Report (2) TIMBERLAND HOMES ,"U sT).0/L-f— UUUL 11-20-14 rR S U R TROY PARK 2 FLOOR BEAM 1 ` Z v s � �/^ i/� �w 8:56ar 0 1 S Beam4.605 nBeamEngine 4.6.1.0 laterials Database 1472 Member Data Description: FLOOR BEAM 1 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous DEC 15 2014 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building CodeePff UF Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total ��°Ri�� Dead Load: 10 PLF Deck Connection: Nailed Member WERKWNGLIDIVNION Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Back 0' 0.00" 13' 6.00" 260 65 Live Additional Uniform(PLF) Front 0' 0.00" 13' 6.00" 180 45 Live 13 6 0 i 13 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 3895# - 2 13' 6.000" Wall N/A N/A 1.500" 38954 - Maximum Load Case Reactions Jsed forapplying point loads(or line loads)to carrying members Live Dead 1 3002# 8921E i 3002# 892# Design spans 13' 7.750" Product: 1.5 RigidLam LVL 3-1/2 x 11-7/8 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 1/2"diameter bolts at 24.0"oc Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading 'ositive Moment 13286.'# 30888.'# 43% 6.75' Total Load D+L Shear 3330.# 121924 27% -0.06' Total Load D+L rL Deflection 0.3039" 0.6823" U538 6.75' Total Load D+L -L Deflection 0.2343" 0.4549" U698 6.75' Total Load L :ontrol: LL Deflection DOLS: Live=100% Snow=115%n Roof=125% Wind=160% All product namesare trademarksof theirrespective owners TROY FOWLER FOWLER HOME DESIGN LLC. Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. 0 'rising is def ned as when the member,floorjoist,beam or girde4 shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans Iisled on this sheet.The aon must be reviewed by a nualified desionerordesion omfetnional as mouired for aoomval.Thisdesion as roes omdur-t installation arconlino to the manufacturer—ecifications �- TIMBERLAND HOMES 11-20-14 yr R O , S E B U R G TROY PARK 2 FLOOR BEAM2 8 5101`1 Ir S Bearn4.605 nBearnEngine 4.6.1.0 laterials Database 1472 Member Data Description:FLOOR BEAM 2 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 10.4 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Back 0' 0.00" 12' 6.00" 260 65 Live Additional Uniform(PLF) Front 0' 0.00" 6' 0.00" 350 87 Live O 12 6 0 it 12 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 2.056" 4137# -- 2 12 6.000" Wall N/A N/A 1.500" 2758# -- Maximum Load Case Reactions Jsod for applying point loads(or line loads)to carrying members Live Dead 1 3259# 878# 2 2154# 604# Design spans 12' 7.750" Product: 1.5 RigidLam LVL 1-3/4 x 11-7/8 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0"oc Minimum 2.06"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11046.'# 15444.'# 71% 4.99' Total Load D+L Shear 3373.# 6096.# 55% -0.06' Total Load D+L TL Deflection 0.4248" 0.6323" 0357 6.01' Total Load D+L LL Deflection 0.3334" 0.4215" U455 6.01' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% All product names are trademarksof their respective owners TROY FOWLER FOWLER HOME DESIGN LLC. Copyright(C)2013 by Simpson Strong-Te Company Inc.ALL RIGHTS RESERVED. 'assing is defined as when the member,floorjoist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The son mud he reviewed by a oualified desionerordason mefessi—I as reouired for anemval This deson amimes omdurt installation accodino to the manufacturer s:necifications TIMBERLAND HOMES 11-20-14 TROY PARK 1 FLOOR BEAM 3 8:40am 'R O ' S E B U R U'' tofl S Beam4.605 nri Engine 4.6.1.0 7aterials Database 1472 Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 10.4 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Back 0' 0.00" 9' 6.00" 100 25 Live Additional Uniform(PLF) Front 0' 0.00" 9' 6.00" 240 60 Live 9 6 0 CD Q i 9 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2100# 2 9' 6.000" Wall N/A N/A 1.500" 2100# - Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 1640# 460# 2 1640# 460# Design spans 9' 7.750" Product: 1.5 RigidLam LVL 3-1/2 x 11-7/8 1 ply PASSES DESIGN CHECKS Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading PositiveMoment 5064.'# 15444.'# 32% 4.75' Total Load D+L Shear 1669.# 6096.# 27% 8.61' Total Load D+L TL Deflection 0.1158" 0.4823" U999+ 4.75' Total Load D+L LL Deflection 0.0904" 0.3215" U999+ 4.75' Total Load L Control: Positive Moment DOLS: Live=100% Snow=115% Roof=125% Wind=160% u All product names am trademarks of their respective owners TROY FOWLER FOWLER HOME DESIGN LLC. ^ t' Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. 0 Passing is defined as when the member,floorjoisL beam or girder shown on this drevnng meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The inn mun hp revipwpd by a nualified desinnarnrdasinn nmfpssfnnal as mnuimd for anomval.Thisdesion aseimes nmduct installation accanfino to the manufacturers specifications TIMBERLAND HOMES 11-20-14 /1"R 0 S E B U R G TROY PARK 2 FLOOR BEAM 4 9:090f 1 le 'S Beafn4.605 mBeatn[ngne 4.6.1.0 laterials Database 1472 Member Data Description:FLOOR BEAM 4 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 20.8 PLF ` Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Back 0' 0.00" 12' 6.00" 180 45 Live Additional Uniform(PLF) Front 0' 0.00" 12' 6.00" 350 87 Live Additional Uniform(PLF) Top 0' 0.00" 12' 6.00" 80 20 Live 12 6 0 12 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0'. 0.000" Wall N/A N/A 1.500" 4950# -- 2 12' 6.000" Wall N/A N/A 1.500" 4950# - Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 3857# 1093# 2 3857# 1093# Design spans 12' 7.750" Product: 1.5 RigidLam LVL 3-1/2 x 11-7/8 2 ply PASSES DESM CHECKS Connect members with 2 rows of 1/2"diameter bolts at 24.0"oc Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 15648.'# 30888.'# 50% 6.25' Total Load D+L Shear 4175.# 12192.# 34% 11.94' Total Load D+L TL Deflection 0.3074" 0.6323" U493 6.25' Total Load D+L LL Deflection 0.2395" 0.4215" U633 6.25' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% u All product names amtrddemarksoftheir respective owners TROY FOWLER FOWLER HOME DESIGN LLC. Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. 0 'rising isdef ned as when the member,goorjoist,beam or ,girder,shown on This drawing meets applicable desgn criteria for Loads,Loading Conditions,and Spans listed on this sheet.The .vnn mica tin mviewad by a nnalif ed deinnar nr devnn nmfecannal as mmiimrl fnr annmval Thisda-inn acaim—md—.1 in#allalinn ar.r r-finn In the manofactr,mrc.marifr.atinns TIMBERLAND HOMES 11-20-14 O S E B U R G T-inOY PARK 2 FLOOR BEAM 5 9. I8of 1 CS Beam4.605 IorrBeantEngine 4.6.1.0 Materials Database 1472 Member Data Description:FLOOR BEAM 5 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 5.2 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Top 0' 0.00" T10.00" 40 20 Live Additional Uniform(PLF) Back 0' 0.00" 7'10.00" 230 57 Live T 710 0 O 710 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1405# -- 2 7.'10.000" Wall N/A N/A 1.500" 1405# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 1077# 328# 2 1077# 328# Design spans 7'11.750" Product: 1.5 RigidLam LVL 1-3/4 x 11-7/8 1 ply PASSES DESIGN (CHECKS Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive'Moment 2803.'# 7722.'# 36% 3.92' Total Load D+L Shear 1057.# 3048.# 34% -0.06' Total Load D+L TL Deflection 0.0877" 0.3990" L/999+ 3.92' Total Load D+L LL Deflection 0.0672" 0.2660" L/999+ 3.92' Total Load L Control: Positive Moment DOLS: Live=100% Snow=115% Roof=125% Wind=160% e All product names amtrademarksoftheir respective ovmers TROY FOWLER Copyright(C)2073 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. FOWLER HOME DESIGN LLC. Passing is defined as when the member,floor joist,beam or girdet shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The TIMBERLAND HOMES 11-20-14 TROY PARK 2 FLOOR BEAM 6 R O' S E B` R G 101`1 :S Beam4.605 mBeamEngne 4.6.1.0 4aterialsDatabase 1472 Member Data Description:FLOOR BEAM 6 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 10.4 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Point(LBS) Top 6' 4.00" 1405 0 Live O 1710 0 1710 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1447# -- 2 17'10.000" Wall N/A N/A 1.500" 1044# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 1264# 183# 2 860# 183# Design spans 17'11.750" Product: 1.5 RigidLam LVL 1-3/4 x 11-7/8 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0"oc Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8033.'# 15444.'# 52% 6.33' Total Load D+L Shear 1388.# 6096.# 22% -0.06' Total Load D+L TL Deflection 0.5504" 0.8990" U392 8.02' Total Load D+L LL Deflection 0.4857" 0.5993" U444 8.02' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% All product namesare trademarksof theumspective owners TROY FOWLER FOWLER HOME DESIGN LLC. r r' Copynght(C)2073 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. m Bassi ng is tlefined as when the member,floorjoist,beam or giber,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The 6—r .ho mvinwad TIMBERLAND HOMES 11-20-14 0 S E B L) R G TROY PARK 2 FLOOR BEAM 7 1rr 9:20am I of 1 CS Beam4.605 IanBeamEn&e 4.6.1.0 Materials Database 1472 Member Data Description:FLOOR BEAM 7 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 21.0 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Back 0' 0.00" 20' 0.00" 250 62 Live Additional Uniform(PLF) Front 0' 0.00" 20' 0.00" 210 52 Live O 2000 2000 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.522" 5993# - 2 20' 0.000" Wall N/A N/A 1.522" 5993# -- Maximum Load Case Reactions Used fol-applying point loads(or line loads)to canying members Live Dead 1 4634# 1360# 2 4634# 1360# Design spans 20' 1.750" Product: 2.0 RigidLam LVL 5-1/4 x 16 1 ply PASSES DESIGN CHECKS Minimum 1.52"bearing required at bearing#1 Minimum 1.52"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive-Moment 30185.'# 52221.'# 57% 10' Total Load D+L Shear 5200.# 159604 32% -0.06' Total Load D+L TL Deflection 0.6153" 1.0073" U392 10' Total Load D+L LL Deflection 0.4757" 0.6715" U508 10' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% T.T. All product names aretrademadcsoftheir iespectiveowners TROY FOWLER FOWLER HOME DESIGN LLC. Copyright(C)2013 by Simpson Stmng-Tie Company Inc.ALL RIGHTS RESERVED o Sassing is defined aswhen the member,ffoorloist,beam orguder,shown on thisdmwing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on thissheel.The Sinn mutt he reviewed by a eualified desioner or desion omf—onal as moulred for anomval This desion assumes omduct installatinn accordion to the manufachirers mar.ificatinns �'' TIMBERLAND HOMES 11-20-14 // R S E B U R G TROY PARK 2 FLOOR BEAM 8 9:11 as of 1 :S Beam4.605 mBeannEngne 4.6.1.0 1aterials Database 1472 Member Data Description:FLOOR BEAM 8 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 20.8 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Top 0' 0.00" 16' 8.00" 80 20 Live Additional Uniform(PLF) Front 0' 0.00" 16' 8.00" 40 10 Live Additional Uniform(PLF) Back 0' 0.00" 16' 8.00" 200 50 Live A 71 16 8 0 0 16 8 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 a 0.000" Wall N/A N/A 1.500" 3537# -- 2 16' 8.000" Wall N/A N/A 1.500" 3537# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 2690# 847# 2 2690# 847# Design spans 16' 9.750" Product: 1.5 RigidLam LVL 3-1/2 x 11-7/8 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 1/2"diameter bolts at 24.0"oc Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 14868.'# 30888.'# 48% 8.33' Total Load D+L Shear 3121.# 12192.# 25% -0.06' Total Load D+L TL Deflection 0.5163" 0.8406" 0390 8.33' Total Load D+L LL Deflection 0.3926" 0.5604" 0513 8.33' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% All product names are trademarks of their respective owners TROY FOWLER Copyright(C)2013 by Simpson Strong-Te Company Inc.ALL RIGHTS RESERVED. FOWLER HOME DESIGN LLC. _ o 'assing is defined as when the member,floorjoist,beam or girder shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The .ion—.1 be reviewed by a oualified desioner or desinn nmfp-cional as reouimd for anoroval.This desinn a—mes nmduct installation acconfino to the manufacturers snecifications TIMBERLAND HOMES 11-20-14 arn R S E 13 U G TROY PARK 2 FLOOR BEAM 9 8.51 0f] CS Beam4.605 IanBeamEngine 4.6.1.0 Materials Database 1472 Member Data Description:FLOOR BEAM 9 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 5.2 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Front 0' 0.00" 8' 4.00" 225 56 Live Additional Uniform(PLF) Back 0' 0.00" 8' 4.00" 180 45 Live 8 4 0 8 4 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 2.154" 2167# -- 2 8' 4.000" Wall N/A N/A 2.154" 2167# -- Maximum Load Case Reactions Used forapplying point loads(or line loads)to carrying members Live Dead 1 1717# 450# 2 1717# 450# Design spans 8' 5.750" Product: 1.5 RigidLam LVL 1-3/4 x 11-7/8 1 ply PASSES DESIGN CHECKS Minimum 2.15"bearing required at bearing#1 Minimum 2.15"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive'Moment 4594.'# 7722.'# 59% 4.17' Total Load D+L Shear 1661.# 3048.# 54% -0.06' Total Load D+L TL Deflection 0.1623" 0.4240" U626 4.17' Total Load D+L LL Deflection 0.1286" 0.2826" U791 4.17' Total Load L Control: Positive Moment DOLS: Live=100% Snow=115% Roof=125% Wind=160% ®e Allpmductnamesaretmdemadcsoftheir respective owners TROY FOWLER Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. FOWLER HOME DESIGN LLC. 'ass ng is defined as when the member,fioorjoisL beam or giber,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The cion must be reviewed by a oualified d—onar or deson omfessional as renuired for annmvnl.This desion amimes omduct insfallatinn ar.—Minn to tha —M—i— TIMBERLAND HOMES 11-20-14 a S E B U R G TROY d'%J.K 2 FLOOR BEAM 10 9:01arI of 1 �S Beam4.605 anBeatnEngne 4.6.1.0 vlaterials Database 1472 Member Data Description: FLOOR BEAM 10 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 10.4 PLF Filename: TROY PARK 2 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PLF) Front 0' 0.00" 12' 6.00" 40 10 Live Additional Uniform(PLF) Back 0' 0.00" 12' 6.00" 350 87 Live IT 12 6 0 12 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.563" 3145# -- 2 12-' 6.000" Wall N/A N/A 1.563" 3145# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 2466# 679# 2 2466# 679# Design spans 12' 7.750" Product: 1.5 RigidLam LVL 3-1/2 x 11-7/8 1 ply PASSES DESIGN CHECKS Minimum 1.56"bearing required at bearing#1 Minimum 1.56"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive'Moment 9943.'# 15444.'# 64% 6.25' Total Load D+L Shear 2653.# 6096.# 43% 11.94' Total Load D+L TL Deflection 0.3907" 0.6323" U388 6.25' Total Load D+L LL Deflection 0.3063" 0.4215" 0495 6.25' Total Load L Control: LL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160% All product names am trademarks of their respective owners TROY FOWLER Copyright(C)2013 by Simpson Sfmng-Tie Company Inc.ALL RIGHTS RESERVED. FOWLER HOME DESIGN LLC. a lassi ng is defined as when the member,floor joist,beam or glyde4 shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The son must he reviewed by a oualified desioner or desion omfessional as mouired for aoomval This dasinn nss-As nmdnnr indallarinn accnnfinn to tha mam darhimre m>ifi—fi oc