Loading...
Plans RECEIVED b ; 2 3 2015 Avg4 m _ CITY OF I BUILDING DIVISiUfq � W Q pm 0" SCO 94' 30' 25' 26' 1/4" 39' Deck CITY OF TIGARD Approved by Planning 108' 3/8" Date: ' 3 /S' House Initials: LS 13235 SW GENESIS LP TIGARD OR 97223 Scale 1/16" = 1' So ��-�� -����y i 0 Pr,OF y� aciNt °�r, 648 STRUCTURAL 51RR14ARY: 2 X 8 LECGQR RECEIVED � I S ®� o ' NEW RESUMMAR A M. FRAMED WITH PRESSURE-TREATED o \v/ �s LUNBER AT WEATHER-RESISTANT 2X DECKING. ; o w.�F�, b 31 IS CODEEXPIRES:Ia RFAUIRENENTS: j� •1.6 CONFORM TO THE REQUIREMENTS OF THE 2014 OREGON e bat ' ` DEC 2 3'2015 2015 SIRJC LRAL SPECIALTY Com,WITH STATE AND LOCAL AMENDME"Si • 2I VENCITY OF TIGARD OES1 XSI NISABASED ON THE TM AND MUCTION ?X PECKING '8'-8• 9-6' ;;'; BUILDING DIVISION CRITERIA OF THE ABOVE-REFERF1M CODE. IN AIA- ITION TO THE DEAD LOADS.THE FOLLOWING LOADS WERE SEE STRUCT NOTES—\ WUSEII: SNOW: Pg=25 PSE. Pf= 16 PSE, /it//' /���/'� 4 X d DIAG BRACE t f;, ii. i Ce=0.9. Is = 1.0. Ct=1.0 2 X 8 LEDGER ALLOWABLE SOIL BEARING! 1500 PSF SEISMIC: RISK CAT. 11. le= 1.0. SITE CLASS D / %i", ',i, i.;'. ?.1.2X o\6 0•� Ss= .961. S1 = .400HEM+IR lN1 2 A15 I R SDS=0.72.SDI =0.43. SDC='D' $ BRACED WOOD FRAMES. R=3.5OVERSTRDCM FACTOR= .0 K6 8 EDJ[V. LATERAL FORCE 3PROCM);E I p 691` 5 GENERAL: ALL DETAIL CUTS S 40LU BE CONSIDERED TYPICAL AT - LIKE CONDITIONS. 4 X 6 DIAG BRACE P.T. 6 X 10 HEM-FIR CCUR *iERE ANY DISCREPANCIES OBETWEEN PLANS.DETAILS. r NOTES AND IFICATIINS. THE GREATER REQUIREMENT b m 7 NO. 2 BEAN L (_l u N y0\SSS a A. \g C• ESTABLISH AND VERIFY ALL GEOMETRY FOR ARCHITFAIURAL. \R tu'2 r; K MECHANICAL, ELECTRICAL, AND PLUtffiING COURNS PRIOR I 2Y TO CONSTRUCTION. lN1 P t THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING 1 i CONDITIONS. DIMENSIONS. AND EEEYATIONS SHOWN IN THE PLANS. AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 6 i 6 DECKING 12`-0" SEE STRIJCT NOTES - THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STRUCTURAL P.T. 6 X 10 HEM-FIR NO. 2 BEAM STABILITY OF ALL NEW AND EXISTING STRUCTURES MING CONSTRUCTION. THIS INCLUDES EXCAVATIONS. M-LIMNS. EMIMENT I=. MATERIAL LOADS. AFD OTHERS. OBSER- VATIONS BY a ENGINEER 00 NOT INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING(DNSTRiGTION. SAWN LIMBER: ALL LU48ER EXPOSED TO WEATHER SHALL BE PRESSURE-TREATED HEM-FIR OF THE FOLLOWING GRADES U.N.D: 4 X 6 4IAG BRACES JOISTS.PLATES.LEO(£RS.BLKG; NC.2 28'-Y BEAMS AND POSTS: NO.I (n PRESSURE-TREATED LIMBS : Q ALL LUIBERR IN CONTACT WITH CONCRETE SHALL BE PRESSURE-TREATED. J FOLLOW ALL WR RE(XMFTDATIONS REGARDING COATINGS ON FASTENERS _ PLAN AMC LIGHT GAGE PLATE CONNECTORS IN CONTACT WITH TREATED WOOD. B ELEVAT f ON 3/16' = I'-o' 3 CONCRE MIX:DESIGN: PREPARE DESIGNS FOR EACH TYPE OF CONCRETE, m PROPORTION NIXES BY EITHER LABORATORY TRIAL OR FIELD EXPERIENCE. FURNISH CERTIFIED REPORTS FOR EACH PROP- OSED MIX, AIR ENTRAINING AGENTS PER ASTM C250 AND WATER-RFOJCING ADNEXTiME PER ASTM 494. USED ACCORDING r TO MFR SPECS, MAY BE INCORPORATED. AIR ENTRAINMENT'PER H ASTM C260 SHALL BE USED IN NIXES FOR EXTERIOR HORIZONTAL >ec :, GROSS BEAM a BRADS SURFACES EXPOSED TO WEATHER,AND SHALL BE 5%-7X BY VL. (ROSS BEAM:BRACE -FLY-ASH SHALL NOT EXCEED 15X OF CEMENT CONTENT BY WT. ! 4 X 6 DIAG BRACES CONCRETE WORK SHALL CONFORM TO ACI 301. STRENGTHS OF I PREVIOUS MIXES SHALL HAVE BEEN VERIFIED BY SID. 28-ilAY CYLINDER TESTS PER ASTM C39 TO THE FOLLOWING: -FOOTINGS: 3000 PSI AT 28 DAYS.SJMP 3' +/- 1' + -SLABS ON GRADE: 2500 PSI AT 28 DAYS, SLUG'3' +/- I' CCPMTE ANONRS: e � (ATE ANCHORS SHALL BE SIMPSON STRONC80LT OR 2 I w EQUIVALENT AS APPROVED BY ENGINEER. w (U/7 U DECK SHEATHING: 2X6 IEIXING OR TIMBERIECH COMPOSITE MING. FASTER o EA JOIST v/(2)&7 X 3'On SCREWS 26• BRIARS FOOTINGS 2 X 4 BOTH SIDES AND(3)97 X 3' a BLOCKING AND LEDGERS, OR 30' DIA SINOTIIDE FT'GS 4 X d STRUTS r/(9)16d AS SOWN OR USE T1MBERTECH(YNCEALOC FASTENERS PER MER INSTALATION ISTTRLCTIONS. 0] C] FASTENERS; _ _ J L _ _ J _ _ J L _ _ J L _ _ J L _ _ J Z z ul ALL MAILS SHALT.BE CO9NON(U.N.01 v/FYb=90 KSI a ALL BOLTS AND THREAROES SHALL BE A307 OR BETTER m a m a DED PRE-ORILL 70%OF STAN(DIAMETER FOR LAG SKEWS : ALL LIGHT GAPE.META_CONNECTORS SHALL BE BY SINPSCN- SHEETREV: STRONGTIE AND INSTALLED PER MFR SPECIFICATIONS. S1.0 Y { J (2)08 X 3'a POSTSc ��PEProFi„ bap 11..aa9 4 X 4 GUARDRAIL POST I S : CFP a 84' MAX C-0 2 X 5 TOP RAIL. EXPIRESI 31 IS ORIENT GRAIN TO AVOID CUPPING 10 (2)08 X 3' o POSTS 2 X 4 TOP BOARD DEG(SCREWS a 8 o.c. zz N 2 X 2 PICKETS a 53x8' (2)08 X 3'a POSTS 2 X 6 BTM BOARD • 8 8 SIMP um - — JOIST PER PIAN ^,' DECK SCREWS a 4' o.c. (2)1/4' X 4'SIMP SDS r 12' A307 ALL-THUD RODS. NUTS. FENDER WM ; SIMP LU28 TYP i ° o P.T. 2 X 8 LED>GFR APPLIED TO DOTING o ° ° ° (3)08X3' OR RIN JOIST. 00 NOT APPLY OVER SIDING. BOTH SIDES OF BLK (E)WALL ° o ° ° o ° JOISTS PER PLAN _r LEDGER DETAILS c' 5 l-l2' = 1'-0' 2X Di<J(a DTM 6 1-12' = I' ' ' J STRUT(SORE LOCATIONS) P.T. POST PER PLAN , (N)SIMP ABA66Z OR ABA44Z � MfRANEO STEP W 5/8' X B' EMBEODm ANCHOR Q • ° e o I ' 3 Co SIMP OTT2Z l6d a 8' co DECK SCREWS a B° P.T. 2 X 12 � I I I I z I I iv I I a 16da8, % o _ ° ° COMPACT ANY REG'D 8 DF I L, - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BEAR]PER PLAN w w -0' SIMP MM FASIM TO w (S14 STRAP X 4' IINOERSIDE OF BEAM SM..RAILING 2X BLR'G FOR 3 BAYS 26' SURE 2500 PSI CONCRETE F7'GOR I 3D' DIAMETER FOR POST FJ�E@t7QT. SEE STRICT NOTES m o z vi at a > DECK OFFSET 8 TYP I CAL FOOTING 2'MSG DX)MPACTED ROCK OVER a 1-1/L' = 1'-0* )-12' = l'-0' UNDISTURBED NATIVE SOIL OR FILL SHEET: REV: COMPACTED 927 DRY DENSITY PER S .n _ r ' FED Pr.' yS`,,GINFF ss, - 2(OEf]([NG �(EQ(SCREWS a 8` o.e. � `` _ 3618 C EG �i eye A�. SAO W.GFA. FXPRESI 3I IS I.aol (6) lu BOTH SIDES Typ nwN JOIST PER PLAN P.T. O O a .T. 2X BLK'G r/ m (2) 16d TOENAILS — — — — — — — — — — — SIPS'H2.5A O O p(HOG OR 8 EVERY 01M JOIST BEAN PER PLAN •Z� O „ 8 O it p O 8 ~ p iI O O I BEAM PER PLAN . � . p i O O 3/4' MARINE PLYWOOD r SINP BC6(HOG OR SS) (5) 16d BOTH SIDES p GUSSET 80tH SIDES i BOTH BRACES r, STAGGER AS SHOWN POST PER PLAN P.T. POST PER PLAN U.Cl (7) 16d P.T.4 X 6 BOTH BRAGS t_u, 3 r !.I 1—r., SIDES a --x rn -3 �.�[_ ff1 iL C, U] )a. r J1 L'1 [1 7.0 C] C� L.1 W JOIST BEARINGr,. BRACE CONNECTION A (2)#8 X r a POSTS (n 4 X 4 GUARDRAIL POST a 64'MAX C-C 2 X 6 TOP RAIL. Q ORIENT GRAIN TO AVOID CUPPING J J (2)A8 X 3' a POSTS 4 X 6 BRACE 3 POST PER PLAN 2 X 4 TOP BOARD i (5) lu BOTH SIDES In BOTH BRACES O O O STAW AS SHOWPI m i O 3/4' MARINE PLYWOOD 2 X 2 PICKETS a 5-3/0' e e m i p i GUSSET BOTH SIDES f �O STS ti. p i O 4 X 6 STRUT �(2)68 X 3'a PO i t7)olt( ) 1 d 01 — — — — 2 X 6 BTR BOARD SIDES I � O O I I DRAINAGE HOLE O 0 SIMP OTT2Z w UU9 BO(H SIDE (3) ISIS 1/2' A307 ALL—THREAD N u RODS. NUTS. FEW WSHRS :110 0 0 0 0 0 � 0 I I o O o o }(a 0 0 0 z 3 N 0 JOIST PER PLAN BRACE CONNECTION �4 ARDRA[LS o Q Lu 1-12' = I'--0' SHEET: REV; Sl.0 - 3' w U) D O = CONCRETE LOADING HOUSE PT 2X6 HEM-FIR BEAM RT 2x8 LEDGER ccw CC U w NSM F S 6' � 00 N O = ti PT. 4X8 HEM-FIR BEAM 14' MF E N P.T. 2X6 DIAG BRACES 6-4 1/4" PT. 4X8 HEM-FIR BEAM 1'-7 3/4" 6-9 7/8' X CEDAR DECKING 6-7 1/2" FASTEN EA JOIST W/(2)#7X3"DECK SCREWS a � SIMPSON DTT2Z 4• simpson strong-6e 1/2"bolt washer and nut p t.2x6 diag brace mpson strong-tie F13235 PROJECT FOR: 12/22!15 BOB WILLIAMS CONSTRUCTION CO. 21446 SW CHRISTENSEN CT CE MCKINNEY TUALATIN OR 97062 SW GENESIS LP TIGARD 97223 503-260-4634 CCB#207042 GUARDRAIL POST ATTACHMENT 16"Min. DF;TAIL A(Figure 31) /J_ D 1"F2L deck jui.l pegtcndicular to guardrail t/ 4x4(min.)guardrail post al 48"o.c.(mnx.) I 'O 2xg(min.) blocking 2x8(min.) -- — --___ deck joists DETAIL (Figure 32) — �\ DTT2Z ———--% Jcck juiat parallel m guardrail 2x8(mm.)rim joist bu••tm below ®Figure 30:Guardrail attachment OPTION 3 plan view Guardrail post Guardrail post Simpson DT-1-2Z (2)Simpson holdown or equal DTT2Z holdowrts r e l(one IR"diameter Decking 112^diameter sde ofh block'g) machine bolts \ \ machine bolts or th with O or threaded _ rod th nuts r..�^_' p and washrod with nuts washers rod Rimjoist----/ Dcckjoist I Blocking ) (2xg mm) (2x8 min) iDeck joist(2x8 min) 16"Min. Detail A Detail B Q Fig.31:Guardrail attachment OPTION 3 Fig.32:Guardrail attachment OPTION 3 perpendicular to guardrail parallel to guardrail 14'-1 5/8" Side view 3'-2 7/8" 3'-1 3/4" Solid Panel Solid Panel Solid Panel AIN c 7 1/2" 6'7/8" 6-3 7/8" 2x6 pt 3'-4 3/4" 3'-10 1/2" 1' " 1'-6" 1 1' DECK PROJECT FOR: 12/22/15 BOB WILLIAMS CONSTRUCTION CO. 21446 SW CMS CT BRUCE MCKINNEY TUALATIN OR 97062 13235 SW GENESIS LP TIGARD 97223 503-260-4634 CCB#207042