Plans ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES • A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A rt,pr � AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. L L % - CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING NOV 1 9 2015 DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. CITY OF TIGARD CiTY B - �F rIG�Rfl (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING UIDI JG EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, REVI1t✓WJ�D FOR C E COMPLIANCE ®1vIoION FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE Approved: [ GALV GALVANIZED HAZARDS PER ART. 690.17. OTC; [ ] GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE i GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY Permit#: ��A6 `l .J HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Address: �'� D - i, i Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Suite •• Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BY: /k1111Date: I (f ..041'itzl kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR �10.' kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY OFFICE COPY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT C -- 3R NEMA 3R, RAINTIGHT J ,s I , ,1 - x w�E _ PV1 COVER SHEET ` .... a«••-'t,„.•.,....,- -_ -I ,.,: ,.,, _ , , _ PV2 SITE PLAN ii - PV3 STRUCTURAL VIEWS 4 '- '. 1 PV4 UPLIFT CALCULATIONS LICENSE GENERAL L NOTES �. '* PV5 THREE LINE DIAGRAM OR 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC =# , Cutsheets Attached # AND 2012 IBC. ', � "�- ,� , RGC, CGC1 -- l` rrnetfielo ApartmenIS- . ,r� 2. ALL ELECTRICAL WORK SHALL COMPLY WITH . -. _ - ; THE CURRENT NATIONAL ELECTRIC CODE AS ,; �w' , ....:-?:it; = ..� A- „..,,e44 : d• arc i t I 1' ".- ' •e. a• ,i4 1.41-^ AMENDED BY THE OREGON ELECTRICAL SPECIALTY 't- �" CODE. .�`'. 1� � ti.. � MODULE GROUNDING METHOD: ZEP SOLARillb ` s Y' `i '5 v ' j � r� t - , REV BY DATE COMMENTS AHJ: Tigard » , e -' r ' r .`�+r �" - - rt,pmem DATE COMMENTS t.,,,,,:., UTILITY: Portland General Electric 1_ . - etrd--Portland' rye Qr!, , tiate $cf re.gor U S: Geological.Surve i mini * - CONFIDENTIAL — THE INFORMATIN JB-9723079 JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE 9723079 �� MIKELS, GEORGE MIKELS RESIDENCE Dave Williamson ���f, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �••' SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15705 SW HIGHLAND CT 5.72 KW PV ARRAY ►I� • ORGANIZATION PART TO E EXCEPTRS IOUTSIDN CONNECTIE NE ON WITH MODULESPIENTS TIGARD, OR 97224 Way y W THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ APN: * PAGE NAME: SHEET: REV: DATE: S 3055 an Mateo CleCle CA 9a 02 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)636-1028 f:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB ; PVI-4.2-OUTD-S-US-Z-A (971) 317-1983 COVER SHEET PV 1 11/10/2015 (B88)—SOL—CITY(765-2489)www.solarcity.com PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH: 187 ARRAY AZIMUTH: 187 MATERIAL: Comp Shingle STORY: 1 Story Front Of House LEGEND 0 (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS v � I _1 DC DISCONNECT & WARNING LABELS -o 0 Ac AC DISCONNECT & WARNING LABELS _ _ _ D' _ (E) DRIVEWAY = O DC JUNCTION/COMBINER BOX & LABELS - - - -a- - - - � a�7MP1 — f/ 0 0 0 Q o o c i _ i - cn Ln 0 DISTRIBUTION PANEL & LABELS 0 C oc C• J ti • 0, C if) O ❑' LG LOAD CENTER & WARNING LABELS • M DEDICATED PV SYSTEM METER 0 c - e c o -a c v 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR • CONDUIT RUN ON INTERIOR AC A CI F_ I © GATE/FENCE —I Q HEAT PRODUCING VENTS ARE RED KM ) 1( '" INTERIOR EQUIPMENT IS DASHED L. L:�J " - SITE PLAN N TOTAL ARRAY AREA (SF): 399 TOTAL ROOF AREA (SF): 2342 Scale: 1/8" = 1' W `) E TOTAL ARRAY AREA IS a 17.03 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA 1077 "///'_""_____'z S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED THE JB-9723O79 0 0 ��,t MIKELS, GEORGE MIKELS RESIDENCE Dave Williamson SOlC�f Cit�/ BENEFITAIOF ANYONE EXCEPT SOLARCITYDFOR INC., MOUNTING SYSTEM: NNOR ORTSHOALL IT BE OTHERS DISCLOSED IN E RWHOLENTSE OR IN Comp Mount Type C 15705 SW HIGHLAND CT 5.72 KW PV ARRAY Pig ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 '` THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ 3055 Clearview WayPAGE NAME: SHEET: RE SOLARCITY San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2-OUTD-S-US-Z-A (971) 317-1983 SITE PLAN PV 2 11/10/2015 (888)—SOL—CITY(765-2489)www.sdarcity.com (E) 2x4 PV MODULE Si /\ 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS /\ LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT PRE-MANUFACTURED TRUSS HOLE. — ZEP ARRAY SKIRT (6) t STRUCTURE MEETS THE • (4) (2) SEAL PILOT HOLE WITH 2'-2" 6'-9" / 5'-1" / PRESCRIPTIVE REQUIREMENTS ZEP COMP MOUNT C _ POLYURETHANE SEALANT. OF THE OSSC SECTION 3111 it�!`�]��� -'A WW- i ' - _ 61144-7. 11141 (E) LBW — ZEP FLASHING C `if gm — (� INSERT FLASHING. - (E) COMP. SHINGLE �� VommmalTii JM ' SIDE VIEW OF MP1 NTS (\) PLACE MOUNT. A -" (E) ROOF DECKING XL MI5/16" DIA STAINLESS (5) MEM (5) INSTALL LAG BOLT WITH SEALING WASHER. MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH LANDSCAPE 72" 24" STAGGERED WITH SEALING WASHER (6) BOLT & WASHERS. PORTRAIT 48" 20" (2-1/2" EMBED, MIN) TOP CHORD 2x4 @ 24 OC ROOF AZI 187 PITCH 22 STORIES: 1 (E) RAFTER STAN DOFF ARRAY AZI 187 PITCH 22 6, BOT CHORD 2x4 @24" OC Comp Shingle Scale: 1 1/2" = 1' •J CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-9723079 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MIKELS, GEORGE MIKELS RESIDENCE Dave Williamson .. �'`, BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 15705 SW HIGHLAND CT 5.72 KW PV ARRAY il' PART TO OTHERS OUTSIDE THE RECIPIENTS MODULEP TIGARD, OR 97224 3055 Cleor,ew Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV. DATE San Mateo,CA 94402 INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2-OUTD-S-US-Z-A (971) 317-1983 STRUCTURAL VIEWS PV 3 11/10/2015 (888)—SOL—CITY(765-2489)www.soIarcity.com UPLIFT CALCULATIONS 11.10.2015 ,,,'\‘,44P1/ system Structural Version#53.4 a Tk &1.)I a 1 C I t I Y 0 Desi a n Software Project Information&Table Of Contents Risk Category: H • PV System Type SolarCity SleekMount'" • Comp Roof Comp Roof Layers of Comp Roofing .2 Roof Slope 22° Rafter Spadng 24"O:C. PV System Module Orientation Landscape and Portrait PV Module Area 391 sf PV Module Width 39" PV_Module Length _ 66" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads_ Ground Snow_ Load pg 25.0 psf ' ASCE Table 7-1 Surrounding Roof Snow 100%. 25.0 psf 'ASCE Eq:7.471 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design CodeASCE 7-05 ' Wind DesigMethod Pa nrtially/Fully Enclosed'Metho_d • Basic Wind Speed V 95 mph Fig.671 Exposure Category C . ' ,Section-6.5,6.3, Roof Style Gable Roof 'Fig.6-118/c/o-14A/B Mean Roof Height__ h _ _ _ _15 ft. __ _ _ 5ection_6.2, Effective Wind Area(1 Module) A 17.8 sf IBC 1509.7.1 Wind Pressure.Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 6-3 Topographic Factor . Kit: 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Irriportance:Fador I 1. 0: Table.6- 1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(VA2)(I) Equation 6-15 16.7 psf Ext.Pressure Coefficient(tip) GCp(Up) -0.88 Fig.6-118/CID-14A/B Ext.Pressure Coefficient(Down) GCp(Down) 0.45 Fig:6-118/G/D-14A/B Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure Up, . ;p(up) -14.6,psf Wind Pressure Down p(down) 10.0 psf Allowable Standoff Spacings X-Direction V-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable'Cantilever. Landscape. 24" __ _ . NA. , Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf NetWind Win at Standoff , - T-actual -252 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 50.4% Max Allowable Standoff Spacing Portrait 48" 66" Max_Allowable Cantilever Portrait_ 20" NA. Standoff Configuration Portrait Staggered ,.j Max Standoff Tributary_Area Trib 4.0' PV Assembly Dead Load _ W-PV. 3 psf Net Wind Uplift_at Standoff T-actual -282 lbs Uplift Capacity_of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 56:5% CONJ B-9723079 0 0 PREMISE OWNER: N: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: \\�‘ w CONTAINED SHALL NOT BE USED FOR THE MIKELS, GEORGE MIKELS RESIDENCE Dave Williamson --;;;C I Ci+ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: °.�r' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 15705 SW HIGHLAND CT 5.72 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 le 3055 Cleardew Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ PAGE NAME: SHEET: REV. DATE sem,5ale 9402 a SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2-OUTD-S-US-Z-A (971) 317-1983 UPLIFT CALCULATIONS PV 4 11/10/2015 (888)—SOL—CITY(765-2489)www.eolarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:NoMatch Inv 1: DC Ungrounded INV 1 —(1)ABB # PVI-4.2—OUTD—S—US—Z—A LABEL: A —(22)REC # REC260PEZ OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24550139 FCI Inverter; Zigbee 4200W, 240V, 96% PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E 125A MAIN SERVICE PANEL E3 125A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! A (E) WIRINGCOOPER CUTLER—HAMMER � Inverter 1 IND 1 125A/2P Meter Socket Disconnect `'J ABB /\ DC+ Vstart = 200V rill • PVI-4.2—OUTD—S—US—Z—A DC- 1y MP 1: 1x11 • (E) LOADS A B __ EGC / J • �1 n n �, NOVr Z _ I ~�— L2 DG+ • N , ,DG I /GC-C VStart = ZOOV m 25A/2P _ \— GND r�'—— ——— GND _ EGCI DC+ G��A ��l— GEC N DC- MP 1: 1x11 • • 6 I Il GND I----EGC- - �- ���__LLL JJJ,��' I (1)Conduit Kit; 3/4' EMT N • J - - EGCIGEC - Z-Z C.7 GEC r Y TO 120/240V I I SINGLE PHASE I I UTILITY SERVII CE ICE I I I I I I I I I I I I J—__L_ Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER—HAMMER #BR225 PV BACKFEED BREAKER A (1)COOPER #B—Line Meter Socket 011 Breaker, 25A 2P, 2 Spaces Meter Socket; 125A, 4-14AWG, Ring Type AC DC —(2)Gro n,d xRoil Copper — 1)AW CAP; B—Line Meter Socket Accessory °pp —(1)Milbank CL200D /Itron C1S —(1)CUTLER—HAMM R #BQC2252115 Solid— ate Single—Phase Meter; Digital Breaker; 15A/1P-25A/2P-15A/1P, 2 Spaces, Quadplex B (1)CUTLER-HAMMER #DG221URB Disconnect; 30A, 240Vac, Non—Fusible, NEMA 3R —(1)CUTLER—HAMMER N DGO3ONB Ground/Neutral Kit; 30A, General Duty(DC) O —(1)AWG#10, THWN-2, Block I (2)AWG #10, PV Wire, 600V, Block Voc* =458.46 VDC Isc =9.01 ADC -j—(1)AWG#10, THWN-2, Red O l �-(1)AWG #6, Stranded Bare Copper EGC Vmp =337.7 VDC Imp=8.5 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 MC 6 (1)Conduit Kit; 3/4' EMT . . . . . . ,-(1)AWG#8,.TH.WN-2. Green ..EGC/GEC. (1)Conduit Kit; 3/4'.EMT. . _ . , . . . . . (2)AWG #10,PV Wire, 600V, Block Voc* =458.46 VDC Isc =9.01 ADC ,I. O ca—(1)AWG #6, Stranded Bore Copper EGC Vmp =337.7 VDC Imp=8.5 ADC (1)Conduit Kit; 3/4' EMT JB-9723079 0 O PREMISE OWNER: DESCRIPTION: DESIGN: \\,} CONFIDENTIALEDA THE INFORMATION USED HEREIN JOB NUMBER: ..-9 SolarCity BENEFITO SHALL E E CE TSO FOR THEMIKELS GEORGE MIKELS RESIDENCE Dave WilliamsonBENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 15705 SW HIGHLAND CT 5.72 KW PV ARRAY PART TOIZ TON, S ODEIN TOE RECIPIENTS MODULE: OR 97224 3055 Cleorvew Way ORGANIZATION, EXCEPT IN CONNECTION WITH TIGARD, THE SALE AND USE OF THE RESPECTIVE (22) REC # REC260PEZ PAGE NAME SHEET: REV: DAIS San Mateo. eCAe 94402Wy SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2—OUTD—S—US—Z—A (971) 317-1983 THREE LINE DIAGRAM PV 5 11/10/2015 (888)—SOL—CITY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) (P01) Per Code: OPERATING CURRENT Per Code: WARNING Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 INVERTER OUTPUT NEC 690.64.6.7 OPERATING VOLTAGE CONNECTION Label Location: DO NOT RELOCATE PHOTOVOLTAIC DC (DC)(INV) THIS OVERCURRENT DISCONNECT Per Code: NEC 690.14.C.2 I- '‘ - Label Location: IN�I NL7 (AC) (P01) ELECTRIC SHOCK,*v, 4. Per Code: Label Location: UCR NEC 690.17(4) WARNING (DC) (INV) Label Location: ( . NOT T® �H TERM..0.1 I -_ MAXIMUM POWER- (DC) INV TERMINALSON BOTH LINE'AND Per Code: POINT CURRENT(Imp) Per) ( ) LOAD SI©E5 MAY BE ENERGIZED ELECTRIC SHOCK HAZARD NEC 690.35 F Per Code: IN THE'©PEN POSITION THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER- V NEC 690.53 44 - PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINTVOLTAGE(Vmp) �' UNGROUNDED AND INVERTER IS MAXIMUM SYSTEMMAY BE ENERGIZED VOLTAGE(Voc) V UNGROUNDED SHORT-CIRCUIT (ISc) A Label Location: CURRENT(Isc) PV SYSTEM (AC) DISCONNECT FOR UTILITY OPERATION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING'. ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 DC VOLTAGE IS HAZARD.DO NOT TOUCH ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE AC Label Location: OPERATINGMAXIURRENT _ A • WARNING (DC) (INV) MAXIMUM AC _ Per Code: OPERATING VOLTAGE V ELECTRIC SHOCK HAZARD IFA GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: CAUTION (P01) 1 DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 Label Location: PHOTOVOLTAIC SYSTEM (AC):AC Disconnect • ,PHOTOVOLTAIC AC (AC) (P01) _F (C): Conduit DISCONNECT Per Code: (CB): Combiner Box NEC 690.14.C.2 Label Location: (D): Distribution Panel (DC): DC Disconnect CAUTION (D) (P01) (IC): Interior Run Conduit Per Code: g PHOTOVOLTAIC SYSTEM NEC 690.64.6.4 (INV): Inverter With Integrated DC Disconnect CIRCUIT IS BACKFED (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR o0,e4v 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ••• = ■ San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set s�►�� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I f f I� , (888)-SOL-CITY(765-2489)www.solarcrty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o LV-' ZS Comp Edge Zone Calculations 1 of 4INt ZS Comp Edge Zone Calculations 2 of 4 Zep S o la r 3/26/15 p So to r 3/26/15 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing - module width x design load Y I checked. Wind Down Calculations • All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 120 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads design load 15.35 27.64 27.64 psf Load Duration Wind Snow . RC, SV, g landscape Uplift= 656 lbs N/A- .SC'"`"%' A design load portrait= 12.28 27.64 `27.64 psf Lateral= 357 lbs 290 lbs c 85818 �ji note:use 10 psf minimum Down Force= 1074 lbs 771 lbsSnow Calculations 7.) OREGON 0 �.4.,,.4.,, 10' l"�n 4.. To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and lower. q cs Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes above 30 Attachment Spacing Calculations 0,fy Roo degrees. Uplift Spacing EXPIRES: 12/31/15 Allowable Uplift Load FOR PAGES 1-4 uplift spacing = Ground Snow Load= 30 psf module length or width x design load Roof Pitch 14 30 Wind Uplift Calculations 2014 OSSC and ASCE 7-10 Method 2 Design Snow Load 29.11 25.98 psf p=qh GCN (snow load spread over the length of the rafter) qh=0.00256 KZ KZt Kd V2 I Down Force Load Roof Pitch Basic Wind Speed= 120 mph Combinations: 14 30 Exposure= C Roof Zone= Edge Zone D+S= 31.16 25.10 psf Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+0.6*W= 12.91 19.18 psf . Gable/Hip Roof Kit= 1.0 per 6.5.7.2 D+0.75*0.6*W+0.75S31.59 31.91 psf Vorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 Roof Height= 30 GCN landscape= -1.6 Allowable Spacing for Down Force lscape effective area= 13.0 ft2 GCN portrait= -1.5 771lbs in portrait effective area= 21.7 ft2 landscape down force spacing = 39"x 31.91psf x 144 ft2 =89" Plandscape= -49.13 psf qh= 30.71 psf Pportrait= -46.06 psf 7711bs in portrait down force spacing = 65"x 31.91psf x 144 ft2 = 53" Uplift Load Combination:0.6D+0.6W(ASCE Section 2.4.1 equation 7) design load landscape= -27.73 psf design load portrait= -25.89 psf landscape uplift spacing = 39 6 x26 lbs psf f x 144 in = 87" 656 lbs in portrait uplift spacing = 65"x 25.89 psf x 144 ft2 =56" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 3/26/15 3/26/15 ZepSolar ZepSolar Lateral Spacing Module Deflection Spacing • The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -0.8182 x Maximum Uplift or Down Force Pressure+79.909 Allowable Lateral Load Maximum Uplift Pressure Landscape= -27.73 lateral spacing = module width x design load Maximum Uplift Pressure Portrait= -25.89 Snow Calculations Maximum Down Force Pressure= 31.91 psf Ground Snow Load= 30 psf Ps=Cs pf Roof Pitch= 31 45 degrees landscape module spacing = -1.4545 x 31.91 psf+ 120.7273 =74" pf=0.7 Ce Cf I Pg Ce= 0.9 C,= 0.71 0.45 Cf= 1.2 pf= 22.68 22.7 psf portrait module spacing = -0.8182 x 31.91 psf+79.909 = 54" I= 1.0 Ps= 16.1 10.2 psf Calculation Summary Roof Pitch Calculated Edge Zone Spacing 27 30 31 45 Spacing Check Landscape Portrait Design Snow Load 26.73 25.98 13.80 7.22 psf Uplift 87" 56" (snow load spread over the length of the rafter) Down Force 89" 53" Lateral 30° 27° 30° Lateral Force Component 74" 48" 44" Down Force Load Roof Pitch Module Deflection 74" 54" Combinations: 27 30 31 45 D+S= 13.50 14.49 8.65 7.22 psf As can be seen in the table above,for Design Wind Speeds up to 120 mph and Ground Snow Loads up to 30 D+0.75*0.6W+0.755 10.46 11.24 6.88 5.95 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"on Allowable Spacing for Lateral Force center for most roof pitches.For roof pitches that are greater than 27 but less than 31°,the maximum 30 degree roof pitch attachment spacing is 44". 2901bs in landscape lateral spacing = 39"x 14.49 psf x 144 ft2 = 74" 2901bs in portrait lateral spacing = 65"x 14.49 psf x 144 ft2 =44" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2901bs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" . "",r•SOiarCity Zep Solar Next-Level PV Mounting Technology 4 SOiarCity Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs,, , ._ R ": � `• al. • . „ .... ..., , �.„Up roof �-, Interlock Ground Zen ,s. - I (Yv see,,,,,v,_� _—_,.— - Leveller Foot l' / . �-"":` * 'abs, ire ,....:. _ _.„„ , . I Zep compatible w Modmc - I Zep Groove 1 Roof Attachments r Array Skirt II - i '.T.8 4Le.:,1.,.:: :le!' Description �11 PV mountin solution for com osition shin le roofs ': \ � �i//"9 p 9 �� i o I, i% COpppt�0 • Works with all Zep Compatible Modules ,� q S%• t .p� f� • Auto bonding UL-listed hardware creates structual and electrical bond �� lre • Zep System has a UL 1703 Class"A"Fire Rating when installed using (21 LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Comp Mount Interlock Leveling Foot Part No.850-1382 Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 (TO • Designed for pitched roofs • Installs in portrait and landscape orientations tor.., ialri • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 'Skit . • Wind tunnel report to ASCE 7-05 and 7-10 standards cl � +w • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 [:\I` • Zep System bonding products are UL listed to UL 2703 It J, w i • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 `` Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps'zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 Solar inverters Additional highlights: • - RS-485 communication interface ABB string inverters (for connection to laptop or data logger). PVI-3.O/3.6/3.8/4.2-TL-OUTD - Integrated Arc Fault Detection and ,,,r, ( i t Interruption(-A Version). 's-7Mg. ...'�""^^,f 3.0kW to 4.2kW i� .'r , ,; {i • 1401 (I Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US ADD Mechanical specifications . _ '• 1 Nominal output power 3000W 3600W 3W0 F3800W 4200W es; Maximum output power wattage 3000 ii 13300' . 3300' 3600 i4o00i",14000' i 3300 42001 i 42b0' 4200 i 4600' 46b0' -, W W W W W W W W W ' Wi W Rated grid AC voltage ; 208V 240V : 277V ` 208V 240V j 277V 208V' 240V 277V 208V ; 240V 277V Input side(DC) Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax)....._ ........ ........... ... .... ...600V .. .. ....... ................. ...... .... Start-up voltage(Vstart) 200V(ad..120-350V) Full power MPPT voltage range 160-530V 120-530V .140-530V 140-530V "..,.- _ .� N Operating MPPT voltage range _.... .............. .... ... ............ ..... ... 0.7 x Vstart-580V(>=90V)... ........... ........... .......... ...................... 0 Maximum current(Idcmax)for both MPPT i n ,parallel 20A 32A 32A 32A ... l . . ... ............... .. ......... ............ ............._�........... _.........._.. .. . ............. ........... ............. ........................ Maximum ussabableecurrent per channel 10A 16A 16A 16A n Maximum short circuit current limit per ' 12.5A 20.OA 20.OA 20.OA channel ............... ...... ,.f Number of wire landing terminals per channel 2 pairs . son„na aa«* Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output side(AC) <r i Grid connection type 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 2W i 0/3W 2W............2W.,., 0/3W : .2W ' 2W i 0/3W: 2W " 2W 1 0/3W i 2W ' -C , j Adjustable voltage range(Vmin-Vmax)(V)..... 183- , 211 - • 244- 183- . 211- 244- , 183- - 211- 244- 183- 1211- - 244- ..� -...�* . 228V 264V 304V: 228V . 264V 304V 228V 264V 304V 228V I 264V 304V . Grid frequency 60Hz Adjustable grid frequency range 57-60 5Hz Maximum current(li,°,,e;„) 14.51 14.5 12.0 i 17.216.0 i 16.0 16.0 16 0 16 0 i 20.0 20.0 20.0 .... .A„ras.... AR.. AN......._A.rws iAMA, P.`ems.......Aeras.......AI..-t....A„c . Aeras... Power factor >0.995 Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved - Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high - Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of the property. a consistent and stable performance - The high speed and precise MPPT Anti--standing protection Meets UL 1741/IEEE1547 requirements Over-voltage protection Type Varistor,2(L,-Lz/L,-G across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A,WS_20A,ss 15A. 25A„ti,„ 20A„rays 20A,,,,S:20A„ras 20A,sG”20A„us 25A,,,,G 25A„A,, 25A„ras This inverter offers a dual input output power range. tracking and improved energy Efficiency Maximum efficiency ?..,...__...........,.96:9% 97% s7/......... .._._.... 97% section that processes two strings The transformerless operation gives the harvesting. . ...................................... CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure Operating performance . Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W„„, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <aw • Communication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1 xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range ? -13°F to+140°F with derating above 122°F(50°C) example:East and West) unit able to withstand the harshest Ambient air storage temperature range -40°F to+176°F(40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A ®1m Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. i Capability enabled at nominal AC voltage and with sufficient DC power available Power and productivity for a better world"" P%1110 NIP 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD • I itikk4411‘;‘'. ilkhiHilk:::' .. ENERGIZING LIFE TOGETHER ® REC. l EL PEAK ENERGY ',77L.1I\`'K SERFS ' 6S SS SO; _ 48 39 D_ tojoo I� EFFICIENCY HIGH PERFORMANCEL. — _---- i ' SOLAR A A'c c � I� YEAR PRODUCT WARRANTY PANELS ! YEAR LINEAR POWER 25 1 OUTPUT WARRANTY REC PEAK . . ,. . • ri out}, US IMPORT DUTY FREE ! $7.�a FENERGY _4t :, j. t_....../r TEMPERATURE RATINGS (1 (I yi Nominal Operating Cell Temperature(NOCT) 45,7°C(42°C) /1 [ J_ U V1JII � LlL �_ J TemperatureCoefficientofPM 0.40%/°C i. tv, TemperatureCoefficientofVoc -0.27961°C t� TemperatureCoefficientofisc 0.024%/°C 1111‘ REC Peak Energy Z-Link Series solar All measurements in Inches Panels are the perfect choice for building ELECTRICAL DATA@STC REC260PEZ GENERAL DATA solar systems that combine long lasting 1 Nominal Power-P,,,,,,,(Wp) 260 Cell Type: 60 REC PEmult crystalline Watt Class Sorting-(Wp) /_5 3 strings of 20 cells with bypass diodes Product quality with reliable poweroutput. • Glass: 0.125i11solarglasswith anti-reflection REC combines high quality design and NommalPower Voltage-Va,,(V) 30.7 surface treatment Nominal Power Current-I,,,,,,(A) 65D Back Sheet: Double layer highly resistant polyester 1 manufacturingstandards to produce high- • p g oc( ) Frame: Anodized aluminum(black) g Open Voltage- V 37.8 performance solar • z Short Circuit Current-Isc(A) 9.01 ZepGroove compatible uncompromising quality. .. Panel Efficiency(%) 15.8 Junction Box: IP67rated 0.156 in(1J_AWG)solar cable,2 x 4724 in The elecb¢al charecterotiu me wuhm./IU%of the mdocetedvelues ofl,,V,and P,;„alstandard Test Gondbons(STC) vawes at standard test cons t ons STC le..nass AM I s,r ed once 1000 W tt'cell tetepeian e 77°F(zs°cl) Connectors: H4 Amphenol �j ti ( ����� QGO�P�ITje� % At low r ad eero of 200 wAn>(AM l s&ren temperature 77 F lzs°cll at leant 97%of the STC panel efficiencywal he achieved Origin: Made in Singapore ''' • j • I ELECTRICAL DATA @ NOCT REC260PEZ MAXIMUM RATINGS \''` �. - TSA - Nominal Power-PM,,,,(Wp) 197 Operational Temperature: -40...+185°F(-40.:)+85°C) \'"y ,i COMPp'(�� Nominal Power Voltage-V,w,,,(V) 29.0 Maximum System Voltage: 1000VUL ._ . • l Nominal Power Current-l0,,,(A) 6.81 Design Load: SOlbs/ftz(2400Pa)long side 35 7 301bs/ft (1436 Pa)short side Open Circuit Voltage-Virc(V) MORE POWER COMPATIBLE WITH � PEBFT2 ZEP GROOVE FRAME Short Circuit Current-Isc(A) 724 Max Series Fuse Rating: 15 A Nominal operating cote peramenoer(euuw/m',AMLS.wlndspeedf a/s.enLemtemper atm er F(zu°q Max Reverse Current: 15A � �G>. \ - CERTIFICATION WARRANTY MECHANICAL DATA �'F'cF � • - 10 year product warranty. Dimensions: 65.55 x 39.02x 1.57 in(1665 x 991 x40mm) �� ✓� CO us 25 year linear power output warranty Area: 17.75fta(1.65mu) US IMPORT EASY TO > LISTED 1703 (max.degresslon in performance of 0.7%p a). DUTYFREE INSTALL { .i Weight: 431bs(19.Skg) UL 1703,Fire rating Type I.Class C - fr Note! Allgivenspecificationsaresubjecttochange ` f r f without notice at any time. JE • J a - :f REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing REC • products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker.RECSOL) Our 1,600 'r / ,- i?`;-, . , .,./ f ^`�1 >f��f,! •6' .y , p employees worldwide generated revenues of USD 647 million in 2013. .'�/ %,,,,V,,'?? >'.., ? >< ''' www.recgroup.com l r Ir e �{ > .�� � / � f�'f� °`/Vi`''i,j, �•>� � • �