NJ 07740 Sarasota FL 34243-6817 Falls Church,VA 22046 P:800-631-2148 P:941-487-2300 P: 877-459-7726 • F:732-222-8707 F: 941-487-2389 F:703-294-6560 www.coopernotification.com / Cooper Notification is Wheelock° SAFEPATH WAVES, COOPER Notification UL Listed Product Range 00 COOPER Safety Fire Systems arinermon • S,GNALING C Internal Strobes LISTED SACS ETRE ALARM PMENT oF*4, '', '')'*:„,-, :4;:ei--. ..,., �. ., FIRE , IRE , , - v fX 411, ;" \ , .-P ,,, \ „,,,- STWC-Ceiling Mounted/STR-Wall Mounted at' Overview Features The ceiling mounted(STWC)and wall mounted • Wall or ceiling mounting (STR)internal strobes are designed to exceed, • options your expectations and offer the most polished • Common mounting base cover i feature rich and cost effective solution. • Contact Industry's highest strobe ° candela options Both the(STWC)and the(STR)are compatible • Field selectable tone,dBA with the Cooper UL Listed range of intelligent and candela settings addressable fire systems. In;out wiring termination „,' accepting two#12-18 AWG Architects and engineers can now specify the wires at each terminal i[f' it industries sleekest looking fire notification appliance,while being afforded all the features Benefits ” . ' and benefits that provide the industry's lowest total cost of ownership. • Quick and simple to install � • Up to 48%savings in " _ 1 ?a? The combination of 12V dc and 24V dc in one current draw(over similar unit provides the capability to use a single unit products) for different installation requirements. • lgpor troubleshootingVotaetestoints andfeasyquick i4 1 These units use a universal,common mounting spot checking base making them ideal for retrofit jobs,limited Contact cover provides space environments and pre-existing wire protection from dirt,dust, configurations. paint and accidental damage,it also allows for They come complete with a contact cover for pre-wire testing and protection against dirt,dust,paint and damage troubleshooting to the contacts.This contact cover also acts as a shunting device to allow pre-wire testing for common wiring issues. COOPER31 • UL Internal Strobes - STWC /STR ■...Me.n.. • Dimensions - Wall Mount Technical Specification H(mm) W(mm) D(mm) Code STR STWC 113 116 56 p[Des,s cam. imernal Strobes,Wall Mounted _... 1 inter-.al Strobes Ceiling C_u:tea Standards I UL S artlard 1571 UL Standard 10 71 Operation ROM I 2 ,. 124Vda 'vs3c .•,. s 10.:3, 85 cd ., I L„1_, 307osst 9135;165 rad -'— Environmental _- Operating len•peralure 0"C lc 49"C C'C to 49'C Humidity Non Conden.singj... a to 93°SRH 1 0 to 93 S%Rid Compatibility Dimensions - Ceiling Mount <;t b ,.a With Cooper UL Flre Systems 000peL Systems -- � Dia(mm) D(mm) Current Draw Ratings /.': w-----\ 166 34 (' t 1 r Strobe ratings per UL standard 1971 UI Mae Current' �/i ]] 24V dd 7V7 do �` Mode Requlatee Voltage Range 15 f 15.75 31 1 60 75 95 110 115 135 150 177 185 15 7.P5 ST 8 OV do to 33 CV do 0 0 71 0.070,,0085i 3 35 0173 5 152 0205 0253 0.115 i0 140 STC 9 O do to 33.07 do 0 061, 0.0850 103 3 135,0.1631 5.18_ 0.2050.253 0 1101 Ell..max current rating is t':e maximum RMS current unl;::n tire listed voltage range(16-337 no for 247 do units).F o n:robes Meiji. 9 a. t y the minimum 't d hate 0167 do for 47 dc , Fora the man cement is usually at":e maximum Standard Connection s d c , 247 dounits)Foe._filtesev ratings,r installation ,„ation. MN -• Internal Strobe Unit Details Eros preceed,9 .. 10 neat appleroa or ahnliarrr o: .,.,c of dile resistor Tone Selection Tore Selection dosipil Ps^.el ;LOLAi l 10 01_ mr.. "�A Candele � ♦((��((��'j — li Selection I / • WARNING, �x ;�p-tllliJ .� ti'�(1{l, • ` 7�` li �\\ Cand e Do NOT use high voltage testers it ANY equipment is Selection�., Lir L + I._ connected to the system. G FIRE I i Screen(Earth)must be continuous along entire length of cable �:y 1- \ -- ��l,.I {- Candela \�iI,I8.1►y. i 7- dele Wiring method shall be in accordance with CSA C22.1, ��' '��i Window �1 a Window Canadian Electrical Code,Part 1,Safety Standard for Electrical Installations,Section 32. • • • 1. All strobe appliances have in-out wiring terminals that accept two 812 to#18 American Wire Gauge(AWG)wires at each screw terminal.Strip leads 3/8 inches • I and connect to screw terminals. ll II 2. Break all in-out wire runs on supervised circuits to ensure integrity of circuit supervision.The polarity shown in the wiring diagrams is for the operation of the appliances.The poiadty is reversed by the control panel during supervision, Horns,Strobes and Horn Strobes :so-obe ,,,_a -ear-, ..il, _ - t t: _ :.cf r :i M n ?ion PiestardLe LelPie v Py ,. t.se _-',le to a14F 11_^ol L Product Codes Code Description STR Internal Strobes;Wall Mount STWC Internal Strobes,Ceiling Mount 32 COOPER Notification POWERPATHT" NAC POWER SUPPLIES PS-EXP PS-6 PS-8 Description The Wheelock Series PS-6 and PS-8 are 24VDC, filtered and The PS-6 and P5-8 Power Supplies are UL Listed under UL regulated, supervised remote power supply/battery chargers are Standard 864, 9th Edition to be used with any 24 volt Listed used for supervision and expanded power driving capability of Fire Regulated notification appliances.They include the capability Alarm Notification Appliance Circuits. The PS-6 provides 6 amps of to synchronize Wheelock strobes and horns and to silence the power distributed across 4 outputs,while the PS-8 provides 8 Amps horn signal when horn/strobes are operating on two wires. across 4 output. In addition the PS-8 provides additional room in the chassis for accessories like an Addressable Control Module, with mounting studs. Approvals The Power Supplies may be connected to any 12V or 24V (FWR or 'Approvals Include:UL Standard 864,1481,California State DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance Fire Marshal(CSFM), Factory Mutual(FM) Circuit (NAC) or a "Dry Contact". Primary applications include NAC •Compliant with NFPA 72 expansion (supports ADA requirements) and auxiliary power to support system accessories.This unit provides filtered and regulated Inputs 24VDC, up to four (4) Class "B", two (2) Class "A", or two (2) Class •120VAC,50/60Hz,4.25 Amps(PS-6/8)and 5.32 Amps "B"and one (1) Class "A"Notification Appliance Circuits. With the (PS-8)Operating Power in Alarm • optional plug-in PS-EXP module the unit supports (8) Class "B"or •240VAC,60Hz,2.42 Amps(PS-6E and 3.22 Amps(PS-8E)' (4) Class"A"Notification Appliance Circuits. Additionally, an auxiliary Operating Power in Alarm power output of 2.5 Amps (disconnected upon AC power loss or an 24VDC Battery Backup Connection alarm condition) or up to 0.240 A of constant power on the PS-8 and .Two(2),12V or 24V NAC Initiating Circuits(8-33V at 5mA) 0.075 A of constant power on the P5-6. FWR or DC The Wheelock Power Supplies can accommodate 7 or 12 AH batteries •Two(2)"Dry"Contact initiating Circuits inside its lockable chassis. Using an external battery cabinet it can •Accepts two(2)Class"A"or two(2)Class"B"circuit inputs charge up to 33 AH batteries (pending UL testing). Two FACP NAC Built in battery charger for sealed lead acid or gel type circuits or two"Dry"contact initiating circuits can be connected to the inputs.These inputs can then be directed to control supervision and batteries power delivery to any combination of the four(4)outputs.Each output is rated at 3.0 Amps (Class"B") or(Class"A") and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe Outputs output under alarm condition.Total load for the PS-6 and PS-8 NAC •NAC outputs are 24VDC,3.0 Amps each,power limited circuits must not exceed the power supplies rated output. •8 Amps on PS-8 and 6 Amps on the PS-6 total alarm current The Power Suppliesunder non-alarm condition provides independent supervision for Class 'A"and Class "B" FACP NAC circuits. In the event of circuit trouble,the FACP will be notified via the POWERPATH steered input (IN1 or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles.The AC power loss reporting, on the common trouble terminals and on IN1 or IN2, can be delayed for either 30 • seconds or 170 minutes.The AC power loss terminals will always report the trouble within 1 second after loss of AC power. 41/1) q6rAi>' l; APPROVED ...Features continued on next page • •Capable of four(4),Class"B"circuits •Capable of two(2)Class"A"circuits •Capable of one(1)Class"A"circuit and two(2)Class"B"circuits •Capable of(8)Class"B"or four(4)Class"A"circuits with optional PS-EXP module •Temporal(Code 3),constant voltage output,Wheelock Sync output or True input to output follower mode •Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits •Input and output can be synchronized with"IN>OUT SYNC"mode(DSM,2nd POWERPATHT"or FACP with synchronization protocol is required) •Audible silence capability •Filtered and electronically regulated output •2.5 Amp auxiliary power limited output with reset capability.(Removed upon AC loss or alarm.Automatic reset 30 seconds after AC power returns or the alarm condition is over)or 0.075 Amps(PS-6)or 0.240 Amps(PS-8)of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision •Compatible with 12V or 24V(FWR or DC)FACP •Signaling appliance circuits are supervised and steered to either IN1 or IN2 •10K Ohm,1 Watt(Wheelock Model#MPEOL)End of Line Resistor(EOLR)for supervision of all outputs •37 distinguishable trouble diagnostics •AC loss trouble reported over a separate set of contacts(delay of 1 second) •All troubles are reported over thetroublecontacts A p common c c s{ C loss can have a delay of 30 seconds or 170 minutes) •Automatic switchover to standby battery when AC fails •Thermal and short circuit protection with auto reset •Input and output status LED indicators •AC fail supervision •Battery presence and low battery supervision •Ground Fault Detection,with diagnostics to indicate which circuit fault is on •Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's(latching can be disabled) Power •Not Battery Dependent •Automatic switch over to standby batteries when AC fails •Supports sealed lead acid or gel type batteries •Fused battery protection •Thermal and short circuit protection with auto reset •Supports both 7AH or 12AH batteries in the same cabinet POWERPATH"Operating Modes(refer to Installation Manual): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input IN1 or IN2 or by a contact opening on DRY1 or DRY2.The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances.Audibles can also be silenced in this mode while the strobes continue to flash. In>Out Sync Mode:Accepts a synchronization signal on the input to provide a coded output or synchronized output.This signal may come from a FACP,another POWERPATH or a Wheelock DSM synchronization module.Caution:Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACP, another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible appliances such as horns, bells or chimes.Caution:Do not use strobes on coded output circuits. Specifications and Ordering Information Model Number Order Input Voltage/Current Approvals Code UL CSFM FM PS-6 105530 6 amp,red enclosure X X X PS-6B 100257 6 amp,black enclosure X X X PS-8 105531 8 amp,red enclosure X X X PS-8B 105830 8 amp,black enclosure X X X PS-6EXP 105083 6 amp power supply with preinstalled expansion module X X X PS-8EXP 105084 8 amp power supply with preinstalled expansion module X X X PS-EXP 105534 4 class B or 2 class A expansion module X X X PS-EXP-RETRO 105527 Field upgrade kit for models prior to January 2010- X X X Input Circuit Input Voltage and Current X=Approved Input voltage Range 8 to 33 VDC *=Pending Input Current @ 12 VDC 0.005 amps #=Contact Technical Support for additional Input Current @ 24 VDC 0.005 amps inforamation on upgrade Output Circuit Output Voltage and Current options Four(4)Class B or Two(2)Class A or One(1)Class A and Two(2)Class"B"or 24 VDC @ up to 3 amps per curcuit 8 Class B or 4 Class A (optional PS-EXP module necessary) Continuous duty up to 3 Amps per circuit,up to 4 Amps maximum per panel Standby Current 0.129 Amps Alarm Current 0.129 Amps Primary PS-6(120 VAC models) 105 to 130 VAC,50/60 Hz @ 4.25 Amps Primary PS-8(120VAC models) 105 to 130 VAC 50/60 Hz @ 5.32 Amps Primary PS-6E(240 VAC models) 210 to 260 VAC,50/60 Hz @ 2.42 Amps Primary PS-8E(240 VAC models) 210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @ 0.750 Amps per hour Enclosure can house up to two 12 AH batteries Aux Output CP Mode P5-6 up to 75 mA P5-8 up to 250 mA MP Mode 2.5A during non alarm Model Dimensions Weight Comments PS-6/PS-6B 17"H x 13"W x 3.5"D 11.51bs.(Ship)9.4lbs(Unit) Small profile PS-8/PS-8B 17"H x 15"W x 5.5"D 17.71bs(Ship)15.61bs(Unit) Additional room for modules PS-EXP 4.3"H x 3.7"W x 1"D 11b.(Ship&Unit) Plugs into main pcb on all models • • Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH" Series PS-8, or equivalent.The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC).The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70(NEC),article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact"opening.The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR.The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions.The power supply shall provide four Class"B", two Class"A", or two Class"B"and one Class"A"NAC circuit(s). Eight Class"B"or Four Class"A"circuits shall be available with an optional PS-EXP module.The PS-8 unit shall supply up to 240 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures.These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class"B" applications or 3 amperes each for Class"A':The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output.The power supply shall provide independent loop supervision for either Class"A"or Class "B"FACP NAC circuits and shall have the capability to"steer"all alarm or trouble conditions to either incoming NAC circuit.The units shall have common trouble terminals.The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max.The unit shall incorporate short circuit protection with auto reset.The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure.The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max.The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified.The cabinet dimensions shall be 17"H x 15"W x 5.5"D. The power supply shall be Wheelock POWERPATH" Series PS-6, or equivalent.The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC).The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70(NEC),article 760. The power supply shall support a full 6A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact"opening.The units shall be 6 ampere, 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 8 to 33 VDC or FWR.The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions.The power supply shall provide four Class"B" two Class"A, or two Class "B"and one Class "A" NAC circuit(s). Eight Class"B"or Four Class"A"circuits shall be available with an optional PS-EXP module.The P5-6 unit shall supply up to 200 mA of auxiliary power that is available during both non-alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non-alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at a maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures.These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class"B" applications or 3 amperes each for Class"A':The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output.The power supply shall provide independent loop supervision for either Class"A"or Class "B"FACP NAC circuits and shall have the capability to"steer"all alarm or trouble conditions to either incoming NAC circuit.The units shall have common trouble terminals.The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max.The unit shall incorporate short circuit protection with auto reset.The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure.The charger shall incorporate fused protection for the batteries and have the ability to report low battery and/or no battery condition(s). Standby current for battery back up shall be 0.130 Amps max.The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified.The cabinet dimensions shall be 17"H x 13"W x 3.5"D. AWARNING:PLEASE READTHESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLA- TION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accor- dance with Wheelock Inc.standard terms and conditions. or RA Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY ,S9100 PS-6&8 06/11 NJ Location 273 Branch port Ave. Long Branch,NJ 07740 • P:800-631-2148 F:732-222-8707 www.coopernotification.com Cooper Notification is Wheelock"(max) SAFEPATH. WAVE COOPER Notification Jobsite Information: WSQ TA Block B FAPS LOCATION:MF77 LEVEL ABOVE SECURITY Battery Calculations for FAPS (Model PS-8) Total Standby Load Number Current Total Current Device/Circuit Type (Amps) _ (Amps) PS-8 Internal Current Draw 1 X 0.129 = 0.129 Number of Remote Units on Sync. Bus(Multiply by 0.006 for each 0 X 0.006 = 0 remote unit) Auxiliary Current Draw X 0 = 0 (From Auxiliary Power Output) STANDBY LOAD = f 0.129 Total Alarm Load Number Current Total Current Device/Circuit Type (Amps) (Amps) PS-8 Internal Current Draw 1 X 0.129 = 0.129 Auxiliary Current Draw X = 0 (From Auxiliary Power Output) NAC/Output#1 (Circuit load) 1 X 0.68 = 0.68 CKT#N5-1-roc NAC/Output#2(Circuit load) 1 X 0 = 0 CKT#N5-2-io NAC/Output#3(Circuit load) 1 X 0 = 0 CKT#N5-3-xi NAC/Output#4 1 X 0 = 0 • CKT#N5-4-roc ALARM LOAD = 0.809 Battery Capacity Calculations in AH (Ampere Hours) Standby Load Required Standby Time Current(Amps) (Typically 24 Hours) 0.129 X 24 = 3.096 AH Alarm Load Required Alarm Time Current(Amps) (Typically 15 Minutes For Fire EVAC. Systems) 0.809 X 15 = 0.20 AH Sub Total Standby/Alarm Amp Hours 3.30 AH Multiply by the Derating Factor X 1.2 * Total Ampere Hours Required = 4 AH Battery Capacity Supplied = 8 AH *Derating Factor required to compensate for the non-linear discharge characteristic of a battery. The PS-8 will fit(2) 12 VDC/12 AH batteries.