Plans SITE PLAN-SCALE=1116"= '-0" PITCH TRUE MAG PV AREA 1 AZIM AZIM (SQFT) ® AR-01 31' 190° 174° 53.2 AR-02 31° 190° 174° 53.2 AR-03 31° 190° 174° 124.2 PL PL PL -o v � r - - FIRE SETBACKS (12 TYP) j (N)ARRAY AR-03 r (E) RESIDENCE _1 (N)ARRAY AR-02 (E) FENCE - (N)ARRAY AR-01 sunrun INV MPS OR CL#180464 p O d SE p 3360 S E 20TH,PORTLAND,OR 97202 SM d d Q� PHONE 888.657.6527 p FAX 503.205.0748 d p a p CUSTOMER RESIDENCE: d 4 d JIM EMERY p 8345 SW DEEANN CT PL p PORTLAND OR USA 97224 C d d p < p d v TEL.(971)255-4664 APN#:2S102DD03100 D a a p PROJECT NUMBER: ° d p 601 R-345EMER p 4 Z 4 DESIGNER: a d _ p d p a p a MICHAEL LANDA eoss4o.e3io p ° d p ° PL DRAFTER: a P� DI d Q d P� 0 SHEET _ SITE PLAN REV:A 12/18/2015 PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA 1 EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-01 COMP SHINGLE FLASHED L FOOT, SEE PEN D01. TWO STORY ATTIC WOOD CARPENTER TRUSS 2 X 8 12'-0" 24" NO 4'-0" 1'-4" REC SOLAR: REC275TP AR-02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD CARPENTER TRUSS 2 X 8 12'-0" 24" NO 4--0" 1'-4" MODULE DIMS: ctr A,,-'20"- I r"' AR-03 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD CARPENTER TRUSS 2 X 8 12'-0" 24" NO 4'-0" 1'-4" MAX DISTRIBUTED LOAD: 3 PSF D1 -AR-01 -SCALE:3/16"= 1'-0" SNOW LOAD:25 PSF D2-AR-02-SCALE: 3/16"=V-0" WIND SPEED: PITCH: 31° PITCH: 31° 95 MPH 3-SEC GUST. AZIM:190° AZIM:190° LAG SCREWS: ® ® 7'-6" – 5/16"x3.5":2.5"MIN EMBEDMENT 88 % L� 95 % 7'-7" i -4'TYP _ 0 3 ! 0 � - -� 87% $�% 83% 4'TYP--- 4 $- gv/ $- 5'-6" 3 93 % 91 % T' 7"�j sunrun D3-AR-03-SCALE: 1/8"= 1'-0" PITCH:31° AZIM:190° OR CL#180464 6'-9"— 16'-5" – 8'-1" 3380 S E KITH,PORTLAND,OR 97202 PHONE 888.657.6527 FAX 503.205.0718 CUSTOMER RESIDENCE: f JIM EMERY ~O o — 8345 SW DEEANN CT _ Q -- a PORTLAND OR USA 97224 -�- 91% 89% TEL.(971)255-4664 APN S:2S102DD03100 - � PROJECT NUMBER: 601 R-345EMER 23'-11" DESIGNER: 6 _� MICHAEL LANDA 5'-6" //8\ -6'-7"- 87% 0' 805.5/0.8310 76% DRAFTER: DI SHEET 5'-l" ® Q LAYOUT REV:A 12/18/2015 [PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER M PGE 24522 1625 UTILITY GRID CVIC"T141/� C 200A MAIN BREAKER (END FED) EXISTING 200A MAIN SOLAREDGE TECHNOLOGIES: FACILITY PANEL (N)SUN RUN SE3000(240V)W/-ER-US OR A-US LOADS METER 3000 WATT INVERTER PV MODULES REC SOLAR: REC275TP --o o-- 3 3 + ffj OPT MOIZERS WIRED IN(1)SERIES OF 13 OPTIMIZERS FACILITY JUNCTION BOX 20A PV °RO1"'D 250V METER SOCKET LOAD RATED DC MIN RATED NEMA3R SOLAREDGE POWER OPTIMIZER BREAKER AT 125A CONTINUOUS& DISCONNECT&AFCI OPPOSITE END OF 240V METER P300 BUSBAR FROM 200A, FORM 2S MAIN BREAKER NOTES TO INSTALLER: CONDUIT SCHEDULE 1. 13 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. # CONDUIT CONDUCTOR NEUTRAL GROUND 2. ADD 20 AMP PV BREAKER TO MAIN PANEL. sunrun 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER E3 2 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1)6 AWG THHN/THWN-2 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 OR CL#180464 3380 S E 20TH,PORTLAND,OR 97202 PHONE 888.657.6527 1 FAX 503.205.0748 MODULE CHARACTERISTICS OPTIMIZER CHARACTERISTICS CUSTOMER RESIDENCE: JIM EMERY REC SOLAR: REC275TP 275 W MIN INPUT VOLTAGE 8 VDC 8345 SW DEEANN CT OPEN CIRCUIT VOLTAGE 38.8 V MAX INPUT VOLTAGE 48 VDC PORTLAND OR USA 97224 MAX POWER VOLTAGE 31.4 V MAX INPUT ISC 10 ADC TEL.(971)2554664 aPN#:2S102DD031oo SHORT CIRCUIT CURRENT 9.4 PROJECT NUMBER:A MAX OUTPUT CURRENT 15 ADC 601 R-345EMER SYSTEM CHARACTERISTICS-INVERTER 1 DESIGNER: SYSTEM SIZE 3575 W MICHAEL LANDA 805.540.8310 SYSTEM OPEN CIRCUIT VOLTAGE 13 V DRAFTER:DI SYSTEM OPERATING VOLTAGE 350 V MAX ALLOWABLE DC VOLTAGE 500 V SHEET ELECTRICAL SYSTEM OPERATING CURRENT 10.2 A SYSTEM SHORT CIRCUIT CURRENT 15A REV:A 12/18/2015 PER CODE:690.52 PAGE PV-4.0 IIARNING PHOTOVOLTAIC IPOWERPVSYSTEM UTILITY RATED AC OPERATING CURRENT 15.63 AMPS SOURCE BREAKERS LOCKABLE AC DISCONNECT ELECTRIC SHOCK HAZARD AC NOMINALOPERATING V• ` • ARE BACKFEEDING LABEL LOCATION: IF A GROUND FAULT IS INDICATED , VOLTS AC DISCONNECT NORMALLY GROUNDED CONDUCTORS [Only for systems>7kW] MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: 15.63 ` ' AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: (PER CODE:NEC690.54) LABEL LOCATION: DC DISCONNECT,INVERTERWARNING AC BREAKER AND AC DISCONNECT (PER CODE:NEC 690.35(F)) [Inside or front of panel] [ro be used when inverter is ungrounded] INVERTER • • • • . • • WARNING . . II CUSTOMER . ` ' LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION GENERATOR • ' UT (PER CODE:NEC 705.12(D)(7)) LABEL LOCATION: THE DC CONDUCTORS OF THIS [Not required if panelboard is rated not less than sum of ampere ratings SUNRUN METER PHOTOVOLTAIC SYSTEM ARE UNGROUNDED of all overcurrent devices supplying it] AND MAY BE ENERGIZED LABEL LOCATION: CAUTION: SOLAR CIRCUIT DC DISCONNECT,INVERTER (PER CODE:NEC 690.35(F)) LABEL LOCATION: [To be used when inverter is ungrounded] MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND ABOVE/BELOW WARNINGPENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE:IFC605.11.1.4) ELECTRIC SHOCK HAZARD SOLAR DISCONNECT DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LABEL LOCATION: LOAD SIDES MAY BE ENERGIZED DISCONNECT,POINT OF INTERCONNECTION IN THE OPEN POSITION (PER CODE:NEC690.13(B)) DC VOLTAGE IS ALWAYS PRESENT INVERTER 1 WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT POWER LABEL LOCATION: POINT 10.2 sunrun AC DISCONNECT,POINT OF INTERCONNECTION (PER CODE:NEC 690.17(E)) POINT RATED MAXIMUM VOLTAGE POWER- • 350 A WARNINGMAXIMUM SYSTEM 500 ELECTRIC SHOCK HAZARD 15MAXIMUM CIRCUIT OR CL#180464 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND 3380 S E 20TH,PORTLAND,OR 97202 LOAD SIDES MAY BE ENERGIZEDLABEL LOCATION: PHONE 888.657.6 FAX 503.205.0748 IN THE OPEN POSITION DC DISCONNECT,INVERTER LABEL LOCATION: (PER CODE:NEC690.53) AC DISCONNECT,POINT OF INTERCONNECTION CUSTOMER RESIDENCE: PER CODE:NEC 690.17(E),CB JIM EMERY aW�ARNAFIG t11lN.4+QYil!l�tSOURCE 9Et�Ot�SOtll�CEISPi�'f101Mr01•TAICSYStF•II 8345 SW DEEANN CT WARNING-Electric Shock Hazard PORTLAND OR USA 97224 No user serviceable parts inside LABEL LOCATION: POINT OF INTERCONNECTION TEL.(971)255-4664 APN#:2S102DD03100 Contact authorized service provider for assistance I! LABEL LOCATION: (PER CODE:NEC 705.12(D)(4)) PROJECT NUMBER: INVERTER,JUNCTION BOXES(ROOF),AC DISCONNECT CAUTION'SOLAR ELECTRIC 601 R-345EMER (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) WARNING: PHOTOVOLTAIC SYSTEM CONNECTED DESIGNER: POWER LABEL LOCATION: MICHAEL LANDA DnIKIT nC 1k1TCOrnk1k1=rTInK1 805.540.8310 LABEL LOCATION: (PER CODE:NEC690.15,690.13(B)) CONDUIT,COMBINER BOX DRAFTER: (PER CODE:CEC690.31(G)(3)(4)&CEC 690.13(G)(4) DI • ADHESIVE FASTENED SIGNS: SHEET •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT SIGNAGE WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD REV:A 12/18/2015 COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER PAGE PV-5.0 RESISTANT[IFC 605.11.1.3]