Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (3)
ITABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS l PAGE# DESCRIPTION SOLAR MODULES • SYSTEM SIZE:4400W DC, 3840W AC ti PV-1.0 COVER SHEET • ALL WORK SHALL COMPLY WITH 2014 NEC, 2012 IBC, MUNICIPAL CODE,AND SERVICE ENTRANCE RAIL . • MODULES: (16) REC SOLAR: REC275TP ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. ' PV-2.0 SITE PLAN • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. I Mp _ v 111 (1)ABB: PVI-3.6-OUTD-S-US-A(240 V) • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MAIN PANEL PV 3.0 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703: SP SUB-PANEL STANDOFFS& PV-5.0 SIGNAGE • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741! FOOTINGS • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. P� Y • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER690.31(E)AND 2012 n PV LOAD CENTER 11 CHIMNEY ALUM. }� • • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. NOV 1 6 2015 • 9.38 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ATTIC VENT •• • 14.65 AMPS DERATED SHORT CIRCUIT CURRENT(690.8 (a)&690.8(b)). ���� B�fl� CJ FLUSH ATTIC VENT PM DEDICATED PV METER BUILDING DID S ON • FIREFIGHTER ACCESS: 12" PATHWAY ALONG a PVC PIPE VENT EACH SIDE OF ANY HORIZONTAL RIDGE. INVERTER(S)WITH • ROOF AREA: 2845 SQ.FT. METAL PIPE VENT INV INTEGRATED DC ARRAY AREA: 272 SQ.FT. DISCONNECT AND AFCI ECEIVED COVERAGE: 10% �:i T-VENT AC AC DISCONNECT(S) N°V 12 2015 SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKS Washington County • • �" Building Services CB COMBINER BOX HARDSCAPE INTERIOR EQUIPMENT —PL— PROPERTY LINE s u n r u n J SHOWN AS DASHED SCALE: NTS A AMPERE - AC ALTERNATING.CURRENka ^r TIGARD _. AFCI ARC FAULT IRCUIT IN- j 180464 AZIM AZIMUTH REVIEWED FOR CODE COMPLI VICINITY MAP COMP COMPOSITI• 1, ....--- x_ / i."4-41:: . PHONE 888.657.6527 (E) EXISTING i - I EXT EXTERIOR Permit# l,Z,�LjT`2[j CS- n k CUSTOMER RESIDENCE: FRM FRAMING INT INTERIOR Address: 141 t ( t� I��7- kwA i I -W 120TH PL, TIGARD, ��1 �' LBW LOAD BEAR tt&I L O 97224 U A A!_ R A A ' i rr,n$$,,��.. ., MSP MAIN SERVr 'P' ► •O� Dates ( o a 7263 APN#:2S11OBBO6lOO Tigard (N) NEW a NTS NOT TO SCALE ' a g� PROJECT NUMBER: OC ON CENTER OFFICE COPY 601 R-111 HENR ,6107) • • • PRE-FAB PRE-FABRICATED •• WASHINGTON COUNTY BUILDING DIVISION { PSF POUNDS PER SQUARE FOOT DESIGNER: - PV PHOTOVOLTAIC A. KRISHNAN 14111 SW 120th P1 -1 ` DATE BY _._ — -- _ -----_ TL TRANSFORMERLESS DRAFTER: TYP TYPICAL PROJECT#____.__---------_-_-- _ _._.___ v VOLTS DI W WATTS SHEET PERMIT# rr �- --- REV NAME DATE COMMENTS COVER SHEET ssw BLDG -------- A �� - REV:A 11/3/2015 ng City PAGE PV-1 .0 SITE PLAN -SCALE=3/32"= r-0" i PITCH TRUE MAG PV AREA AZIM AZIM (SOFT) AR-01 32° 180° 164° 283.8 \N/ - PL PL PL PL PL PL PL PL a J 4 d . . • d a • / . . O • Q . . . dd g Q 111 EJ- 1 EJ O I I ° d C d sunrun . a a a a cn p . L --. a °a a o• a -o OR CL#180464 _ r A 4d d 3380 S E 20TH,PORTLAND,OR 97202 _ d PHONE 888.657.6527 A a FAX 503.205.0748 J o CUSTOMER RESIDENCE:/ i N . .. �d ° °a GARY HENRY a d c 14111 SW 120TH PL, TIGARD, ^ OR, 97224 PL PL PL PL PL PL PL TEL.(503)458-7263 APN#:251 1 088061 00 PROJECT NUMBER: 601R-111HENR FIRE SETBACKS (N)ARRAY AR-01 PL • DESIGNER: r- (1'TYP) MP A. KRISHNAN (E) RESIDENCE _ I ar (S-1 7 NV DRAFTER: L J `!L1 DI SHEET SITE PLAN REV:A 11/3/2015 PAGE PV-2.O ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA ROOF TYPE ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPAN OVERHANG - ' MODULES- AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER 2 X 8 12'-0" 24" NO 4'-0" 1'-4" REC SOLAR: REC275TP MODULE DIMS: • D1 -AR-01 -SCALE: 1/4"= 1' ♦ INDICATES TSRF VALUE AT MARKED LOCATION. 65.5"x 39"x 1.5" PITCH: 32° MAX DISTRIBUTED LOAD: 3 PSF AZIM: 180° SNOW LOAD: 25 PSF _ r--� WIND SPEED: ,,F I I H I I L I 95 MPH 3-SEC GUST. 0 © A. LAG SCREWS:Ai& 5 5/16"x3.5": 2.5"MIN EMBEDMENT 93 % 92 % 92 % PENETRATION SPACING: - O— — o STAGGERED g-10" O , 6-7" 10 -e e- — o— e- -- 0 /z\i. 89% — 89 % 12' —O e- o e- —o -e e- 27'-6° - . -o e- — o 1 — e- -- o— -e e- -o -o — e. —o -e _ - — -e. — e- o . /90__. '-4'TYP-T-81-% 7-8% ' 7-8-% 85 /o 11" sunrun / 5'-3" l' 33'-4" 6-8" 1" OR CL#180464 ROOF FRAMING DETAIL-SCALE: NTS ELEVATION VIEW-SCALE: NTS 3380SE 20TH,PORTLAND,OR 97202 PHONE 888.657.6527 FAX 503.205 0748 3'-3" CUSTOMER RESIDENCE: .-.‘ GARY HENRY PV MODULES A616../ 6 MAX 14111 SW 120TH PL, TIGARD, PENETRATIONS �12 V OR, 97224 2X8 RAFTERS ♦ ' TEL.(503)458-7263 APN#:28110131306100 #� PROJECT NUMBER: 601R-111HENR - COMP SHINGLE ►' Adirtfill 17151'-6"DESIGNER: 9' 10" 2' 8" - A. KRISHNAN _ . rI∎∎∎∎rl LLLLLLLLLLLLLLLLLLLLLLLL I- DRAFTER: • ..��■■.I.. LLLLLLLLLLLLLLLLLLLLLLLL 1� DI I�-�--' LLLLLLLLLLLLLLLLLLLLLLLL- ��'-I-i! LLLLLLLLLLLLLLLLLLLLLLLL �smi�iim- LLLLLLLLLLLLLLLLLLLLLLLL 6834'-3" • LLLLLLLLLLLLLLLLLLLLLLLL SHEET ......,=7:. LLLLLLLLLLLLLLLLLLLLLLLL.. Jul�I�� LLLLLLLLLLLLLLLLLLLLLLLL: LAYOUT .�-�--,I LLLLLLLLLLLLLLLLLLLLLLLL 2••=1�I=- LLLLLLLLLLLLLLLLLLLLLLLL i- :=== LLLLLLLLLLLLLLLLLLLLLLLLIl ' - REV:A 11/3/2015 PAGE PV-3.0 d 120/240 VAC SINGLE PHASE SERVICE METER#: (.1.0 PGE 24317662 UTILITY GRID EXISTING C 200A MAIN BREAKER (END FED) EXISTING PV MODULES 200A MAIN ABB: PVI-3.6-OUTD-S-US-A (240 V) REC SOLAR: REC275TP FACILITY PANEL METER RUN 3600 WATT INVERTER — +, // (8) MODULES LOADS 2 �1 `N (1) STRING OF (8) MODULES if3 3 7/' -0 e- o—��o I I PV MODULES FACILITY - JUNCTION BOX / REC SOLAR: REC275TP 20A PV GROUND 250V METER SOCKET DUAL MPPT TRACKERS STRING MIN RATED NEMA3R — +O// (8) MODULES BREAKER AT 125A CONTINUOUS& COMBINER& LOAD RATED DC - (1) STRING OF (8) MODULES OPPOSITE END OF 240V METER fISC:ONNFC;T ANIn AFC:I BUSBAR FROM 200A, FORM 2S MAIN BREAKER CONDUIT SCHEDULE NOTES TO INSTALLER: # CONDUIT CONDUCTOR NEUTRAL GROUND 2. IN THE MAIN PANEL, REPLACE(4)20A/1P FULL SIZE BREAKERS WITH (2) surirun 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 20A/1 P 20/1P TWIN BREAKERS. 2 3/4"EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 OR CL#180464 3380 S E 20TH,PORTLAND,OR 97202 PHONE 888 657 6527 FAX 503 205 0748 MODULE CHARACTERISTICS CUSTOMER RESIDENCE: GARY HENRY REC SOLAR: REC275TP 275 W 14111 SW 120TH PL, TIGARD, OPEN CIRCUIT VOLTAGE 38.3 V OR, 97224 MAX POWER VOLTAGE 31.5 V TEL.(503)458-7263 APN#:251108806100 SHORT CIRCUIT CURRENT 9.38 A PROJECT NUMBER: 601 R-111 HENR SYSTEM CHARACTERISTICS -INVERTER 1 DESIGNER: SYSTEM SIZE 4400 W A. KRISHNAN SYSTEM OPEN CIRCUIT VOLTAGE 338 V DRAFTER: DI SYSTEM OPERATING VOLTAGE 252 V SHEET MAX ALLOWABLE DC VOLTAGE 600 V ELECTRICAL SYSTEM OPERATING CURRENT 17.48 A SYSTEM SHORT CIRCUIT CURRENT 23.45 A REV:A 11/3/2015 PER CODE:690.52 PAGE PV-4.0 • A WARNING ° J oToeod4nEg @V@UtW cap DI'SCONMI g7 ®TOVo14n5g @Wg4ffIN ELECTRIC SHOCK HAZARD RATED M A(`© OPE M TEMSM©��/m 2©°0 0 VOLTS ( EQUB ADD L,'O RAPID • IF A GROUND FAULT IS INDICATED NOM ""` \L O D U ENS VOLTAGE �e VOLT G JUTDO�Jn Gil NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: • LABEL LOCATION: (PER CODE:NEC690.54) AC DISCONNECT,DC DISCONNECT,POINT OF INTERCONNECTION DC DISCONNECT,INVERTER (PER CODE:NEC 690.35(F)) IA ARNBE ryO (PER CODE:NEC690.56(C)) [To be used when inverter is ungrounded] B VR f�1 Q OUTPUT C OO G NECTRO 1 DO NOT • A WARNING RELOO CAm TBS OVERCURRENT DDEVE LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION THE DC CONDUCTORS OF THIS (PER CODE:NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings PHOTOVOLTAIC SYSTEM ARE UNGROUNDED of all overcurrent devices supplying it] AND MAY BE ENERGIZED . LABEL LOCATION: CAUTION : SOLAR CIRCUIT DC DISCONNECT,INVERTER • (PER CODE:NEC 690.35(F)) LABEL LOCATION: [To be used when inverter is ungrounded] MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES, A WARNING AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE:IFC605.11.1.4) ELECTRIC SHOCK HAZARD SOS fl 3 (\(� -SCONEC U DO NOT TOUCH TERMINALS U�JI� • TERMINALS ON BOTH LINE AND LOAD SIDES MAY.BE ENERGIZED LABEL LOCATION: IN THE OPEN POSITION DISCONNECT,POINT OF INTERCONNECTION • (PER CODE:NEC690.13(B)) • DC VOLTAGE IS ALWAYS PRESENT INVERTER 1 • WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT G2JU o IMEKIMI POWER- 17.48 Q LABEL LOCATION: POhNT QED AC DISCONNECT,POINT OF INTERCONNECTION Q` POWER- sunrun (PER CODE:NEC 690.17(E)) POINT , ,`M&Q(Vmp)) 350 W • - MAX•IIMUM Q 'i1 VU A WARNING cca4/ (VOC) 500 W • MAMMUM GI'RGUIT ELECTRIC SHOCK HAZARD QED 23.45 GJ OR CL#180464 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LABEL LOCATION: 3380 S E 20TH,PORTLAND,OR 97202 LOAD SIDES MAY BE ENERGIZED DC DISCONNECT,INVERTER FAX 5032os6 sz7 0748 IN THE OPEN POSITION (PER CODE:NEC690.53) • LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION CUSTOMER RESIDENCE: PER CODE:NEC 690.17(E),CB WARNING DUAL POWER SOURCE GARY HENRY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING-[ n Shock Hazard LABEL LOCATION: OR 14111 9 SW 120TH PL, TIGARD,_ libecag7gadECt9ciat3t1xetti ihr POINT OF INTERCONNECTION •@taLiauthorized E zti: provider for assistance (PER CODE:NEC 705.12(D)(4)) TEL.(503)458-7263 APN#:2S110BB06100 LABEL LOCATION: • PROJECT NUMBER: INVERTER,JUNCTION BOXES(ROOF),AC DISCONNECT CAUTION:SOLAR ELECTRIC 601 R 111 HENR (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) SYSTEM CONNECTED WARNING: PHOTOVOLVM DESIGNER: LABEL LOCATION: POWER SOURCE POINT OF INTERCONNECTION LABEL LOCATION: (PER CODE:NEC690.15,690.13(B)) A. KRISHNAN CONDUIT,COMBINER BOX DRAFTER: (PER CODE:NEC690.31(G)(3)(4)&NEC 690.13(G)(4) DI • ADHESIVE FASTENED SIGNS: SHEET •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT SIG NAG E WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. REV: A 11/3/2015 •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER PAGE PV-5.0 RESISTANT[IFC 605.11.1.3] - . NOTES: ' REVISION: - 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS �� �� STEP 3: PLACE L FOOT - TORQUE ALL 5/16" HARDWARE TO i ON TOP OF SNAPNRACK -\ THE FOLLOWING: I AND TIGHTEN UTNG COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS I CAN BE MOUNTED IN 5 S.S. FLANGE NUT - BLACK S.S. 7-9 FT-LBS j ; STEP 2: SLIP FLASHING OVER ANY ORIENTATION \v I - RAILS CAN MOUNT TO EITHER SIDE % L FOOT BASE AND UNDER ROW ---- X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) \\ ?\ - OF SHINGLES ABOVE 1 SNAPNRACK S.S. BOLT AND ==j0-,? CHANNEL NUT SPLIT WASHER -- - \ I ; \'', '�; '--- ' %----_---- - � ' S.S. LAG SCREW - <---z--1, y i i WITH FLAT WASHER SNAPNRACK �, ; %` 2.5" MINIMUM EMBEDMENT :, • STANDARD RAIL ,i' IS STANDARD ;- -- - -- SNAPNRACK COMPOSITION - i� STEP 1: BOLT L FOOT ROOF FLASHING - ::-�� " \ - \ ",- BASE TO ROOF WITH ,i" LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. , , % N \i , ROOF DECKING TYP. i A FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES - - ' " WITH LOW TO MODERATE TILT _,,,..- \ \'\ \ \ \,, RAILS CAN BE LEVELED UP TO 3" USING \ ; ~�\\ UP TO TWO LEVELING SPACERS LEVELING" \\ /�// COMPLETED INSTALLATION I SHOWN IN "SERIES 100 RAIL LE G \ %' RAFTER TYP. \_ DRAFTER: D Ryan A E: DNS : O- Six ��� MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: PART NUMBER: DESCRIPTION: REV �\\��(((/�(�\���� 775FIER0 340,USA PEN DETAIL 01 FLASHED L FOOT TO F����JJ PANE.SUITE AN LUIS OISPO. 701 DATE: S100 PEN D01 RAFTER • f I PY cxurItBang fteso osuza =Ei o m ;Eg .zzz r..,.-=,-- APPROVED BY 120113