Loading...
PFI2015-00183 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PFI2015-00183 i 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 12/10/2015 Parcel: SEG322 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Summer Lake HOA Project Description: Replace approximately 216 sq.ft. of CMU wall damaged by vehicle impact. Owner: FEES Description Date Amount PFI Permit Fee 12/07/2015 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: RALPH TURNBAUGH 7650 SW BEVELAND ST.#100 TIGARD, OR 97223 PHONE: 503-443-3900 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: Not Present Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12015-00183 Type: Condition Name: Status: Severity: PFI—Sidewalk/1 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Sidewalk/[ 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Sidewalk/[ 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Sidewalk/[ 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Sidewalk/[ 05-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI—Sidewalk/1 06-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI—Sidewalk/1 07-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI—Sidewalk/1 08-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI—Sidewalk/1 09-OTHER Applied Notice REGENEED City of Tigard DEC 0 7 2015 ■ ~ PUBLIC WORKS — ENGINEERING CITY OF TIGARD r Public Facility Improvement TV! fit DESCRIPTION OF WORK(in the right-of-way) TYPE OF WORK Check one: ❑ Utility Connection ❑ TYPE 1-Franchise Utility Work Sidewalk/driveway approach Work performed by NWN,PGE Street improvements and/or utility agency. l Detailed description: IZC��LIC� a'aokl/PW1 -01 ❑ TYPE 2-Sidewalk/Driveway/Sewer Z(b S1C -5 n i C U Work performed for the purpose of.' r Sidewalk installation or repair. • Driveway approach installation Property address/location(s): �_ C7 ��� and/or repair • Sanitary sewer lateral installation and/or main line tap ❑ TYPE 3-Full scale Development Applicant: TNt 160 e44 C44 Sit 1 4/1 Q u,✓1GC(/S Work performed with Land use approval which includes any of Address: -7(,SO 5u) /3414411) J`t. 0100 ?!6 ` the following. City/state: / ✓ , Ce L zip: -1q 2 2.3 • Subdivisions or Partitions Phone: �3-yk 3-3g Ao Email: ✓T q✓Nt IO41.4 4 N L fA1 r,,14e • Street widening I Contact name: I hTIVA 10IN41Phone: • Mainline installation for Sanitary sewer,Storm sewer,Tigard water Contractor: Oki t_ wr).'yz-t4im and/or Tigard Water Service Area CCB#: 3q q 0'9 Expiration: SUBMIT COMPLETED APPLICATION TO: Address: 13Z 55 Pi (wA j i�ym R City of Tigard City/state: 1414-e- 05N/�I UQ- Zip: �U 3S Pknning/Engineering 13125 SW Hall Blvd. Phone:_5o3-63S 6�y8 Email: i4 t4-0h4eA-CtMv ,- Tigard,OR 97223 Contact name: .lAV reT Phone: Applications for"minor work in right-of-way" onh•may be emailed to: Engineer: 54n'1e 15 4?1V1�{ nnqw;rni;zt.tigard-orgov Address: City/state: Zip: Phone: Email: Case No.: ���5=_ ���0 Contact name: .Application submittal fee: Additional fees: Estimated value of work is required(if over$5,000):$ 100 Application accepted: (within the public right-of-way) By: dL. Date: Applicati reviewed: Is work related to a LAND-USE DECISION? ❑ Yes X No S- By- Date: If so, please specify (MLP, SDR, SUB, etc.) case #: Applicant notified: Is work related to a BUILDING PERMIT? ❑ Yes 0 No By- L-'� Date: I If so,please specify(BUILDING PERMIT)case#: 1:\CURPLN\M4st•nWndUse Applk•bo": Pw 07/09nots •i.. r��i�r�1�r ri��n r�i r rin.�M+ r ,r����i�•�rrrr.•�.+ APPLICANTS NOTE: Person specified as `Applicant" shall be designated"Permittee"and shall provide financial assurance for work. *Wlten the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. 'nie owner(s)must sign flus application m the space provided or submit a written authorization with this application. r BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any deed restrictions that may be attached to or imposed upon the subject proptm. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. I • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are flue;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it.is found that any such',. statements are false. �,nl • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. SIGNATURES of each owner of the subject property required. Applicant./Authorized Agent's signature Print nameJ Date Owner's signature Print.name Date O-wner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • v wwtigard-or.gov 503-718-2421 • Page 2 of 4 •a DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL APPLICATION FEE ItEQUIREMENTS Part 1: Required submittal fee$300.00 FRANCHISE UTILITY AND SIDEWALK/ PERMIT FEE DRIVEWAY AND UTILITY Part 2: All non-water system improvements CONNECTIONS,ETC. Engineer's estimate X 5% (less$300.00 submittal fee) (work ui the right of way) Engineer's estimate X 2%Plan Review Sketch (including information below) WATER SYSTEM FEE ❑ Dimensions Part 3: All public water system improvements ❑ Street Name Engineer's estimate X 12% ❑ Site Address PFI Permit Fee Exemptions: FULL There will be no permit fee charged,or assurance required SCALE DEVELOPMENT for the following types of work: (Subdivisions/Partitions and Street Improvements) • Sidewalk repair(less than 20 lineal feet) • Relocate or replace mailbox Design Plans • Ditch cleaning that does not involve regrading. (6 sets,24x36 or 22x34) • Weephole repair ❑ Cover—Site,Vicinity,Abbreviation,Legend • Curb repair or replacement (less than 20 lineal feet) ❑ General Notes(City,Water,Sewer,etc) • Lawn sprinkler system installation or repair ❑ Street(Plan,Profile) • Street tree pruning or planting ❑ Water,Storm and Sanitary(Plan Profile) • Planter strip landscape maintenance ❑ Water Quality Facilities • Test wells ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan (Electrical,Phone,Gas, Note: A cash assurance maybe required per Storm,Sanitary,Water,Signage,Street Lights,etc) TMC 15.04.140.(customer deposit) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval PUBLIC FACILITY IMPROVEMENT PERMIT City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • -,«vwtigard-or.gov • 503-718-2421 • Page 3 of 4 SAMPLE SKETCH: SW S1 Edge of Pavement I f— Ditch —� S -Streetlight ---•--------Rain —r--- A RaDram I I 1 ' T--PWrr—5 os d'-Sel�w'e LTi n e'– � N' ►� I Existing House Existing vI 1 Driveway �r v (A 1 iLL � QI I I i Existing Shop ; Powerpole I I = 1 o • o . --------7ropertyLine----------- � I I4 1 I Fire Hydrant(FH) I Scale: 1-=30' � I � 1 I � I � MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines&dimension Slope of property Street& street name(s) Existing building,structures Utility& street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water, storm) PUBLIC FACILITY IMPROVEMENT PERMIT City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of 4 7650 S. W. Beveland St. TM RIPPEY Tigard,Oregon 97223 CONSULTING ENGINEERS Phone: (503)443-3900 Fax: (503)443-3700 STRUCTURAL CALCULATIONS RECEIVED DEC 07 2015 PROJECT: SUMMER LAKE DR-CMU WALL CITY OF TIGARD PLANNING/ENGINEERING LOCATION: 10600 SW SUMMER LAKE DR TIGARD,OREGON 97223 CLIENT: OHI CONSTRUCTION DATE: DECEMBER 7,2015 PROJECT NUMBER: 15001.27 TABLE OF CONTENTS: ITEM SHEET NUMBER CALCULATIONS Cl-C6 � INF���� cc 2 r O GO ?0,'% JC�� ti TU RN P EXPIRES i OUT oF-PUlAjr- Gc�R►� ANPrLNSI W(Nb 4e4 As (F,,. 2�. �-1� (PtSGC �L tom` 2q.11) l 0. 85 86 Psi r= 1A ac-g A5. :5�ISMIC L� See (9f. f P� Gi p Z,S K p = 2, CM ki fir•l er/2w g A s > Fe = 0.m cip bud- na. Jess =1ha-11 o.� Sns Jh JA Z o.Z15y I,,/p 8" emu we�Jk4- s s0iij -9���led W:-- o.ZB� ( 8 �s�� = 22.�t p5 TM RIPPEY BY VL DATE \X/11 CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO 16323 Tigard, Oregon 97223 Phone(503)443-3900 SHEET L'i OF l rMv WgR Oe%4 IS2 pit Mbas� �il.Z� �I�)(�,3 - 301-Z [&,4 14 As = M/ FS d = �,6 25''/2- = 3 .8125 " m;n Mise = 3o1,2 11 03?-q in•Z �!$" �jG A5 r�.2- d14 P A510 = o.oS X12' x 3.8I2s'�) o.ooi 093 Yl = ES /Em = 2q,0�o i /G qoo t�,�►= /.S l-5;)] = 01.118 0. 0235 = tem + (��j� -P" = 0. i g o• 935 d � 2 a 8 0v- Used o/G M 4 �ve%fi`��t1 r�r.��n✓c��a�a � USS CZ) � 2� 0/G 6111X TM RIPPEY BY VL DATE IMPki- CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO Tigard, Oregon 97223 Phone (503)443-3900 SHEET C Z OF z Design Maps Summary Report Page 1 of 1 Design Baps Summary Report User—Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 45.443161N, 122.807991W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III .. .i....w.......t.... .... ..........:. ... .. fit- ..... ...,........ ........,...... •....................... } :{::C'�%rs":^.^^!L'�:::::::i::::.!.::.:::::::!:. . . ... .................................. ...............:................. ............:..... ::::.:.:.•::...... .. ........................,.... .... ................ ...,.......... ....... .. ...... .. .sem...'ri<..., K<r.. py+�''g, v , , ............ t ..:....... a S: ............. ................................... .. ................_...:..::..... :......:............ ..f._<.:.>.;..::'.::i::is`:iii.:..' : �.:.......:..:::,.::•:...::.:.::...:..........:::...:......:J4 :..:::.,.:..,..:...:::. .... :.. .:::...' ::::!)fit>s::.`:'i::-::.'�..::,!::t..;.%:.:v%'.:... 't?.a'i+r:.) t...................... .... ..... IIS' ,.......:... : .. .....:.....:..... . USGS—Provided Output SS = 0.967 g SMS = 1.076 g SDs = 0.718 g Si = 0.424 g Sr,i = 0.668 g SDi = 0.446 g For information on how the SS and S1 values above have been calculated from probabilistic(risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. MCEIt Respo"se Spedrum [design Response Spectrum a cri .0,32- 4 x.33 s_l•'s4 g.d :>'&'n 1�_to 0..4 tE 7 t:to 1,23 1.44, ].gra 0,00 0.20 0. 0.F0 0.01 1.0 l,;i::£.f 1,40 1"$R) 1184 zoo perlarkL T€ s1 (Period,T(svm) .................................................................................................................................................................................................................................................................................................................................................. Although this information is a product of the U.S.Geological Survey,we provide no warranty, expressed or implied, as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. c� http://ehp 1-earthquake.cr.usgs.gov/designmaps/us/summary.php?template=minimal&latitu... 12/1/2015 V - /5 2 pI� wvr� 3.3) = Ste/. 6 �� ���� = �. 01 q T ����o���( e �c G° ✓��; F�<' Saar 01°016 q = 3. 125"- 1x 3 ' T= -A-i - 211 0 8 3,4;m �o�d s � Z' �tL•. 6A T M /d 12,0 k 2,�1 7-1 3 . X16 1 (�Ze�a✓ �615 ��. �o n� G�.��) M RI r L i BY VL DATE yY CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St, Suite 100 JOB NO I S S Z? Tigard,Oregon 97223 Phone(503) 443-3900 SHEET OF vA w.hilti.us Profis Anchor 2.4.8 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 12/1/2015 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200+Rebar A 615 Gr.60#5 Effective embedment depth: hef,opu=10.157 in.(hef,tmlt=12.500 in.) Material: ASTM A 615 GR.60 Evaluation Service Report: ESR-3187 Issued I Valid: 5/1/20141 3/1/2016 Proof: design method ACI 318-11/Chem Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,f,'=2500 psi;h=18.000 in.,Temp.short/long:32/32°F Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Geometry[in.]&Loading[lb,in.lb] Z a `i `3^ i" r 5: i, 1 C>(:: N NI s ryrfE: >:s ;?is :SS9 Ix Input data and results must be checked for agreement with the existing conditions and for plausibility! ` PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan CS www.hilti.us Profis Anchor 2.4.8 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 12/1/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[Ib] Utilization Loading Proof LoadCapacity [t"/Ov[%] Status Tension Concrete Breakout Strength 3461 3465 100/- OK Shear Concrete edge failure in direction y+ 304 2185 -/14 OK Loading ON [3v S Utilization 5Ny[%] Status Combined tension and shear loads 0.999 0.139 1.0 95 OK 3 Warnings • Please consider all details and hints/wamings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilt!product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you.Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan C6 7650 S. W. Beveland St. TM RIPPEY Tigard,Oregon 97223 CONSULTING ENGINEERS Phone: (503)443-3900 Fax: (503)443-3700 STRUCTURAL CALCULATIONS RECEIVED DEC 07 2015 PROJECT: SUMMER LAKE DR-CMU WALL CITY OF TIGARD PLANNING/ENGINEERING LOCATION: 10600 SW SUMMER LAKE DR TIGARD,OREGON 97223 CLIENT: OHI CONSTRUCTION DATE: DECEMBER 7,2015 PROJECT NUMBER: 15001.27 TABLE OF CONTENTS: ITEM SHEET NUMBER CALCULATIONS Cl-C6 It PROfff 2 rr o GO 20,1 JCS 'y TU RPlBP EXPIRES: 6 3o S. &QAD ANI�LHS15 . WiNn F=IA 464 AS (Ej- 29, Cx�. 6 J �,55L, i F h ac-1 AS ?-5. 35 4' cJ (6&-C) �ISMIC. L> sec 4'k-a6he'd t 2 h � (eq, 13.3-1� CSP l TPS elp=Z.S R? _ 2,s j!fMk,fiilevw ZIA _ D F� = a m pe bWr nab less 'A�� o,� Sns Th wp Z o.2 iso ✓,✓p gra CMV wea � I $ /�5 So Itl -q✓R+� lef� CGO✓1S�i�Uy�I J TM RIPPEY BY V(- DATE ]]]LLL CONSULTING ENGINEERS CHK BY__DATE_______ 7650 S.W.Beveland St, Suite 100 JOB NO 16323 Tigard, Oregon 97223 Phone(503)443-3900 SHEET G'1 OF C M v w�R pe-s►Jh (n.3s ins k)r)$ = IS2. pit (L/L;(-) vy�isc - o G 152 p I l) = Mbgs� (git.27 pig)(:3,3') - 301-z lb,k- / (A-50) AsM;., = M/ FS J A 2S'/2 = 3.8125 " Mase = 3o1.2 Ib = 3.6111 �5/Y„rn (3.6 M J"l / � /(32 d, 0 3 Zqin•Z / J L& P` A,5 2 3.8125`+� = o.oala93 n = ESI , = 21, /CgOo �M= l.sl�s )� = 2t.Di �r � = o. 023c � = � ' ��3 = o• 935 Fin - 3 'M (;, , =S�o�O�f .� , - 2 USB J �Ig`` 0(Gyv��ik �U�/hG�i� :%1.4�v���.a!) U 5G (2) TM RiPPEV BY V L DATE Y CONSULTING ENGINEERS CHK BY DATE 7650 S.W.Beveland St, Suite 100 JOB NO /S-S23 Tigard, Oregon 97223 Phone(503) 443-3900 SHEET C 2• of Design Maps Summary Report Page 1 of 1 Design Maps Summary Report User-Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 45.443160N, 122.80799°W Site Soil Classification Site Class D — "Stiff Soil" Risk Category I/II%III am ay�.r .:.:...:... » ......:........ .....:...: ..... .... ... .................. ...... . ....................................... v' :::`iso;;::::%?<:F:E;Ei!Y.3[:;sx's:,, ';:7:` :.•�g`�';; �> A w Y " ...... .:.::�..is»:... ..:::.'.L.::::..........a.. '. i; RqY .... ............. .. .... ............. ............_.................,. ..,......_.. tet' :f S� x.. , ............. $ y.. s ...:........... ........,....:....<....................... ........... ........ ...:...... .... .......:. . USGS-Provided Output S5 = 0.967g S,s = 1.076g Soy = 0.718g Sl = 0.424 g S,1 = 0.668 g Spl = 0.446 g For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. MCEp Response Spedrutn Design Response Spectrum X5. 5 co 0•�2 x.33 03G x•.11' G:�& " 001 1 0.20 9.10 OAO 0.10 1.:03 1120 1.40 1.40 1.90 a.00 .mo 0.20 0,40 0.rw 0.ry i.Co 1"zo 1:.v) I,uw 1:94 2.00 Ppriog.s T i"-€1 peri-ed.T 4er'I ......................................................................................................................................................................................................................................................................................I..................................................1111..... Although this information is a product of the U.S.Geological Survey,we provide no warranty, expressed or implied, as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. http://ehp 1-earthquake.cr.usgs.gov/designmaps/us/summary.php?templ ate=minimal&latitu... 12/1/2015 V 3.3') = 5�I. 6 19 k'�� _� U = 152 p I (bi') = h o s # -M�, - 2�i.o8 �i•In 3,X19" - 6.9 ! JfF 12. 011 �,y7-1 3 . 161 bid. � ti(Lil ' ki 17 H 2rO' A-0lIFSI Vr (2ei�av A 615 Civ. 4o ov 6,.6 o) TM RIEPPEY BY VL DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOBNO IG,Z? Tigard, Oregon 97223 Phone(503) 443-3900 SHEET OF www.hilti.us Profis Anchor 2.4.8 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 12/1/2015 E-Mail: Specifter's comments: 1 Input data �Lt9,°y499°�°°e��sW Anchor type and diameter: HIT-HY 200+Rebar A 615 Gr.60#5 Effective embedment depth: hefopu=10.157 in (herj_t=12.500 in.) Material: ASTM A 615 GR 60 Evaluation Service Report: ESR-3187 Issued I Valid. 5/1/2014 13/1/2016 Proof: design method ACI 318-11 /Chem Stand-off installation: -(Recommended plate thickness:not calculated) Profile: no profile Base material: cracked concrete,2500,f,,=2500 psi;h=18.000 in.,Temp.short/long.32/32`F Installation: hammer drilled hole,installation condition:dry Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Geometry[in.]&Loading[Ib,in.lb] Z to O k� y SV�I'J.r" \ x Input data and results must be checked for agreement with the existing conditions and for plausibility! \ PROFIS Anchor(c)2003-2009 Hilti AG,R-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan CS 122 www.hilti.us Profis Anchor 2.4.8 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 12/1/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values[lb] Utilization Loading Proof Load Capacity VN/pv[%] Status Tension Concrete Breakout Strength 3461 3465 100/_ OK Shear Concrete edge failure In direction y+ 304 2185 -/14 OK Loading ON [iv C Utilization pN,v[°/a] Status Combined tension and shear loads 0.999 0.139 1.0 95 OK 3 Warnings - Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties - Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you.Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to Interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. - You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis.If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hiltl AG,FL-9494 Schaan Hilb is a registered Trademark of Hlltl AG,Schaan �1