Loading...
InspectionsLocation: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14920 SW 83RD AVE, TIGARD, OR, 97224 Residential - Mechanical 610 Gas line FAIL MEC2015-00732 David Young No pressure in gas line for test. PRESSURE TEST not holding. Systems utilizing less than 14 inch water column shall hold min. 10 psi for 15 minutes with no perceptible drop in pressure. Systems utilizing welded piping and systems in excess of 14 inch water column shall hold min. 60 psi for 30 mins. G2417.4.1C406.4.1Identify gas pipe at meter bank as to address served. C401.7v Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14920 SW 83RD AVE, TIGARD, OR, 97224 Residential - Mechanical 699 Mechanical final FAIL MEC2015-00732 David Young No pressure in gas line for inspection. See gas line inspection report. Violation Summary: Inspector Contractor