Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
SITE PLAN - ROBERTSON ommi N1 . 1 w A e !?7 n O 0 %..., H 4 yJ 0 n n 3o d Z d r� ri) to vl n g W Q Y CD i ` o W AV , z,..0 21313W NOI13110021d M3N R r 2131213ANI 390321V10S 3JIA213S dWV OOZ -nn _ _ 21313W 39d .7YJ ENERGY Solutions PROJECT INFORMATION SOLAR OWNER: BUILDING APPLICABLE ROOF SPECS: SYSTEM INFO: CONTRACTOR. DATA: CODES: ENERGY SOLUTIONS LLC NICK ROBERTSON SINGLE FAMILY 2014 OREGON STRUCTURAL COMPOSITION SHINGLE ROOF (16)SOLARWORLD 280 WATT PO BOX 887 15063 SW KENTON DRIVE RESIDENTIAL INSTALLATION SPECIALTY W/2X8 RAFTER DOUGLAS FIR MONO BLACK MODULES BEAVERCREEK,OR 97004 TIGARD OR 97224 CODE #2 @ 24"ON CENTER (1)SOLAREDGE 3800 W/(16) 503.680.3718 503.701.8650 PRESCRIPTIVE. SPAN OF 10'6" P300 OPTIMIZERS CCB#202002 ROOF AREA=2116'SQ (1)ZIGBEE MONITORING TILT=35 DEGREES SYSTEM SIZE=4.48 KW AZ= 185 DEGREES SYSTEM AREA=291'SQ<25% PROJECT NOTES— PRESCRIPTIVE CODE I. 303.2-PV SYSTEMS AND SUPPORTING STRUCTURE SHALL 6. ...CONTINUED...SECTION IS LARGER THAN 150 FEET MEASURED 10. PER 305.4 ITEM 3-TOTAL SYSTEM WEIGHT SHOULD NOT COMPLY WITH REQUIREMENTS OF OSSC CHAPTER 6 OR THE IN LENGTH OR WIDTH.EXEMPTION IA:WHERE PV ARRAY DOES EXCEED 4.5 PSF.PV MODULES AND RACKING SHALL BE ORSC AS APPLICABLE NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF DIRECTLY ATTACHED TO ROOF FRAMING.ATTACHEMENTS 2. 303.3-ALL PV MODULES TO BE UL 1703 LIS rED AREA OF THE STRUCTURE,A MINIMUM OF 12"UNOBSTRUCTED SPACING WILL BE 48"ON CENTER MAX,WHEN ATTACHMENT IS 3. 303.5-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION THAT PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY LOCATED WITHIN 3'OF ROOF HIP,EDGE,EAVE,AND RIDGE IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY HORIZONTAL RIDGE. SHALL BE 24"ON CNETER MAX REQUIRED BY OSSC SECTION 1501.1 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD 11. MAX MODULE HEIGHT WILL NOT EXCEED 12"OFF ROOF 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE CONSTRUCTION WITH 2X4 TRUSSES AT 24"ON CENTER MAX SURFACE RATED FOR THEIR USE. EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS IN TABLE 12. SECTION 304.7-MECHANICAL EQUIPMENT CLEARANCES OF 30 5. 303.4-303.8-PV LAYOUT SHALL NOT RESTRICT EGRESS, 305.4.1 MINIMUM ON ROOF. LIGHT,VENTILATION,OR ROOF DRAINAGE 8. 304.9.5-DISCONNECTS,J-BOXES,COMBINER BOXES OR 6. 304.9.1 GERNERAL PATHWAYS REQUIREMENTS EXEMPTION 1: GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAYS ON STRUCTURE WITH A PV ARRAY AREA OF 1,000 SF OR LESS OR CUTOUTS INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12 9. ROOF MATERIAL IS COMPOSITION ROOF,IF METAL,FOLLOWS AND WITH AN INTERSECTING ADJACENT ROOF WHERE NO PRECRIPTIVE PATH IN 2010 OREGON SOLAR CODE z W H A Yce W f I IY Z I I ii>w W N H U W] in 0 0 us re n 0�3 o O W 34' ry of Z . 15063 SW Kent• 1.M� 3.1,12 o�dI: o i f0 0 0 . IIIF - I '�--- SL . 14,6., 0 0 0 0 • 0 • 0 0 0 0 • o l o • o t: i 13. ENERGY SOLUTIONS, LLC NICK ROBERTSON N PO BOX 887 15063 SW KENTON DRIVE BEAVERCREEK,OR 97004 TIGARD OR 97224 A ENERGY 503.680.3718 503.701.8650 w 4- E CCB#202002 4.48 KW SOLAR ARRAY-RESIDENTIAL Solutions r ENLARGED ROOF PLAN S Ni w 01r NJ 41 1'6" , , T f----r" PGE METER wl LID yI 200 AMP SERVICE 0 0 0 0 1 SOLAREDGE INVERTER _- I NEW PRODUCTION METER -o 112_2 j 0 0 o -- MI • • ' w -o-- --- V • A Gi System Information Labels PV Module Ratings Inverter Ratings Photovoltaic DC Disconnect Module Make SolarWorld Inverter Make SolarEdge Rated MPP Current = 12.8 A ENERGY Module Model SM 280M Black Inverter Model SE3800A-US Rated MPP Voltage = 350.0 V Max Power = 280 W Max. Output Power = 4150 W Max. System Voltage = 500.0 V Solutions Open Circuit Voltage = 39.5 V Max. DC Voltage = 500 V Max. System Current = 15.0 A Max Power Point Voltage = 31.2 V Norminal AC Voltage = 240 V Photovoltaic AC Disconnect P.O. Box 887 Short Circuit Current = 9.71 A Max. AC Current = 16 A AC Output Current = 16 A Beavercreek, Oregon 97004 Max Power Point Current = 9.07 A CEC Inverter Efficiency = 98.0% Nominal AC Voltage = 240 V Phone: 503-680-3718 UTILITY O © O O © SERVIC O© © \ -- INVERTER Main \ OCPD )200A Junction AC 16 modules w/ Box optimizers in series ——- - (at array) — __ M DC -. I ,-- 20A / \..,______/ / L --- Main ��i H ) G Service �/ Panel O O O _ 200A Bus O BUILDING GROUNDING ELECTRODE PV System meets requirements for Rapid Shutdown as defined in 690.12. EQUIPMENT SCHEDULE Notes: REF DESCRIPTION PN NOTES • Equipment, conductors and conduit 1 SOLAR PV MODULE SW 280 MONO SOLARWORLD 280W BLACK MONOCRY STA LLINE MODULE as listed or equivalent. 2 PV MODULE OPTIMIZER P300 SOLAREDGE300W IN MODULE OPTIMIZER • Expected nomimal string voltage: 3 ARRAY MOUNTING HARDWARE TBD PRO SOLAR FLUSH ROOF MOUNTING SYSTEM 350Vdc. 4 JUNCTION BOX TBD • Expected nominal optimizer voltage: 5 AC/DC INV ER[Lk SE3800A-US SOLA REDGE 3.8KW INVERTER W/AC/DC DISCONNECT 21.9Vdc 6 GENERATION METER TBD ONE-LINE STANDARD ELECTRICAL DIAGRAM 7 SOLAR OCPD TBD 20A. 240V, 2-POLE BACK-FED CIRCUIT BREAKER PROJECT REF: Robertson 8 SERVICE PANEL NA 200A BUS, 200A MAIN BREAKER, 240V(EXISTING) SITE ADDRESS: 15063 SW Kenton Dr,Tigard. OR CONDUIT&CONDUCTOR SCHEDULE 97224 REF DESCRIP./CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE SYSTEM SIZE 4.48kW A PV-WIRE&BARE GROUND #12/#6 2/ 1 1 String of 16 Modules/Optimizers(SW280/P300) B TIWN-2 #12/#6 2/1 EMT 3/4" Sheet 1 of 2 C BARE GROUND #6 1 Date: November 12, 2015 D THWN-2 #12 4 EMT 3/4" NOT TO SCALE AURORA STATE Elev. Hi h Tem _ Distance above roof Extreme OCPD& Disconnect(continued): ENERGY - , P Inverter OCPD and Disconnect: 0.4% 2% Avg. 0.5" ' 3.5" 12" Mill 16.0A x 125% =20.0A 4 20A, 240V, 2-Pole Back Fed Circuit Breaker Solutions 60 m 37 °C 32 °C 54 °C 49 °C 46 °C -5 °C AC disconnect not required for systems with 30A or lower main Solar AC Correction Temperatures OCPD per AHJ P.O. Box 887 ATc°id=-5°C-25°C =-30°C 11Th°t= (37°C + 35°C)-25°C =47°C Voltage Drop calculations: Beavercreek, Oregon 97004 Residential Roof mount PV Nominal String Voltage: 350Vdc Phone: 503-680-3718 Module Voltage Calculations PV MPPT String Current: 280W x 16_350V= 12.8A DC conductor run is 50 ft(estimated) SolarWorld Sunmodule Plus 280W Mono- Black Frame DC Voltage Drop Voc=39.5V Vmp =31.2V Voc Temp Coefficient=-0.31%/°C (2 x 50ft x 12.8A x 1.980/kft x 100)/(1000fUkft x 350V) =0.72% Isc=9.71A Imp=9.07A Pmax Temp Coefficient=-0.41%/°C Inverter Output is 240Vac, 16A Cold Voc=39.5V+ (39.5V x-0.31%/°C x-30°C) =39.5V+3.67V=43.2V AC conductor run is 15 ft(estimated) Hot Vmp=31.2V+ (31.2 x-0.41%/°C x 47°C) =31.2V-6.01V= 25.2V AC Voltage Drop (2 x 15ft x 16.0A x 1.980/kft x 100)/(1000ft/kft x 240V) =0.40% SolarEdge P300 Optimizer: Maximum Power per String: 5250W Max Input DC Power: 300W Max Input DC Voltage: 48V MPPT Operating Range: 8-48V Max Input lsc Current: 10A Maximum DC Output: 15A Min/Max Input String Length: 8/25 ,1 Notes: String Sizing • Interconnection to the main service via a back-fed circuit breaker in 16 x 280W=4480W the service panel complies with 705.12. • Conductor sizing listed is minimum required based on NEC SolarEdge SE3800A-US Inverter ampacity calculations. Minimum conductor size into Solar Meter Max DC Input(V): 500V Max DC Input(A): 13.0A Base typically required to be at least#6 AWG because of terminal Nominal DC Input: 350V sizing. Output voltage: 240Vac Max Output current: 16.0A • All electrical work must be made in accordance with the local and Label Calculations applicable National Electrical Code ANSI/NFPA 70. MPPT DC Current: • PV System to be installed and labeled per National Electric Code. 280W x 16+350V= 12.8A Specifically: -690.4(B)(1),(2) and (3) Conductor Ampacity -690.4(H) PV Source Circuit(Optimizer Output): -690.5 15A x 125% = 18.8A (continuous duty) -690.17 18.8A_ 1.00= 18.8A (PV Wire in free air) -690.31 #12 AWG (rated for 35A into 75°terminals in free air) -690.35(C)and (F) 18.8A_0.71 =21.1A (conditions of use-temp in conduit) Inverter listed to UL-1741 for grid-interactive use and GFDI #12 AWG (rated for 25A into 75°terminals in conduit) protection. • All equipment used UL listed. Inverter Output Circuit: 16.0A x 125% =20.0A ELECTRICAL CALCULATIONS #12 AWG (rated for 25A into 75°terminals and required OCPD) PROJECT REF: Robertson OCPD& Disconnects SITE ADDRESS: 15063 SW Kenton Dr,Tigard,OR DC fusing not required with a single string 97224 DC/AC Disconnect functions integral to inverter. SYSTEM SIZE:4.48kW 1 String of 16 Modules/Optimizers (SW280/P300) Sheet 2 of 2 Date: November 12, 2015 jiiiiii Sunmodule/ PI us SOLARWORLD SW 280 MONO BLACK REAL VALUE alliiiiWitiii .#,M Au v., 3 o� TUV Power controlled: _ 3 TUVRheinland 1 Lowest measuring tolerance in industry -`. 0000139.':' I j Every component is tested to meet ! I i I I { i 3 times IEC requirements f I l i I I Designed to withstand heavy accumulations of snow and ice I I ! i OSunmodule Plus: . Positive performance tolerance -0/r5 Wp O `�4 25 year linear performance warranty and 10-year product warranty WARRANTY O ,/ Glass with anti-reflective coating --„______ _______`` CpaEiN( World-class quality as�,,,EC E,,,, '�'+ •awea�a re'''''` Salety IeZ IW'S'1710 g+ teaW Fully-automated production lines and seamless monitoring of the process and mate- DVE •Periodic Inspection i •,:• •Padedie Inspection •0Eowg sand rwtant ? Pwer ControNed rial ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus-Sorting PFRfUR0.1.1 TESTf0 S A� SGSISA'MIST Rf515iM- Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules -7„T ir,^.�c C Us that have greater than or equal to the nameplate rated power. �/ �' UL 1703 2S-year linear performance guarantee and extension of product warranty to 10 years [ DVE Iso 14001SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ` ,„ Certified of 25 years, a significant added value compared to the two-phase warranties com- mon in the industry.In addition,SolarWorld is offering a product warranty,which hasOIL been extended to 10 years' Home Innovation AGES GREEN GUNNED- . In accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty MEIM MADE IN solarworld.com AND IMPOR EDOPARTS jiiiijj SunmoduleY Plus SOLARWORLD SW 280 MONO BLACK REAL VALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/m',NOCT,AM 1.5 Maximum power Pm„ 280 Wp Maximum power P,,,,, 207.2 Wp Open circuit voltage V,, 39.5 V Open circuit voltage Va 35.8 V Maximum power point voltage VmPp 31.2 V Maximum power point voltage V,,, 28.3 V Short circuit current I„ 9.71 A Short circuit current I,c 7.85 A Maximum power point current Impp 9.07 A Maximum power point current I,,,., 7.33 A Module efficiency '1,,, 16.7% Minor reduction in efficiency under partial load conditions at 25°C:at 200 W/m',100% (+/-2%)of the STC efficiency(1000 W/m')is achieved. 'STC:1000 W/m',25°C,AM 1.5 1)Measuring tolerance(It,,,)traceable to TUV Rheinland+/-2%(TUV Power Controlled). COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 Cell type Mono crystalline NOCT 48°C Cell dimensions 6.17 in x 6.17 in(156.75 x 156.75 mm) TC l„ 0.044%/°C TC,„„ 0 31 /°C Front Tempered glass(EN 12150) Frame Black anodized aluminum TCPmpp 0.43 /°C Weight 39.5 lbs(17.9 kg) Operating temperature -40°C to 85°C SYSTEM INTEGRATION PARAMETERS IX 1000 W/m' Maximum system voltage SC lI/NEC 1000 V Maximum reverse current 25 A 800 W/m' Number of bypass diodes 3 600 W m' Design Loads" Two rail system 113 psf downward Es.- / 64 psf upward Design Loads' Three rail system 170 psf downward 400 W/m' 71 psf upward _. _ Design Loads' Edge mounting 30 psf downward 200 W/m' 30 psf upward 1 100 W/m' 'Please refer to the Sunmodule installation instructions for the details associated with these load cases. Module vottage EAV. ADDITIONAL DATA Power sorting' -0 Wp/+5 Wp x 4 1., 37.44(951) J-Box I P65 Module leads PV wire per UL4703 with H4 connectors Module type(UL 1703) 1 11.33(288) Glass Low iron tempered with ARC 39.37(1000) 0.6(15.3 1 ) • VERSION 2.5 FRAME Version Compatible with both"Top Down" 2.5 frame and"Bottom"mounting methods 65.94(1675) —bottom • Jr Grounding Locations: mounting ,, r -4 corners of the frame L holes -4 locations along the length of the module in the extended flanges 1.34(34) 000 r o O o O O J-x4 1 t 4.20(107)t --RI ..-) (31) L - 39.41(1001) -I All units provided are imperial.SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-6026US 12-2014 v ) solar - SolarEdge olar - • • oc W SolarEd a Single Phase Inverters ~ 9 9 OC For North America W SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US ‘.0 a rter 2 � 5 vott aa1,a0\. A 7 • The best choice for SolarEdge enabled systems ▪ Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) — Small, lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless • — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us . . solar - • • Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US 5E30004-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A-US SE 114004-u5 1 OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA 10000 @240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 t l240V 10950 0240V AC Output Voltage Min:Nom:Max!1j - - 183-208-229 Vac _ AC Output Voltage Min.-Nom:Max!1j / / ✓ 5 211-240-264 Vac AC Frequency Min:Nom:Max.111 59.3-60-60.5(with HI country setting 57-60-60.5) Hz Max.Continuous Output Current 12.5 16 24 @ 208V 25 32 I 48 @ 208V 47.5 A 21 e 240V 42 t 240V GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC Power(STC) 4050 I 5100 I 6750 I 8100 I 10250 I 13500 I 15350 W Transformer-less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Current°1 9.5 13 15.5 @ 240V 18 I 23 I 30. 240V 34.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kua Sensitivity Maximum Inverter Efficiency 97.7 I 98.2 98.3 98.3 98 98 98 % CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97 5 97.5 97 @ 208V 97.5 % 98 l 240V 97.5 @ 240V Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI C12.1 Optional'' Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed141 STANDARD COMPLIANCE Safety UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards IEEE1547 Emissions ) FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/lb 6 AWG 3/4"minimum/1-2 strings/ AWG range 14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/ (HxWxD) 775 x 315 x 260 mm Weight with Safety Switch 51.2/23.2 1 54.7/24.7 88.4/40.1 lb/kg Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature Range -13 to+140/-25 to+60(-40 to+60 version available°) 'F/'C Protection Rating NEMA 3R "'For other regional settings please contact SolarEdge support. . i'I A higher current source may be used;the inverter will limit its input current to the values stated. 131 Revenue grade inverter P/N:SExxouA-US000NNR2(for 7600W inverter:SE7600A-US002NNR2). i"l Rapid shutdown kit P/N:SE1000-RSD-51. isl-40 version P/N:SExxxxA-US000NNU4(for 7600W inverter:5E7600A-US002NNU4). co :---liz RoHS ®SolarEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SniarFdee Terhnnloeies.Inc All other trademarks mentinnad heroin 0e trademarks of their respective owners.Date:12/2014.V.01.Subject to change without notice. I..L solar - • • w SolarEdge Power Optimizer _ Module Add-On For North America P300 / P320 / P400 / P405 CL CC w = O § rjve0 m wa�antY I PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us SolarEdge Power Optimizer solar. - • • Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 __ — (for 60-cell modules) (for high-power (for 72&96 cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Power") 300 I 320 400 405 W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10 Adc Maximum DC Input Current 12.5 13.75 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer -- STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters 128x152x27.5/ 128x152 x35/ 128x152x48/ Dimensions(W x L x H) mm/in 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 Weight(including cables) 770/1.7 930/2.05 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % ",Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations • mit is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE Eta 0 SolarEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice. Ez Mount L Foot for Shingle Roofs . , .„ 4 _ , . , .. • . � yFi, . . ....„.... .,,, . ,... . ..... ... ,• . . . . . .. 1. .. . , ..,:.,....„,,,..t..,_ , _ ....,..•.. . „... f Rs• ? k' •V 1 � s d• - - •+•....ark. '�,.. .`- .. . • .:`~• �t • ' • { . • r* `F� • x r * ► .`. .,. r• . U r. - "4 p • t ne .' 5..` • - 1 - . 1 ti • .'. •4 A� . • _ The Next Generation in Flashed Mounts for Shingle Roofs! 1905 E 5th St., Ste. A Vancouver, WA 98661 Phone: 360-844-0048 www.sunmodo com EZ Roof Illount . . . Engineered and Designed for easy installation. Our roof mounting system is water tight and durable for any composite/shake roof! k ti• *. e r Serrated L Foot allows for Versatile aluminum base for Flashing designed to redirect rail mounting on either multiple configurations. water flow. side. Ez Mount L-Foot Kit for Shingle Roofs Kit# K10068-001 All kits come complete with the following parts: 1-Lag Bolt 55 5;'16 x 4 k a/ 1-AI Shoe , Parti 815015002 i Parti A20065-0O1 1 1-Ez L Foot Part*A20064-001 ,440143111000, p hing 1 Hex Cap � 1-Bolt 3/8-16 x 3/4" Parti A20052-001 Parti A20066001 1-Flange Nut 3/8' Also available: ,:,r "%I. ' - '' fi 4. 1905 E 5th St . Ste A Vancouver. WA 98661 Phone: 360-544-0048 www.sunmodo-com 2 x 8 \ 7y NEW SOLAR PV ARRAY AND G- ATTACHMENT O EXISTING ROOF STRUCTURE 8 2x4 Collar Tie 2 x 8 N\N"NN 18' 1/2"THICK LAP BOARDS W/SHEETING ABOVE LOAD BEARING WALL Robertson 35° Roof Pitch Scale: NTS • COLLECTOR MODULE isisiti CONTINUOUS SUPPORT ''• RAIL AND CONNECTION .,�' POST BY RAIL. MANUFACTURER ' " ., ,., ' SUNMODO EZ ROOF MOUNT AND FLASHING ' WITH 2" STANDOFF POST AND L FEET WITH S/16" x ._' 1 3" STAINLESS LAG BOLT. INSTALL PER . MANUFACTURER'S INSTALLATION INSTRUCTIONS 3 . CONNECTION DETAIL Scale : NTS City of Tigard .11111 Building Division RECEIVE 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 N n v 2 5 2 015 www.tigard-or.gov OF I IGAKD !til:iliN(� 0 ISlO 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: t SorD3 City: i l Zip: Owner's Name: J R-olaa4so, Date: , , Z y 1 ,S Contractor's Name: Erve.r, Cu 1J-1- car S CCB #: -Zo ZOO 2_ Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? No OSSC or ORSC for design requirements. Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes'', qualifies for family townhomes Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If`"Yes", qualifies for Yes the prescriptive path. above ❑ No 1:/Building/Forms/PhotoVoltaic-Checklist.docx Is the construction material wood and does Yes Type of the construction qualify If"Yes", qualifies for ConstructionElNo the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. s If"Yes"; qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight 1 .4 Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? n Metal Single layer If roofing material is Roofing Check the type of of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑ of composition shingle. Is the roof mounted Yes Connections of solar assembly7( the solar assembly connected to roof If``Yes", qualifies for _ n No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? n No the prescriptive path. 115 lbs for 60 inch spacing or less? n Yes If"Yes", qualifies for the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches A k\ spacing or less? If"Yes", qualifies for n Yes the prescriptive path. El No achment of roof mounted If the spacing falls Spacing of Minimum 24 inches within 24 inches and 60 solar systems p g clamps? directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metalanels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. n No Is the roof decking of WSP min. '/2"thickness, n Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. n No 3 I:/Building/Fonns/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: c o Lr W0( Model Number: S‘A) 780 b k L AQP 0 Listing Agency: 4 I:/Building/Forms/Photovoltaic-Checklist.docx