Loading...
Plans FEBRUARY 14, 2012 Standard Gable End Detail RECE P ST-GE110-001 DEC Mrrilk USA.Inc. Rage / of 2 11 �� Typical x4 L-Brace Nailed To - ✓_-_ I ( 21t Vsnicala W/10d Nailer,8'o c T, Vq Stud Vertical S!40 • 1°°'�""1OA-� �_UIL � DuooNeL MITek USA, Inc. 4 • =� _16d common SECTION B-B Wke NaYa DIAGONAL BRACE - /_ _' - Spaoetl6'o.C. AVO U.C.MAX J (2)-led Common .. arc find n Wire Nado into 2xe 2"Nog M belles f' TRUSS ARE FOR ILLUSTRATION CONDITIONS �"�. SHOWN ARE FOR ILLUSTRATION ONLY. Typical Hudxwaal Brace ,\ hlNled To Zx_Vedicals l 12 SECTION A-A e144 W[4)-lOd Carron Neils -� Varies to Common Truss INDIVIDUALMITEKPROVIDE 2x4 BLOCKING BETWEEN THE FIRST sad DRAWINGS FOR DESIGN ENGCRITINEERING TWO TRUSSES AS NOTED. TOENAIL BLOCKING ' 'A \ NAILS AT EACH END. ATTACH DIAGONAL TO TRUSSES WITH BRACE O BLOCKING WITH ** \\\ (6)-tOd COMMON WIRE NAILS. / B 8 3z4 (4)-Bid NAILS MJIK %%i i 1'i-i /i/iii/i i%L.L%%/% SHEATHING TO * -Diagonal Bracing ** L-Bracing Rotor Refer to Section A-A b Section B-B 24-max] Roof Sheathi NOTE: 1.MINIMUM GRADE OF e2 MATERIAL IN THE TOP AND BOTTOM CHORDS.2.CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS ANDWALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 1 � `3.BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY.CONSULT BLDG. MBx. IARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT (2)-10d NAILS BRACING OF ROOF SYSTEM. 4.•L•BRACES SPECIFIED ARE TO BE FULL LENGTH. GRADES:1x4 SAB OR 2x4 STUD OR BETTER WITH ONE ROW OF ted NAILS SPACED B•O.C. 5.DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF ^DIAPHRAM AT 4'-0'O.C. S (W 24" D.C• 6.CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 STUD AND A2x4 STUD AS SHOWN WITH led NAILS SPACED e•O.C.HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST STUD. ATTACH O VERTICAL STUDS WITH(4)ted NAILS THROUGH 2x4. 2(8 DIAGONAL BRACE SPACED 49"0.0 (REFER TO SECTION A-A) Diag. Brace ! ATTACHED TO VERTICAL WITH(4)46d 7. GABLE STUD DEFLECTION MEETS OR EXCEEDS L1240. at 1/3 Point COMMON WIRE NAILS AND ATTACHED e. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. if needed "/ TO BLOCKING WITH(5)-11)11 COMMONS. 9, DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE TRUSSES. Fi End W aii - — — HORIZONTAL BRACE \�\ (SEE SECTION A-A) 2 DIAGONAL Minimum glad VNthout Tx4 B2K4rs DIAGONAL BRACES AT Stud Spe Size cies Spacing Braes L-Brace I L-Braq BRACE 1/3 POINTS and Grade �Mudmsin Stud Length SPED PRO 2x4 SPF SW&W 12.O.C. 4.6-3 1 5-0-7 1 7.1.7 1 9.0.5 I 13-6-8 g1 1N 2x4 SPF SwStua 16.O.C. 413 4-4-5 1 6-2-0 8-2-7 12-3-10 I G1 2x4 SPF StdlStud 24.O.C. 3.5.8 3.6.11 5-0-7 8-10-15 10.4.7 S P )k Diagonal braces over 6'-3'require a 2x4 T-&ace attached to one edge. Diagonal braces over 12'8•require 2x4 I-braces O 7/1/zr- attached to both edges. Fasten T and 1 braces to narrow edge y r:.,-_GON '� kr of web With ted common wire nails Bin o.c.,with 31n minimum end(is lance. Brace must cover 909;of diagonal length. �Q 'Y 14 F?R; 9 MAX MEAN ROOF HEIGHT-30 FEE r CA It GORY II BUILDING ����� EXPOSURE BaC EXPIRES 1 e„4//s. ASCE 7-99,ASCE 7-02.ASCE 7-05 710 MPH - -- - ASCE 7.10 140 MPH STUD DESIGN IS HASEO ON CUMPONENTS AND CIAO ING. DURATION OF LOAD INCREASE:1.60 CONNECTION OF BRAGING IS BASED ON MINERS. FEBRUARY 14, 201 Standard Gable End DetailT SHEET 2 _ — 1 _- - — -, MITak USA,Inc. Page 2 of 2 VIII III CR ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD o� Trusses @ 24" o.c. l HORIZONTAL BRACE 2x6 DIAGONAL BRACE SPACED 4e'0.0. (SEE SECTION A•A) CATTACHED TO OMMON WIRE ERLS AND I T 14&d MiTek USA,Inc. Roof Sheathing-� ` TO BLOCKING WITH(S)-10d COMMONS. T-3" Max. IT IS THE RESPONSIBILITY OF THE BLDG DESIGNER OR NAIL DIAGONAL BRACE 70 THE PROJECT ENGINEER/ARCHTECT TO DESIGN THE PURUN WITH TWO t6d NAILS THAT CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE MAY RESULT FROM THE BRACING OTRUSSES TO RESIST ALL OUT OFLF THE GABBLE ENDS 2X4 PURUN FASTENED TO FOUR TRUSSES WITH TWO 16d NAILS EACH.FASTEN PURIM \ TO BLOCKING W/TWO 16d NAILS(MM) '.. Diag. Brace. \ PROVIDE 2x4 BLOCKING BETWEEN THE TRUSSES at 1/3 points SUPPORTING THE BRACE AND THE TWO TRUSSES ON ERNOTED TOENAIL if needed \ TO Rr USSESIW ITH4(2)-10d NAIILS AT EACNCENDG ATTACH DIAGONAL BRACE TO BLOCKING W ITH -.: (5)-10d COMMON WIRE NAILS. End Wall t CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: STRUCTURAL METHOD i :ATTACH A MATCHING GABLE TRUSS TO THE INSIDEGABLE TRUSS FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE t �. FOLLOWING NAILING SCHEDULE. { �.. -` METHOD 2:ATTACH 2X SCABS TO THE FACE OF EACH VERTICAL SCAB ALONG MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING VERTICAL ----- NAILINGh SCHEDULE.SCABS ARE TO BE OF THE SAME SIZE,GRADEn,I AND SPECIES AS THE TRUSS VERTICALS NAILING SCHEDULE: -FOR WIND SPEEDS 120 MPH(ASCE 7-90,02,051,150 MPH(ASCE 7-10)OR LESS,NAIL ALL MEMBERS WITH ONE ROW OF 10d(.131"X 3n NAILS SPACED 6'O.C. -FOR WIND SPEEDS GREATER 120 MPH(ASCE 7-W 02,05),160 MPH(ASCE 7-10)NAIL ALL /l MEMBERS WITH TWO ROWS OF 10d(131"X T)NAILS SPACED 6'O.C.(2X 4 STUDS MINIMUM) MAXIMUM STUD LENGTHS ARE LISTED ON PAGE i. Lam.-• /,/• ALL BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR INLAYED STUD /i' / VERTICAL STUDS OF THE STANDARD GABLE TRUSS �/ ON THE INTERIOR SIDE OF THE STRUCTURE. STRUCTURAL I ! AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST GABLE TRUSS I BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.THE BRACING SHOWN IN THIS DETAIL IS FOR THE VERTICAUS I ) 01 PR0FFSc \yC �NGINEEm /0 NOTE:THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS.TRUSSES INLAYED !7 STUDS ARE NOT ADDRESSED HERE. / STANDARD / GABLE TRUSS l - 1 1 11-24-15 Roseburg J2 11:4848am tI'- I .......... 1of1 CS Beam 4.13.0.3 k"toonEngine 4.13.1.1 Materials Database 1519 Member Data Description: UPPER Member Type: Joist Application: Floor WORST CASE MULTI SPAN Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code BC/IRC 1-five Load: 40 PSF Deflection Criteria: U480 live, U240 total ]l Dead Load: 12 PSF Deck Connection: Glued&Nailed E� IVL1 1 ,T Filename: Beam3 Joist Design Includes CCMC Vibration Check Subfloor:3/4"OSB DEC 17 2015 Ceiling: 1/2"gypsum Blocking:(See Requirements Below) CIM)FRIGARI) BUILDING DIVISION 1510 8 5 3 8 12 5 8 m 3378 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 530# — 2 15,10.500" Wall DFL Plate(625psi) 3.500" 3.500" 1346# — 3 21' 2.000" Wall DFL Plate(625psi) 3.500" 3.500" 949# -17# 4 33' 7.500" Wall DFL Plate(625psi) 5.500" 1.750" 436# Maximum Load Case Reactions Um For apploo,,poim load.(or lire bads)to®,ryi„p members Live Dead 1 408#(255plo 122#(76plo 2 1078#(674plo 269#(166plf) 3 - 807#(505pif) 141#(88p10 4 336#(210plf) 99#(62plfl Design spans 15' 5.875" 5' 3.500" 12' 0.875" Product: 117/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS Blocking:(None) Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1666.# 3640.# 46% 6.58' Odd Spans D+L Negative Moment 1929.# 36404 52% 15.88' Adjacent 1 D+L Shear 768.# 14204 54% 15.86' Adjacent 1 D+L End Reaction 530.# 1420.# 37% 0' Odd Spans D+L Int.Reaction 1346.# 1935.# 69% 15.88' Adjacent 1 D+L TL Deflection 0.1960" 0.7745" U948 7.36' Odd Spans D+L LL Deflection 0.1516" 0.3872" U999+ 7.36' Odd Spans L Vibration 0.0228" 0.0427" 53% Control: Max Int.React. DOLS: Live=100% Snow-115% Roof-125% Wine=160% M'oodct oamesaretademaAsottha'onpxv,. mea Eric Duncan ® byPacific Lumber&Truss Co. Capy,ghl(L)3015 eimpwn ShapTie Cwnpe,ry Inc.ALL RIGHre RESERVED. 10515$W Allen Blvd. 'Taai,g b defined m�en me memoor,moor blot,beam or glider,&irnai on the load,,meats applicade design cnlena for Loads,Lcadl,g C ilimre,and spas listed oo Mia meat The design Beaverton OR 97005 rust W feWo-aed by Qualified designer or dealgn pmlmaionel as r irm for appmsal.This design sew mpmdud ire heron ecmrdi,g to the maouraaum:s spacRrat'ro (503)793-8368 nnnd(nlnaclumhnr r nn 15 Roseburg 3 _24_ 11:50am 1 1""',1>n,.In.h r,,,y,.. 1 of 1 CS Beam 6.13.0.3 kmHeamEogine 4.13.1.1 Materiels D".1519 Member Data Description: UPPER Member Type:Joist Application: Floor SINGLE SPAN Top Lateral Bracing:Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: U480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Bel 1510 8 m 0 1510 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 641# — 2 15'10.500" Wall DFL Plate(625psi) 1.750" 1.750" 641# Maximum Load Case Reactions Used for at,,Ipg pdnl Wads(or lino wads)W ini ing member Live Dead 1 493#(308p10 148#(93plo 2 493#(308p10 148#(93p10 Design spans 15' 5.000" Product: 117/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each tearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2472.# 3640.# 67% 8.09' Total Load D+L Shear 641.# 1420.# 45% 0' Total Load D+L End Reaction 641.# 950,# 67% 15.88' Total Load D+L TL Deflection 0.3321" 0.7708" U556 8.09' Total Load D+L LL Deflection 0.2555" 0.3854" L1724 8.09' Total Load L control: Pos.Moment DOLS: Live=100% Snow--115% Roof-125% Wind=160% At predud remes e,e tinso ea their respedi"e wens Eric Duncan ® Coloydghl(C)M15by Simpmn Str The Company Inn.M RIGHTSRESERVED. Pacific Lumber&Tmss Co. 10515 SW Allen Blvd. -Pass,le defined.*,on Itne member,floorjoist beam or girder,shoran on this drexinp meets applicable del m ede for Loatls,Loading caMition,ant Sirens lisled on this sheat.The design Beaverton OR 97005 nine be ollaed by a qualified designer or design professional as required for t,o 1.This des,aswmes pmduct installation arwming to the maradadunel spedfi®florin. (503)793-8368 .HM(nlnerlum her cnm C,Roseburg 3 @ CANT. -24- 5 11:Slam 1 of 1 CS aemn 4.13.0.3 knlBan eEngille 4.13.1.1 Mazenals Database 1519 Member Data Description: UPPER Member Type:Joist Application: Floor JOIST @ CANT. Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: U480 live, U240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam1 Other Loads Type Other Dead (Description) Side Begin End Start End Start End Category Point(PLF) Top 14' 9.00" 50 35 Snow Point(PLF) Top 14' 9.00" 0 100 Live x 1390 1 00 0 y 14 9 O Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 1.750" 1.750" 552# — 2 13' 9.000" Wall DFL Plate(625psi) 5.500" 3.500" 887# — Maximum Load Case Reactions Used far applying pdd bads(w line loads)to canyirg members Live Snow Dead 1 438#(274plf) -5#(-3plf) 115#(72p1f) 2 504#(315plf) 86#(54plo 383#(239plo Design spans 13' 8.125" 1' 0.000"(right cant) Product: 117/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assurnes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1833.# 3640.# 50%d 6.91' Odd Spans D+L Negative Moment 310.# 4186.# 7% 13.75' Total Load D+0.75(L+S) Shear 587.# 14204 41% 13.74' Total Load D+L Cant.Shear,Rt 299.# 1420.# 21% 13.75' Total Load D+L End Reaction 552.# 950.# 58% 0' Odd Spans D+L Int.Reaction 8871 2135.# 41% 13.75' Total Load D+L TL Deflection 0.1974" 0.6839" U831 6.91' Odd Spans D+L LL Deflection 0.1632" 0.3419" U999+ 6.91' Odd Spans L TL Defl.,Rt. -0.0373" 0.2000" 21J643 14.75' Odd Spans D+L LL Defl. Rt. -0.0327" 0.2000" 2U732 14.75' Odd Spans L Control: Max End React. DOLS: Live=100% Snow=115% Roof--125% Wind=160% Right cantilever allowable shear is for joist only alvmdad names am erademaMadmar respective aanen Eric Duncan ® rtmRLL Pacific Lumber&Truss Co. CopyngM1l(C)2a15 by Slmlcon GlyT'n Company Inc. RIGHTS RESERVED. 10515 SW Allen Blvd. "Passing Is"ma ss even 1M10 memner,etsmidd,beam ar g ra.,sM1om on this dnvn,g meets applicable design Meana far Weds,Laas g Gonamims,and Spare listed on mis snag The design Beaverton OR 97005 nus unmeas.9d by a qualified designarord agn prMeeaiarel aamuiredfmappmvd.Pnisaesgn assumespMad inatanatbn a.alingroma mandedusersapedlicstiaw. (503)793-8368 aanrrlGli narh Imhar rnm