Plans (3) -0003,j--
8'
o 38'PVC SAN SEWER`,_;
7,777 T
RECEIVED 7'
if
JUN o 2 2015 S 89°58'00"E 133.11' - - - I II.
LII'r (-)F TIGARD I Y4'WATER METER II '/e'WATER METER
PARCEL 1 I II_ I PARCEL 2
PLANNING/ENGINEERING
II o
Iw
o I I II, I
o, I II I
I II
II
I I • tl
II. i
I II.
I II I
of 133.15' _ I:
PARCEL! --- 1 , AC
LVING SPACE 3,000 SO FT TIL E rOT
GARAGE/SHOP 960 SO FT NEW 12'WIDE II.
TOTAL FLOOR AREA 3,960 SO FT 4 q AIC SH RED
1 DRIV WAYII'
�, �'.
ROOF 2,983 SOFT 16 If I
PAVEMENT 2,719 SOFT 46'-64'
TOTAL IMPERVIOUS 5,702S(3
,702 SO FT o
TOTAL LOT AREA 13,048 SO FT PARCEL 1
wl
I NEW 1"PVC
40'-0* - WATER SERVICE
3016 L PLAN
w/4-CA GARAGE I. g
w
I' z
LOT 14
43'-g-
-- )i 89°58'00'W 133.18' -
NEW 4"PVC SAN
SEWER LATERAL I✓
LOT 26 i �I I NEW 1-PVC
I WATER SERVICE
PARCEL2
I
W PARCEL 2 -
I� I�
NEW 4"PVC SAN
c SEWER LATERAL
N PARCEL2
LOT 13
TO 8"PVC SAN Fq FH<
LOT 27 SEWER IN SW
I KABLE ST.
- - - - N 89°58'00"W 133.21'
LOT 6 / LOT 7
SITE PLAN - PARCEL 1 O�
Scale 1"=40'
SAGE BUILT HOMES SATTLER PARTION PARCEL 1
R G E B 1 I L 18820 NW Bethany Court#200 Job No. 156-0911-10 Date 6/01/15 Sheet
t1 �J Beaverton,Oregon
pfy1�' Client Sage Built Homes By MEB
Oregon Residential Energy Code January 2012 • No. 1
State of Oregon Additional Measures
Building Codes Division:
Required Options
Better Buildings for Oregon
TABLE N1101.1(2)
ADDITIONAL MEASURES
High efficiency walls&windows:
Extenor walls—U-0.047/R-19+5(insulation sheathing)/SIPS,and
Windows—Max 15%of conditioned area;or
Windows-U-0.30
High efficiency envelope:
Exterior walls—U-0.058/R-21 Intermediate framing,and
Vaulted ceilings—U-0.033/R-30A d,`,and
2 Flat ceilings—U-0.025/R49,and
Framed floors—U-0.025/R-38,and
Windows—U-0.30;and
oDoors-All doors U-0.20,or
Q Additional 15 percent of permanently installed lighting fixtures as high-efficacy lamps or Conservation Measure D and E
w
u
Y
Y High efficiency ceiling,windows&duct sealing:(Cannot be used with Conservation Measure E)
3 Vaulted ceilings—U-0.033/R-30A d•`,and
Flat ceilings—U-0,025/R49,and
Windows-U-0.30 Windows-U-0.30,and Performance tested duct systems b
a
High efficiency thermal envelope UA:
v
4
Proposed UA is 15%lower than the Code UA when calculated in Table N1104,1(1)
W
L
Building tightness testing,ventilation&duct sealing:(Cannot be used with Conservation Measure E)
0
W
5 A mechanical exhaust,supply,or combination system providing whole-building ventilation rates specified in Table 1101.1(3),or
ASHRAE 62.2,and
The dwelling shall be tested with a blower door and found to exhibit no more than:
1. 6.0 air changes per hour a and Performance tested duct systems n
Ducted HVAC systems within conditioned space:(Cannot be used with Conservation Measure B or C)
s All ducts and air handler are contained within building envelope'
Building Codes Division♦ Department of Consumer and Business Services♦State of Oregon
1535 Edgewater St.NW,Salem,OR 97304 ♦ P.O.Box 14470,Salem,OR 97309-0404
503-378-4133 ♦ Fax: 503-378-2322 ♦bcd.oregon.gov \ .
Additional Measures Required Options
Page 2 of 3
High efficiency HVAC system:
Cas-fired furnace or boiler with minimum AFUE of 90%a,or Air-source heat pump with minimum HSPF of 8.5 or
Closed-loop ground source heat pump with minimum COP of 3.0
Ducted HVAC systems within conditioned space:
B All ducts and air handler are contained within building envelope'
Ductless heat pump:
cReplace electric resistance heating in at least the primary zone of dwelling with at least one ductless mini-split heat pump having
a minimum HSPF of 8.5.Unit shall not have integrated backup resistance heat,and the unit(or units,if more than one is installed
C in the dwelling)shall be sized to have capacity to meet the entire dwelling design heat loss rate at outdoor design temperature
.21 condition. Conventional electric resistance heating may be provided for any secondary zones in the dwelling. A packaged
' terminal heat pump(PTI IP)with comparable efficiency ratings may be used when no supplemental zonal heaters are installed
in the building and integrated backup resistant heat is allowed in a PTHP.
�i
High efficiency water heating&lighting:
o. D Natural gas/propane,on-demand water heating with min EF of 0.80,and
A minimum 75 percent of permanently installed lighting fixtures as CFL or linear fluorescent or a min efficacy of 40 lumens per watt
as specified in Section N 1107.2`
d
o' Energy management device&duct sealing:
E Whole building energy management device that is capable of monitoring or controlling energy consumption,and
Performance tested duct systems b,and
A minimum 75 percent of permanently installed lighting fixtures as high-efficacy lamps.
Solar photovoltaic:
F Minimum l watt/sq ft conditioned floor space s
Solar water heating:
G Minimum of 40 ft of gross collector area h
For SI:I square foot=0.093 m:,I watt per square foot=10.8 W/m:.
a Furnaces located within the building envelope shall have sealed combustion air installed.Combustion air shall be ducted directly from the outdoors
b. Documentation of Performance Tested Ductwork shall be submitted to the building official upon completion of work.This work shall be performed by a contractor
certified by the Oregon Department of Energy's(ODOE)Residential Energy Tax Credit program and documentation shall be provided that work demonstrates
conformance to ODOE duo performance standards.
c. Section NI 107.2 requires 50 percent of permanently installed lighting fixtures to contain high efficacy lamps.Each of these additional measures adds an additional
percent to the Section N 1107.2 requirement,
d. A=advanced Game construction,which shall provide full required ceiling insulation value to the outside of exterior walls,
e• The maximum vaulted ceiling surface area shall not be greater than 50 percent of the total heated space floor area unless vaulted area has a U-factor no greater than U-
0,026.
f Building tightness test shall he conducted with a blower door depressurizing the dwelling 50 Pascal's from ambient conditions M umentatian of blower door test Shall
be submitted to the Building Official upon completion of work
g. Solar electric system size shall include documentation indicating that Total Solar Resource Fraction is not less than 75 percent
h. Solar water heating panels shall be Solar Rating and Certification Corporation(SRCC)Standard OG-300 certified and labeled,with documentation indicating that Total
Solar Resource Fraction is not less than 75 percent.
i. A total of 5 percent of an HVAC systems ductwork shall be permitted to be located outside of the conditioned space.Ducts located outside the conditioned space shall
have insulation installed as required in this code
CITY OF TIGARD
Approved by Planning-
--------- - ~ �1t�S!1TtEBZRE�T�-
Date
3/10) ) s ' ---
Initials: Yin b - S 89.58'00'E 133.11' I I'
}t
I WATER METER }I- j1 �•WgTER METER
PARCEL2 I It.'_tl PARCEL2
IL' 11.
RECEIVE[
MAR 10 2015
111. .tt
CITY OF TIGARD
BUILDING DIVISIO14
Itl.' h.l
S89.58'00-E 133.15' .�. F.
PARCEL! — — — — �— t •f}'
LVING SPACE 3,016 SO FT I R E rOT I
GARAGE/SHOP 500 SO FT § JI't.}I.
TOTAL FLOOR AREA 3,610 SO FT H NEW 17 WI EAC
55-11• SHARED DRI AY }I h
ROOF 2,881 SO FT 15
NEW4'PvcSANI
PAVEMENT 2.201 SO FT
TOTAL IMPERVIOUS 5,082 SO FT
TOTAL LOT AREA 13,048 SO FT EL 1 PAR ,`{ 'I
wl 47'-2t�' 3f - I
6 - NEW 1'PV WATER
.I. I' SERVICE F
301 L PLAN I.1_::_}
NI
wl 4-CP R GARAGE
T..F s
F.:...}.
4 •I. l; r f. I LOT 14 i
--- - t.
N 8958'00'W 133.18'
J J
LOT 26 I / SNEWWATER
ERVICE PARCEL 2
I
NEW 4-PVC SAN
SEWER LATERAL
PARCEL2
PARCEL2 II
/ /JI
I / /
LOT 13
/ / I
Is•
-o•�TI<
LOT 27
N 89-5900'W 133.21'
LOT 6 T LOT 7
SITE PLAN•PARCEL 1
saeI.,w. N
SAGE BUILT HOMES SATTLER PARTION PARCEL 1
SAG E BU 1 L 18820 NW Bethany Court#200 Job No. 156-0911-10 Date 2/26/15 Sheet
Beaverton,Oregon
Ubu.: