PFI2015-00156 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12015-00156
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 11/25/2015
Parcel: SEG1145
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: Adjacent to SW Ash Avenue&SW Burnham Street. Relocate primary&streetlight facilities(Ash
Avenue Apartments-Relocate prim &STLT secondary for new building)
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
TSAHAI ANDERSON
10800 SW AVERY ST
TUALATIN, OR 97062
PHONE: 503-612-6106
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Not Present
Signature:
Issued By: �
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12015-00156
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced, with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08- TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard OCT 2 6 2015
PUBLIC WORKS — ENGINEERING PGE WORK ORDER# M185M*¢OF TIGARD
PLANNING/ENGINEERING
Public Facility Improvement (PFI) Permit
DESCRIPTION OF WORK(in the right-of-way) REQUIRED SUBMITTAL
Check one: 8 Utilities ❑ Sidewalk/driveway approach ❑ Street improvements ELEMENTS
rY 9
Detailed description:
Relocate Prima & Streetlight facilities M %linorwork in right-of-way
(sidewalk repair,curb cut,street
(Ash Avenue Apts- Relocate Prim & STLT Secondary for new Bldg) opening,etc.)requires:
•Application form,completed
and signed
•Submit one(1)copy of scaled sketch
Property address/location(s): Sw Ash & SW Burnham, Tigard of the proposed work to be done
•Submit one(1)copy of traffic
control plan
—OR—
Applicant's name: Tsahai Anderson E] Substantial project work requires
PP above items and professional
Address: 10800 SW Avery Street engineered plans for:
Tualatin, OR 97062 •Street widening
Cit;/state: Lip: •Subdivision infrastructure
Phone: 503-612-6106 Email: T&DsupportAvery@pgn.com •Main utility line extension:
- Storm Drain,Sanitary—Tigard
- Water—Tigard Water Service
Contractor's name: TBD after Bid Area(includes Durham,King City
CCB#: Expiration: and a portion of unincorporated
Washington County)
Address:
City/state: zip: DELIVER APPLICATION TO:
City of Tigard
Phone: Email: Planning/Engineering
13125 SW Hall Blvd.
Engineers name:
Lorraine Katz Tigard,OR 97223
Address: 10800 SW Avery Street \pplications for"minor work in fight-of-way"
only may be emailed to:
City/state: Tualatin, OR zip: 97062 m"ermits fgaQ�oov
Phone: 503-672-5484 Email:
FOR STAFF I SE ONLY
Estimated value of work (within the public right-of-way): $ Case No.: P—p/o s-
Application submittal fee: —0
—
Is work related to a LAND-USE DECISION? ❑ Yes W No Application accepted:
If so,please specify (MLP,SDR,SUB,etc.) case #: By: Date:
Is work related to a BUILDING PERMIT? ❑ Yes 8 No Application reviewed:
If so,please specify(BUILDING PERMIT)case#: By:, — Dare:/
Applicant notified: J
By: Date:
I:\CURPIN\Masten\land Use Applkations Rev.07/16/2010
City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 www.tigard-or.gov • 503-718-2421 • Page 1 of 4
vo,,o�g
APPLICANTS
NOTE: Person specified as `Applicant"shall be designated"Permittee"and shall provide financial assurance for work.
*When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written
authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written
authorization with this application.
BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT:
• The above request does not violate any deed restrictions that may be attached to or imposed upon the subject proper4.
• If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria, and understands the
requirements for approving or denying the application.
SIGNATURES of each owner of the subject property required.
, Digitally sipby TSAHAI ANDERSON
" A -PGF,ANDERSON emaSARAIANDERSON@PGNCOM' US TSahal Anderson 10/26/15
Dale.:2015 10 26 08'54 23-07'00'
Applicant/Authorized Agent's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of 4
yr-1,
1 16'
1r z5m
20
ABC 500 1453
D I7
141
46
16'- 16•uN.NPNR
POW11 701 2010 '6'-U w n
10 w
Vr.1BS CONSTRUCTION NOTES: CMDEV
+b' 201
1. CUSTOMER IS RESPONSIBLE FOR ALL TRENCH.CONDUIT.VAULTS.PADS
AND ROAD CROSSINGS.
+� 2.ALL CONDUIT TO BE NSTAILLED WITH W INCHES(MIN)COVER AT TOP OF CONDUIT
43
FROM FINAL GRADE.
t47 16' ].ALLPoE CONDUCTORS TOIT 0E INSTALLED IN GRAY SCHEDULES ELECTRICAL
r,4AIh101R1 S,� GRADE.PVC CONCUR WITH NYLON PULL STRINGS DUI S RECURRED TESTI.
2010 �r yT-211 POE TODETERMNETHE SIZE ANDNUMBER ZO TAL.IN INCHES
�� MASAND ITHERTX:AL NCHE5 AND WS 4I CH A S ALLER OEA 36 CE INCH R WEEN
DIUS
17 GAS ANO OTHER UTK ACT ALL ELBOWS L INCH 8 SMALLER TO BE]6 RICH RADIUS
_ ALL KENOS MUST BE FACTORY MApE.ALL ELBOWS URGER THAN 4 INCH TO BE
vr-1� -�{ FOR H RADIUS.RIGID STEEL OR PGE APPROVED,FIBERGLASS BENDS ARE REWIRED
FOR RUNS OF 151 FEET OR LONGER.OR FOR ANY LENGTH RUN WITH MORE THAN
190DEGREES IN BENDS.PVC SCHEDULE AO BENDS ARE ACCEPTABLE FOR RUNS OF
ISO FEET OR LESS.THE MAXPRM TOTAL BENDS N ANY CONDUIT RUN IS 270 DEGREES
1 4. DNECTIONAL BORING REUITY
QUIREMENTS.BLACK HOPE(HIGH DENSPOLYETHELINEI DUCT
1r OR
SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION ICERTA-LOK OR LIKE MECHANICAL
star: WBS
1114 5pR^ 3010 VT.1.6 CONNECTION PRODUCT)AS AN ALTERNITIVE TO HDPE DUCT HOPE SHALL MEET THE
In
'(SO)A- - CONDUIT
RAWG REQUIREMENTS ST PGE SWHICHPECIFICATIWEC2SIS ICATION RECUEONREQUESTFROMPGE PROJECT
'(BO)4'PVC CONWI7 1� 100 v EXTRUpE0 RED STRIPES IWHICH ISASPECIFICATION RECUIREMENTI MANDREL TEST OF
110 1r 1BAN, N DPE PIPE IS REQUIRED AFTER INSTALLATION WRH PGE INSPECTOR PRESENT
18-llnllwwn WL2; 5.ALL PGE TRANSFORMERS TO BE INSTALLED 8 FEET(MIN)FROM ANY COMBUSTIBLE
20 IPAWI; BUILDING,WALL OR OVERHANG AND 4 FEET(MN)FROM ANY FIRE HYDRANT.
, '(21305-ELBOW KR-JKTD CABLE-RK NNCtiPI'Ix. S VT 1ST ALWAYS MANTA NRE10 FEET CL EARANCE IN FRONT OF ALL TE
ABLE AREA
t RANSFORME As
VT193 WL 14 Spm: - WL1 B TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 2 INCHES ABOVE
NRRRAI Install FINAL GRADE CONDUIT IS TO BE INSTALLED N PAD AS INDICATED IN DETAIL
'(170)MM-14SM OF 4A ILL LEAD TXATB{2B '(2)395-ELBOW KA-MTD CEIBIE-RAL AN°TOEXTENDIINCN ABOVETHEPAD.
-(iW)r TL CONDUIT C1� \ J. STEEL BARRIER POSTS ARE RECURRED MOUND TRANSFORMERS THAT ARE EXPOSED
137 TO VEHICLES.
18'-UORmwn B ALL SWITCH VAULTS TO BE SET AT FINK GRADE VATH 61NCH GRAVEL BASE AND
2010 _ CONUDITS ALIGNED TO ENTER THE VAULT END LOWER KNOCKOUTS(TERM-A-WCTSI
1
r-201 (SEE DETAIL ON SKETCH)
7� 9. PGE TO BE NOTIFIED AND INSPECT ALL CONDUIT,VAULT AND PAD INS RIFLED NS.
yT- • � WR CNECNLIST BEFORE BACKFILL ALL NEW VAULT 3 PAD LOCATIONS TO BE FIELD VERIFIED
WITH PGE AND CLIC Ir.•.IFR REPRE SENTATIVE
ITEM YES COMMENT 10 REFMM POE ELECTRICALSERVICE RECUREMBITS BOOK FOR FURTHER DETKS
WL]
HOLEDIGGER 6 SPECIFIC REOUIREMENTB.LINK TO NNNE.PORTIANOGENERAL COMR2ECBOOK
x'654-JUNCTION BOX 1730 UNFUSED CON, 11 DESIGN IS BASED ON STANDARD UNDERGROUND EOUIPTMFNT NON-STANDARD
UNDERGROUND ECUIPTMENT MAYBE AN OPTION AT AN AODRIONAL COST TO
Y'1324 JUNCTION BOX 15, 33 BACKHOE THE CUSTOMER.
201 PGE TRENCH K PGE CONTRACTOR
THE POINT OF DELIVERY AND N OF OWNERSHIP BETWEEN THE CUSTOMER AND
��`
-IN �2 1 I ;F'NII L 01 THE
RE A7 THE LINE SIDE OF THE NEW CUSTOMER PROVIDED SWITCH GEAR
NE,
PO OCATES
TAKING
+�•` VT•1W GOING X
L SCIM
LANDAPE XVicinity'(Re��" fdF a1
-�2t2
EASEMENT rvcw�R•crw + �
W1.4_ PERMITS X CITY OF TIGARD
TRAFFIC P X
JUNCTION �eTM P�J
JUNCTION BOX 1730 UNFUSED CUTSHEEt �Yf M1
— UG 1JR VER. S;v
AHYS,CH, gf
LnST r^NN 6
sUTDOOW1 X 4i i
SHA HOAR
aSS
ON TACT SPrvk•A D"Hal Propcl
OMPANY `1' O-•
0 15 30 BO Feet HN a
TE TIME so
PGE
• IaHR POE CONSTRUCTION DRAWING
AS-e UILT VERIFICATION 6 NESC VICLA710N5 CORRCCTED
-e.au LEBQQ
BTF~SVATCH544U1TIIRM�,. 0-•• •
ra uaaH,"aw ®�� Foramen: Dere:
`� rHr wares j THINK
General Foreman: Defe:
SAFETY
�i TI- I\�. SETATLOUnCNS
FIRST SDPM^ENG REVIEW. ASBUILTBYDESIGNER:
TE' AL- ALCOUNr AWO N I
SEILET
2 TOP OFLn To 10/23/2015 1";30' 1070001 1000004545 .1853525
MAN Lr ATFNAL RxNPP MIN. TITLE
TO Ran Avmo—aYPGE +.^w.r.nrc.Tr.,e., 4«..e•T4.H.c•ry PGE-CAPSTONE GREENLIGHT-Ash Ave.FaCility Trespass Relocation
L91LRrrlr J W rrorfie0.5s 1 ` LIRCUI7 SIZE 17x22
4-10 eErH1N
Ho s� IArs TIGARO-13337
CONTACT SfRV7CE COORO/NATOR nFMT10N. CALL 111 rEFORE YOU DLG L
ro lvFrt e A INS.U.—Lb NIS ,I„ ��/ SW ASH 8 SW BURNHAM,TIGARD
rlln-0TESTPIAl _ ._ -Rpt .I EGONIAW REOUM(S YOU TO 1.1LOWRULES ADORTEO B
STRING W EALM PVL RY rH[OF SON UrIt ITY NOTI-PON CENTER.
9 I= I^I THOSERUtESARESErrO4rNINmRRS2-MI 0010 ` RELOCATE PRIMARY BSTREETLIGHT FACILITIES SHEET
SERVICE COORDINATOR THROUGH 252 MI XBO roU MAY OBTAIN COPIES Or CO SEC 5 RK WI N
IT 8• S03-TS&S4S0 DR SOIJIM-43t6(SALEMI THE RULES RVCALLING ME OREGON UTILITY WASHINGTON C21-02A fOF1
__ NOrlr1UrroNCEN TER ROMIMsrAAIN)N III-2)J In,
aWH,ar® Or
r YDEV7A IIONFROM TkODE.AGNMOT TO REOUFST UTITTY LOCATES CALL THE DREGON Ih�n R41NR bB102R NF CREW CENTER LORRAINE KATZ 6725484 MASON HODGES
Y(SEEP ISL7a VT 82 UTILITY NOTIFICATION CENTER,111 AT LEAST CB�Ilabl—d4
!BEAM2VVED8YT 89IRROJECTMAill 7BUSINESS DAYS PRIOR TOEXCAVATON
DEVELOPMENT ENGINEERING FEES
1. Public Facility Improvement(PFI) Permit:
Part 1: Required submittal fee$300.00
Part 2: All non-water system improvements
Engineer's estimate X 5% (less$300.00 subinittal fee)
Engineer's estimate X 2%Plan Review
Part 3: All public water system improvements
Engineer's estimate X 12%
Total Permit Fee = Part 2 + Part 3
PFI Permit Fee Exemptions:
There will be no permit fee charged,or assurance required for the following types of work:
• Sidewalk or driveway repair(less than 20 lineal feet)
• Relocate or replace mailbox
• Ditch cleaning that does not involve regrading.
• Weephole repair
• Curb repair or replacement(less than 20 lineal feet)
• Lawn sprinkler system installation or repair
• Street tree pruning or planting
• Planter strip landscape maintenance
• Test wells
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 Page 3 of 4
SAMPLE SKETCH:
SW '119Y99 St
Edge of Pavement
I +— Ditch —�
n Streetlight -— ----------- —r---
Run Dram
' T—�iopos r5iewerTrie"
�
N� I
I � Existing House
Existing
Driveway
a� vi I
al I
IL
'4
'4' I i -
I CID
I
�I -
i I Existing Shop I
t
Powerpole
I—-------7-roP95ine------- ---
� I
I a I Fire Hydrant(FH)
I i I
Scale: -1"=30'
I
� I I
� I I
� � I
MINIMUM SKETCH REQUIREMENTS (Put"N/A" if Not Applicable):
North arrow Property lines&dimension Slope of property
Street&street name(s) Existing building,structures Utility&street light poles
Proposed work Existing curb or edge Trees
Existing S/W or of pavement Existing utility locations
D/W apron (sewer,water,storm)
PUBLIC FACILITY IMPROVEMENT PERMIT
City of Tigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 - www.tigard-or.gov - 503-718-2421 - Page 4 of 4