Report (2) q
-N r
Real-World Geotechnical Solutions
=d Investigation• Design•Construction Support
November 23, 2015
Project No. 12-2704
Stonebridge Project No. 1857 r�
Stonebridge Homes
4230 SW Galewood St., Ste. 100
Lake Oswego, OR 97035
Fax 503-387-7615
Email AndyQ_stonebridgehomesnw.com; JiraDO-stonebrid-gehomesnw.com;
kristen(MOdmhholdingsco.com
RE: FOUNDATION SUBGRADE REVIEW
SOUTH VIEW SUBDIVISION LOT 20
12087 AUTUIIINVIEW STREET
—BARD, OREGON
References: GeoPacific Engineering, Inc., Geotechnical Explorations, Knauss Property
Subdivision, 12035 Southwest Beef Bend Road, Washington County, Oregon, report
dated August 10, 2012.
GeoPacific Engineering Inc. vipited the site on yesterday to review the single family home foundation
subgrade on Lot 20. We understand that the proposed building is a two-story home, garage under
layout on an upward sloping lot. In our opinion, the observed subgradd-Js generally adequate for
support to an allowable bearing pressure of 1,500 psf. The expected maxirrilom anticpated total and
differential footing movements (generally from soil expansion and/or settlement) art 1 inch and %
inch, respectively, over a span of 20 feet.
At the time of our site visit, the excavation was nearly complete. The excavation consisted of
predominantly very stiff4residual soil that could be probed less than 6 to 18 inches with heavy -
pressure using a steel." " bar probe. These soils are considered adequate to support the planned
foundation loads. Footing-to-slope setbacks were adequate and foundation embedment depths
appeared adequate. Some structural backfilling will likely be required.
Due to rocky and silty soils encountered throughout the site, all foundations should incorporate
appropriate drainage measures. Crawlspaces should be provided with a low-point drain and pass
through pipes should be installed through footings which would otherwise restrict water flow to the
low-point drain.
Care should be taken to avoid saturation or disturbance of footing subgrade soils during and after
excavation. If footing bearing soils become saturated or disturbed, any softened soil or slough
should be removed and replaced with crushed aggregate or additional concrete.
14836 SW 72nd Avenue Tel (503)598-8445
Portland,Oregon 97224 Fax(503)941-9281
Project No. 12-2704
South View Lot 20
Our work scope pertains to a geotechnical engineer's foundation excavation review only and the
conditions existing and exposed at the time of our site visit. Within the limitations of scope, schedule
and budget, GeoPacific attempted to execute these services in accordance with generally accepted
professional principles and practices in the fields of geotechnical engineering and engineering
geology at the time the report was prepared. No warranty, express or implied, is made. If you have
any questions, please call.
Sincerely,
GEOPACIFIC ENGINEERING, INC.
-x3 PRpF�ss!
5 NFA
47
OR GO
.23
D.tri`
=XPIRES:06/30/20f Z
James D. Imbrie, P.E., G.E.
Geotechnical Engineer
-2-