Plans Iis7,101,5 5 OFFICE COPS l0 3? s- RE, UAW REMODEL Of EXISTING HOME DEC 21 2015 DESIGN CRITERIA CITU of RGARb BUILDING CODE- 20ll RESIDENTIJAL SPECIALTY CODE BUILDING DIV1,�I�A L SOILS-1500L8 PS+F FLOOR LOAD-40PSF LIVE 15LB PSF DEAD LOAD Prescriptive wall bracing Engineered lateral design Retaining walls > �'or surcharged WIND LOAD-100M44 The following "Genera! Notes and Supplemental Irformafion" are now part of your approved plans SEISMIC-Dl It is the responsibility of the builder to comply with these requirements during construction. STRUCTURAL OBSERVATION Where there is a conflict between a general note and 'the plans; the more restrictive shall apply SITE ALL MEASUREMENTS TO BE FIELD VERIFIED R302.1 Property lines shall be clearly identified by finding the existing official corner markers or providing a property CONCRETE survey for inspection of the setbacks and fire separation distance between the lot lines and new constr'.'iction. FOOTINGS, GRAVITY WALLS AND SLASS-3000 PSI P1101.5.3.2 Drywells must be located at least 5 from a properl:y line and 10' from a building unless approved through a MAX A6GREGAiE 3/4- Plumbing Appeal. This distance, dr -)(well. measured to the center of the dwell LOCATE AND INSTALL CONTOL AND EXPANSION JOINTS AS NOTED R324 Untreated wood shake or shingle roofing is not allowed on buildings located in a Wildfire Hazard zone. REINFORCING FOUNDATION/UNDER-FLOOR/ATTIC ALL REBAR TO BE SCHEDULE 60 R109.1.1 Reinforcing steel and connectors to be embedded in concrete shall be in place and supported at time of foundation inspection. #4 BAR NOTED ON PLANS FOR RELNF019yT UNLESS OTHERWISE STATED R317.1 All wood shall be pressure-preservative-treated or of natural resistance to decay where there is less than 13' ALL SPLICES TO BE STAGGERED ALL BARS SHALL BE MIN 3' FROM ALL OUTER EDGES OF CONCRETE clearance to ground under floor joists or 12- under girders, ire: direct contact with concrete, or exposed are d supporting porches and decks. CONNECTORS R502.6 Provide 3 of bearing at beam pockets and 112' air space at sides and endue ALL CONCRETE 'J" BOLTS S14d4l L BE 112' X 10' MIN 7" EMBED WITH 3X3 X1/4' R401.3 Lots shall be graded to drain surface water away-from exterior walls a minimum of 6"vertical in 10- horizontal. WASHER AND NUT UNLESS OTHERWISE NOTED R403.1.5.1 Bottoms of foundation footings shall extend least 18 below finish grade: except foundations of freestanding TE ALL CONNECTIONS FROM OLD CONCRETE TO NEW CONCREDOWELED WITH MIN 8" accessory structures of light frame construction not more than 600 SF with an eave height not more than 10 #4 DRILLED 4" EACH WAY WHERE POSSIBLE feet; and decks not supported by a dwelling may extend not less than 12' below grade R403.1.1 Member of floors U./all Thickness Foottna UL"r 8404.1.1 1 dth Footrna Thickness �- i 12= s' R404.1.5 1 2 3 i 10- I 18' R403.1.4 When the footing and stem wall are placed in separate concrete pour. one;;4 vertical bar shall be placed 48'o.c. with each bar having a 6" hook in the footing and extending at least 14' into the stem wall R403.1.4.1 Foundation stem walls shall be provided with a minimum of one#4 bar within; 12 inches of the top of the wall and one#4 bar a minimum of 3' clear from the bottom of the footing. "Jlorolithic foundations shall be permitted to have a minimum of tw::#4 bars placed in the footing R403.1.7 A grounding electrode system shatl be installed in foundations: one#4 horizontal bar not less than 3'fror-i the WOOD FRAME bottom of the footing and not less thar 20' long. one#4 vertical bar stubbed up at least 12' above the floor ALL WOOD TO BE DOUGLAS FIRA-AR04 #2 UNLESS OTHERWISE NOTED plate with a minimum 12- splice to the horizontal bar. ALL WOOD TOUCHING CONCRETE TO 8E PRESSURE TREATED R403.1.8 Foundation anchor bolts shall be not fess than 1;'2" diameter bolts embedded at least T' into concrete or ALL WOOD TO BE 19% MOISTURE OR LESS R602.11.1 masonry. spaced 5-0" on center maximum. with at least two bolts per plate and within: 12" of ends anc' �mers. 1;4'X 3' X 3"washer are required at all anchor bolts the full length of all required braced wall iines _ ALL BLOCKING TO BE FULL HEIGHT AS MEMEBER BEING BLOCKED 8404.1.6 Foundation wall shall extend at least 6 above grade. ALL SPLICES TO 8E A MINMUM OF 4' OVERLAP 8405.1 Drains ,Hall be provided around ;;![ foundations enclosing habitable or usable space below rad' ALL NAILING TO USE APPROPRIATE COMMON NAILS FOR SECURE FASTENING R405.1 Waterproofing is required on the outside surface of below rade foundation walls enclosing interior space GALVANIZED OR STAINLESS INTO PRESSURE TREATED WOOD R407.3 Columns shall be anchored at the bottom except columns less Char: 48' in height within underfloor areas ALL SIMPSON CONNECTORS TO USE RECOMMENDED FASTENERS AS PER MANUFACTURER enclosed by a continuous foundation. ALL SHEATHING TO BE APA RATED AS PER DRAWING NOTES AND NAILED ACCORDING TO R408.1 Provide foundation vents at a rate of 1 SF vent area per 150 SF of craw! area w,;&.in 3'of each corner and or SUPPLIED SCEDULE at least 3 sides. ALL SHEATHING TO BE BLOCKED AT ALL EDGES R408.3 An 18"x 24"access opening is required tc all under-floor space 1XCESS NCT--HING WILL RESULT IN REMOVAL AND REPLACING Of MEMBER OVER-NGT_' iED R501.3 The underside of floor assemblies shall have 1.12gypsum wallboard or 5;8' *ood structural panel except oder a craw! space not used for storage or fuel-fired equipment or when supported by 2X 10 or greater floor joists c CA 3 d r I 0 I N � O -� OCA M o , ' m w D M vi M m M j oo n 19 '-10" j -m Y < M x (IE) DECK 12X6 TREATM�1 1) D CKING ON I ii II � � IIII I --� X t CA i0 LT 7 I�TSI 1�' O m I I I H 34'-9" M I I i I j r i i w m Im N W m CJ- I I I Nn xz I CA I I M I -+ f11 I O m I rn n q 24' 4" I � � n , I I I 12'-4" I CA l � m A o , D I 27CA A '-2"A o in j O PROP LINE EU 'C3 W C', o1, — (D 000 � 2O W -4 cr T o i -o —� ,. HARRIS MOHAMMAD ZIKA DESIGN LLC 'Y7an zllka oo/oo/oo d t REMODEL OF EXISTING HOME 2421 SE ASH ST Gu+ Drawn By � Revlabn f w TIGARD OR 97223 PORTLAND OR 97214 �,,kodesign@gmaii.com 503 380 4556 Chackad By 10375 SW ML90NALD 5 R"..,ly Review ..Reviewed By Drawing Coda Z — Drawing Title Line 1 Consultant Name „ F«M—, "' O I Drawing Title Line 2 Consultant Address 1 Submitted By a 1 4 Drawin Title Line 3 Consultant Address 2 «' """ g Sam Traut � 00/00/00 No. Data Issue Notu El I JE_ DECK :u ............ ....... ® GRADE GRADE EAST ELEVATION SOUTH ELEVATION SCALE 3/16"1'0" AA � a L6��1 A q GRADE x ' t 1E3 GRADE LT I GRADE LJ z& NORTH ELEVATION WEST ELEVATION SCALE 3/16"1'0" i 1 2 3 SHEARWALL SCHEDULE HOLDOWN SCHEDULE SIMPSON LSTA30 STRAP TO BEAM BELOW -_ ATTACH TO DBL STUDS @SHEARWALL A NOMINAL 1/2" WOOS SRUCTURAL PANELS W/8dCOMMON NAILS - 6"OC AT EDGES 12"OC FIELD - --- -- - - - - -- E -DECK -2-X-6-- TREATED -DECK-ING -ON AA 2x6--PT--3OIST_5 --2-_4" OC - - A - _01 - - - -- - -- : - --.-_ - - BATH --- - - - 2 KITCHEN -- --_- — _ --- 1- -- —72 _— DINING00 1 -- - 18'-3" _---_-- _--_--_- _- - - „RISE 7.5 ., --Z - - BEDROOM RUN 9" '^ BATH -V -- - - VAULTED o DN 30 ! s t 4X 16 RIDGELll N —_I''1- - -- -- - -- -- -- - - HALL t d J I } 00 =---•o-aH - = N J m =„ V W O B --- rl -- - - W x 3 a"tea - - - -- LIVING ' 0 BEDROOM " �sn j° BEDROOMVAULTED ENTRY � )Z a10'-8" E i e� O w O o z f O 03 SOF 10'-7" 29= W • _ $Mt Scali i MAIN FLOOR PLAN i - 1 N - j 1 } } DECK ABOVE 6'-0" mommooll 1 1 7'-2 I 4'0 X3'6 I o SLIDER ENTRY -/ 3'-0" �> 1 1 r ll ' I I BATH 1 1 HWRUN 9" 00 II CONT HNDRl. mDo BEDROOM IPNCE 1 1 I I o t DECK ABOVE I HALL Fli ffs 1 1 I ( STUDY a N 1 1 2'9X1'10 FP SILL@5'0 x LIVING o I I t 1 E 1 1 II 2'9X2'10 SILL@2'0I [0.. ?�2'9X1'10 I 10" 9-4 SILL@5 0 _ £x0 w C N LLO 1 1 STUD WALL AT CONCRETE: 1/2" AIR SPACE FIRE BLOCKING: CONT AT TOP 10OC VERTICAL R15 BATT INSU 1. �fuwul (E)ROOF VENTS EA BAY TYP 4X16" RIDGE BEAM (2) 4X8 DFL 1/2' PLY ROOF SHEATHING TYP: CUT PLATES AMD INSTALL (2)FULL 15LB FELT HEIGHT STUDS 4X4 DFL#2 CONTINUOUS COLUMN COMP ROOF CONNECT TOP PLATE AND BOTTOM PLATE ON SOLID BLOCKING �_ _� .�N, 2X8 DFL RAFTERS 24 OC W/ SIMPSON A34 1/2" GYP TYP (VAULTED CEILING) PROVIDE SIMPSON LSTA 12 STRAP AT FRONT AND MAINTAIN V AIR SPACE MINIMUM 2'0 OVERLAP BACK OF PLATE SPLICE AT ALL PLATE JOINTS (E) R-21 BATT INSULATION TYP I WALL SHEATHING 1/2" APA RATED PANELS (E)SCREENED VENTS SIMPSON A34 SIMPSON A34 TYP AILED 8D COMMON 6" EDGE 12" FIELD TYP FASTEN PLATES TO STUDS E) 2X4 DFL DBL PLATES (3) 10d NAILS EA SIDE TYP f � �.r�L.5TA12 A34 4X6 HEADER DFL#2 4X6 HEADER DFL#2 4X6 HEADER DFL#2 3'-3" (N)3'O X4'8" (N)3'O X4'8" (N)3'O X4'8" (N)4'0 X4'8" 3'-5" SNG HNG SNG HNG SNG HNG SNG HNG U 35 U 35 U 35 (N) 3-0 X6'8 U 35 n Il ISULATED DOOR N U40 �r a 2X4 STUD WALL i. 16' OC TYP FULL HEIGHT s $ 2x4 STUDS TYP 1 3a ! :g IL -j L n o J h P A �3 I N d i g SIMPSON H2.5 @EACH JOIST TYP a " ' PROVIDE SS 3/8"X3-1/2" ° " S g LAGS@ BRACKETS N 8 a = INTO BEAM SIMPSON LSTA12 STRAP@BEAM SPLICE TYP L SOLID 2X10 BLOCKING TYP 8'-4 1/4" NAIL W/(10) 10d _ S (2) PER BRACKET TYP 8'-4 1/2" t N 8'-2 1/2" W S � 3.5" STEEL PIPE COLUMN TYP 2X10 DFL JOISTS c Q 0 16 OC TYP .0% 9 « A 2 d AA BUILDING CROSS SECTION f LOOKING WEST SCALE 1/2"=1'0" • 4X4 TREATED POST 4'OC TYP 2X2 TREATED PICKET 4" MAX OPENING BTWN _ Z O 1 2X6 TREATED CONT RAIL USE #10X 3" TREATED SCREWS in 2X4 TREATED CONT RAIL USE #10X 3" TREATED SCREWS 4„ 2X2 TREATED PICKET 4" MAX OPENING BTWN 4X4 TREATED POST 4'OC TYP o 0 0 r' r ADD 2X12 TREATED RIM JOIST IMPSON DTTZZ W/ (8)1/4"X1-1/2"SDS SCREWS PER MFR 4'OC 4'-0" HOT DIP 1/2" X 8" THRU BOLT (E) 2X6 TREATED DECKING 4' OC TYP (E) 2X10 PT JOISTS 16"OC TYP HOT DIP 1/2" X 6" �/ C THRU BOLT (E) 4X10 BEAM W/ STEEL PIPE COLUMNS 9-OC 4' OC TYP DECK RAIL ELEVATION SCALE 1/2"=1'0" 2X2 TREATED PICKET 4" MAX OPENING BTWN 4X4 TREATED POST 4'OC TYP a 1 o e 0 1 H N, n A s i HOT DIP 1/2" X 6" a THRU BOLT ^ 4' OC TYP N Q O W NN` 3 GRADE - i D DECK RAIL SIDE CONDITION =m SCALE 1/2"=1'0" a OXO Ito Q K J w OC W xp~ : W B � OC DECK RAIL DETAIL E $11Mf 5 v SCALE 1/2"=1'0" 1 2 3 E)ROOF SHEATHING R E 2x8 DFL RAFTERS 24"OC (E) ROOF SHEATHING (E)2 X4 TOP PLATE SIMPSON A35 TYP EDGE NAIL WALeSATHING @ PLATE f" r' CUT PLATES AND PROVIDE r FULL HEIGHT STUDS SIMPSON LSTA12 @ PLATE SPLICE SIMPSON 4DE ' SIMPSON LSTA12 STRAP SIMPSON LSTA12 @ PLATE SPLICE !R AT BOTH FACES A p"' CON l.?S 5 DBL STUDS /HEADER AS OCCCURS r 14 WALL SHEATH16.4NOMINAL WOOD L3 PANELS NAILED "OC @EDGES 12" FIljjj 2 Ilk SIMPSON A34 @EA SIDE SIMPSON LSTOaOO..SE;FLUSH TO BOTTOMyO��M W/(22) I&NAI S SIMPSON TAH TRAP— FLUSH WITH (E)2X4 BOTTOM PLATE _ OF BEAM(E) 2X10 JOIST ATT /(22) lOd # a EDGE NAIL WALL SHEATHING @ PLATE x N (E) FLOOR SHEATHING (E) 2X10 DOKST (EBO PLATE J m = ae MPSON A34 (E) ItOOR SHEATHING AT EA SIDE 8 r/ (E) 2X1 FL JOISTS PROVI4EROIS BLOCKING SIMPSON N�' BETS TYP H2.5 AT t = SIMPSON A34 @ EA JOIST TYP _ EA JOIST " (E) 4X10 DFL BEAM X.F � 1 01 (E) 440 DFL BEAM � o= f N P W eZi � p •• N0.0 Q=X z Ow FRAMING DETAIL AT WESA FRAMING DETAIL AT WEST WALL " 5...5••. SCALE 3/4"=1'0" SCALE 3/4"=1'0"