Loading...
Report , /Pr 5 t ).Ul City of Tigard / / s4) // '' Building Division 1 EC OVED ' mi13125 SW Hall Blvd,Tigard, OR 97223 NOV 16 2015 Phone: 503.718.2439 Fax: 503.598.1960 T I GARD Inspection Line: 503.639.4175 CITY OF TIGARD www.tigard-or.gov BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 9131 SW HILL ST City: TIGARD Zip: 97223 Owner's Name: Dirksen, Craig Date: 11.13.15 Contractor's Name: SOLAR CITY CCB #: 180498 / G \ • Design Parameters of the Property/Structure ( If"Yes", does not Flood Hazard Is the installation ❑ Yes f qualify for the Located in a flood prescriptive path, follow Area plain/flood way? ® No OSS'C-r ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above No 1 I:Building/Forms/PhotoVoltaic-Checklist.docx • Is the construction Type of material wood and does Yes If"Yes", qualifies for the construction qualify Constructionas "conventional light n No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. n Yes If"Yes", qualifies for the prescriptive path. ® No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar • equal to 4.5 psf? • installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? n Metal Single layer If roofing material is Roofing Check the type of n of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers - the prescriptive path. 171 of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof No the presIf"Yescriptive path. s qualifies for 111to the roof framing or blocking directly? 2 I:/Building/Fomes/PhotoVoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directlyto inches inches, qualifies for the Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/z"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 UBuilding/Forms/Photo Voltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Model Number: 260 Listing Agency: UL1703 4 I:/Building/Forms/Photovoltaic-Checklist.docx