Plans (190) ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. EC�j� E CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING DEC 3 U 2015 EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, CITY OF TIGARD FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE REVIEWED FOR CO E COMPLIANCE �,l I Y O f IGARD GALV GALVANIZED HAZARDS PER ART. 690.17. Approved: [ BUILDING DIVISIONGEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY OTC: [ ] HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. Pcrrnit#: � I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL ..� �. ,. Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Address: ;j? Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Shite #• kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC By: Date: LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. OFFICE COPY NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS THREE LINE IAGRM LICENSE GENERAL NOTES PV6 ELECTRCAL CALCULATIONS OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC Cutsheets Attached RGC, CGC1 AND 2012 IBC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON ELECTRICAL SPECIALTY CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Tigard REV BY DATE COMMENTS REV A NAME DATE COMMENTS s UTILITY: Portland General Electric CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB-9723159 00 DISE DEER: DESCRIPTION: DESIGN: ` CONTAINED SHALL NOT BE USED FOR THE NASSER, MICHAEL NASSER RESIDENCE Mark Barton BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SY"TEM: �'.,,. SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY PART To OTHERS OUTSIDE THE RECIPIENTS TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES 3055 CIemkw war THE SALE AND USE OF THE RESPECTIVE (18) REC SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN # REC260PEZ PAGE NAME: SHEET: REV. DATE San 1028 F: 94402 MISSION OF SOLARCITY INC. ���' T:(850)638-1028 F:(650)838-1029 PER ABB PVI-3.6—OUTD—S—US—Z—A (503) 560-1105 COVER SHEET PV 1 12/28/2015 (Bee)-SOL—CITY(765-2489)wrw.salaralty.aam PITCH: 30 ARRAY PITCH:30 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 720 Alice Ave MATERIAL: Comp Shingle STORY: 2 Stories Front Of House (E)DRIVEWAY r, � O � ; M L_D_ AC EfEl sInv LEGEND Q (E) UTILITY METER & WARNING LABEL 8 INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS Locked Gated AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS 0° DISTRIBUTION PANEL & LABELS n LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR MP2 -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED B r,---i INTERIOR EQUIPMENT IS DASHED TOTAL ARRAY AREA (SF): 326 SITE PLAN WScale: 3/32" = 1' TOTAL ROOF AREA (SF): 3124 ZN TOTAL ARRAY AREA IS a 10.44 01, 10' 21' PERCENT OF TOTAL ROOF AREA 3 CONFIDENTIAL S ►x HALL NOT USED FOR THE k B— THE INFORMATION HEREIN Io6nleErt PREMISE DINER: DESORPTION: DESIGN: CONTAINED SJB-9723159 �0 NASSER MICHAEL NASSER RESIDENCE Mark �ulr i., BENEFIT OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: �.�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY ,SolarCity. PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (18) REC # REC260PEZ 3055 gearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NATE SHEET: FIR DATE T:(650)Son Mae C:(650638-1029 PERMISSION of soLARaTY INC. ABB PVI-3.6-OUTD-S-US-Z-A (503) 560-1105 SITE PLAN PV 2 12/28/2015 (888)-SOL-aTY(765-2+89)www.sokrcity.com (E) 2x4 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C S1 ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. 3'-9" 3'-9" (1) 1'- (E) LBW (E) ROOF DECKING (2) C5]) INSTALL LAG BOLT WITH PRE-MANUFACTURED TRUSS 5/16 DIA STAINLESS (5) SEALING WASHER. SIDE VIEW OF MP2 NTs STRUCTURE MEETS THE STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH B PRESCRIPTIVE REQUIREMENTS � WITH SEALING WASHER 6 OF THE OSSC SECTION 3111BOLT & WASHERS. MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 48" 24" STAGGERED (E) RAFTER STANDOFF PORTRAIT 48" 20" ROOF AZI180 PITCH 30 TOP CHORD 2x4 @ 24"OC ARRAY AZI 180 PITCH 30 STORIES:2 Scale: 1 1�2 = 1 BOT CHORD 2x4 @24"OC Comp Shingle CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9723159 00 PREMISE OWNER: DESCRIPTION: DESIGN: ON CTARJED SHALL NOT BE USED FOR THE NASSER MICHAEL NASSER RESIDENCE Mark Barton BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTWG SYSTEM: �.,,SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY ►�� PART TO OTHERS OUTSIDE THE RECIPIECONNECTION T'SWITH MODULEs: TIGARD, OR 97224 3oss CIe ew way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (18) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN RIVIRIER402 PAGE NAME: SHEET: REM! DATE Son T:(850)638-1028,CA 94)638-1029 PERMISSION OF SOLARCITY INC' ABB # PVI-3.6—OUTD—S—US—Z—A (503) 560-1105 STRUCTURAL VIEWS PV 3 12/28/2015 (886)-SCI-CITY(765-2489)www.sol«cNY.com UPLIFT CALCULATIONS 12.28.2015 SolarCity. PV System Structural Version#53.6 Desian Software ProJed Intbrenation&Table of Contents Risk Riisk Category: P _1 II System Type Sola1\.ity SleekMountm Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 301 Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Argo 320 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount Type C Redumd Ground Roof Live/Snow Loads Ground Snow Load pg 25.0 psf ASCE Table 7-1 Surrounding Roof Snow 100% 2S.0pof ASCE Eq:7A-1 Roof Snow Over PV Modules 100% 25.0 psf ASCE Eq:7.4-1 Wind Dalan 6 terla Wind Design Cade ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed v 95 mph Fig.6-1 Exposure Category C' Section 6.5.6,3 Roof Style Gable Roof Rg.6-11B/C/o-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 W nd Pressure Calculation Coetfldents Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor i 1,0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(VA2)(I) Equation 6-15 18.6 Psf Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6-11B/C/a14A/B Ext Pressure Caetficient Down Clown' 0.86 Fig.4.11 W1 Design Wind Pressure p p=gh G Equation 6-22 Wind Preaawre Up P(uP)c -17A pef Wind Pressure Down down 16.2 psf AIS Staff Spaciny Xeon Y-011119ctiort Max Allowable Standoff Spacing Landscape 72" 39" Msec Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-Pv 3 psf Net Wird Uptdt at Standoff T-actual -314 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff P@M@nWC DCR 62.7% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wxtd tlphlt at Standoff T-actual -3S1 lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity Demand/CapacityOCR 70.3% CONFIDENTIAL- THE INFORMATION HEREIN JDB NUMBER: JB-9723159 O O PREMIE OWNER. T� °ESI` CONTAINED SHALL NOT E USED FOR THE NASSER, MICHAEL NASSER RESIDENCE Mark Barton �lrSolarCity. BENEFIT LL ANYONE EXCEPT SOLARCITY INC., MOUNm SYSou 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY A'O NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODIUS. TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (18) REC # REC260PEZ 3055 aearvier Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN VERTIR. PAGE NAME SHEET: REM DATE T:(650)68-10 8 F(650)638-1029 PERMISSION OF SOLARCITY INC. ABBNPVI-3.6-OUTD-S-US-Z-A (503) 560-1105 UPLIFT CALCULATIONS PV 4 12/28/2015 (BBB)-SOL-CITY(765-2489)www.alacity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number:BR204OB200 Inv 1: DC Ungrounded INV 1 —(1)ABB # PVI-3.6—OUTD—S—US—Z—A LABEL: A —(18)REC ## REC260PEZ CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number:23146358 FCI Inverter; Zigbee 360OW, 240V, 96% PV Flodule; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37.8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING Inverter 1 IND CUTLER—HAMMER 200A/2P Disconnect 3 ABB 1 DC+ Vstart = 200V PVI-3.6—OUTD—S—US—Z—A — DC- ————— MP 1� 1x9— (E) LOADS A Ecc zaov ---'—� L2I • DC+ I N 20A/2P ---- GND ————————————————————————------——————— — EGG --- DC+ I 2pC+ VStdrt= 2OOV B I GEC IN DG G_ MP 1: 1x9 I GND EGC--- ----f-- -- GC----- ------------� I I I (1)Conduit Kit; 3/4' EMT N I I EGC/GEC — Z Z C9 GEC To 120/240V SINGLE PHASE UTILITY SERVICE I I I I Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER—HAMMER/BR220 PV BACKFEED BREAKERA (1)CUTLER—HAMMER /DG221URB Breaker, 20A/2P, 2 Spaces Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R —(')CU (1)CUTLERI— MMEER It D 03ONBraleneral Doty(DG) ~ � D� I I _.._._...__._._ _.._.._. ............_...... (2)AWG/10,PV Wire,600V, Black Voc* =375.1 VDC Isc =9.01 ADC O I4F (1)AWG#10, THWN-2, Red O Icz�l—(1)AWG/6,Stranded Bare Copper EGC Vmp =276.3 VDC Imp=8.5 ADC LULL(1)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC I LL LL(1)Conduit Kit;.3/4'.EMT. _ . . .. . . . . . -(1)AWG/B,.TFIWN-2,.Green . . EGC/GEC (1)Conduit.Kit;.3/4'.EMT. . . . . . . . . , (2)AWG/10,PV Wire,60OV, Black Voc* =375.1 VDC Isc =9.01 ADC O (1)AWG/6, Stranded Bare Copper EGC Vmp =276.3 VDC Imp=8.5 ADC I (1)Conduit Kit; 3/4' EMT .. . . . .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN:JB-9723159 00 NASSER, MICHAEL NASSER RESIDENCE Mark Barton SolarCit CONTAINED SHALL NOT BE USED FOR THE I. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARDr OR 97224 THE SALE AND USE OF THE RESPECTIVE (18) REC # REC260PEZ 3055 aearview way San CA 9"02 SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A (503) 560-1105 THREE LINE DIAGRAM PV 5 12/28/2015 (668)-SOL—CITY(765-2489)www.solarcitycom Module: 18 REC 260PEZ 234.3 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 ELECTRICAL CALCULATIONS Inverter 1: 1 ABB PVI-3.6-S AFCI 0.96 3840 4048.7 Vdrop= (imp) * 2*Length) Resistance / Vmp) Module: REC 260PEZ 234.3 Im A Max.Length ftWire Inverter 2: String: 8.5 75 AWG#10 at Max Ave Hi:78 deg F Module: REC 260PEZ 234.3 Vdrop= 8.5 150 0.00124 Ohms / 253.09 0.62 Inverter 3: Branch: 8.5 50 AWG#10 at Max Ave Hi:78 deg F Module: REC 260PEZ 234.3 Vdrop= (8.5 100 0.00124 Ohms) / 276.3 0.42 Total voltage dropin DC conductors= 1.04 Inverter 4: Inverter: 16 15 1 AWG#10 at 240V Vdrop= 16 30 0.00124 Ohms / 240 V 0.13 Total: 18 Modules Total Inv Pwr: 38404048.7 PTC Combinedi at 240V Photovoltaic Module Electrical Specifications: Total STC:I 4680 Vdrop= Ohms) / 240 V Voc: 37.8 V deg F deg C Vmp: 30.7 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.13 Isc: 9.01 A Max Average Hi Temp: 78 126 Total voltage drop in AC and DC conductors= Imp: 8.5 A Record Hi Temp: Tvoc: -0.1 V/deg C Tisc:l 2.16 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 1 way wire length: N/A Voc Correction Factor: ABB PVI-3.6-5 AFCI 1 strings per branch 11 strings per branch 2 Inverter Min Vdc Input: 139 9 REC 260PEZ 9 modules per series string 9 modules per series string Voc= 340.2 Min Vmp at Max Temp: 253.09 Voc= 340.2 V Voc= 340.2 V Max Voc at Min Temp: 375.1 Vmp= 276.3 Inverter Max Vdc Input: 600 Vmp= 276.3 V Vmp= 276.3 V Isc= 9.01 Isc= 9.01 A Isc= 9.01 A Max String Size: 14 Imp= 8.5 Imp= 8.5 A Imp= 8.5 A lcont=l 11.26 Art 690.8(A)(1) 1-way wire length: 50 Icont= 11.26 A (cont= 11.26 A Art 690.8(A)(1) 1.a Conductor: AWG#10 PV Wire 2.a Conductor 1: N/A Conductor 2: N/A Icont*1.25=(Amps) 14.08 Conductor 1 Conductor 2 30 deg C ampacity= 401 F (cont*1.25=(Amps) 14.08 14.08 1.b Icont=(Amps) 11.26 T 30 deg C ampacity= N/A N/A Start ampacity 40 2.b Icont=(Amps) 11.26 11.26 Temperature derate(%=F) 0.82 Start ampacity N/A N/A Conduit fill derate(%=#) 1 Temperature derate(%=F) N/A N/A Derated ampacity 32.8 Conduit fill derate(%=#) N/A N/A 1.c Derated ampacity N/A N/A (cont*1.25=(Amps) 14.08 2.c Term 1 Term 2 Ampacity 40 Temp table N/A N/A Icont*1.25=(Amps) 14.081 14.08 1.d Icont*1.25=(Amps) 14.08 Ampacity N/A N/A OCP Size= 15 Inverter Type A Output 2.d OCP Size 1 151 15 ABB PVI-3.6-S AFCI 1 way wire length: 15 ft Combined Inverter Output (cont= 16 1 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 201 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 15 OCP Size= 201 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont*1.25=(Amps) 20 4.a Icont*1.25=(Amps) 20 Art 690.8(B)(1) 30 deg C ampacity= 40 F OCP size L20 Art 240.6(A) 3.c Icont=(Amps) 16 4.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 (cont*1.25=(Amps) 20 Temperature derate(%=F) 0.91 30 deg C ampacity= 40 Conduit fill derate(%_#) 1 4.c Icont=(Amps) 16 Derated ampacity 36.4 Start ampacity 40 3.d lcont*1.25=(Amps) 1 201 Temperature derate(%=F) 0.91 Ampacity35 Conduit fill derate(%=#) 1 Derated ampacity 36.4 4.d Icont*1.25=(Amps) 20 Ampacity 35 CONFIDENTIAL- THE INFORMATION HEREIN FINVER'ffER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THEJ B-9723159 �� NASSER, MICHAEL NASSER RESIDENCE Mark Barton • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., STEM: .:;,SO�arCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR INount Type C 12798 SW WILLOW POINT LN 4.68 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE C # REC260PEZ 3055 per"Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: T:(650)San Mateo, 28 CA 94402 (650)838-1029 PERMISSION OF SOLARCITY INC. PVI-3.6-OUTD-S-US-Z-A (503) 560-1105 ELECTRICAL CALCULATIONS PV 6 12/28/2015 (888)-SOL-CITY(765-2489)www.�arcitY�, Label Location: Label CAUTION: SOLAR CIRCUIT MAxlti1Uh1 AC - A •Location: WARNING • Per Code: Per Code: Per Code: I FC • MAXIR9UN1 AC NVERTER OUTPUT OPERATING VOLTAGE V 690.54 CONNECTION 690.64.B.7 Label b_ oo DO NOT RELOCATE THIS OVERCURRENT PHOTOVOLTAIC DC DEVICE DISCONNECTPer Code: NEC 690.14.C.2 Label WARNING Code:Per Label ELECTRIC SHOCK HAZARD • • Label DO NOT TOUCH TERMINALSWARNING Location: 690.17(4)TERMINALS ON BOTH LINE ANOPer Code:MAXIMUM POWER- LOAD SIDES MAY BE ENERGIZED ELECTRIC SHOCK HAZARD POINT CURRENT(Imp)-APer o•. IN THE OPEN PdSITION THE DC CONDUCTORS OF THIS 690.35(F) POINT VOLTAGEO Vmp)_V • : E USED WHEN NEC 690.53 PHU O GROUNDED AND ARE MAXIMUM SYSTEM_V MAY BE ENERGIZED INVERTERIS • , VOLTAGE(Voc) SHORT-CIRCUIT ALabel CURRENT(Isc) PV SYSTEM DISCONNECT FOR UTILITY OPERATION Label • • Per WARNING ELECTRICAL SHOCK HAZARD Code: DO NOT TOUCH TERMINALSNEC ••0.17(4) Label L• - • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF • Per LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Code: NEC IN THE OPEN POSITION WARNING: ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH .•1 690.54 ALWAYS PRESENT UVHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label MAXIti1UM AC Location: OPERATING CURRENT A WARNINGPer .._NEC OPERATINGXVOLITIIGE ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED '• NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • CAUTION '• DUAL POWER SOURCEPer Code: SECOND SOURCE IS Label Locati• NEC 690.64.13.4 PHOTOVOLTAIC SYSTEMDisconnect PHOTOVOLTAIC AC '• DISCONNECT Per Code: NEC 690.14.C.2 Label Location: . Distribution . . . CAUTION (POI)Code: Interior - Conduit PHOTOVOLTAIC SYSTEM nnectPer CIRCUIT IS BACKFEDNEC 690.64.B.4 . enter (M): Utility Meter '• Point of • • 1 / /• 1 / 1 / 1 /' 3055 Clearview Way San Mateo,CA 94402 ' 1 •1 1 / I 1 1 1638-1029 • '• 1 7 1 7 '7' Z I 1 / 'F ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 Zep S0 La r 3/26/15 Zep Soca r 3/26/15 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing = module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads design load landscape= 15.35 27.64 27.64 p sf Load Duration Wind Snow ��- Uplift= 656 lbs N/A design load portra4t= 12.28 27.64 27.64 psf Lateral= 357 lbs 290 lbs ' 5�18 note:use 10 psf minimum Down Force= 1074 lbs 771 lbs Snow Calculations � C71sG{}N c, y. To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing Calculations €t .Ru Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 degrees. Uplift Spacing FXPIRESS ?2/3�115 Allowable Uplift Load FOR PAGES 1-4 uplif t spacing-_ Ground Snow Load= 30 psf module length or width x design load Roof Pitch Wind Uplift Calculations 14 30 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98Jpsf p=qh GCN (snow load spread over the length of the rafter) qh=0.00256 K,K:t Kd V I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Combinations: 14 30 Exposure= C Roof Zone= Edge Zone D+S= 31.16 25.10 psf Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof K,,= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.755 31.59 31.91 psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force Jscape effective area= 13.0 ftz GCN portrait=-1.5 7711bs in ortrait effective area= 21.7 ft' landscape down force spacing = 39"x 31.91psf x 144T-tz =89" Plandscape= -49.13 psf qh= 30.71 psf Pportralt= -46.06 psf 771lbs in portrait down force spacing = 65"x 31.91psf x 144 ftz = 53" Uplift Load Combination:0.61)+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf 656 lbs in landscape uplift spacing = x 144 39"x 27.73 psf f= 87" tz 656 lbs in Portrait uplift spacing = x 144 65"x 25.89 psf f= 56" tz ZS Comp Edge Zone Calculations 3 of 4ZS Comp Edge Zone Calculations 4 of 4 . � 3/26/15 ' 3/26/15 Ze Solar ZepS��a C Lateral Spacing Module Deflection Spacine The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Upli f t or Down Force Pressure+79.909 Allowable Lateral Load Maximum U p p Uplift Pressure Landscape= -27.73 lateral spacing = module width x designload Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf ps=Cs pf Roof Pitch= 31 45 degrees landscape module spacing= -1.4545 x 31.91 psf+ 120.7273 =74" pf=0.7CeCfIpg Ce= 0.9 C,= 0.71 0.45 Cf= 1.2 pf= 22.68 22.7 psf portrait module spacing= -0.8182 x 31.91 psf+79.909 = 54" I= 1.0 ps= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 1 25.98 1 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30" 27° 30" Lateral Force Component 1 74" 48"' 44" Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". landscapespacing_ 290lbs in p 39"x 14.49 psf x 144 ft2 = 74" portrait lateralspacing _ 290lbs in p 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 290lbs in portrait lateral spacing = x 144 65"x 13.50 psf f48" tz = i .w, 'i`,',SOlarCity ZepSolar Next-Level PV Mounting Technology t�SoiarGty Z pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs =fi ` p-roof Leveling Foot 8rorwrd Zep .tntcrfock Illllltllllr ., �kv Poet Part No.850-1172 f _ ETL listed to UL 467 Zep Compakfltks PV Module ij `t i Root AMK+dnent SS �. Comp Mount Part No.850-1382 Listed to UL 2582 - Mounting Block Listed to UL 2703 �coMPAT'� 9 P 9 Description " PV mounting solution for composition shingle roofs " • Works with all Zep Compatible Modules OOMPP� • Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" �L LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 ink A& • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com Listed o L 156567 Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Solar inverters Additional highlights: - RS-485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and AN Interruption(-A Version). f t m t Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US AN Mechanical specifications Nominal output power 3000W 360OW 3W0 - 380OW 420OW Maximu1.m output 11 power watt11 ag11 e 3000 3300' 3300' 3600 4000' -4000 1 1 3300 4200' 4200' 4200 4600' 4600' .....:.......W W W W W W W W W W W... W Rated grid AC voltage - 208V 240V 277V = 208V ! 240V - 277V - 208V 240V = 277V 208V 240V 277V Input side(DC) Number of independent MPPT channels 2 2 2 ._ 2 Maximum usable.power for each channel 2000W 3000W 3000W... 3000W ....., Absolute maximum voltage(Vmax) 600V . Start-up voltage(Vstart) 200V(adj.120-350v) t Full power MPPT voltage range 160 530V 120 530V 140-530V 14o 5mv Operating MPPT voltage range 0.7 x Vstart 580V(> 90V) w 46 Maximum current(Idcmax)for both MPPT In 20A 32A 32A 32A r, parallel _...... Maximum usable current per channel 1 oA ! 16A 16A 16A Maximum short circuit current limit per 12.5A 20.0A 20.0A 20 OA channel ., Number of wire landing terminals per channel 2 pairs „ 3 O'sm" Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output side LAP) ty Grid connection type t0/ Split- 10/ = 10/ Split- 10/ 10/ Split- = 10/ = 10/ Split 10/ 2W 0/3W 2W 2W 0/3W 2W 2W . 0/3W 2W 2W 0/3W 2W Adjustable voltage range(Vmin-Vmax)(V) 183 211- 244 183 211 -244 183- 211 - 244 -- 183 211- 244- Adjustable 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V .. ............. ........ _. ... Grid,frequency 60Hz Adjustable grid frequency range 57 60 5Hz Maximum current 14.5 14.5 12.0 ' 17.2 -16.0 16.0 16.0- 16.0 16.0 20 0 20.0 20.0 .cu ..:....A„M� Aa— A.Mx AHras '_..A„s ._ANMF ANMs. A`Nms Auvs -....p`Hxu....:....A„. .....Aa—... Power factor --- -- >0.995 Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG1O-AWG4 inverters complements the typical time power tracking and improved – Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Vanstor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high - Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of theproperty. a consistent and stable performance - The high speed and precise MPPT Anti-voltage protection Meets UL 174 r,2(L, 547 requirements P 9 p P Over-voltage protection type Vanstor,2(L, L,1/ across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A 20A 15A i 25A z 20A 20A i 20A 20A_:20A 25A 25A 25A This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96 9% 97% .. 97%___. 97% P g P 9 9 CEC efficiency 96 with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W_ This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8WCommunication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display ..... .1.... orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring ItXRS485 incl.) VSN700 Data Logger(opt.) Envircioriented in different directions.(For designed to be a completely sealed Standards(-S Version). Ambient air of Ambient air operating temperature range 13°F to+140°F with derating above 122°F(50°C) _ example:East and West) unit able to withstand the harshest Ambient air storage temperature range -40°F to+ns F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity o 1 oo°o RH condensing Acoustic noise emission level <50 db(A)®1 m independent MPPT enable a more Maximum operating altitutde without derating 6560 ft(2000 m) AL ,� ,� 11 11 optimal energy harvesting condition. Power and productivity Capability enabled at nominal AC voltage and withe I uffi 11 cent DC power available for abetter world" P%1919 2 A88 Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD N, a YEMWA W _ g f «.. _ t M iXY i, f E € All measurements in Inches ` DA S, REC260PEZIill 4111., ' x isNominal Power PM„€,(WP) 2602 WattClassSortiing-(Wp) t/-5 � Nominal Power Voltage-VM,n(V) 30.7 ?' Nominal Power Current-I (A) 8.50 fir tr p hrE , c x, Open GrcudVoltage-Vpc(V) 37.8 � �7 I <: ;, ShortGrcudCurrent-I,(A) 9.01 . k PanelEfficiency(/o) 15.8 ,,; "�;_ �, f,xi> <�'%H' <"t y,. The electrical ch- acteYstics are within./-10%ofthelndicated values of I,,,V„and P. ”" `+:'" <€ �?.',§ Values at standard test conditions STC at standard 25'C))conditions(STCI. . (airmass AM 1.5 7€adance 1000 W/m'cell temperaw e 77"F(25"CU. °i�.'rr _; Af Inw irradiance of 200 W/m'(AM IS&cell temperature 77'F(25'C))at least 97%af the STC panel,fftlency will be achieved. 7 REC260PEZ Nominal Power-P_(Wp) 197 % Nominal Power Voltage-VM€,€,(V) 29.0 Nominal Power Current-Im,,,,(A) 6.81 Open CircuitVoltage-Voc(V) 357 y r I ShortCircultCurrent-Isc(A) 7.24 Nominal operating cell temper atur a NOCT(800W/m',AM15,w,dspeedlm/s an Ment teperatme68*F(20°C). p 1 a y 10 year product warranty. z � c@ua 25 year hnearpoweroutputwarranty t LIM (max.degression in performance of 0.7%p.a.). UL 1703,Fire rating_Type 1,Class C A 34 (€ D E REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing RCC products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better meet the world'sgrowing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com I ";^So1arGty ZepSolar Next-Level PV Mounting Technology . DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE DWV DEBRIS GUARD COMP ROOF MOUNT COMP ROOF O DWV Debris Guard Construction Detail Debris Guard,close up �G0141`4T/e` Prevent blockages and keep vents open with the DWV Debris Guard. • / Protects against: FA a Leaves Rain OOMPPS� • Pine needles Insects • Snow Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. zepsolar.com This document does not create any express warranty by Zap Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. • Document#800-1677-001 Rev A Date last exported:April 3,2015 4:04 PM