Plans (2) FOR OFFICE USE ONLY—SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
MCity of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
E Transmittal Letter
13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.ti arg d-or• og_v
TO: �/ DATE RECEIVED:
DEPT: BUILDING DIVISION RECEIVIED
FROM: -
CITY OF TiGAP0
I.�+ 'V;Q
COMPANY• J �: � �.r . .4,,.C1`�
PHONE: �� —"� ��-=�9C) / By
RE: L� v7�-- 6 2- S _' dv
rte Address (Permit Number)
ro�e�.--leo
ct name or su rvi ion name and lot number)[
ATTACHED ARE THE FOLLOWING ITEMS:
Co ies: Descri ` on: . " Copies: Description.
Additional set(s) of plans. Revisions:
_ Cross section(s) and details. Wall bracing and/or lateral analysis.
Floor/roof framing. Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
REMARKS:
r
i
/ rt
.': ,. :FOR OFFICE`USE ONLY.
,; - .
Routed to Permit Tec cian: Date: Initials:
Fees Due: ❑ Yes No Fee Description: Amount Due:
ten,
+ $
$
Special
Instructions:
Re rint Permit (per PE): ❑ Yes I WdNo ❑ Done
Applicant Notified: Date: Initials:
,C�PA,L- w / 11
1:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012
RECEIVED
JAN 4 2015
CITY OF TIGARD
f1 BUILDING DIVISION
PROVIDE NEW IN-LINE FAN. CP� DUCT5 DOWN TO TOP OF NAIL
GREENHECK(G40 CFM) STATION. (See Nall 5tatlon "54"for Detail) 5E-
FOR 50 CFM
100 ROOF CAP. LOCATE MINIMUM
OF I O' AWAY FROM HVAC UNIT
INTAKE
95CFM %P1
85 CFM 395
I 95 M 90 AFM
O
e
1
0 0 0
i 7 M 785
byi/D CFM
W.H.
e
100 LL100 0
1
s0 100 100 e0 I
E ROOF MOUNTED \
+a" HVAC UNIT
J v
0 0 o a M
+ CFM — '110
f --
CFM i 395
CFM
WATFR TEM
NOTE: MECHANICAL PLAN 4
1. Occupancy Type or room qualifies as Naturally Ventilated(No mechanical ventilation required) Scale:3/e'= 1'-0" ® NEW 12"x 12"AND 24"x 24"CEILING
2. People Outdoor Airflow Rate in Breathing Zone(cfm/person)from OSMC Table 403.3 SUPPLY GRILLE
3.Area Outdoor Airflow Rate in Breathing Zone(cfm/SF)from OSMC Table 403.3
4. Default Occupant Load, Persons per 1000 Sq. Ft.from OSMC Table 403.3 Expected average occupancy but z NEW 24"x 24"CEILING RETURN GRILLE
not less than Y2 Table value
5. Space Uncorrected Outdoor Air Intake per OSMC Equation 4-6(with deversity applied)
6.Zone Air Distribution Effectiveness(Ez)from OSMC Table 403.3.1.2
7. Primary Outdoor Air Fraction used to select System Ventilation Efficiency(Ev)from OSMC Table 403.3.2.2.2
8. Locate Exhaust Fan Roof Cap minimum of 10'away from HVAC unit outside air intake �a G MA) V1. /A&
REVISION �
l
i
OFFICE COPY
7
EXISTING ROOF DECK AND EXISTING ROOF DECK AND
JOIST SYSTEM JOIST SYSTEM V-8" QUARTZ COUNTERTOP
OVER 3/4" PLYWOOD
3 DUCT TO EXTERIKOR -
'/4' WOOD 2 x G PLATE
Sti ELF
4" 0 EXHAUST DUCT
EMPLOYEE 2 x 4 CUSTOMER
SIDE 7" BLOCKING SIDE
Y2' GYP. BD. BOTH SIDE
CV
2 x G STUD @ 24"
SOFFIT CEILING O.C.
ELECTRICAL OUTLET
I X G WOOD
BASE
P.T. 2 x G SOLE
4" PVC INSIDE EXISTING WALL PLATE
1'-8° TYPICAL - D DETAIL
Scale: 1"= 1'=0"
p o0 00 0o p
i
N CV
QUARTZ COUNTERTOP M
OVER 3/4" PLYWOOD
MANICURE STATION (EMPLOYEE SIDE) 2 x 6 PLATE
Cz��r cc
.T v2" GYP. BD. BOTH SIDE
iV
2 x G STUD @ 24"
O.C.
ELECTRICAL OUTLET
,i I X G WOOD
CD
0
P.T. 2 x G SOLE
N�I
PLATE
• SECTION 3 - 3 �
MANICURE STATION (CUSTOMER SIDE)