Loading...
Report 14 - D60 3 Sw 7,LBulletin 117Rev.R Model F1 Model F1 Recessed Standard Response Reliable SprinkleJCEgf The Designer® Model F1 Sprinkler Standard Upright FEB 2 5 2019 Standard Pendent Extended Coverage Pendent ("l'MA FICA ConventionalQT ILN' � � , Vertical Sidewall Horizontal Sidewall Upright Pendent —HSW 1 Deflector Horizontal Sidewall Extended Coverage —EC-6 Deflector The Designerni Model F1 Recessed Sprinkler Recessed Pendent Recessed Extended Coverage Pendent Recessed Extended Coverage Horizontal Sidewal Vertical Sidewall Co0enfionAI Approval Organizations 1. Underwriters Laboratories Inc. 2. Underwriters' Laboratories of Canada 3. Factory Mutual Research Corp. 4. Loss Prevention Council 5. NYC BS&A No. 587-75-SA 6. Pleniere Assemblee Horizontal Sidewall Recessed Pendent 7. Verband der Schadenversicherer 8. NYC MEA 258-93-E �^'+ UL Listing Category Sprinklers, Automatic & Open (VNIV) MOT Patents: US Patent No. 6,374,920 Applies to Model F1 Vertical Sidewall Sprinklers Extended Coverage Recessed Extended Horizontal Sidewall Coverage Horizontal Product Description Sidewall The F1 Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decora- tive sprinkler. Whether installed on exposed piping or in an office ceiling, it is functional and attractive. The Horizontal and Vertical Sidewall Sprinklers provide an equally attractive appearance when ceiling piping cannot be used. Beautifully versatile is the description for the Reliable Model Extended Coverage Recessed Extended F1 Recessed Designer glass bulb sprinkler. Recessing The Pendent Coverage Pendent Designer®enhances its already low profile decorative appear- ance, and facilitates a rapid and perfect installation. At normal temperatures, the glass bulb contains the fluid Model F1 Recessed Designer's escutcheon is highly ad- in both the liquid phase and in the vapor phase. The vapor justable.The two piece construction makes field installation a phase can be seen as a small bubble.As heat is applied,the very easy and rapid task.This also allows ceiling panels to later liquid expands forcing the bubble smaller and smaller as the be removed without shutting down the fire protection system, liquid pressure increases. Continued heating forces the liq- thus facilitating maintenance of above ceiling services. uid to push out against the bulb,causing the glass to shatter, The Designer® Automatic Sprinkler utilizes a frangible opening the waterway and allowing the deflector to distribute glass bulb. The glass bulb consists of an accurately con- the discharging water. trolled amount of special fluid hermetically sealed inside of a The F1 Sprinkler temperature rating is identified by the precisely manufactured glass capsule. This glass bulb is color of the glass bulb capsule as well as frame color where specially constructed to provide fast thermal response. applicable. The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F1 Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Upright Pendent Conventional Installation Data: Nominal Sprinkler Nominal ThreadSprinkler Approval Identification Orifice Size K Factor Height Organization Numbers SIN US Metric U ri ht Pendent Standard-U ri ht SSU and Pendent SSP Deflectors Marked to Indicate Position '/z" 15mm Yz"NPT RYz 5.6 80 2.2" 56mm 1,2,3,4,5,6,7— R1725 R1715 '%z"(20 nm) 3W,NPT R3/4 ' 8.0 115 2.3" 58mm 1,2,3,4,7,8 R1722 R1712 Yz" 15mm(3) '/z"NPT RYz 5.6 80 2.2" 56mm 7 '%z' 20mm(3) 3/4"NPT R3/4 8.0 115 2.3" 58mm 7 ,r" 11mm /z"NPT R'/z 4.2 60 22" 56mm 1,2,8 R1723 R1713 10mm Yz"NPT RYz z 2.8 E���5�6 mm 1,2,8 R1721 R1711 10mm XLH R% 4.2 4,6,7 R1724R1714 Conventional-Install in U ri ht or Pendent Position 10mmXLH R% 4.2 60 56.1mm R1774 15mm Y2" NPT R1/2 5.6 80 56.1mm- 467 R1775 20mm 3/4" NPT R3/o 8.0 115 58.1mm 4,7 R1772 (')LPC Approval up 286°F(141°C) (2)FM Approval for SSU up to and including 200T(93°C)only. (3)VdS Approval for Intermediate Response 155T(68°C)only. 2. r Model F1 Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench 2 1/4'NOCE EWl [57.2—] 113/16'DN r :!. 1/2'R[pUCCR TURN COLLAR I [JS.,mm X I2.7mm] UN7K rKX,r AIISNCN `ss� L_ J IT ' (J2J 3/4'ADJSrEN00 Vb fI25./1 J F1 Recessed mmJ I'[25A—] I177T;p IA ]27/J2'DM. [72.2-1 When installed directly into a tee,the escutcheon dimension's adjustment will be reduced. Installation Data: Nominal Sprinkler Nominal Thread Sprinkler Approval Orifice Size K Factor Height Organizations Identification us Metric Numbers (SIN) 15mm "NPT R 5.6 80 2.2" 56mm 1,2,3(2)4,5,7 R1715 " " 20mm "NPT(RYA 8.0 115 2.3" 58mm 1,2,3(2,,4,8 R1712 15mm(4) 11 NPT(Ry,)_ 5.6 80 2.2" 56mm 7 " 20mm 4) Y,1'NPT(RYJ 8.0 115 2.3" 58mm 7 ',(11 mm) "NPT RYz 4.2 60 2.2" 56mm 1,28 R1713 3 " 10mm 11 NPT RYz 2.8 40 2.2" 56mm 1,2,8 R1711 _ 10mm R s 4.2 60 56.1 mm 4(3),7 R1714 (2)FM Approval • Light Hazard—No Limitations. • Ordinary Hazard—Groups 1 &2,Wet Systems only. (3)LPC Approval is for 57°C through 93°C ratings. (4)VdS Approval for Intermediate Response 155°F(68°C)only. 3. Model F1 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent 41 Approval Type: Light Hazard Occupancy Vertical Sidewall U.S. Patent No. 6,374,920 Installation Data: Nominal Sprinkler Nominal Thread Sprinkler Approval K Factor Identification Orifice Size Height Organizations Numbers SIN US Metric (SIN) y"(15mm) y"NPT(R}2) 5.6 80 2.2"(56.1mm) 1,2,3,41'),6,8 R1785 LPC Approval is pendent only,57°C through 141°C ratings. Sprinkler Deflector to Type Ceiling Distance Min. - Max. U ri ht 4"t102mm - 12" 305mm Pendent 4" 102mm -12" 305mm Model F1 Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench J,/:6 51'5 (5mm-24mm] '. 1 1/4MIN. T3 .8mm] 2 !;'4" HOLE DIA, 4"-6" rt/,/8, [5 7. i3.2mai7 [101.6mm-152-4mm] CEILING TO s 112" REDUCER / - DFFLf6'10N Horizontal Sidewall - I 7516"DIA. 1 4o 2m m] 1 J - - - 2 27/32 DIA. i%2.2mm] 1y ` L�1J TURN COLLAR UNTIL --- TIGHT AGAINST SPRINKLER y 11RENCH ROSS. I'a:, �'. 3/4" 19.,m] r Ii GGS' AD✓u'S'.M,FNT Installation Data: Nominal Approval Organizations Sprinkler Nominal Thread K Factor Sprinkler Identification Orifice I Size Length Light Ordinary Numbers (SIN) US Metric Hazard Hazard Yz"(15mm) /z"NPT(RY2) 5.6 80 2.63"(67mm) 1,2,3,5 1,2,5 R1735 Note: UL and ULC Listing permits use with F1 escutcheons, light hazard only. 4. rr Model F1 Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model D Sprinkler Wrench Approval Type: Extended Coverage- Light Hazard Occupancy Installation Data: Nominal Temperature Sprinkler Nominal Thread K Factor Sprinkler Approval Ratina Identification Orifice Size US Metric Height Organizations °F °C Numbers(SIN) 17 " 20mm "NPTR3/A 8.0 115 22" 56mm 1,2,8 135; 155 57;68 R1742 Extended Coverage 15mm "NPT R'/z 5.6 80 2.2" 56mm 1,2,8 135; 155 57;68 R1745 Pendent COVERAGE AREA Pressure Flow Rate Nominal Max. Area K=8.0 115 K=5.6 80 Width x Length m L/min psi bar psi bar ft. x ft. m x m 26 98.4 10.6 0,7 21.6 1,5 16 x 16 4.9 x 4.9 33 125.0 17.0 1,2 34.7 2,4 18 x 18 5.5 x 5.5 40 151.4 1 25.0 1,7 51.0 3,5 20 x 20 6.0 x 6.0 Model F1 Recessed Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model RC1 Sprinkler Wrench 2 1/.'HOLE DIA.1 Approval Type: Extended Coverage - Light Hazard Occupancy [572, ' z r5/fe•Ora [<s.2mmJ r IX J/1•REDUCER ____7I [25.41,X f9 I-] OR TURN CGLW 1 I-X 1/2•REDUCER UNTX M"I 1 [25.Imm X 1?.7111 _ WRN!/ ENCH S �R\ ' {rrJTT/'7 L_ IYJ1 L/�J 3/+'ADJUSrur NrIS/16- /19.1111 [2381,] /J.?mmJ 7/4' Extended Coverage Recessed r 17FG02A 2 27/32•D/A, [722--1 When installed directly into a tee,the escutcheon dimension's adjustment will be reduced. Installation Data: Nominal j Temperature Sprinkler Nominal Thread K Factor Sprinkler Approval Rating Orifice Size Height Organizations Identification US Metric °F °C Numbers (SIN) 'y,"(20mm) Y,"NPTR3/a 8.0 115 2.2" 56mm 1,2,8 135; 155 57;68 R1742 1511 "NPT R''/z 5.6 80 22" 56mm 1,2,8 135; 155 57;68 R1745 COVERAGE AREA Pressure Flow Rate Nominal Max. Area K=8.0 115 K=5.6 80 Width x Length m L/min psi bar si bar ft. x ft. m x m 26 98.4 10.6 0,7 21.6 1,5 16x16 4.9x4.9 33 125.0 17.0 1,2 34.7 2,4 18 x 18 5.5 x 5.5 40 151.4 25.0 1,7 51.0 3,5 20 x 20 6.0 x 6.0 5. Model F1 Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC-6 Glass Bulb: 3mm 155°F (68°C) Standard, Unless 5mm 135°F (57°C) is Specified Installation Wrench: Model D Sprinkler Wrench Approval Type: Extended Coverage— Light Hazard Occupancy WOF Extended Coverage Horizontal Sidewall Installation Data: Nominal Thread K Factor Sprinkler Approval Temperature Sprinkler Orifice Size Height Organizations Ratin Identification US Metric °F °C Numbers (SIN) (20mm) %"NPT(R3/4) 8.0 115.3 2.75"(70mm) 1,2,8 135 5mm bulb 57 R1762 155 3mm bulb 68 � COVERAGE AREA Max. Area Deflector to Flow Rate Pressure Width x Length Ceiling Dimensions Min. - Max. m L/min psi bar ft. x ft. m x m 36 136.3 20.3 1,4 16 x 22 4.9 x 6.7 4"(102mm)-6"(152mm) 39 147.6 23.8 1,6 16 x 24 4.9 x 7.3 4"(102mm)-6"(152mm) 6. r Model F1 Recessed Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC-6 Glass Bulb: 3mm 155°F (68°C) Only Installation Wrench: Model GFR1 Sprinkler Wrench Approval Type: Extended Coverage — Light Hazard Occupancy 5186'-�—+i I� 1/8'jJ.zmmJ r [101.6mm TO 157.4mm] 5 TURN TIG , COLLAR � _ spN, TIrh'AGAINST-.hN FR WRFNCH I I 0755 l 15/16-OW (19.Imm] �— +7;/27.014. l�llil li � (11.1mm) I LL- Recessed Extended Coverage Horizontal Sidewall RECOMMENDED WALL HOLE =i 1fi•r;. 1 114'DU (S0.2mm] r57.2-1 (ll 3/4 A0,LISTMFNT "'When installed directly into a tee,the escutcheon dimension's adjustment will be reduced. Installation Data: Temperature Sprinkler Nominal Thread K Factor Sprinkler Approval RatingIdentification Orifice Size US Metric Height Organizations of oC Numbers (SIN) '%Z"(20mm) %" NPT(R3/4) 8.0 115.3 2.75"(70mm) 1,2,8 155 68 R1762 COVERAGE AREA Max. Area Deflector to Ceiling Flow Rate Pressure Width x Length Dimensions Min. -Max. m L/min psi bar ft.x ft. m x m 36 136.3 20.3 1,4 16 x 22 4.9 x 6.7 4"(102mm)-6"(152mm) 39 147.6 23.8 1,6 16 x 24 4.9 x 7.3 4"(102mm)-6"(152mm)) 7. 0 Model F1 & F1 Recessed Sprinklers Maintenance Application The Models F1 and F1 Recessed Sprinklers should Model F1 and F1 Recessed sprinklers are used in fixed be inspected quarterly and the sprinkler system main- fire protection systems: Wet, Dry, Deluge or Preaction. tained in accordance with NFPA 25. Do not clean sprin- Care must exercised that the orifice size, temperature rat- klers with soap and water, ammonia or any other ing, deflector style and sprinkler type are in accordance cleaning fluid. Remove any sprinkler which has been with the latest published standards of the National Fire Pro- painted (other than factory applied)or damaged in any tection Association or the approving Authority Having way. A stock of spare sprinklers should be maintained Jurisdiction. to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be Installation maintained in the original cartons and packaging until Model F1 sprinklers are standard response sprinklers in- used to minimize the potential for damage to sprinklers tended for installation as specified in NFPA 13. They must that would cause improper operation or non-operation. also be installed with the Model D Sprinkler Wrench specifi- cally designed by Reliable for use with these sprinklers. The Model F1 Recessed Sprinklers are to be installed Temperature Ratings with a maximum recess of 3/4 inch (19mm). The Model F1 Sprinkler Maximum Ambient Escutcheon illustrated is the only recessed escutcheon to Classification Temperature Temperature Bulb be used with the Model F1 Pendent and EC Sprinklers.The 'F C of oc Color use of any other recessed escutcheon will void all approv- Ordinary 135 57 100 38 Orange als and negate all warranties.When installing Model F1 Re- Ordinary 155 68 100 38 Red cessed Pendent,EC Pendent,and EC HSW Sprinklers,use Intermediate 175 79 150 66 Yellow the Model GFR1 Sprinkler Wrench. Any other type of Intermediate 200 93 150 66 Green High 286 141 225 107 Blue wrench may damage these Sprinklers. Extra High 11) 360 182 300 149 Mauve Glass bulb sprinklers have orange covers to protect the bulb during the installation process. REMOVE THIS PRO- "Not Available For F1 Recessed TECTION ONLY AFTER THE SYSTEM HAS BEEN HYDRO- Patents: U.S. Patent No. 6,374,920 STATICALLY TESTED AND, WHEN APPLICABLE, THE Applies to Model F1 Vertical Sidewall Sprinklers. ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are Finishes in place. Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Ordering Information White Polyester Coated"' White Painted Specify: Special Application Finishes 1. Sprinkler Model Sprinkler Escutcheon 2. Sprinkler Type Bright Brass Bright Brass 3. Orifice Size Black Plated'°' Black Plated Black Paint""' I Black Paint 4. Deflector Type Off white Off White Satin Chrome Satin Chrome 5. Temperature Rating: Lead Plated."` Specify Bulb Size when ordering Wax Coated"'`°' Wax over Lead Model F1 EC HSW Sprinkler. 6. Sprinkler Finish ("Other colors and finishes are available on special order. p Consult factory for details. 7. Escutcheon Finish (where applicable) 200°F(93°C)maximum. UL and ULC Listed, and NYC Approved Only. 155°F to 200°F(68°C to 93°C)ratings only. 5'286°F(141°C)Sprinklers may be coated for ambient conditions not exceeding 150°F(661C). LPC approved for 10mm and 15mm sprinklers only. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Fac- tory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by The Reliable Automatic Sprinkler Co.,Inc. ellabld Recycled (800) 431-1588 Sales Offices 0 Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. R (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address EG printed in USA. 5/05 P/N 9999970011