ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS NO. I 1 4 DATE: December 16, 2015 PROJECT TITLE: Inform Accounting 15895 SW 72ND AVE PROJECT NUMBER: 150214.01 SUITE 200 BY: Kelly Sanford PORTLAND,OR 97224 PHONE:503.226.1285 FAX:503.226.1670 The following instructions, clarifications, or revisions are to be incorporated into the drawings IN CIDAINC.COM WWW.CIDAINC.COM and specifications. Only items noted are revised, all other items are to remain unchanged. WW Drawing Revisions: • SKI: Revised wall type "C", corridor wall type, to be wall type "A". o Per OSSC Section 1018, Corridors,Table 1018.1 Corridor Fire-Resistance � �� Rating: An occupancy B building with more than 30 occupant load served and a sprinkler system is not required to have fire-rating at corridors. See attached p. 274 for Table 1018.1. DEC 21 2015 o Inform Accounting is located in a 3 story sprinklered occupancy B building therefor the corridors require no fire-rating. CffYOFTIGARD oWall Type C, 1-HR Fire Wall, not used. All type "C"wall become type „A„ BUILDING DIVISION o Door 200-A no longer required to be part of a 1-HR assembly (20 min door). End ASI No. I ��0Poo (5-Co-�50-7 City of Tigard od v Flans my Date ZA 6 REVISION ARCHITECTURE OFFICE ENGINEERING `"` ��� -1, COPY' P L A N N I N G I N T E R I O R S L A N D S C A P E Badcadd\15\0214.01 Inform Accounting\Current\Sketches\ASI I—Addenda revisions.docx MEANS OF EGRESS the exit access which contain seats, tables, furnishings, dis- 4. Afire-resistance rating is not required for corridors plays and similar fixtures or equipment. The required width in an occupancy in Group B which is a space requir- of aisles shall be unobstructed. ing only a single means of egress complying with Exception: Encroachments complying with Section Section 1015.1. 1005.7. 5. Corridors adjacent to the exterior walls of buildings 1017.2 Aisles in assembly spaces. Aisles and aisle access- shall be permitted to have unprotected openings on ways serving a room or space used for assembly purposes unrated exterior walls where unrated walls are per- shall comply with Section 1028. mitted by Table 602 and unprotected openings are 1017.3 Aisles in Groups B and M.In Group B and M occu- permitted by Table 705.8. pancies, the minimum clear aisle width shall be determined TABLE 1018.1 by Section 1005.1 for the occupant load served,but shall not CORRIDOR FIRE-RESISTANCE RATING be less than 36 inches(914 mm). REQUIRED FIRE-RESISTANCE OCCUPANT RATING(hours) Exception: Nonpublic aisles serving less than 50 people OCCUPANCY LOAD SERVED and not required to be accessible by Chapter 11 need not BY CORRIDOR sprinkklWith sprinkler leerr ssyystem system` exceed 28 inches(71 1 mm)in width. H-1,H-2,H-3 All Not Permitted 1 1017.4 Aisle accessways in Group M. An aisle accessway H-4,H-5 Greater than 30 Not Permitted 1 shall be provided on at least one side of each element within the merchandise pad. The minimum clear width for an aisle A,B.E,F,M,S,U Greater than 30 1 0 accessway not required to be accessible shall be 30 inches R Greater than 10 Not Permitted 0.5 (762 mm). The required clear width of the aisle accessway shall be measured perpendicular to the elements and mer- I-2',I 4 All Not Permitted 0 chandise within the merchandise pad.The 30-inch(762 mm) 1-1,1-3 All Not Permitted 1' minimum clear width shall be maintained to provide a path to adjacent aisle or aisle accessway. The cornrnon path o a. For requirements for occupancies in Group 1-2, see Sections 407.2 and an ad J �• p f 407.3. egress travel shall not exceed 30 feet (9144 mm) from any b. For a reduction in the fire-resistance rating for occupancies in Group 1-3, point in the merchandise pad. see Section 408.8. Exception: For areas serving not more than 50 occupants, c. Buildings equipped throughout with an automatic sprinkler system in the common path of egress travel shall not exceed 75 feet accordance with Section 903.3.1.1 or 903.3.1.2 where allowed. * (22 860 mm). ' 1018.2 Width.The minimum width of corridors specified in 1017.5(22 Aisles in other than assembly spaces and Groups B and M.In other than rooms or spaces used for assembly pur- poses and Group B and M occupancies, the minimum clear TABLE 1018.2 aisle width shall be determined by Section 1005.1 for the MINIMUM CORRIDOR WIDTH occupant load served, but shall not be less than 36 inches OCCUPANCY WIDTH(minimum) (914 mm). Any facilities not listed below 44 inches Access to and utilization of mechanical, 24 inches SECTION 1018 plumbing or electrical systems or equipment CORRIDORS With a required occupancy capacity less 36 inches 1018.1 Construction.Corridors shall be fire-resistance rated than 50 in accordance with Table 1018.1.The corridor walls required Within a dwelling unit 36 inches to be fire-resistance rated shall comply with Section 708 for in Group E with a corridor having a required fire partitions. capacity of 100 or more 72 inches Exceptions: In corridors and areas serving gurney traffic . A fire-resistance rating is not required for corridors in occupancies where patients receive out- 72 inches in an occupancy in Group E where each room that is patient medical care,which causes the used for instruction has at least one door opening patient to be incapable of self-preservation directly to the exterior and rooms for assembly pur- Group 1-2 in areas where required for bed 96 inches poses have at least one-half of the required means of movement egress doors opening directly to the exterior. Exte- For St: I inch=25.4 mm. rior doors specified in this exception are required to be at ground level. 1018.3 Obstruction.The required width of corridors shall be unobstructed. 2. A fire-resistance rating is not required for corridors contained within a dwelling or sleeping unit in an Exception: Encroachments complying with Section occupancy in Group I-1 and Group R. 1005.7. 3. A fire-resistance rating is not required for corridors 1018.4 Dead ends. Where more than one exit or exit access in open parking garages. doorway is required, the exit access shall be arranged such 274 2014 OREGON STRUCTURAL SPECIALTY CODE DOOR SCHEDULE DOOR # DOOR HARDWARE OPENING WIDTH DOOR DOOR DOOR FRAMENOTES DOOR # TYPE GROUP x HEIGHT THICKNESS MATERIAL FINISH MATERIAL 200—A A 2 3'-0"x7'-0" 1 3/4" SC WD STAINED HMK 1 200—A y HARDWARE SCHEDULE 1I.EXISTING DOOR TO BE RELOCATED IF FEASIBLE. TYPE 2 SEE DEMO PLAN 1/A1.1. PROVIDE NEW DOOR PER SCHEDULE AS NECESSARY. 1 1/2 PAIR BUTTS 2. NOT USED. 1 EA. ENTRANCE LOCKSET 1 EA. CLOSER ABBREVIATIONS: (E) EXISTING 1 SET SILENCERS SC WD SOLID CORE WOOD DOOR 1 EA. WALL STOP HMK HOLLOW METAL KNOCK DOWN o A FOF o s i [! I • `'4 j B I 1 EAK 1 ROOM I . - 1� OR j u 'Co 11 c' R 6 -3 3/4" 6'-3 1/2" REF I ! r L ' --- ii I• - --- - -- -------------------- RECEPTION (E) HALLWAY (E) OFFICE los 205 a � a (E) ' 5-A �' N •I � N W i OPEN OFFICE (E OFFICE (E OFFICE 20 203 204 0 0 0 REF 5 FLOOR PLAN oRAwING TITLE: REVISED WALL TYPE TAG DRAWING: PROJECT: 15895 SW 72ND AVE SUITE 200 INFORM ACCOUNTING PORTLAND, OREGON 97224 7SW HUNZIRD, SURE 205 TIGAGA RD, OR 9722323 TEL : 5 0 3 . 2 2 6 . 1 2 8 5 SK 16 FAX : 5 0 3 . 2 2 6 . 1 6 7 0 1 JO®: 150214.01 DATE: 12.16.15 E:\adcodd\15\0214.01 Inform Accounting\Current\T1.1.dwg Dec 16, 2015 — 2:51pm © 2015 C10A, INC.ALL ROM REMM