ReportP s i i .., aA, r7 ' a . ,, _ aes-coirp.com ` CORPORATION '""Q kM '%Y a 1 Technical Specifications Integrated Fire Monitoring System D8 M 2NH SIONS x14-1/4"W x 4-3/4"D 7706-U L F f** (46.9 cm H x 36.1 cm W x 12.1 cm D) WEIGHT Approximately 17 pounds(8 kilograms), excludes battery " CABINET COLOR sg�lelliN� fd'�w'"'B Red Features AC POWER INPUT • UL listed and NFPA compliant 120VAC 60Hz 1.0 AMP • A compact intelligent FACP BACKUP BATTERY • 6 Programmable Zone Inputs Enclosure capacity for two 14AH g p batteries. Will charge up to two 18 AH • 1 Notification Appliance Circuit(NAC)with strobe synchronization batteries.Sealed lead acid batteries- requires 2 each 12 VDC UL recognized. • NAC supports all major synchronization patterns • Power Supply charges up to (2) 18AH batteries, providing power to meet ANTENNA any jurisdiction's requirements Supplied 2.5 dB tamper resistant enclosure mount antenna.Optional • Supports Potter RA-6075 Remote Annunciator via the P-Link bus remote mounting antennas available. • Red metal enclosure with a key lock and Lexan window for viewing the COMPATIBLE RECEIVER system status 7705i AES-MultiNet • 32(2 x 16) character LCD display with system LEDs for clear system status- ALARM SIGNAL INPUTS • Keypad for access to the system , 6 Programmable Initiating Device Circuits • Easy configuration with Programming trfriviroft TIGARD 1 input -Type A(four wire)or Type B input(two wire) • Cabinet mounted subscri i lam %commettax 5 inputs-Type B • Email notification capability r sen•i ., sy e s , reports, system SMOKE DETECTOR COMPATIBILITY configuration, or service re OT-1 ' 2-sag Compatible with a large number of - listed 2 wire models including: Benefits Permit 6 20 v System Senors Detection Systems Addrei `7( ,/'I ! iMAir� ESL Hochiki • Highly integrated turnkey si$ Ibim •ol • + Fenwal Potter • Ideally suited for small torril Izeinsti 1• NAC OUTPUT • Innovative solution Ieveragin A ''�� � ,. • mesh r..'. "' Compatible with a large number of technology and Potter proven FACP listed 2 wire models including: • High speed communication between AES subscriber andanel eliminates Amseco Gentex need for DACT OFFICE COPY Potter/Gentex Eaton • AES subscriber provides primary communications path Cooper Wheelock System Sensor • No telephone lines are required ' NAC PATTERNS • Easy installation saves time and lowers cost of deployment Temporal&Cadence patterns • Simple and flexible single point configuration 'VISUAL INDICATORS • Provides fast alarm communication and reporting to the Central Monitoring Station LCD(2 x 16 Alphanumeric Character • Streamlines AHJ approval process reducing installation time and deployment cost Display) LED indicators-Control Panel and • The AES Corporation global service and technical support team is available 24/7 Subscriber as single point of contact Technical Specifications(continued) Overview CONFIGURATION INTERFACE The AES Corporation model 7706-ULF was engineered in close collaboration with Keypad with function,number and navigation keys Potter Electric Signal Co., designed specifically for small to mid-size fire protection applications. The 7706-ULF is a single-box integrated solution, bringing together ALARM SYSTEM PROGRAMMING AES-IntelliNet® patented alarm communications technology and Potter's proven INTERFACE Ethernet using programming software Fire Alarm Control Panel (FACP)for life safety. SUBSCRIBER PROGRAMMING The AES 7706-ULF Integrated Fire Monitoring System is a compact, simple panel INTERFACE designed to monitor and communicate the alarm status to a Central Monitoring Control Panel LCD and keypad Station.The 7706-ULF system is a listed and approved microprocessor-based fire UL STANDARDS monitoring panel and complies with UL-864 requirements as well as NFPA-70 and Meets UL-864 9th Edition-Standard NFPA- 72 National Fire Alarm and Signaling Code.The panel features 6 Inputs and for Control Units and Accessories for Fire Alarm Systems one 24 VDC 0.5A Notification Appliance Circuit(NAC)with strobe synchronization. The 2.0A Power Supply provides ample power to meet any jurisdiction's requirements, OPERATING TEMPERATURE RANGE 0°to 49°C(32°to 120°F) also has capacity to charge up to(2) 18AH batteries. In addition,the panel includes the Potter Signal P-Link for connection to a remote annunciator. STORAGE TEMPERATURE RANGE -10°to 60°C(14°to 140°F) The Panel Interface Card,jointly developed by AES and Potter, provides a high-speed RELATIVE HUMIDITY RANGE bi-directional communications interface between the fire control panel and the 0 to 93%RHC,Non Condensing AES 7788F subscriber.This allows alarm and status messages generated by the panel to be sent directly to the subscriber for transmission on the AES private wireless About AES Corporation network. It also allows the panel to supervise the subscriber status to annunciate local AE5 Corporation is the leading manufacturer of code compliant trouble if the subscriber is not functioning correctly. wireless alarm communication Alarm signals, supervisory and trouble messages are transmitted through the products and solutions serving commercial security markets and AES 7788F Fire subscriber built into the panel enclosure.The panel zone input government agencies worldwide. configuration is done with the Potter Signal panel configuration software over the AES-Inte!IiNetepatented TCP/IP network access port. The 7706-ULF keypad interface provides access to the technology will never sunset AES subscriber for configuration and status information. compared to obsoleting technologies such as cellular The AES 7706-ULF provides the Central Monitoring Station capability to quickly and traditional phone lines.AES detect any alarm condition.This is a complete departure from the use of traditional private mesh radio networks are phone lines, providing a high speed link between the alarm panel and the AES Smart owner operated and controlled, providing infinite scalability and Subscriber.This link is always active and always supervised on both sides.The superior reliability with the fastest 7706-ULF with the built-in AES 7788F Smart Subscriber provides end-to-end agility transmission speed available.Over and a fault tolerant system. a half million AES Smart Subscribers are installed worldwide.AES is When it comes to preventing loss of life or property, network owners and operators as the clear choice for life safety and well as first responders rely on AES-IntelliNet®global alarm communications technology. security, protecting people and property for over 40 years. How to Order 7706-ULF 7706-ULF Integrated Fire Monitoring System wpm ®POUER �] S �...S. -I t ) NetOrle' rheSymodorvrote .,.. tion NFPA° GSA � o ...„..,W..,.«... -i For more information, go to Cal! or contact us at Copyright 2015 AES Corporation AES-AueUuVeu is a registered trademark of AES Corporation CONVENTIONAL FIRE CONTROL PANEL ACCESSORY 4% SILENT PS-DA and PS-SA iik KNIGHT Conventional Pull-stations by Honeywell Easy to Install and Operate The PS-DAPS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP)with a single alarm initiating input signal. The PS-DAPS-SA pull stations includes both single-action and dual-action models equipped with key lock/reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS-SA simple to install, maintain, and operate. 1 Operation F .IRE4 The single-action pull-station is er`EG /FIRE activated by a single pull-down of r tt� 1� the alarm handle. The dual-action t►ACTIVATED 4) EMPUJEY versions require pushing in the PUSH IN handle, then pulling the handle HALPU ��DOWN Jo down for activation. The PS- I PUSH IN I DAPS-SA manual pull stations are PULL DOWN UL listed and meet the ADA requirement of a 5-lbs. maximum `.,, %°""'"'"""................ 1pull force to activate. Operating instructions are molded into the �u_i:\r �',. SILENT handle along with Braille text. gi KNIGHT , ,,, kNic,trr ti �4 Molded terminal numbers can be " o 0 found adjacent to the wiring termi- 1 nals. Models: PS-DA PS-DASP PS-SA—Single action with 'pigtail' Features: Specification: connections and a key lock reset. • UL Listed Dimensions: Pigtail wires are provided for con- • CSFM Listed Height: 5-1/2"(13.97 cm) nection to the Fire Alarm Control Width: 4"(10.16 cm) Panel's (FACP) initiation circuit. • Meets ADA requirements Depth: 1-7/16"(3.65 cm) • Operating instructions are mold- Operating PS-DA—Dual action model with ed into the handle along with temperature: 32°F to 120°F screw terminal connections and a Braille text. (0°C to 49°C) key lock reset. • Made of durable LexanSwElectrical: PS-DAH—Same as PS-DA except tch Contact p Available in Spanish Rating: 0.25 A @ 30 VAC with hex lock reset. • Key resettable or VDC PS-DALOB—Same as PS-DA with • Easy to Install and operate Accessories: "outdoor use" listing. Includes SB- • Single or dual action Surface I/O backbox and sealing gasket. • Surface mount box available SB-I/O Back-boMount x PS-DASP—Same as PS-DA BG-TR Trim Ring except with both English and Spanish operating instructions. COM,ENTIONAL FIRE CONTROL PANEL ACCESSORY • PS-DA and PS-SA Conventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN®(or polycarbonate equivalent)with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back-box SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act(ADA)or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO"on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. +- FIRE FIRE - _ _ _ , � _ I 1 2 3 4 i • . ... (f AACTIVATED u 1PULL DOWN + — I jPUSH IN PULL DOWN + 1......•••••••""'"°°1 _ . h\Ball .,, Q h\1GtiT ,', o 171 1 1 PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View for installation purposes.Weto MADE IN AMERICA SILENT This document is not intended to be used o s p ptry `j KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are sub- P/N 350241 Rev.D • ject to change without notice.For more information,contact Silent Knight 12 ©2011 Honeywell International Inc. by Honeywell Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.www.silentknight.com SYSTEM �� • SENSOR b,d } . Photoelectric Smoke Detectors System Sensor i3M •series smoke detectors represent r significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The P line redefines installation ease with its •Plugin detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Builtin remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings T O) 43 ® MEA MSFM LISTED APPROVED I approved approved us S911 3011446 7272-1653:152 290-01-5 2093 3180932 (u Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (572°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20mA@12V,23mA@24V 4WT-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Fmdu s 02009 System sensor SENSOR" �a =foram mice onmt eem for Phone:800-SENSOR2•Fax:630 377 6495 current �amatan 18-007.6/09.12 esmormndata sheet A05-031 BO07.6/09•X2169 t �� SYSTElVi �' SENSOR' .. Ri Indoor Selectable- _ ,,, Output Horns, ��,-t Strobes, and .: ; `j : Horn Strobes for _ :;‘,0 #`• 1 Wall Applications ?L SpectrAlerlo Advance audible visible notification products SPECTFIAlert are rich with features guaranteed to cut installation times tfitiargar A NI c and maximize profits. Features The SpectrAlert Advance series offers the most versatile and Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. • With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela • Field selectable candela settings on wall units: 15, 15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, 30,75,95, 110, 115, 135, 150, 177,and 185 strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ® ® MEA ' LISTED APPROVED approved 7125-1653 186(nectar strobes) 7125-1653 188(porn strobes, 54011(chimes,horn strobes.horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653.189(horns.chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General 1 • SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts:24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. r - UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts • Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 - Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) ' 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 ' 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 ' 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. • • SpectrAlert Advance Dimensions =� 4.7 2.5 till WM Mir I II 5.6" 11117) - ♦ ..-- Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135, 150, 177,and 185 candela settings. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 a2o14 Systemsensor. Phone:800-SENSOR2•Fax:630-377-6495 Product specilcations suoGa to change without notice.Visit systemsensor.com SENSOR° www.s Ystemsensor.com for current product Intormaton,Including the latest version ot tnis data sheet. AVDS10201.1/14 8 POTTER Project Name: COMMERCE PLAZA Standby Hours: 24 The Symbol of Protection Alarm Mins: 5 _ PFC-6006 Installed By: WESTERN STATES FIRE Batt Efficiency: 80% Battery& Voltage Drop Designed By: DAVE KELLER SIC Type: Class B Calculations Date: 2/1/2016 NAC Source Voltage: 20.4 Model#: PFC-6006 Max Panel Current(amps): 2 Panel ID: 145 Qum User assumes all responsibility to ensure the quantities and Location �%po a- pc current draw values in this worksheet are accurate prior to submittal. FACP Standby(amps) Alarm(amps) Qty Part# Description Each Total Each Total 1 PFC-6006 Conventional 6-Zone FACP 0.105 0.105 0.160 0.160 Panel Standby: 0.105 Panel Alarm: 0.160 P-LINK(RS-485) Standby Alarm RA-6075 LCD Annunciator 0.020 0.025 (Maximum current draw on P-Link&Aux Power combined is limited to.5 Amp) P-LINK Standby: 0.000 P-LINK Alarm: 0.000 2-wire Initiating Devices Standby Alarm PS-24 Potter Photoelectric Smoke Detector 0.000045 0.150000 PS-24H Potter Photoelectric/Heat Detector 0.000045 0.150000 1 `2W-B System Sensor Photoelectric Detector 0.000050 0.000050 0.130000 0.130000 2WT-B System Sensor Photoelectric/Heat Detector 0.000050 0.130000 SLR-24 Hochiki Photoelectric Smoke Detector 0.000045 0.150000 SLR-24H Hochiki Photoelectric/Heat Detector 0.000045 0.150000 User Added Add description and standby/alarm info. User Added Add description and standby/alarm info; User Added Add description and standby/alarm info. Total Alarm 0.130000 Maximum short circuit(Alarm)current is limited to 32mA per initiating zone(6 x 32mA) 0.192000 IDC Standby: 0.000050 IDC Alarm: 0.192000 AUX POWER Standby(amps) Alarm(amps) Ckt Use Description Total Total NAC Notification HORNS AND STROBES 0.00000 AUX 0.00000 0.00000 COMMERCE PLAZA 2/1/2016 Battery Calculation Summary Standby(amps) Alarm(amps) Panel Current: 0.10500 0.16000 P-Link Current: 0.00000 0.00000 IDC Device Current: 0.00005 0.19200 NAC Circuit Current: 0.00000 -- AUX Circuit Current 0.00000 0.00000 Total Standby: 0.105050 Total Alarm: 1.62400 Standby Hours: 24 Alarm Mins: 5 AH Required: 2.53 AH Required: 0.14 Total Combined Standby&Alarm AmpHours Required: 2.67 Efficiency Factor: 80% Required Battery AmpHours: 3.34 Battery AmpHours Provided: 7 Potter Electric Signal(C)2013 1 of 2 PFC-6006 Battery and Voltage Drop Calculation .....ci, POTTER Me Symbol of Protecflon NAC Circuit Configuration& Voltage Drop NAC MAX Circuit Current(amps): 0.5 Source Voltage Used(VDC): 20.4 Usage: Notification Description: HORNS AND STROBES Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 1.272 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Desc Each Total Each Total 3 HORN STROBES SYSTEM SENSOR P2R 0.000000 0.000000 0.137000 0.4110001 7 STROBE ONLY SYSTEM SENSOR SR 0.000000 0.000000 0.123000 0.861000 Total Standby: 0.00000 Total Alarm: AUX MAX Circuit Current P-Link&Aux Power Combined(amps): .5A Source Voltage Used(VDC): 20.4 Usage: Description: Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps Volts @ EOL Min Volts Req'd #14 Solid 2.5 100 0.500 0.000 20.40 16 • Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Desc Each Total Each Total User can add devices on the fly to these bottom 5 rows (No lookup function) Total Standby: 0.00000 Total Alarm: 0.00000 Potter Electric Signal(C)2013 2 of 2 PFC-6006 Battery and Voltage Drop Calculation