Loading...
Plans (3) ITABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS l PAGE# DESCRIPTION SOLAR MODULES • SYSTEM SIZE:4400W DC, 3840W AC ti PV-1.0 COVER SHEET • ALL WORK SHALL COMPLY WITH 2014 NEC, 2012 IBC, MUNICIPAL CODE,AND SERVICE ENTRANCE RAIL . • MODULES: (16) REC SOLAR: REC275TP ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. ' PV-2.0 SITE PLAN • INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. I Mp _ v 111 (1)ABB: PVI-3.6-OUTD-S-US-A(240 V) • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MAIN PANEL PV 3.0 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703: SP SUB-PANEL STANDOFFS& PV-5.0 SIGNAGE • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741! FOOTINGS • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. P� Y • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER690.31(E)AND 2012 n PV LOAD CENTER 11 CHIMNEY ALUM. }� • • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. NOV 1 6 2015 • 9.38 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ATTIC VENT •• • 14.65 AMPS DERATED SHORT CIRCUIT CURRENT(690.8 (a)&690.8(b)). ���� B�fl� CJ FLUSH ATTIC VENT PM DEDICATED PV METER BUILDING DID S ON • FIREFIGHTER ACCESS: 12" PATHWAY ALONG a PVC PIPE VENT EACH SIDE OF ANY HORIZONTAL RIDGE. INVERTER(S)WITH • ROOF AREA: 2845 SQ.FT. METAL PIPE VENT INV INTEGRATED DC ARRAY AREA: 272 SQ.FT. DISCONNECT AND AFCI ECEIVED COVERAGE: 10% �:i T-VENT AC AC DISCONNECT(S) N°V 12 2015 SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKS Washington County • • �" Building Services CB COMBINER BOX HARDSCAPE INTERIOR EQUIPMENT —PL— PROPERTY LINE s u n r u n J SHOWN AS DASHED SCALE: NTS A AMPERE - AC ALTERNATING.CURRENka ^r TIGARD _. AFCI ARC FAULT IRCUIT IN- j 180464 AZIM AZIMUTH REVIEWED FOR CODE COMPLI VICINITY MAP COMP COMPOSITI• 1, ....--- x_ / i."4-41:: . PHONE 888.657.6527 (E) EXISTING i - I EXT EXTERIOR Permit# l,Z,�LjT`2[j CS- n k CUSTOMER RESIDENCE: FRM FRAMING INT INTERIOR Address: 141 t ( t� I��7- kwA i I -W 120TH PL, TIGARD, ��1 �' LBW LOAD BEAR tt&I L O 97224 U A A!_ R A A ' i rr,n$$,,��.. ., MSP MAIN SERVr 'P' ► •O� Dates ( o a 7263 APN#:2S11OBBO6lOO Tigard (N) NEW a NTS NOT TO SCALE ' a g� PROJECT NUMBER: OC ON CENTER OFFICE COPY 601 R-111 HENR ,6107) • • • PRE-FAB PRE-FABRICATED •• WASHINGTON COUNTY BUILDING DIVISION { PSF POUNDS PER SQUARE FOOT DESIGNER: - PV PHOTOVOLTAIC A. KRISHNAN 14111 SW 120th P1 -1 ` DATE BY _._ — -- _ -----_ TL TRANSFORMERLESS DRAFTER: TYP TYPICAL PROJECT#____.__---------_-_-- _ _._.___ v VOLTS DI W WATTS SHEET PERMIT# rr �- --- REV NAME DATE COMMENTS COVER SHEET ssw BLDG -------- A �� - REV:A 11/3/2015 ng City PAGE PV-1 .0 SITE PLAN -SCALE=3/32"= r-0" i PITCH TRUE MAG PV AREA AZIM AZIM (SOFT) AR-01 32° 180° 164° 283.8 \N/ - PL PL PL PL PL PL PL PL a J 4 d . . • d a • / . . O • Q . . . dd g Q 111 EJ- 1 EJ O I I ° d C d sunrun . a a a a cn p . L --. a °a a o• a -o OR CL#180464 _ r A 4d d 3380 S E 20TH,PORTLAND,OR 97202 _ d PHONE 888.657.6527 A a FAX 503.205.0748 J o CUSTOMER RESIDENCE:/ i N . .. �d ° °a GARY HENRY a d c 14111 SW 120TH PL, TIGARD, ^ OR, 97224 PL PL PL PL PL PL PL TEL.(503)458-7263 APN#:251 1 088061 00 PROJECT NUMBER: 601R-111HENR FIRE SETBACKS (N)ARRAY AR-01 PL • DESIGNER: r- (1'TYP) MP A. KRISHNAN (E) RESIDENCE _ I ar (S-1 7 NV DRAFTER: L J `!L1 DI SHEET SITE PLAN REV:A 11/3/2015 PAGE PV-2.O ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA ROOF TYPE ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL FRAME TYPE SIZE SPAN SPACING ZONE SPAN OVERHANG - ' MODULES- AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER 2 X 8 12'-0" 24" NO 4'-0" 1'-4" REC SOLAR: REC275TP MODULE DIMS: • D1 -AR-01 -SCALE: 1/4"= 1' ♦ INDICATES TSRF VALUE AT MARKED LOCATION. 65.5"x 39"x 1.5" PITCH: 32° MAX DISTRIBUTED LOAD: 3 PSF AZIM: 180° SNOW LOAD: 25 PSF _ r--� WIND SPEED: ,,F I I H I I L I 95 MPH 3-SEC GUST. 0 © A. LAG SCREWS:Ai& 5 5/16"x3.5": 2.5"MIN EMBEDMENT 93 % 92 % 92 % PENETRATION SPACING: - O— — o STAGGERED g-10" O , 6-7" 10 -e e- — o— e- -- 0 /z\i. 89% — 89 % 12' —O e- o e- —o -e e- 27'-6° - . -o e- — o 1 — e- -- o— -e e- -o -o — e. —o -e _ - — -e. — e- o . /90__. '-4'TYP-T-81-% 7-8% ' 7-8-% 85 /o 11" sunrun / 5'-3" l' 33'-4" 6-8" 1" OR CL#180464 ROOF FRAMING DETAIL-SCALE: NTS ELEVATION VIEW-SCALE: NTS 3380SE 20TH,PORTLAND,OR 97202 PHONE 888.657.6527 FAX 503.205 0748 3'-3" CUSTOMER RESIDENCE: .-.‘ GARY HENRY PV MODULES A616../ 6 MAX 14111 SW 120TH PL, TIGARD, PENETRATIONS �12 V OR, 97224 2X8 RAFTERS ♦ ' TEL.(503)458-7263 APN#:28110131306100 #� PROJECT NUMBER: 601R-111HENR - COMP SHINGLE ►' Adirtfill 17151'-6"DESIGNER: 9' 10" 2' 8" - A. KRISHNAN _ . rI∎∎∎∎rl LLLLLLLLLLLLLLLLLLLLLLLL I- DRAFTER: • ..��■■.I.. LLLLLLLLLLLLLLLLLLLLLLLL 1� DI I�-�--' LLLLLLLLLLLLLLLLLLLLLLLL- ��'-I-i! LLLLLLLLLLLLLLLLLLLLLLLL �smi�iim- LLLLLLLLLLLLLLLLLLLLLLLL 6834'-3" • LLLLLLLLLLLLLLLLLLLLLLLL SHEET ......,=7:. LLLLLLLLLLLLLLLLLLLLLLLL.. Jul�I�� LLLLLLLLLLLLLLLLLLLLLLLL: LAYOUT .�-�--,I LLLLLLLLLLLLLLLLLLLLLLLL 2••=1�I=- LLLLLLLLLLLLLLLLLLLLLLLL i- :=== LLLLLLLLLLLLLLLLLLLLLLLLIl ' - REV:A 11/3/2015 PAGE PV-3.0 d 120/240 VAC SINGLE PHASE SERVICE METER#: (.1.0 PGE 24317662 UTILITY GRID EXISTING C 200A MAIN BREAKER (END FED) EXISTING PV MODULES 200A MAIN ABB: PVI-3.6-OUTD-S-US-A (240 V) REC SOLAR: REC275TP FACILITY PANEL METER RUN 3600 WATT INVERTER — +, // (8) MODULES LOADS 2 �1 `N (1) STRING OF (8) MODULES if3 3 7/' -0 e- o—��o I I PV MODULES FACILITY - JUNCTION BOX / REC SOLAR: REC275TP 20A PV GROUND 250V METER SOCKET DUAL MPPT TRACKERS STRING MIN RATED NEMA3R — +O// (8) MODULES BREAKER AT 125A CONTINUOUS& COMBINER& LOAD RATED DC - (1) STRING OF (8) MODULES OPPOSITE END OF 240V METER fISC:ONNFC;T ANIn AFC:I BUSBAR FROM 200A, FORM 2S MAIN BREAKER CONDUIT SCHEDULE NOTES TO INSTALLER: # CONDUIT CONDUCTOR NEUTRAL GROUND 2. IN THE MAIN PANEL, REPLACE(4)20A/1P FULL SIZE BREAKERS WITH (2) surirun 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 20A/1 P 20/1P TWIN BREAKERS. 2 3/4"EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 OR CL#180464 3380 S E 20TH,PORTLAND,OR 97202 PHONE 888 657 6527 FAX 503 205 0748 MODULE CHARACTERISTICS CUSTOMER RESIDENCE: GARY HENRY REC SOLAR: REC275TP 275 W 14111 SW 120TH PL, TIGARD, OPEN CIRCUIT VOLTAGE 38.3 V OR, 97224 MAX POWER VOLTAGE 31.5 V TEL.(503)458-7263 APN#:251108806100 SHORT CIRCUIT CURRENT 9.38 A PROJECT NUMBER: 601 R-111 HENR SYSTEM CHARACTERISTICS -INVERTER 1 DESIGNER: SYSTEM SIZE 4400 W A. KRISHNAN SYSTEM OPEN CIRCUIT VOLTAGE 338 V DRAFTER: DI SYSTEM OPERATING VOLTAGE 252 V SHEET MAX ALLOWABLE DC VOLTAGE 600 V ELECTRICAL SYSTEM OPERATING CURRENT 17.48 A SYSTEM SHORT CIRCUIT CURRENT 23.45 A REV:A 11/3/2015 PER CODE:690.52 PAGE PV-4.0 • A WARNING ° J oToeod4nEg @V@UtW cap DI'SCONMI g7 ®TOVo14n5g @Wg4ffIN ELECTRIC SHOCK HAZARD RATED M A(`© OPE M TEMSM©��/m 2©°0 0 VOLTS ( EQUB ADD L,'O RAPID • IF A GROUND FAULT IS INDICATED NOM ""` \L O D U ENS VOLTAGE �e VOLT G JUTDO�Jn Gil NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: • LABEL LOCATION: (PER CODE:NEC690.54) AC DISCONNECT,DC DISCONNECT,POINT OF INTERCONNECTION DC DISCONNECT,INVERTER (PER CODE:NEC 690.35(F)) IA ARNBE ryO (PER CODE:NEC690.56(C)) [To be used when inverter is ungrounded] B VR f�1 Q OUTPUT C OO G NECTRO 1 DO NOT • A WARNING RELOO CAm TBS OVERCURRENT DDEVE LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION THE DC CONDUCTORS OF THIS (PER CODE:NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings PHOTOVOLTAIC SYSTEM ARE UNGROUNDED of all overcurrent devices supplying it] AND MAY BE ENERGIZED . LABEL LOCATION: CAUTION : SOLAR CIRCUIT DC DISCONNECT,INVERTER • (PER CODE:NEC 690.35(F)) LABEL LOCATION: [To be used when inverter is ungrounded] MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES, A WARNING AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE:IFC605.11.1.4) ELECTRIC SHOCK HAZARD SOS fl 3 (\(� -SCONEC U DO NOT TOUCH TERMINALS U�JI� • TERMINALS ON BOTH LINE AND LOAD SIDES MAY.BE ENERGIZED LABEL LOCATION: IN THE OPEN POSITION DISCONNECT,POINT OF INTERCONNECTION • (PER CODE:NEC690.13(B)) • DC VOLTAGE IS ALWAYS PRESENT INVERTER 1 • WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT G2JU o IMEKIMI POWER- 17.48 Q LABEL LOCATION: POhNT QED AC DISCONNECT,POINT OF INTERCONNECTION Q` POWER- sunrun (PER CODE:NEC 690.17(E)) POINT , ,`M&Q(Vmp)) 350 W • - MAX•IIMUM Q 'i1 VU A WARNING cca4/ (VOC) 500 W • MAMMUM GI'RGUIT ELECTRIC SHOCK HAZARD QED 23.45 GJ OR CL#180464 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LABEL LOCATION: 3380 S E 20TH,PORTLAND,OR 97202 LOAD SIDES MAY BE ENERGIZED DC DISCONNECT,INVERTER FAX 5032os6 sz7 0748 IN THE OPEN POSITION (PER CODE:NEC690.53) • LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION CUSTOMER RESIDENCE: PER CODE:NEC 690.17(E),CB WARNING DUAL POWER SOURCE GARY HENRY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING-[ n Shock Hazard LABEL LOCATION: OR 14111 9 SW 120TH PL, TIGARD,_ libecag7gadECt9ciat3t1xetti ihr POINT OF INTERCONNECTION •@taLiauthorized E zti: provider for assistance (PER CODE:NEC 705.12(D)(4)) TEL.(503)458-7263 APN#:2S110BB06100 LABEL LOCATION: • PROJECT NUMBER: INVERTER,JUNCTION BOXES(ROOF),AC DISCONNECT CAUTION:SOLAR ELECTRIC 601 R 111 HENR (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) SYSTEM CONNECTED WARNING: PHOTOVOLVM DESIGNER: LABEL LOCATION: POWER SOURCE POINT OF INTERCONNECTION LABEL LOCATION: (PER CODE:NEC690.15,690.13(B)) A. KRISHNAN CONDUIT,COMBINER BOX DRAFTER: (PER CODE:NEC690.31(G)(3)(4)&NEC 690.13(G)(4) DI • ADHESIVE FASTENED SIGNS: SHEET •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT SIG NAG E WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. REV: A 11/3/2015 •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER PAGE PV-5.0 RESISTANT[IFC 605.11.1.3] - . NOTES: ' REVISION: - 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS �� �� STEP 3: PLACE L FOOT - TORQUE ALL 5/16" HARDWARE TO i ON TOP OF SNAPNRACK -\ THE FOLLOWING: I AND TIGHTEN UTNG COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS I CAN BE MOUNTED IN 5 S.S. FLANGE NUT - BLACK S.S. 7-9 FT-LBS j ; STEP 2: SLIP FLASHING OVER ANY ORIENTATION \v I - RAILS CAN MOUNT TO EITHER SIDE % L FOOT BASE AND UNDER ROW ---- X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) \\ ?\ - OF SHINGLES ABOVE 1 SNAPNRACK S.S. BOLT AND ==j0-,? CHANNEL NUT SPLIT WASHER -- - \ I ; \'', '�; '--- ' %----_---- - � ' S.S. LAG SCREW - <---z--1, y i i WITH FLAT WASHER SNAPNRACK �, ; %` 2.5" MINIMUM EMBEDMENT :, • STANDARD RAIL ,i' IS STANDARD ;- -- - -- SNAPNRACK COMPOSITION - i� STEP 1: BOLT L FOOT ROOF FLASHING - ::-�� " \ - \ ",- BASE TO ROOF WITH ,i" LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. , , % N \i , ROOF DECKING TYP. i A FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES - - ' " WITH LOW TO MODERATE TILT _,,,..- \ \'\ \ \ \,, RAILS CAN BE LEVELED UP TO 3" USING \ ; ~�\\ UP TO TWO LEVELING SPACERS LEVELING" \\ /�// COMPLETED INSTALLATION I SHOWN IN "SERIES 100 RAIL LE G \ %' RAFTER TYP. \_ DRAFTER: D Ryan A E: DNS : O- Six ��� MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: PART NUMBER: DESCRIPTION: REV �\\��(((/�(�\���� 775FIER0 340,USA PEN DETAIL 01 FLASHED L FOOT TO F����JJ PANE.SUITE AN LUIS OISPO. 701 DATE: S100 PEN D01 RAFTER • f I PY cxurItBang fteso osuza =Ei o m ;Eg .zzz r..,.-=,-- APPROVED BY 120113