SGN2016-00009 CITY OF TIGARD SIGN PERMIT
Permit#: SGN2016-00009
COMMUNITY DEVELOPMENT Date Issued: 01/26/2016
m 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 1 S134AA01900
Jurisdiction: Tigard
Name of Business: Express Employment Professionals
Business Address: 10115 NIMBUS AVE 500
Applicant/Agent: Kracke,Cyndi
Work Description: One(1)41.15 square-foot wall sign on north-facing wall. Single element that weighs 115
pounds.
Permanent: Yes Freestanding: No Freeway: No
Temporary: Wall: Yes Electronic: No
Billboard: No Balloon: No
Banner: No A-Board: No
Sign Dimensions: 3,x 12.5'
Total Sign Area: 41.15
Wall Area: 825
Wall Face(Direction): North
Sign Height: 28 ft.
Projection From Wall: 10 in.
Illumination: Internal
Materials: Acrylic, aluminum, and LE
Electrical Permit Required: Yes
Building Permit Required: Yes
Total Permit Fee: $197.00
Conditions:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and
all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within
90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon
sign shall expire 10 days from validity date.
Approved By: C>
Permittee Signature:
RECEIVED
City of Tigard JAN 2 g 2016
COMMUNITY DEVF,LOPMENT DEPARTMENT
CITY OF TIGARD
Sign Permit Application PLANNING/ENGINEERING
SIGN LOCATION
Address: I of (S Slv 1yi1nt--&/,S Suite#: -z5da REQUIRED SUBMITTAL
ELEMENTS
City/state: 1-16,R7,90 z7d� Zip: 2Z3 _ 1/2 copies of elevations on 81/z"x 11
Tenant or business: In 67A or 11"x 17"pages(Wall sign
M�
e5lwN� ftiA154>V
elevations must include dimensions
l�y J of sign and wall face and show the
Property owner name: - location of sign on the wall.
Address: ,` 47W Freestanding sign elevations must
City/state: 0 tlCW1/C:� Zip: drawn to scale.)
Phone: Email:
copies of site/plot plan,drawn
to scale,on 8'/2"x 11"or 11"x 17"
Sign contractor: Serle -rrt/ SIG A! s,
_ m(c-- ages(not required for wall signs)
�— ai
/ust or diagram of all existing sign
Address: ��f 2 i 5E HOL4�E 01— ensand square footage
City/state: /�0/2Tlf�9llD, zip: 20.2. E Application Fee
Phone:��5 !9ffe 7m:Z-mail: ,Deem i--S a S c c-f iftr 5 i gn S CDM
CCB License #: !Z 2809 //�Expiirrattiion date: Dy30 /to NOTES:
Contact person: /V D I /ti1f�4KE Freestanding signs over G ft.in height
_ - - - ----- - and walls signs of which any element
____ ___ weighs 20 lbs.or more require a
SIGN DATA(Complete all items ibuilding permit for construction.n this section) If any element of a wall sign weighs
70 lbs.or more,plans must be prepared
—TYPE (Check all that apply) by a structural engineer.
ngineer.❑ Freestanding V�,Kectrical El • Buildipg permits require 2 sets of
❑ Alteration to ❑ Freeway C9-Wall construction drawings and,if sign is
freestanding,2 copies of site/plot plan
existing sign ❑ Roof ❑ Other and 2 sets of engineering must be
Sign#: submitted with building permit
application.
of
Sign dimensions: 'K(h) x I(ZV(w) = 10- -!rq.ft. sign area
New sign: �sq.ft. + Existing sign area sq.ft. = Total ' STAFF USE ONLY
Total area: /l� h./ M�uil ' faces .ft._ %of bldg face ^ ,
sign 9 9 g Case No.: —7/V 22 �p" O
Height to top of sign: (NIU nft. Projection from wall: D in.
Materials: YL-l G, li�i m l n(il//l� Led L l�l Ks Feeated Case N .(s):
Application accepted:
Is the sign under 20 lbs.? ❑ Yes NoLS I Q� f
(o
(Building Permit required if over 201b
Direction wall faces (circle one) N S E W NE NW SE SW $y: Date:
Application determined complete:
Will the sign have illumination? Yes ❑ No
By: Ls Date: L,2
If yes,what type: UK Internal ❑ External 1:\CURPLN\Masters\Land Use Applications Rev.03/03/2015
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 2
F
APPLICANTS
NOTE: Pcxsnn specified as"Applicant"shall be designated "Permittee"and shall provide financial assurance for work.
Winn tilt uwner and the applicant arc differcm ncople,the applicanr mu=t be the purchaser of record or a lessee in possession with written
authorization from the owner or an agent'-of the owner. The owner(s)must silp,this application in the space provided on the back of this
forrn or summit a written authorizition with This applica6un.
THE APPLICANT(S) SILK. CERTIFY THAT:
1 f the application is granted,the applicant Will exercise the rights granted in accordance with the terms and subject to all the
conditions and hnutaLlonS of the approval.
All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that anti•permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application, including the policies and criteria,and understands die
requirements for approving or denying the application.
I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner
or authorized,agent of the owner,and that plans submitted are in compliance with the City of Tigard.
SIGNATURES of each owner of the subject property required.
AP lic, it's signature j Print name Date
r ,yam. ".. '�' •'-•�._� ---- �._1,�=�_.�;� '_I-�1_,�__ ! � ' f�,
Owner's`signatuc iJ Print name Date f '
{},,t.ncr's signature `- - _---- Print`name ---�- — Date
SIGN PEPWIT APPLICATION
Cit\ of Tigard • I'127 SW 1 lall lRh•d. • 'Cign d,0rcgon 97223 1 503--/]S-2421 Page 2 of 2
SECURITY
SIGNS
IyR 'A '; * • Q..ay Since 1925
:"; lgate
#5 Cartridge World / 32sf ou24245EHoregon 97202
rd
k 503-232A172 fax503-230-1861
WWW.securitysigns.com
OR CCB.122807 WASECURSIUfC
#4 - Jet Set Coffee / 24.61 sf #6 - too cute / 30sfIN GTME
NORTHIMESISIGN COUNCIL
#3 - Image Nails Salon / 30sf '' � #7 - gentle dental / 35sf •••
N, w' I Dylan Martin
r, * ,, c
DESIGNER
#2 - Bellagios Pizza / 30sf mm ,,• t�\ ,� .• , #8 - Nimbus Cleaners / 30sf
#1 - Miller Paint / 35sf r► #9 - Shiraz Grill / 25sf
N •
._� #10 - Filling Station / 34.64sf o •
4 •
, • +. � W
0
IV,
* R „ ♦ A •. DESCRIPTION
. Site Plan
-
N Q7¢
LREVISIONS
Eliminate Option 1
' .
2 f 2016
rOF TIGARD
{t,' `•,may'
1 c i
lllk
HIM T
h..y d
APPROVALS
v.G `
Client Signature
Landlord Signature
z _
4
.„_s.
w
3 `
c
Google earth
'' •
1995 " ' Imagery Date: 7x 14/2014 45026'47.89" N 122°47'24.16" W eleu 167 ft eye alt 1303 ft `;
33'-0"
Channel Letters
Illuminated SECURITY
Manufacture and install one (1) wall display SIGNS
I ty Sime 1925
'Express' 2424 SE ool gle Boulevard
Faces: .150 White Acrylic Portland,Oregon
Returns: .040 Aluminum, 5" deep, Heron Blue '
'
Backs: .040 Aluminum, pre-coat white
Bridge: Fabricated aluminum, paint to match fascia
Illumination: White LEDs �.
f > 'SM' Tab: .090' Aluminum painted white with applied NORTHWESTSI6NCOUNCII
-ress
Avery A9584 T Night Sky Blue vinyl
Alig-, Align
PROJECT MANAGER
'Employment Professionals' Wrap Dylan Martin
Faces: .150 White Polycarb with applied Avery DESIGNER
A9584-T Night Sky Blue J.Wallace
28'-3 1/2" 25'-0" Trim Cap: 1" Blue Jewelite
Returns: .040 Aluminum, 5" Deep, Heron Blue PROJECT NAME
Backs: .040 Aluminum, pre-coat white
Illumination: White LEDs .
� M
q Raceway o
Construction: fabricated aluminum, 5" x 22", �' z o
painted Miller 0555 Ocean Frigate �: v0
I Ln
InstallationO
PRIMARY ELEVATION Wall Type: Concrete - verify.
VATION e C
Scale: 1/16" = VA Mounting: Flush mount with 3/8" shielded lags.
Power Supplies: Raceway mounted. LU
CITY Or TIGARD Primary: One dedicated 120v/20amp circuit required
Approved by Planning
per display PAGE DESCRIPTION
Wall Sign
Colors
Date: a l
Initials:
S ■ Avery A9584-T Night Sky Blue REVISIONS
11'-10" � I Q
White Acrylic/White Polycarb Eliminate Option l
■ Blue Jewelite / Heron Blue Returns RECEIVED
5" 5"
■ PTM Miller 0555 Ocean Frigate JAN 2 s 6
CITY OF TI RD
51, 5" PLANNING/ENG
27 . CHANNEL LETTER RETURN o�vrasnezg t,R. Mrsy x ice.
All Ruts R.--.d
bo
39 1/2" dsaa's;a re�de;the1��g eb
N r 9e
1" JEWELITE TRIM — plus at"„ems andn o ,for e
LED CABLE �n(iu.sC.alzaso4)the us.cent
ACRYLIC FACES
8-1/2" I • • , • 1h" POWERS TOGGLE BOLI :gid< ,e"„x, ,« M f,k 'kaon
/ HEYCO REDUCER SNAP
BUSHING '�Nei—,1 i ,1 Epi c�k� i,«
.�pK.em wear mem.rna�Mwd.,min
PRIMARY SINGLE POLE -
NON-HARDENING tne,re
SWITCH SERVICE DISCONNECT WEATHERPROOF SEALAN
End View APPROVALS
LED MOD-60 -
POWER SUPPLY Client Signature
LED MODULES METAL OF FLEXIBLE CONDUIT
Landlord Signature
DRAIN HOLE
- �- PRIMARY BRANCH CIRCUIT DATE: 1.14.16
• 25 X 33' 825 S.F. JUNCTIONBOX/SERVICE
DISCONNECT
• 825 x 5% = 41 .25 S.F. Channel Letter Section Scale: NTS PAGE #:-3.OF 2
WALL DISPLAY DETAILS - 39 Sq. Ft. _
Scale: 1/2" = V-0" DRAWING#:
15-JW914r1 P
WALL SIGN ANCHORAGE CAPACITY TABLES:Scope of work is for the anchorage of the raceway to the supporting structure only.
LOADING CRITERIA:(ASCE 7-10
3-secong gust Speed 120 mph(max)
Exposure B (max) x1
Risk Category II (max)
GCp= -1 40
qh= 13 2 psf
F= -16.5 psf 0
Sign Dead Load= 4.00 psf(max) - n'
d= 22 in(min)
Hon z offset.x1= 7.5 in(max)
___. .._.
Vertical offset.x2=E422
4 in max
The area used in the'area per anchor'column of the table is the actual solid area of the Sign(including the raceway)
Take the total solid sign area and divide by the'Area per anchor'listed in the tables to determine required number of anchor PR�FF�S'
Anchor Capacities: DIRECTLY AGAINST
STRUCTURE
CSS aG ( NeF`S��
4(/ 72525PE P x
o VAX
ob
H M --
Plywood/Metal Siding 4SEP THROUGH
Fastening Options. NON-STRUCTURAL
1)Snap Toggler with Threaded Rod EXPIRES:12-31-2016 FINISH
2 912 wood or metal screws
Anchor Size Plywood or Metal Siding Area per Area with non- Soled area of sign(including raceway): 41.15 R` R E�E I V E D
Tension Shear anchor,ft' structural finish Allowable area per anch 7.7 ft'per anchor
912 Screw 66 106 10.9 3 m_tium 9-otart% 6 anchors(min SAN 2 6 2016
0.25 70 120 11.8 3.2 Use 6 anchors
0.375 195 140 21.3 7.7
0.5 230 160 24.6 9.1 c A
Notes.1)Metal Siding(without plywood)to be minimum 24ga thick. CITY Of TIGARD
2)The non-structural finish to be no more than 2'thick Al-die 3/8" DIA. SS ROD WITH SNAPTOGGLPLTt *_NGINEERINC
pipe is required at non-structural finishes EXISTING SIDING AND METAL STUD, TYP. (8)
LOCATIONS, PROVIDE 1" DIA. PIPE SPACER
BETWEEN RACEWAY AND SIDING
• 11'-10'
. I
27"
39 1/2" ,
An
8-1/2"
General Notes:
1)Unless there is an anchorage option for non-structural finishes.there is to be no gap between the structural support and the sign framing.
2 Tables are for the anchorage of the sign to the building only The design of existing structure and sign framing is not a part of the scope of these tables
3)Waterproofing of the connection is to be designed by others
4)When using a manufactured fastener,follow all requirements and recommendations listed by the manufacturer.
5)Anchors exposed to the weather or in contact with aluminum to be adequately protected to prevent corrosion.
6)Tables assume sign is located in a building comer zone and that the center of the signage is located above the center of the raceway
7).1 the sign is located outside'0 1-building width'from the corner,multiply the square footage values times 1 25
6)The anchors are to be equally distributed along the top of the raceway
9)A minimum of two fasteners are required at the top of the raceway and the hoizontal anchor spacing is not to exceed 6'o c
9570 SW Barbur BlvdProject Name Project#
Express Raceway Connection 160049
_
Suite One Hundred
1ri Portland,OR 97219 Location 10115 SW Nimbus, Suite 500,
Client Security Signs
MILLER phone 503.246.1250
CONSULTING Fax 503.246.1395 CJ M 1L+N.—t 1/22/16 1 of 1
www.miller-se.com By Ckd Date Page
ENGINEERS