Loading...
Plans (211) ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. ANATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, DEC 72015 FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. CITY OP TIGARD CITV01FTIGAHI) GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE REVIEWED FOR CODE COMPLIANCE 'URDINGDIVISION GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. Approved: I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL OTC.- Imp TC:Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). ISc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Pcrmit#: j kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Address: lc { kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC Suite LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). �.� MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN By: Date: (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE OFFICE COPY PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 313 NEMA 3R, RAINTIGHTplyjI I�i� Iii . PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS THREE LINE IAGRAM LICENSE GENERAL NOTES PV6 ELECTRCAL CALCULATIONS OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC Cutsheets Attached AND 2012 IBC. RGC, CGC1 v_ 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON ELECTRICAL SPECIALTY CODE. MODULE GROUNDING METHOD: ZEP SOLAR BY DATE COMMENTS AHJ: Tigard REV A NAME DATE COMMENTS UTILITY: Portland General Electric CONFIDENTIAL A J B THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: -9723138 00 CONTAINED SHALL NOT BE USED FOR THE ESPINOZA, HUGO ESPINOZA RESIDENCE Jim McLean �, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 8660 SW GREENSWARD LN 4.16 KW PV ARRAY solarCity. PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES. TI G A R Dr OR 97224 3055 Cleorview Way IZ THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZ PAGE NAME: SHEET: REV DATE: Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1026 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-3.6-OUTD-S-US-Z-A (971) 227-7291 COVER SHEET PV 1 12/2/2015 (888)—SOL—CITY(765-2489)www.solorcity.com PITCH: 26 ARRAY PITCH:26 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories 8660 SW Greensward Ln (E) DRIVEWAY Front Of House Unlocked Gated LEGEND e ce AC O (E) UTILITY METER & WARNING LABEL m� INVERTER W/ INTEGRATED DC DISCO Inv & WARNING LABELS - - - —AC— — — Dc DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS u Q DC JUNCTION/COMBINER BOX & LABELS 8 DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER A STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR 4 CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L:J TOTAL ARRAY AREA (SF): 290 SITE PLAN NScale: 1/8" = 1' TOTAL ROOF AREA (SF): 1674 w E TOTAL ARRAY AREA IS a 17.33 0 1' 8' 161 Ed ' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-9 7 2 313 8 O O ESPINOZA, HUGO ESPINOZA RESIDENCE Jim McLean e o;;SOlar�■��y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8660 SW GREENSWARD LN 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH > THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZ PAGE NAME: SHEET: REV DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T.(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A (971) 227-7291 SITE PLAN PV 2 12/2/2015 (888)-SOL-CITY(765-2469)www.solarcity.com (E) 20 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT S1 ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C — — — 4„ _2„ 2„ 7K 6_4„ ZEP FLASHING C (3) (3) INSERT FLASHING. PRE—MANUFACTURED TRUSS (E) LBW (E) COMP. SHINGLE STRUCTURE MEETS THE II (1) If (4) PLACE MOUNT. SIDE VIEW OF MP1 NTS OF THE O SCRSEC ION 31111 (E) ROOF DECKING (2) `� A INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) G(5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES WITH SEALING WASHER (6) BOLT & WASHERS. LANDSCAPE 72" 24" STAGGERED (2-1/2" EMBED, MIN) PORTRAIT 48" 20" ROOF AZI lso PITCH 26 (E) RAFTER STAN DOFF TOP CHORD 2X4 @ 24" OCSTORIES: 2 ARRAY AZI 180 PITCH 26 BOT CHORD 2x4 @24" OC Comp Shingle Scale: 1 1/2 = 1 J B-9723138 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: \% CONTAINED SHALL NOT USED FOR THE ESPINOZA, HUGO ESPINOZA RESIDENCE Jim McLean .mss, Olar.�'�" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ''•„NOR r® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8660 SW GREENSWARD LN 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 gearview Way THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZSon M teo. CA 9"02 SOLARCITY EQUIPMENT, WITHOUT WRITTEN INVERTER: PAGE NAME: SHEET: REV DALE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.6—OUTD—S—US—Z—A (971) 227-7291 STRUCTURAL VIEWS PV 3 12/2/2015 (sea)—SOL—CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS 12.02.2015 Gt SystemStructural Version#53.4 D -Solar �vQ a i:Si Software Project Information&Table.Of Contents Risk Category: II PV System Type SolarCity SleekMount— Conip Roof Comp Roof Layers of'Comp Roofih 2 —~ Roof Slope 260 Rafter,5 acro 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 284 sf PV Module Width 39" PV Module'Length 66" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf ASCE Table 7 1 Surrounding Roof Snow 1000/0 25.0 Psf ASCE,Eq:7.4-1 Roof Snow Over PV Modules 10010vo 25.0 psf ASCE Eq: 7.4-1 Wind Desi n.Criteria Wind Design Code ASCE 7-05 Wind Design,Method 'Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure-Category C Section 6.5:6.3 Roof Style Gable Roof Fig.6-118/C/D-14A/B Mean Roof Height h 125 ft Sectio-n 6.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic,Factor Kit 1.00 Sectidn 65.7 Wind Directionality Factor Kid 0.85 Table 6-4 p Im ortance,Factor I 1A. Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/c/D-14A/6 Ext.Pressure Coefficient Down GC Down� 0.45 Fig.6-1181cfD-1dA/B Design Wind Pressure P p=gh GC Equation 6-22 Wind Pressure Up' p(up) -16:2 psf " Wind Pressure Down down 10.0 psf 0 Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Confiuration Landscape Staggered Max Standoff Tributary,Area' Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net;Wind Uplift ak Standoff T-actual 285 lbs Uplift Capacity of Standoff T_-allow500 lbs Standoff Demand/Capacity 'DCR 57.1% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA, Standoff Confi uration Portrait Staggered Max Standoff Tributary Area 'Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -320 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 63.9% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9723138 0 O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT USED FOR THE ESPINOZA, HUGO ESPINOZA RESIDENCE Jim McLean e�r ®�afC�t�/ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ''•1"J r® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8660 SW GREENSWARD LN 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleaNew Way THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZSan Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DAZE T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: 971 227-7291 PV 4 12/2/2015 (888)—SOL—CITY(765-2489) www.solorcity2 ABB PVI-3.6—OUTD—S—US—Z—A � ) UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: NoMatch Inv 1: DC Ungrounded INV 1 —(1)ABB # PVI-3.6-OUTD-S-US-Z-A LABEL: A —(16)REC # REC260PEZ OR # 180498 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:25 043586 Tie-In: Supply Side Connection FCI Inverter; Zigbee 3600W, 240V, 96% PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING CUTLER-HAMMER Inverter 1 IND Disconnect CUTLER-HAMMER 1 4 Disconnect 3 ABB DC- Vstart = 200V A 20A B PVI-3.6-OUTD-S-US-Z-A DG MP 1: 1x8 EGC 240V _—_____ ----- ---------_ A L1 r— B L2 DC+ I N DG I "IDC+ (E) LOADS GND __-- GND -------------------------- - EGG _-- DC+ Vstart —_ 200V GEC T N DG G MP 1: 1x8 EGCC-------------ouit Kit; 3/4' EMT I N I I I p I Z Z I C, I TO 120/240V SINGLE PHASE UTILITY SERVICE I I . I I I Voc* = MAX VOC AT MIN TEMP POI (2)ILSCO ,IPC 4/0-g6 A (1)CUTLER-HAMMER #DG222NRB /� D� Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Disconnect; 60A, 24OVac, Fusible, NEMA 3R A SC—ASSUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE B (1)CUTLER-HAMMER #DG221URB SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Disconnect; 30A, 240Voc, Non-Fusible, NEMA 3R —(1)CUTLER-HAMMER B DC03ONB Ground/Neutral Kit; 30A, General Duty(DG) _ ___..._..._-._ _. ___.__._..._.___....------------..__._ .__.- -----_-_.._ ____.____.......__..._.—___._._.___.._..._. ____......_.._.._._..-.._.__.__-----.-----__ — _.____ _ ..___.__.-_....__..___.. .__._ _.___ ._ _ ___...._._..__ �__...__ 1)AWG j6, THWN-2, Black g�(1)AWG#10. THWN-2, Block (2)AWG #10, PV Wire, 60OV, Black Voc* =333.43VDC Isc =9.01 ADC ® (1)AWG #6, THWN-2, Red O I�f-(1)AWG#10, THWN-2, Red O � (1)AWG #6, Stranded Bare Copper EGC Vmp =245.6 VDC Imp=8.5 ADC (1)AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC L�-LL(1)AWG#10, THWN-2. White NEUTRAL Vmp =240 VAC Imp=16 AAC (1 Conduit Kit; 3/1".EMT . . . . . . . . . . . . . . . . . . . . . .7.( AWG $6,,Solid Bare_Copper_ GEC. . . .-(1).Conduit.Kit;.3/4'_EMT. . . . . . . . . . . . . . . . .-(1)AWG#8,.THWN-2,.Green . . EGC/GEC.-(1)Conduit.Kit;.3/4".EMT. . . . , . . . . (2)AWG X10, PV wre, 600V, Black Voc* =333.43 VDC Isc =9.01 ADC rn (1)AWG #6, Stranded Bare Copper EGC Vmp =245.6 VDC Imp=8.5 ADC (1)Conduit.Kit; 3/4".EMT PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN d08 NUMBER: JB-9723138 00 HUGO ESPINOZA RESIDENCE Jim McLean w CONTAINED SHALL NOT E USED FOR THE ESPINOZA, �I1`C�I���'�` , NORBENFITSH OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM: 660 SW GREENSWARD LN 4.16 KW PV ARRAY WAS Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97224 3055 Clem-view Way ORGANIZATION, EXCEPT IN CONNEC110N WI1H THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 )63B-1029 PERMISSION OF SOLARCITY INC. INVERTER. 971 227-7291 PV 5 12 2 2015 (888)(SOLO)CITTY(765-2489)028 �www.solar ty.com ABB PVI-3.6—OUTD—S—US—Z—A � ) THREE LINE DIAGRAM / / ELECTRICAL CALCULATIONS Module: 16 REC 260PEZ 234.3 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Inverter 1: 1 ABB PVI-3.6-S AFCI 0.96 3840 3598.85 Vdrop= (Imp) * 2*Length)* Resistance / (Vmp) Module: REC 260PEZ 234.3 1 Imp A Max. Length ftWire Inverter 2: String: 8.5 60 AWG#10 at Max Ave Hi:87 deg F Module: REC 260PEZ 234.3 Vdrop= 8.5 120 0.00124 Ohms / 205.32 0.62 Innverter 3: Branch: 8.5 40 AWG#10 at Max Ave Hi:87 deg F Module: REC 260PEZ 234.3 Vdrop= (8.5 86 0.00124 Ohms) / 245.6 0.41 Iverter 4: Total voltage dropin DC conductors= 1.03 Inverter: 16 25 1 AWG#10 at 240V Vdrop= (16 50 0.00124 Ohms) 240 V 0.21 Total: 16 Modules Total Inv Pwr: 3840 13598.85 1 PTC CombinedF I at 240V Photovoltaic Module Electrical Specifications: Total STC:I 4160 Vdrop= Ohms) / 240 V Voc: 37.8 V deg F deg C Vmp: 30.7 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.21 Isc: 9.01 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 0 Imp: 8.5 A Record Hi Temp: Tvoc: -0.1 V/deg C Tisc:l 2.16 1 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 1 way wire length: N/A Voc Correction Factor: 1 strings per branch 1 1 strings per branch 2 ABB PVI-3.6-5 AFCI 9 P 9 Inverter Min Vdc Input: 139 8 modules per series strip 8 modules per series strip 8 REC 260PEZ p 9 P 9 Voc= 302.4 Min Vmp at Max Temp: 205.32 Voc= 302.4 V Voc= 302.4 V Max Voc at Min Temp:j 333.43 Vmp= 245.6 Inverter Max Vdc Input: 600 Vmp= 245.6 V Vmp= 245.6 V IsC= 9.01 IsC= 9.01 A IsC= 9.01 A Imp= 8.5 Max String Size: 14 Imp= 8.5 A Imp= 8.5 A lcont=l 11.26 Art 690.8(A)(1) 1-way wire length: 40 Icont=l 11.26 A lcont=l 11.26 A Art 690.8(A)(1) 1.a Conductor: AWG#10 PV Wire 2.a Conductor 1: N/A Conductor 2: N/A Icont*1.25=(Amps) 14.08 Conductor 1 Conductor 2 30 deg C ampacity= 401 Icont*1.25=(Amps) 14.08 14.08 1.b Icont=(Amps) 11.26 1 30 deg C ampacity= N/A N/A Start ampacity 40 2.b Icont=(Amps) 11.26 11.26 Temperature derate(%=F) 0.76 Start ampacity N/A N/A Conduit fill derate(%=#) 1 1 Temperature derate(%=F) N/A N/A Derated ampacity 30.4 Conduit fill derate(%=#) N/A N/A 1.0 Derated ampacity N/A N/A (cont*1.25=(Amps) 14.08 2.c Term 1 Term 2 Ampacity 40 Temp table N/A N/A (cont*1.25=(Amps) 14.08 14.08 1.d Icont*1.25=(Amps) 14.08 Ampacity N/A N/A OCP Size= 15 Inverter Type A Output 2.d OCP Size= 151 15 ABB PVI-3.6-S AFCI 1 way wire length: 25 ft Combined Inverter Output Icont= 16 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 20 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 25 OCP Size= 20 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 (cont=(Amps) Icont*1.25=(Amps) 20 4.a Icont*1.25=(Amps) 20 Art 690.8(B)(1) deg Campacity= 40 OCP size= 20 Art 240.6(A) 30 4.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 3.c 30 d =(Amps) 16 Start ampacity 40 Icont*1.25=(Amps) 20 Temperature derate(%=F) 0.91 30 deg C ampacity= 40 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 16 Derated ampacity 36.4 Start ampacity 40 3.d Icont*1.25=(Amps) 20 Temperature derate(%=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 36.4 4.d Icont*1.25=(Amps) 20 Ampacity 35 JB-9723138 0 o PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE ESPINOZA, HUGO ESPINOZA RESIDENCE Jim McLean ,solarCity. BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � 1 PNOR ARTSTO OTHERS ouTSIDEETHE REGPIENTSIN Comp Mount Type C 8660 SW GREENSWARD LN 4.16 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97224 3055 Clearvew Way THE SALE AND USE OF THE RESPECTIVE (16) REC # REC260PEZ PAGE NAME SHEET: REV: DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.6-OUTD-S-US-Z-A (971) 227-7291 ELECTRICAL CALCULATIONS PV 6 12/2/2015 (888)-SOL-CITY(765-2469)www.solarcity.com CAUTION: SOLAR CIRCUIT - Code:Label Location: Label Location: Label Location: - 0113 ._ •' WNl N G '• .•- I FC • ••04 NEC ••0 •4 'DO-NOT RELOCATE . . , • Location- THIS OVERCURRENT 1 PHOTOVOLTAIC DC DEVICE DISCONNECTPer Code: NEC 690.14.C.2 Label Location: Per Code: Label WARNING Location: ELECTRIC SHOCK HAZARD Label DO NOT TOUCH TERMINALS 690.17(4) WARNING D TE=RMINALS ON BOTH LINE AND _ • - POWER- OA MAXIMUM A LD SIDES MAY BE ENERGIZED ELECTRIC SHOCK HAZARD POINT CURRENT(Imp)- PerCode: IN THEPEN ION OPOSITTHE DC CONDUCTORS OF THIS NEC •• MAXIMUM POWER- PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN POINT VOLTAGE(Vmp)-vNEC 690.53 INVERTERIS UNGROUNDED AND MAXIMUM SYSTEM V MAY BE ENERGIZED UNGROUNDED• DD VOLTAGE(Voc)_ SHORT-CIRCUIT ALabel L• • CURRENT(Isc)_ PV SYSTEM DISCONNECT FOR UTILITY OPERATION Label • • WARNING Code:Per ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALSNEC •' Label • - • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC-.POINT OF -• LOAD SIDES MAY BE ENERGIZED INTERCONNECTION : Per Code: IN THE OPEN POSITION WARNING:'ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH 690.17.4; 690.54 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-.ENERGIZE BOTH SOURCE AND MAIN BREAKER. ... PV POWER SOURCE Label MAXIMUM AC Location: OPERATING CURRENT A WARNING Per Code: NEC OPERAT NGXVOLTAGE _ V ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED '• NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED _ Label • • CAUTION '• DUAL POWER SOURCE Per ••- SECOND SOURCE IS•- • • NEC 690.64.13.4 PHOTOVOLTAIG:SYSTEM PHOTOVOLTAIC AC (AC): AC Disconnect '• Conduit DISCONNECTPer Code: DistributionNEC 690.14.C.2 Label Location: (D): . . . CAUTLON (POI)_ Interior - Conduit PHOTOVOLTAIC SYSTEM nnect Per " (INV): Inverter With Integrated DC Disconnect CIRCUIT IS BACKFEDNEC 690.64.B.4 (M): Utility Meter '• Point of • • Way • 1 •• • / 1 / 1 1• 3055 Clearview San Mateo,CA 94402 Eli 1 1' • 1 • •1 1' 1• _ 11 1 1638-1029 1 • 1 1 , • • Com 1 1 • / 1 1 .Tz> ZS Comp Edge Zone Calculations 1 of 4ZS Comp Edge Zone Calculations 2 of 4 p S o La r 3/26/15 3/26/15 Zep S o La r This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30g27.64 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 GCN portrait= 0.4 0.9 Comp Mount Allowable Loads design load landscape= 15.35 27.64psf Load Duration Wind Snow :�ftoUplift= 656 lbs N/Adesign loadportrart12.28 27.64psf Lateral= 357 lbs 290 lbs '85$!8 r note:use 10 psf minimum Down Force= 1074 lbs 771 lbs Snow Calculations �, GREGOA! o To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. Attachment Spacing Calculations F�4r R6GFy Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 Uplift Spacing ExPir'ES: +2/31/10 degrees. Allowable Uplift Load FOR PAGES 1-4 Ground Snow Load= 30 psf uplift spacing = module length or width x design load Roof Pitch 14 30 Wind Uplift Calculations 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qh GCN (snow load spread over the length of the rafter) qh=0.00256 K,K,t Kd V2 I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Combinations: 14 30 Exposure= C Roof Zone= Edge Zone D+S= 31.16 25.10 psf Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf Gable/Hip Roof K,t= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.755 31.59 31.91 psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force Jscape effective area= 13.0 ftZ GCN portrait= -1.5 7711bs in -ortrait effective area= 21.7 ftZ landscape down force spacing = x 144 39"x 31.91psf f=89" tZ plandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 771lbs in portrait down force spacing = 65"x 31.91psf x 144 ftZ = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load;andscape= -27.73 psf design load portrait= -25.89 psf 6S6 lbs in landscape uplift spacing = 39"x 27.73 psf x 144 ftZ = 87" 656 lbs in portrait uplift spacing = x 144 65"x 25.89 psf f= 56" tZ Ir ZS Comp Edge Zone Calculations 3 of 4 Sa+1 ZS Comp Edge Zone Calculations 4 of 4 ^...J 3/26/15 3/26/15 ZepSolar ZepSolar Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 4S degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load lateral spacing - Maximum Uplift Pressure Landscape= -27.73 module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf ps=Cs Pf Roof Pitch= 31 4S degrees landscape module spacing = -1.4545 x 31.91 psf+ 120.7273 =74" pf=0.7 Ce Ct I pg Ce= 0.9 CS= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf Portrait module spacing = -0.8182 x 31.91 psf+79.909 = 54" I= 1.0 Ps= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 1 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30" 27° 30` Lateral Force Component 74" 48" 1 44" Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31t7.22 D+S= 13.50 14.49 8.65psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 290lbs in landscape lateral spacing= 39"x 14.49 psf x 144 ftz = 74" 290lbs in portrait lateral spacing = x 144 65"x 14.49 psf f 44" tz = Portrait spacing is less than 48".Try roof pitch of 27 degrees 290lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ftz =48" f '��,SolarQty ®pSotar Next-Level PV Mounting Technology 'i"SolarCity ®pSotar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs "I -roof Leveling M�— Leveling Foot Ground Zep Interlock Part No.850-1172 / - ETL listed to UL 467 �j Zep Compatible PV Nodule \ Zep Groove Roof Attachment p n,«yskirtComp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 QGpMP41i -_ B �F Description "OWN PV mounting solution for composition shingle roofs ~FA e� Works with all Zep Compatible Modules COMP°'' Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" uL LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Parl No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113.850-1421, zepsolar.com zepsolar.com Listed 60,L 156567 Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported. November 13,2015 2:23 PM Solar inverters Additional highlights: - ^.."" – RS-485 communication interface ABB string inverters (for connection to laptop or data logger). – Integrated Arc Fault Detection and AD { Interruption(-A Version). • f t\, <^fir Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ADD Mechanical specifications 3300 Nominal output power 3000W 360OW 380OW 420OW Maximum output power wattage 3000 3300' 3300' 3600 4000' 4000' 3 0 4200' 4200' 4200 4600' 4600' W W W W W W W W W W _ W .. W .. Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V � Input side(DC) Number of independent MPPT channels 2 2 2 2 wo, Maximum usable power for each channel 2000W - 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj 12035.OV) Full power MPPT voltage range 160-530V 120-530V 140-530V _140-536V Operating MPPT voltage range 0.7 x Vstart-580V(>=90V) � V Maximum current(ldcmax)for both MPPT in 20A 32A 32A 32A „ parallel ..........1i .........i; Maximum usable current per channel 1 OA 16A 16A 16A Maximum short circuit current limiter channel p 12.5A 20.OA 20 OA 20.OA Number of wire landing terminals per channel 2 pairs ,axra+� Array wiring termination Terminal block,pressure clamp,AWG IO-AWG4 a Output side(AC) -t Grid connection type 10/ Split- 10/ 10/ Split- 10/ to/ = Split- i 10/ 10/ Split- 10/ " ............cti .,,,....,, 2W 0/3W: ..2W 2W � 0/3W 2W -...2W.. .O/3W' 2W 2W .0/3W 2W Adjustable voltage range(Vmin-Vmax)(V) 183- 211 - 244- 183- 211- 244- 183- i 211- - 244- 183- 211- 244- ._ -!N""'"" - ,,,,,,,,, ............. 228V 264V 304V 228V 264V 304V, 228V 264V 304V 228V 264V 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(I—).) 14.5 14.5 ` 12.0 17.2 16.0 160 16.0 16.0 160 20.0 20.0 20.0 ...... ..... .. 1............... . :.. 'qurns Auus .Aunts A­ ..Au t......Ae_, Aui.,s. A..,, A„s,......!�r+r S Aunts A`.s Power factor >0.995 ..... ............ .............. ........ .................. ............ ..... ...... .... .... .. .. ............... Total harmonic distortion at rated power _ <2% This Tamil of single-phase strsn The high-speed MPPT offers real- Highlights: Grid cairn termination type Terminal block,Pressure clam AWG10-AWG4 Y9g vp p. inverters complements the typical time power tracking and improved – Single phase and split phase output Input protection devices number of rooftop solar panels energy^larvesting. grid connection. Reverse polarity protection Yes Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high – Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices Anti-islandin protection Meets UL 1741/IEEE1547 requirements of the property. a consistent and stable performance – The high speed and precise MPPT 9 Over-voltage protection type Vanstor,2(L,-L�/L,-G) across the entire input voltage and algorithm offers real time power Maximum AC OC PD Rating 20A 20A 15A 25A 20A 20A 20A 20Ap 20A 25A 25A 25A This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two stringsThe transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. – Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8w Communication installations with two different installations with reduced string size. – Integrated DC disconnect switch User-inRemote monitorinterface 1s characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international 9(1xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range -13°F to+140°F with derating above 122°F(50°C) example:East and West unit able to withstand the harshest p ) Ambient air storage temperature range to+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission leve] <50 db(A)®tm . Maximum operating altitutde without derating 6560 ft(2000 m) optima energy harvesting condition. AL up t Capability enabled at nominal AC voltage and with sufficient DC power available - Pourer and productivity for abetter world" 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD