PFI2015-00187 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12015-00187 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 01/20/2016 Parcel: SEG1115 Jurisdiction: Site address: Subdivision: Lot: Project: ELI -Integra Project Description: Proposal to place fiber from existing vault on the NW side of SW Burnham St. through existing conduit to R/R 6'x 6'section of sidewalk place 17"x 30"vault. Place(1)2"conduit, locate wire, and fiber 77" (NW)by directional bore and trench 3.5 feet. Owner: FEES Description Date Amount PFI Permit Fee 01/20/2016 5300.00 PHONE: Contractor: PHONE FAX Applicant: DAVID MINER 18110 SE 34TH ST. BLDG 1. SUITE 100 VANCOUVER WA, 98683 PHONE: 503-710-6290 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant i Signature: f'n ec Issued By: "I c1 ILL, b�-eb Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12015-00187 Type: Condition Name: Status: Severity: PFI—Utilities 21 -OTHER Not Met Notice Mark extents of concrete removal and notify the City's Inspector twenty-four(24)hours prior to commencing work. 0Cite Of Tigard. a PUBLIC NVORKS—ENGINEERING C Public Facility Improvement (PFI) Permit DESCRIPTION OF WORK (in the right-of-way) REQUIRED SUBMITTAL Check one: ❑ Utilities ® Sidewalk/driveway approach ❑ Street improvements ELEMENTS Detailed description: Integra proposes to place fiber from existing vault on NW side of ❑ Minor work in right-of-xvay (sidewalk repair,curb cut,street SW Burnham St.through existing conduit to R/R 6'x6'section of sidewalk place 17"00"vault. opening,etc.)requires: Place(1)-2"conduit,locate wire,and fiber 77'(NW)by Directional Bore and trench 3.5'. •and signed form,completed and signed •Submit one(1)copy of scaled sketch Propert)- address/location(s): of the proposed work to be done 9180 SW Burnham St, Tigard, OR 97223 •Submit one(1)copy of traffic control plan SEG HIS –OR– ❑ Substantial project work requires Applicant's iinmc: ELI-Integra- Dave Miner above items and professional .:address: 18110 SE 34th St, Bldg 1, Ste 100 engineered plans for: •Street widening Clc\'/state: Vancouver, WA Zip: 98683 •Subdivision infrastructure. Phone: (503) 710-6290 F:mail: David.Miner@integratelecom.com •\lain utility line extension: Storm Drain,Sanitary—Tigard - water—"figard\Carer Service Contractors Warne.: Standard Utility- Darrel Williams .\rea (includes Durham,King City 1 xpiration: and a portion of unincorporated CCB#: # 66948 \C-ashington County) Address: PO Box 1008 Salem, DELIVER APPLICATION TO: City/state: OR Zip. 97308 City of Tigard Phone: (503) 678-3030 Email: _ Planning/Engineering 13125 SW Hall Blvd. Tigard,OR 97223 Engineer's name: \pplicanona for"minor work in right-of-way" Address: __ unlc mac be emailed ro: City/state: Zip: rocv�ermits(d tigard-or goy Phone: I-'mail: FOR ONIA Case No.: P F1 a 015 —pp 1 b 7 Estimated value of work (within the public right-of-way): S Application sulnnitral fee: Is work related to a L,-\ND-USE DECISION? ❑ Yes 8 No Application accepted: If so, please specify (NILl,SDR,SUB, etc.) case #: By: M-C' Date: Applicati n re. Td: Is Is work related to a BUILDING PF.RNIIT? ❑ Yes R No / By: llate: I U /� If so,please specify(BUILDING PERI\111)case#: Applicant notified: / Iiy:__L_— Date: - S 1\CURPLN\Masters\Land Use Appl-bons Rev 07/16/20r4 2-4 1,,- k- City of Tigard •/131245 SW Hall Blvd. • Tigard,Oregon 97223 • -,vv, ?.tigard-or.gov • 503-713-2421 • Page 1 of 4 APPLICANTS NOTE: Person specified as `Applicant" shall be designated"Perinittee"and shall provide financial assurance for work. wlwn the owner and the applicant arc different people,the applicant must he the Purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(>)nmst sign this application in the space provided ur submit a written authorization with this application. BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT: • The-above request does not v iol9te arts deed restrictions that mav be,Attached to or imposed upon the subject oroPert • If the application is granted,the applicant-,.ill exercise the rights granted in accordance xvith the terms and subject to all the conditions and linnitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true-,and the applicants so acknowledge that ani,permit issued,based on this application,may be revoked if it is found that ani, such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. S NATURES of each owner of the subject property required. )Sib J —?, f1w PS 4F�L A plicant/1.1ut sized Agent's signature Print name D Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City 0f Tigard • 13725 S\\'Hall Bh-d. • Tigard,Orcgou 97223 • \\,xvNa.tigard-or.gov • 503-718-2421 • Pdge 2 of 4 DEVELOPMENT ENGINEERING FEES 1. Public Facility Improvement(PFI) Permit: Part 1: Required submittal fee$300.00 Part 2: All non-water system improvements Engineer's estimate X 5%(less 5300.00 submittal fee) Engineer's estimate X 2°ju Plan Review Part 3: All public water system improvements Engineer's estimate X 12% Total Permit Fee= Part 2+ Part 3 PFI Permit Fee Exemptions: 'there will be no permit fee charged,or assurance required for the following types of work: • Sidewalk or driveway repair(less than 20 lineal feet) • Relocate or replace mailbox • Ditch cleaning that does not involve regrading. • Weephole repair • Curb repair or replacement(fess than 20 lineal feet) • Lawn sprinkler system installation or repair • Street tree pruning or planting • Planter strip landscape maintenance • 'lest wells ,6), 1A ntk) 4V4 - �artC�c�C. Ic�%kiz ntct� L `� X� PUBLIC FACILITY IMPROVEMENT PERMIT Cityof Tigard 1312.5 S\\'f ial!Blvd. • Tigard,Oregon 97223 • -%k-\%-w:tigard-or.gov iO3-7118-2421 Page 3 of 4 Cheryl Caines From: Justen Phillips <Justen_Phillips@kbmail.net> Sent: Monday, December 14, 2015 2:16 PM To: ROW Permits Cc: Miner, David (David.Miner@integ ratelecom.com); Roy Spaulding;Jeff Mettert Subject: ELI/Integra Fiber enhancement permit application. Attachments: Permit Application-Fiber Enhancement_ES015-2810 (INT-6056-4010) signed.pdf, Permit Drawing_ Fiber Enhancement_ES015-2810(INT-6056-4010).pdf, Diag 300 - Shoulder Work with Minor Road Encroach ment.pdf Good Afternoon, Attached is a permit application, Drawing, and TCP in which ELI/Integra is proposing to place new facilities under the back of the sidewalk on SW Burnham St. Please see drawing and application for more details. Please call or email me with any questions or concerns. Thank you, Justen Phillips Project Manager K&B Technical Solutions 6566 SE Lake Rd Suite E Milwaukee, OR 97222 Office - (503)650-6041 Fax - (503)650-7390 Mobile - (971)271-9317 i 2011 Edition Page 81 Shoulder Work w/Minor Road Encroachment _ `Diag 300' ROAD WORK to AHEAD • Initial Warning A • Sign • • • (Optional) • • Protection Vehicle • w/TMA(both Optional) Buffer See Chapter 4 I • 10' • minimum • U3 • A VNARROWS NN (OptionaD B ROAD WORK AHEAD Initial Warning Sign December 2011 Chapter 5 �Y sf h\Y� \ Sf 4\ •P \ �i^k \ Sf Yr9 \ k �,k \ TRENCH A MINIMUM OF 36" BELOW sfk GRADE AND PLACE 2" CONDUIT, LOCATE WIRE, AND FIBER. \ �k � sf� EX11 C11Y OF TIGARD ROW--_ Pp FY TRENCH 3.5'� REMOVE/REPLACE 6'X6' \ Y SECTION OF SIDEWALK. \Y� 18' SIDEWALK sf 4 DIRECTIONAL DRILL/BORE A MINIMUM OF 36" BELOW GRADE AND PLACE 2' ♦ Oh CONDUIT, LOCATE WIRE, AND FIBER. O 4 ♦ '� �Y \ 441 \ \\ / EXISTING INTEGRA VAULT TO BE DUG UP AND MOVED INTO \\ ♦ I / ROW AS SHOWN IN DETAIL REMOVE/REPLACE 6'X6' SECTION OF SIDEWALK. 0' 20' 40' SCALE: 1" =20' CONSTRUCTION NOTES 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR BETTER a CONDITION. 2. ALL OTHER UTILITIES ARE BASED OFF EXISTING LOCATES OR UTILITY STRUCTURES. DEC 14 2015 3. IT IS THE CONSTRUCTION CONTRACTORS RESPONSIBILITY TO CALL FOR LOCATES BEFORE DIGGING. FLA`' '' ._ _ .,_`r?NG LEGEND DIRECTIONAL DRILL - EXISTING CONDUIT — — PROPOSED INTEGRA VAULT EXISTING VAULT FTI RIGHT OF WAY FACE OF CURB/ EDGE OF PAVEMENT EXISTING SEWER EXISTING INTEGRA 25TA VAULT EXISTING WATER —WrH BORE AND/OR RECEIVING PIT �__J P��r;('.I N r�0` 1 C' REMOVE/REPLACE SIDEWALK FLAG �__J -PUSH/PULL FIBER THROUGH EXISTING INTEGRA 4" CONDUIT J' integra � Contact:David Miner 4- Title:Sr.OSP Engineer BG ph:(360)5584213 cell:(503)710-6296 941 \ email:David.Min erlci�integratelecom.corn l PO BOX 2529 ` Clackamas.OR 97015 .Sf R k sf \ Design By:K 8 B(503)650-6041 TECHNICAL SOLUTIONS Email:Justen_Phillips@kbmail.net REV. DATE DESCRIPTION DRAWN DESIGN \ rf k 1 12/11/15 CITY OF TIGARD PERMIT DRAWING RAS J.P. ,y \ rf k \ 1b.may., \ Sfk SCAI F PROJECT NUMBER: A�\ 1" =20' ESO 15-2810 Sfk sfSHEET NUMBER TITLE: t \ Fiber Enhancement Project \ 9180 SW Burnham St. f \ Tigard, OR 97223 \\ \ FILE NAME. D \ °F 1 INT-6056-4010 f, Page 80 2011 Edition �ShotalcJe�;Work,w/:MinorrRoad Encroachment . ,Diag.'300 Use this detail for non-freeway work which extends into a travel lane and maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane can not be maintained, or when traffic can not safely pass by in both lanes simultaneously, use the appropriate lane closure diagrams—for example, Diagrams 310 through 350. A lane closure may be appropriate for conditions such as high traffic volumes, high speeds, and inadequate approach sight distance to the work space, or heavy equipment adjacent to the travel lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Cones shall be placed along the entire length of the work space. If a protection vehicle is used and work is in place one hour or less, the taper and tangent devices may be omitted. 4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there is limited sight distance, consider placing cones or tubular markers on centerline. 5. An arrow board in caution mode or truck-mounted PCMS with "SHOULDER WORK" or other appropriate message may be used for higher visibility. Sign Spacing and Buffer Lengths(feet) Posted Spacin .Between Si ns_ - _ Buffer Speed - A B C Space 20 50 25 100 100 100 75 30 100 35 125 40 350 350 350 150 45 180 50 .500 500 500 210 55 250 Chapter 5 December 2011