Report (2) 4-1 ��\\ ls�ls vsw �CA�(7' ASNBoi'seCascade Single 9-1/2" BCI® 5000-1.7 DF Main LeveftFloorJoistsW6(i955) %VDry 12 spans I No cantilevers 10/12 slope June 17, 2015 10:55:54 BC CALC®Design Report 16OCS Repetitive Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\Floor Joists\Main LeveNFloor Joists\J6(i955) Address: Lot 1 Specifier: PDG City,State,Zip: , Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: 09-06-14B 1 09-06-1411-08-14 62 BO Total Horizontal Product Length=21-03-12 Reaction Summary (Down I Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live BO,4-3/8" 237/49 47/0 B1,3-1/2" 688/0 172/0 B2,4-3/8' 281 /21 65/0 Live Dead Snow Wind Roof Live OCs Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 0 FC1 Floor Material Unf. Lin. (Ib/ft) L 00-00-00 21-03-12 53 13 n/a Disclosure Controls Summary Value %Allowable Duration Case Location Completeness and accuracy of input must Pos. Moment 799 ft-lbs 32.5% 100% 3 16-01-01 be verified by anyone who would rely on Neg. Moment -869 ft-lbs 35.3% 100% 1 09-06-14 output as eudence of suitability for End Reaction 347 lbs 30.8% 100% 3 21-03-12 particular application. Output here based on Int.Reaction 860 lbs 41% 100% 1 09-06-14 building code-accepted design properties and analysis methods. Installation of End Shear 322 lbs 21.8% 100% 3 20-11-06 Cont.Shear 448 lbs 30.3% 100% 1 09-08-10 BOISE engineered wood products must be in accordance with current Installation Uplift -2 lbs n/a 100% 3 00-00-00 Guide and applicable building codes.To Total Load Defl. L/999 (0.101") n/a n/a 3 15-07-10 obtain Installation Guide or ask questions, Live Load Defl. L/999 (0.084") n/a n/a 6 15-07-10 please call(800)232-0788 before Total Neg. Defl. L/999 (-0.016") n/a n/a 3 06-02-03 installation. Max Defl. 0.101" n/a n/a 3 15-07-10 BC CALC®, BC FRAMER®,AJSTm, Span/Depth 14.4 n/a n/a 0 00-00-00 ALLJOISTO, BC RIM BOARDTm, BCI®, BOISE GLULAMTM, SIMPLE FRAMING %Allow %Allow SYSTEM®,VERSA-LAM®,VERSA-RIM Bearing Supports Dim. (L x W) Value Support Member Material PLUS®,VERSA-RIM®, BO Wall/Plate 4-3/8"x 2" 284 lbs 7.6% 25.3% Unspecified VERSA-STRAND®,VERSA-STUD®are B1 Wall/Plate 3-1/2"x 2" 860 lbs 28.9% 41% Unspecified trademarks of Boise Cascade Wood B2 Wall/Plate 4-3/8"x 2" 347 lbs 9.3% 30.8% Unspecified Products L.L.C. Notes Design meets User specified (L/360)Total load deflection criteria. Gesign meets User specified (L/480) Live load deflection criteria. Design,meets arbitrary(1")Maximum total load deflection criteria. Calculations assume Member is Fully Braced. Composite El value based on 3/4"thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Page 1 of 1 taN Boi§e Cascade Single 9-1/2" BCI® 5000-1.7 DF Main Level\Floor Joists\J7(i919) ������{{yy77y/// Dry 12 spans I No cantilevers 10/12 slope June 17,2015 10:55:54 BC CALC®Design Report 16 OCS Repetitive I Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\Floor JoistsWlain Level\Floor JoistsU7(i919) Address: Lot 1 Specifier: PDG City,State, Zip: , Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: 17 .t a � T .l, T ,1, ! T I ! 1 T I X T .1 T T7 .� 1 BO 09-06-14 131 11-01-10 B2 Total Horizontal Product Length=20-08-08 Reaction Summary (Down/ Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B0,4-3/8" 244/46 49/0 B1,3-1/2" 776/0 202/0 B2, 1-5/8' 269/23 62/0 Live Dead Snow Wind Roof Live OCS Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 0 FC1 Floor Material Unf. Lin. (Ib/ft) L 00-00-00 20-08-08 55 14 n/a 1 5(i120) Conc. Pt. (Ibs) L 09-06-14 09-06-14 81 28 n/a Disclosure Controls Summary Value %Allowable Duration Case Location Completeness and accuracy of input must Pos. Moment 772 ft-lbs 31.4% 100% 3 15-10-07 be verified by anyone who would rely on Neg. Moment -855 ft-lbs 34.7% 100% 1 09-06-14 output as evidence of suitability for End Reaction 331 lbs 34.5% 100% 3 20-08-08 particular application. Output here based on Int.Reaction 977lbs 46.5% 100% 1 09-06-14 building code-accepted design properties End Shear 322 lbs 21.8% 100% 3 20-06-14 and analysis methods. Installation of BOISE engineered wood products must be Cont.Shear 448 lbs 30.3% 100% 1 09-08-10 in accordance with current Installation Total Load Defl. L/999 (0.093") n/a n/a 3 15-05-04 Guide and applicable building codes. To Live Load Defl. L/999 (0.077") n/a n/a 6 15-05-04 obtain Installation Guide or ask questions, Total Neg. Defl. L/999 (-0.015") n/a n/a 3 06-03-09 please call(800)232-0788 before Max Defl. 0.093" n/a n/a 3 15-05-04 installation. Span/Depth 14 n/a n/a 0 00-00-00 BC CALC®, BC FRAMER®,AJSTm, ALLJOISTV, BC RIM BOARDTm, BCI®, %Allow %All low BOISE GLULAM-, SIMPLE FRAMING Bearing Supports Dim. (L x W) Value Support Member Material SYSTEM®,VERSA-LAM®,VERSA-RIM BO Wall/Plate 4-3/8"x 2" 294 lbs 7.9% 26.1% Unspecified PLUS®,VERSA-RIM®, B1 Wall/Plate 3-1/2"x 2" 977 lbs 32.9% 46.5% Unspecified VERSA-STRAND®,VERSA-STUD®are B2 Wall/Plate 1-5/8"x 2" 331 lbs 24.3% 34.5% Unspecified trademarks of Boise Cascade Wood Products L.L.C. Notes Design meets User specified (U360)Total load deflection criteria. Design meets User specified (U480)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume Member is Fully Braced. Composite EI value based on 3/4"thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Page 1 of 1 [T2,Boi`seCascade Single 9-1/2" BCI® 5000-1.7 DF Main Levef\Floor Joists\J5(i939) Dry 12 spans I No cantilevers 10/12 slope June 17, 2015 10:55:54 BC CALC®Design Report 16 OCS I Repetitive Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\Floor JoistsWlain Level\Floor JoistsU5(i939) Address: Lot 1 Specifier: PDG City,State, Zip: , Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: BO 14-01-00 B1 14-07-14 62 Total Horizontal Product Length=28-08-14 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO, 1-3/4" 333/48 71 /0 B1,3-1/2 939/0 235/0 B2,4-3/8 352/44 77/0 Live Dead Snow Wind Roof Live OCS Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 0 FC1 Floor Material Unf. Lin. (Ib/ft) L 00-00-04 28-08-14 53 13 n/a Disclosure Controls Summary Value %Allowable Duration Case Location Completeness and accuracy of input must Pos. Moment 1,254 ft-lbs 51% 100% 3 22-03-06 be verified by anyone who would rely on Neg. Moment -1,623 ft-lbs 66% 100% 1 14-01-00 output as evidence of suitability for End Reaction 404 lbs 41.6% 100% 2 00-00-00 particular application. Output here based on Int.Reaction 1,174 lbs 55.9% 100% 1 14-01-00 building code-accepted design properties End Shear 405 lbs 27.4% 100% 3 28-04-08 and analysis methods. Installation of Cont.Shear 582 lbs 39.4% 100% 1 14-02-12 BOISE engineered wood products must be in accordance with current Installation Total Load Defl. L/741 (0.232") 48.6% n/a 3 21-08-05 Guide and applicable building codes. To Live Load Defl. L/865 (0.199") 55.5% n/a 6 21-07-03 obtain Installation Guide or ask questions, Total Neg. Defl. L/999 (-0.047") n/a n/a 3 09-06-04 please call(800)232-0788 before Max Defl. 0.232" 23.2% n/a 3 21-08-05 installation. Span/Depth 18.1 n/a n/a 0 00-00-00 BC CALC®, BC FRAMER® ,AJSTM, ALLJOIST®, BC RIM BOARD rm, BCI®, %Allow %Allow BOISE GLULAMT"', SIMPLE FRAMING Bearing Supports Dim. (L x W) Value Support Member Material SYSTEM®,VERSA-LAM®,VERSA-RIM BO Wall/Plate 1-3/4"x 2" 404 lbs 27.2% 41.6% Unspecified PLUS®,VERSA-RIM®, B1 Wall/Plate 3-1/2"x 2" 1,174 lbs 39.5% 55.9% Unspecified VERSA-STRAND®,VERSA-STUD®are B2 WaIVP late 4-3/8"x 2" 429 lbs 11.5% 38.1% Unspecified trademarks of Boise Cascade Wood Products L.L.C. Notes Design meets User specified (L/360)Total load deflection criteria. Design meets User specified (L/480)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume Member is Fully Braced. Composite EI value based on 3/4"thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Page 1 of 1 ASN IBotseCascade Single 9-1/2" BCI® 5000-1.7 DF Main Levef\Floor Joists\J3(i933) V mm- Dry 12 spans I No cantilevers 10/12 slope June 17, 2015 10:55:55 BC CALCO Design Report 16 OCS Repetitive I Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\Floor Joists\Main Level\Floor Joists\J3(i933) Address: Lot 1 Specifier: PDG City,State,Zip: , Designer: Customer: PROB UILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: 3 �, .l .����,� ,� 0,�,l. �'L .i, L-1 .L I -. L._ '.L—.. BO 131 14-05-06 16-01-14 62 Total Horizontal Product Length= 30-07-04 Reaction Summary (Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO, 1-7/8" 431 /60 105/0 B1,3-1/2" 1,003/0 251 /0 B2,4-3/8" 380/40 85/0 Live Dead Snow Wind Roof Live OCs Load Summary Tag Description Load Type Ref. Start End 100% 90%, 115% 160% 125% 0 FC1 Floor Material Unf. Lin. (Ib/ft) L -00-00-00 30-07-04 27 7 n/a 1 FC1 Floor Material Unf. Lin. (Ib/ft) L -00-00-00 29-02-06 27 7 n/a 2 FC1 Floor Material Unf. Lin. (Ib/ft) L 29-02-06 30-07-04 23 6 n/a 3 10(i 126) Conc. Pt. (Ibs) L 00-00-04 00-00-04 87 34 n/a Controls Summary Value %Allowable Duration case Location Pos. Moment 1,525 ft-lbs 62% 100% 3 23-07-01 Neg. Moment -1,861 ft-lbs 75.7% 100% 1 14-05-06 End Reaction 536 lbs 54.4% 100% 2 00-00-00 Int.Reaction 1,254 lbs 59.7% 100% 1 14-05-06 End Shear 443 lbs 30% 100% 3 30-02-14 Cont.Shear 636 lbs 43.1% 100% 1 14-07-02 Total Load Dell. L/566 (0.336") 63.6% n/a 3 22-11-05 Live Load Dell. L/667 (0.285") 71.9% n/a 6 22-08-11 Total Neg. Dell. L/999 (-0.071") n/a n/a 3 09-04-11 Max Dell. 0.336" 33.6% n/a 3 22-11-05 Span/Depth 20 n/a n/a 0 00-00-00 %AI low %AI low Bearing Supports Dim. (L x W) Value Support Member Material BO Wall/Plate 1-7/8"x 2" 536 lbs 33.1% 54.4% Unspecified B1 Wall/Plate 3-1/2"x 2" 1,254 lbs 42.1% 59.7% Unspecified 52 Wall/Plate 4-3/8"x 2" 466 lbs 12.5% 41.4% Unspecified Notes Page 1 of 2 Boise Cascade Single 9-1/2" BCI® 5000-1.7 DF Main Levef\FloorJoistsW3(OX moo— Dry 12 spans I No cantilevers 10/12 slope June 17, 2015 10:55:,, TIC CALC®Design Report 16 OCS I Repetitive I Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\Floor Joists\Main LeveWloor Joistsll3(i93 Address: Lot 1 Specifier: PDG City,State, Zip: , Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: Design meets User specified (L/360)Total load deflection criteria. Disclosure Design meets User specified (L/480)Live load deflection criteria. Completeness and accuracy of input mus Design meets arbitrary(1")Ma)amum total load deflection criteria. be verified by anyone who would rely on Calculations assume Member is Fully Braced. output as evidence of suitability for Composite EI value based on 3/4"thick OSB sheathing glued and nailed to member. particular application. Output here based c building code-accepted design properties Design based On Dry Service Condition. and analysis methods. Installation of Deflections less than 1/8"were ignored in the results. BOISE engineered wood products must bi in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions; please call(800)232-0788 before installation. BC CALC®, BC FRAMER®,AJSTM, ALLJOISTO, BC RIM BOARD rm, BCI®, BOISE GLULAMTM' SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRANDS,VERSA-STUDS are trademarks of Boise Cascade Wood Products L.L.C. taNSoi§e Cascade Single 9-1/2" BCI05000-1.7 DF Main LeveftFloor,loists\J4(071) kv. Dry 12 spans I No cantilevers 10/12 slope June 17,2015 10:55:55 BC CALC®Design Report 16 OCS Repetitive Glued &nailed construction Build 3924 File Name: 15-968.mmdl Job Name: Westwood Homes Description:Designs\FloorJoists\Main Level\FloorJoists\,J4(i971) Address: Lot 1 Specifier: PDG City,State,Zip: , Designer: Customer: PROBUILD FOREST GROVE Company: BOISE CASCADE BMD Code reports: ESR-1336 Misc: 14-07-14 14-07-14 BO 61 B2 Total Horizontal Product Length=29-03-12 Reaction Summary (Down/ Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live BO,4-3/8" 353/46 77/0 B1,3-1/2" 951 /0 238/0 B2,4-3/8" 353/46 77/0 Live Dead Snow Wind Roof Live OCs Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 0 FC1 Floor Material Unf. Lin. (Ib/ft) L 00-00-00 29-03-12 53 13 n/a Disclosure Controls Summary Value %Allowable Duration Case Location Completeness and accuracy of input must Pos. Moment 1,254 ft-lbs 51% 100% 2 06-05-08 be verified by anyone who would rely on Neg. Moment -1,664 ft-lbs 67.7% 100% 1 14-07-14 output as evidence of suitability for End Reaction 429 lbs 38.1% 100% 2 00-00-00 particular application. Output here based on Int.Reaction 1,189 lbs 56.6% 100% 1 14-07-14 building code-accepted design properties End Shear 405 lbs 27.4% 100% 2 00-04-06 and analysis methods. Installation of BOISE engineered wood products must be Cont.Shear 585 lbs 39.6% 100% 1 14-06-02 in accordance with current Installation Total Load Defl. L1741 (0.232") 48.6% n/a 2 07-00-09 Guide and applicable building codes. To Live Load Defl. L/862 (0.2") 55.7% n/a 6 22-02-01 obtain Installation Guide or ask questions, Total Neg. Defl. L/999 (-0.047") n/a n/a 2 19-03-14 please call(800)232-0788 before Max Defl. 0.232" 23.2% n/a 2 07-00-09 installation. Span/Depth 18.1 n/a n/a 0 00-00-00 BC CALC®, BC FRAMER®,AJSTm, ALLJOIST®, BC RIM BOARDTm, BCI®, %Allow %Allow BOISE GLULAMTM, SIMPLE FRAMING Bearing Supports Dim. (L x W) Value Support Member Material SYSTEM®,VERSA-LAM®,VERSA-RIM BO Wall/Plate 4-3/8"x 2" 429 lbs 11.5% 38.1% Unspecified PLUS®,VERSA-RIMS, B1 Wall/Plate 3-1/2"x 2" 1,189 lbs 40% 56.6% Unspecified VERSA-STRANDS,VERSA-STUDS are B2 Wall/Plate 4-3/8"x 2" 429 lbs 11.5% 38.1% Unspecified trademarks of Boise Cascade Wood Products L.L.C. Notes Design meets User specified (U360)Total load deflection criteria. Design meets User specified (L/480)Live load deflection criteria. Design meets arbitrary(1")Maximum total load deflection criteria. Calculations assume Member is Fully Braced. Composite EI value based on 3/4"thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Page 1 of 1