PFI2015-00156 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12015-00156 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 11/25/2015 Parcel: SEG1145 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: Adjacent to SW Ash Avenue&SW Burnham Street. Relocate primary&streetlight facilities(Ash Avenue Apartments-Relocate prim &STLT secondary for new building) Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX: Applicant: TSAHAI ANDERSON 10800 SW AVERY ST TUALATIN, OR 97062 PHONE: 503-612-6106 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Not Present Signature: Issued By: � Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12015-00156 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08- TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice RECEIVED City of Tigard OCT 2 6 2015 PUBLIC WORKS — ENGINEERING PGE WORK ORDER# M185M*¢OF TIGARD PLANNING/ENGINEERING Public Facility Improvement (PFI) Permit DESCRIPTION OF WORK(in the right-of-way) REQUIRED SUBMITTAL Check one: 8 Utilities ❑ Sidewalk/driveway approach ❑ Street improvements ELEMENTS rY 9 Detailed description: Relocate Prima & Streetlight facilities M %linorwork in right-of-way (sidewalk repair,curb cut,street (Ash Avenue Apts- Relocate Prim & STLT Secondary for new Bldg) opening,etc.)requires: •Application form,completed and signed •Submit one(1)copy of scaled sketch Property address/location(s): Sw Ash & SW Burnham, Tigard of the proposed work to be done •Submit one(1)copy of traffic control plan —OR— Applicant's name: Tsahai Anderson E] Substantial project work requires PP above items and professional Address: 10800 SW Avery Street engineered plans for: Tualatin, OR 97062 •Street widening Cit;/state: Lip: •Subdivision infrastructure Phone: 503-612-6106 Email: T&DsupportAvery@pgn.com •Main utility line extension: - Storm Drain,Sanitary—Tigard - Water—Tigard Water Service Contractor's name: TBD after Bid Area(includes Durham,King City CCB#: Expiration: and a portion of unincorporated Washington County) Address: City/state: zip: DELIVER APPLICATION TO: City of Tigard Phone: Email: Planning/Engineering 13125 SW Hall Blvd. Engineers name: Lorraine Katz Tigard,OR 97223 Address: 10800 SW Avery Street \pplications for"minor work in fight-of-way" only may be emailed to: City/state: Tualatin, OR zip: 97062 m"ermits fgaQ�oov Phone: 503-672-5484 Email: FOR STAFF I SE ONLY Estimated value of work (within the public right-of-way): $ Case No.: P—p/o s- Application submittal fee: —0 — Is work related to a LAND-USE DECISION? ❑ Yes W No Application accepted: If so,please specify (MLP,SDR,SUB,etc.) case #: By: Date: Is work related to a BUILDING PERMIT? ❑ Yes 8 No Application reviewed: If so,please specify(BUILDING PERMIT)case#: By:, — Dare:/ Applicant notified: J By: Date: I:\CURPIN\Masten\land Use Applkations Rev.07/16/2010 City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 www.tigard-or.gov • 503-718-2421 • Page 1 of 4 vo,,o�g APPLICANTS NOTE: Person specified as `Applicant"shall be designated"Permittee"and shall provide financial assurance for work. *When the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. BY SIGNING BELOW, THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any deed restrictions that may be attached to or imposed upon the subject proper4. • If the application is granted, the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria, and understands the requirements for approving or denying the application. SIGNATURES of each owner of the subject property required. , Digitally sipby TSAHAI ANDERSON " A -PGF,ANDERSON emaSARAIANDERSON@PGNCOM' US TSahal Anderson 10/26/15 Dale.:2015 10 26 08'54 23-07'00' Applicant/Authorized Agent's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of 4 yr-1, 1 16' 1r z5m 20 ABC 500 1453 D I7 141 46 16'- 16•uN.NPNR POW11 701 2010 '6'-U w n 10 w Vr.1BS CONSTRUCTION NOTES: CMDEV +b' 201 1. CUSTOMER IS RESPONSIBLE FOR ALL TRENCH.CONDUIT.VAULTS.PADS AND ROAD CROSSINGS. +� 2.ALL CONDUIT TO BE NSTAILLED WITH W INCHES(MIN)COVER AT TOP OF CONDUIT 43 FROM FINAL GRADE. t47 16' ].ALLPoE CONDUCTORS TOIT 0E INSTALLED IN GRAY SCHEDULES ELECTRICAL r,4AIh101R1 S,� GRADE.PVC CONCUR WITH NYLON PULL STRINGS DUI S RECURRED TESTI. 2010 �r yT-211 POE TODETERMNETHE SIZE ANDNUMBER ZO TAL.IN INCHES �� MASAND ITHERTX:AL NCHE5 AND WS 4I CH A S ALLER OEA 36 CE INCH R WEEN DIUS 17 GAS ANO OTHER UTK ACT ALL ELBOWS L INCH 8 SMALLER TO BE]6 RICH RADIUS _ ALL KENOS MUST BE FACTORY MApE.ALL ELBOWS URGER THAN 4 INCH TO BE vr-1� -�{ FOR H RADIUS.RIGID STEEL OR PGE APPROVED,FIBERGLASS BENDS ARE REWIRED FOR RUNS OF 151 FEET OR LONGER.OR FOR ANY LENGTH RUN WITH MORE THAN 190DEGREES IN BENDS.PVC SCHEDULE AO BENDS ARE ACCEPTABLE FOR RUNS OF ISO FEET OR LESS.THE MAXPRM TOTAL BENDS N ANY CONDUIT RUN IS 270 DEGREES 1 4. DNECTIONAL BORING REUITY QUIREMENTS.BLACK HOPE(HIGH DENSPOLYETHELINEI DUCT 1r OR SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION ICERTA-LOK OR LIKE MECHANICAL star: WBS 1114 5pR^ 3010 VT.1.6 CONNECTION PRODUCT)AS AN ALTERNITIVE TO HDPE DUCT HOPE SHALL MEET THE In '(SO)A- - CONDUIT RAWG REQUIREMENTS ST PGE SWHICHPECIFICATIWEC2SIS ICATION RECUEONREQUESTFROMPGE PROJECT '(BO)4'PVC CONWI7 1� 100 v EXTRUpE0 RED STRIPES IWHICH ISASPECIFICATION RECUIREMENTI MANDREL TEST OF 110 1r 1BAN, N DPE PIPE IS REQUIRED AFTER INSTALLATION WRH PGE INSPECTOR PRESENT 18-llnllwwn WL2; 5.ALL PGE TRANSFORMERS TO BE INSTALLED 8 FEET(MIN)FROM ANY COMBUSTIBLE 20 IPAWI; BUILDING,WALL OR OVERHANG AND 4 FEET(MN)FROM ANY FIRE HYDRANT. , '(21305-ELBOW KR-JKTD CABLE-RK NNCtiPI'Ix. S VT 1ST ALWAYS MANTA NRE10 FEET CL EARANCE IN FRONT OF ALL TE ABLE AREA t RANSFORME As VT193 WL 14 Spm: - WL1 B TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 2 INCHES ABOVE NRRRAI Install FINAL GRADE CONDUIT IS TO BE INSTALLED N PAD AS INDICATED IN DETAIL '(170)MM-14SM OF 4A ILL LEAD TXATB{2B '(2)395-ELBOW KA-MTD CEIBIE-RAL AN°TOEXTENDIINCN ABOVETHEPAD. -(iW)r TL CONDUIT C1� \ J. STEEL BARRIER POSTS ARE RECURRED MOUND TRANSFORMERS THAT ARE EXPOSED 137 TO VEHICLES. 18'-UORmwn B ALL SWITCH VAULTS TO BE SET AT FINK GRADE VATH 61NCH GRAVEL BASE AND 2010 _ CONUDITS ALIGNED TO ENTER THE VAULT END LOWER KNOCKOUTS(TERM-A-WCTSI 1 r-201 (SEE DETAIL ON SKETCH) 7� 9. PGE TO BE NOTIFIED AND INSPECT ALL CONDUIT,VAULT AND PAD INS RIFLED NS. yT- • � WR CNECNLIST BEFORE BACKFILL ALL NEW VAULT 3 PAD LOCATIONS TO BE FIELD VERIFIED WITH PGE AND CLIC Ir.•.IFR REPRE SENTATIVE ITEM YES COMMENT 10 REFMM POE ELECTRICALSERVICE RECUREMBITS BOOK FOR FURTHER DETKS WL] HOLEDIGGER 6 SPECIFIC REOUIREMENTB.LINK TO NNNE.PORTIANOGENERAL COMR2ECBOOK x'654-JUNCTION BOX 1730 UNFUSED CON, 11 DESIGN IS BASED ON STANDARD UNDERGROUND EOUIPTMFNT NON-STANDARD UNDERGROUND ECUIPTMENT MAYBE AN OPTION AT AN AODRIONAL COST TO Y'1324 JUNCTION BOX 15, 33 BACKHOE THE CUSTOMER. 201 PGE TRENCH K PGE CONTRACTOR THE POINT OF DELIVERY AND N OF OWNERSHIP BETWEEN THE CUSTOMER AND ��` -IN �2 1 I ;F'NII L 01 THE RE A7 THE LINE SIDE OF THE NEW CUSTOMER PROVIDED SWITCH GEAR NE, PO OCATES TAKING +�•` VT•1W GOING X L SCIM LANDAPE XVicinity'(Re��" fdF a1 -�2t2 EASEMENT rvcw�R•crw + � W1.4_ PERMITS X CITY OF TIGARD TRAFFIC P X JUNCTION �eTM P�J JUNCTION BOX 1730 UNFUSED CUTSHEEt �Yf M1 — UG 1JR VER. S;v AHYS,CH, gf LnST r^NN 6 sUTDOOW1 X 4i i SHA HOAR aSS ON TACT SPrvk•A D"Hal Propcl OMPANY `1' O-• 0 15 30 BO Feet HN a TE TIME so PGE • IaHR POE CONSTRUCTION DRAWING AS-e UILT VERIFICATION 6 NESC VICLA710N5 CORRCCTED -e.au LEBQQ BTF~SVATCH544U1TIIRM�,. 0-•• • ra uaaH,"aw ®�� Foramen: Dere: `� rHr wares j THINK General Foreman: Defe: SAFETY �i TI- I\�. SETATLOUnCNS FIRST SDPM^ENG REVIEW. ASBUILTBYDESIGNER: TE' AL- ALCOUNr AWO N I SEILET 2 TOP OFLn To 10/23/2015 1";30' 1070001 1000004545 .1853525 MAN Lr ATFNAL RxNPP MIN. TITLE TO Ran Avmo—aYPGE +.^w.r.nrc.Tr.,e., 4«..e•T4.H.c•ry PGE-CAPSTONE GREENLIGHT-Ash Ave.FaCility Trespass Relocation L91LRrrlr J W rrorfie0.5s 1 ` LIRCUI7 SIZE 17x22 4-10 eErH1N Ho s� IArs TIGARO-13337 CONTACT SfRV7CE COORO/NATOR nFMT10N. CALL 111 rEFORE YOU DLG L ro lvFrt e A INS.U.—Lb NIS ,I„ ��/ SW ASH 8 SW BURNHAM,TIGARD rlln-0TESTPIAl _ ._ -Rpt .I EGONIAW REOUM(S YOU TO 1.1LOWRULES ADORTEO B STRING W EALM PVL RY rH[OF SON UrIt ITY NOTI-PON CENTER. 9 I= I^I THOSERUtESARESErrO4rNINmRRS2-MI 0010 ` RELOCATE PRIMARY BSTREETLIGHT FACILITIES SHEET SERVICE COORDINATOR THROUGH 252 MI XBO roU MAY OBTAIN COPIES Or CO SEC 5 RK WI N IT 8• S03-TS&S4S0 DR SOIJIM-43t6(SALEMI THE RULES RVCALLING ME OREGON UTILITY WASHINGTON C21-02A fOF1 __ NOrlr1UrroNCEN TER ROMIMsrAAIN)N III-2)J In, aWH,ar® Or r YDEV7A IIONFROM TkODE.AGNMOT TO REOUFST UTITTY LOCATES CALL THE DREGON Ih�n R41NR bB102R NF CREW CENTER LORRAINE KATZ 6725484 MASON HODGES Y(SEEP ISL7a VT 82 UTILITY NOTIFICATION CENTER,111 AT LEAST CB�Ilabl—d4 !BEAM2VVED8YT 89IRROJECTMAill 7BUSINESS DAYS PRIOR TOEXCAVATON DEVELOPMENT ENGINEERING FEES 1. Public Facility Improvement(PFI) Permit: Part 1: Required submittal fee$300.00 Part 2: All non-water system improvements Engineer's estimate X 5% (less$300.00 subinittal fee) Engineer's estimate X 2%Plan Review Part 3: All public water system improvements Engineer's estimate X 12% Total Permit Fee = Part 2 + Part 3 PFI Permit Fee Exemptions: There will be no permit fee charged,or assurance required for the following types of work: • Sidewalk or driveway repair(less than 20 lineal feet) • Relocate or replace mailbox • Ditch cleaning that does not involve regrading. • Weephole repair • Curb repair or replacement(less than 20 lineal feet) • Lawn sprinkler system installation or repair • Street tree pruning or planting • Planter strip landscape maintenance • Test wells PUBLIC FACILITY IMPROVEMENT PERMIT City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 Page 3 of 4 SAMPLE SKETCH: SW '119Y99 St Edge of Pavement I +— Ditch —� n Streetlight -— ----------- —r--- Run Dram ' T—�iopos r5iewerTrie" � N� I I � Existing House Existing Driveway a� vi I al I IL '4 '4' I i - I CID I �I - i I Existing Shop I t Powerpole I—-------7-roP95ine------- --- � I I a I Fire Hydrant(FH) I i I Scale: -1"=30' I � I I � I I � � I MINIMUM SKETCH REQUIREMENTS (Put"N/A" if Not Applicable): North arrow Property lines&dimension Slope of property Street&street name(s) Existing building,structures Utility&street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City of Tigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 - www.tigard-or.gov - 503-718-2421 - Page 4 of 4