Loading...
Report ST 62 01 S= O v 221--/ II Dt 2 561} NOV 1 9 2015 BeamChek v2009 licensed to:Dennis TroxeUTroxel's Home Design Reg#8101-1403 #1228(GOFFMOORE) KIT BEAM#1 Date: 3/22/12BURDn` G DWIISION Selection (2)2x 12 DF-L#2 Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=1.5 in2 R2=1.5 in2 (1.5)DL Defl= <0.01 in. Data Beam Span 3.83 ft Reaction 1 LL 747# Reaction 2 LL 747# Beam Wt per ft 8.2# Reaction 1 TL 949# Reaction 2 TL 949# Bm Wt Included 31 # Maximum V 949# Max Moment 909'# Max V(Reduced) 485# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section(in3) Shear(ins) TL Defl(in) LL Defl Actual 63.28 33.75 0.00 <0.01 Critical 12.12 4.04 0.19 0.13 Status OK OK OK OK Ratio 19% 12% 2% 3% Fb(psi) Fv(psi) E(psi x mil) Fci.(psi) Values Reference Values 900 180 1.6 625 Adjusted Values 900 180 1.6 625 Adjustments CF Size Factor 1.000 • Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:390 Uniform TL: 488 =A Uniform Load A R1 =949 R2=949 SPAN=3.83 FT Uniform and partial uniform loads are lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxel/Troxel's Home Design Reg#8101-1403 #1228(GOFFMOORE) GREAT RM BEAM#2 Date:3/22/12 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=9.3 in2 R2=9.3 in2 (1.5)DL Defl= 0.22 in Recom Camber=0.33 in Data Beam Span 13.0 ft Reaction 1 LL 4072# Reaction 2 LL 4072# Beam Wt per ft 14.94# Reaction 1 TL 6032# Reaction 2 TL 6032# Bm Wt Included 194# Maximum V 6032# Max Moment 19603'# Max V(Reduced) 5104# TL Max Defl L/240 TL Actual Defl L/299 LL Max Defl L/360 LL Actual Defl L/516 Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl Actual 123.00 61.50 0.52 0.30 Critical 98.01 31.90 0.65 0.43 Status OK OK OK OK Ratio 80% 52% 80% 70% Fb(psi) Fv(psi) E(psi x mil) Fc.J..(psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:626 Uniform TL: 913 =A Uniform Load A R1 =6032 R2=6032 SPAN=13 FT Uniform and partial uniform loads are lbs per lineal ft. • • BeamChek v2009 licensed to:Dennis TroxeUTroxers Home Design Reg#8101-1403 #1228(GOFFMOORE) DINE RM BEAM#3 Date: 3/22/12 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu =0.0 Ft Conditions NDS 2005 Min Bearing Area R1=5.4 in= R2=5.4 in2 (1.5)DL Defl= 0.30 in Recom Camber-,0.45 in Data Beam Span 16.0 ft Reaction 1 LL 2071 # Reaction 2 LL 2071 # Beam Wt per ft 14.94# Reaction 1 TL 3504# Reaction 2 TL 3504# Bm Wt Included 239# Maximum V 3504# Max Moment 14014'# Max V(Reduced) 3066# TL Max Defl L/240 TL Actual Defl L/328 LL Max Defl L/360 LL Actual Defl L/669 Attributes Section(in') Shear(in2) TL Defl(in) LL Defl Actual 123.00 61.50 0.58 0.29 Critical 70.07 19,16 0.80 0.53 Status OK OK OK OK Ratio 57% 31% 73% 54% Fb(psi) Fv(psi) E(psi x mil) Fc (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:259 Uniform TL: 423 =A Uniform Load A R1 =3504 ft2 3504 SPAN=16 FT Uniform and partial uniform loads are lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxe/Troxel's Home Design Reg#8101-1403 #1228(GOFFMOORE) DINE RM BEAM#4 Date: 3/22/12 Selection (2)2x 12 DF-L#2 Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=3.2 in2 R2=3.2 in2 (1.5)DL Defl= 0.02 in Data Beam Span 6.0 ft Reaction 1 LL 1294# Reaction 2 LL 1294# Beam Wt per ft 8.2# Reaction 1 TL 1984# Reaction 2 TL 1984# Bm Wt Included 49# Maximum V 1984# Max Moment 2975'# Max V(Reduced) 1364# TL Max Defl L/240 TL Actual Defl L/>1000 LL Max Dell L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in2) TL Defl(in) LL Defl Actual 63.28 33.75 0.04 0.02 Critical 39.67 11.36 0.30 0.20 Status OK OK OK OK Ratio 63% 34% 13% 11% Fb(psi) Fv(psi) E(psi x mil) Fc.1(psi) Values Reference Values 900 180 1.6 625 Adjusted Values 900 180 1.6 625 ,ldlustments CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:431 Uniform TL: 653 =A Uniform Load A R984 RZ 984 SPAN=6 FT • • Uniform and partial uniform loads are lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxel/Troxel's Home Design Reg#8101-1403 #1228(GOFFMOORE) FOYER BEAM#5 Date: 3/22/12 Selection 6x 12 DF-L#2 Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=5.1 in2 R2=5.1 in2 (1.5) DL Defl= 0.09 in Data Beam Span 10.0 ft Reaction 1 LL 2025# Reaction 2 LL 2025# Beam Wt per ft 15.37# Reaction 1 TL 3177# Reaction 2 TL 3177# Bm Wt Included 154# Maximum V 3177# Max Moment 7942'# Max V(Reduced) 2568# TL Max Defl L/240 TL Actual Defl L/645 LL Max Dell L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(In') TL Deft(in) LL Deft Actual 121.23 63.25 0.19 0.10 Critical 108.92 22.66 0.50 0.33 Status OK OK OK OK Ratio 90% 36% 37% 30% Fb(psi) Fv(psi) E(psi x mli) Fol.(psi) Values Reference Values 875 170 1.3 625 Adjusted Values 875 170 1.3 625 Adjustments CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft • Loads Uniform LL:405 Uniform TL: 620 =A • Uniform Load A /\ R1 =3177 R2=3177 SPAN=10 FT Uniform and partial uniform loads are lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxel/Troxel's Home Design Reg#8101-1403 • #1228(GOFFMOORE) GARAGE BEAM#6 Date:3/22/12 Selection 6x 12 DF-L#2 Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=4.1 in2 R2=4.1 in2 (1.5) DL Defl= 0.04 in Data Beam Span 10.0 ft Reaction 1 LL 2000# Reaction 2 LL 2000# Beam Wt per ft 15.37# Reaction 1 TL 2577# Reaction 2 TL 2577# Bm Wt Included 154# Maximum V 2577# Max Moment 6442'# Max V(Reduced) 2083# TL Max Defl L/240 TL Actual Defl L/845 LL Max Defl L/360 LL Actual Defl L/>1000 Attributes Section(in') Shear(in2) TL Defl(in) LL Defl Actual 121.23 63.25 0.14 0.10 Critical 88.35 18.38 0.50 0.33 • Status OK OK OK OK Ratio 73% 29% 28% 30% Fb(psi) Fv(psi) E(psi x mil) Fc (psi) Values Reference Values 875 170 1.3 625 Adjusted Values 875 170 1.3 625 Adiustments CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:400 Uniform TL: 500 =A Uniform Load A R1 =2577 R2=2577 SPAN= 10 FT Uniform and partial uniform loads are lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxellrroxel's Home Design Reg#8101-1403 #1228B(GOFFMOORE) GARAGE BEAM#7 Date:7/20/12 Selection 5-1/8x 16-1/2 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=9.5 in2 R2=8.4 in2 (1.5)DL Defl= 0.22 in Recom Camber=0.33 in Data Beam Span 19.5 ft Reaction 1 LL 4435# Reaction 2 LL 4123# Beam Wt per ft 20.55# Reaction 1 TL 6200# Reaction 2 TL 5439# Bm Wt Included 401 # Maximum V 6200# Max Moment 27754'# Max V(Reduced) 5264# IL Max Defl L/240 TL Actual Defl L/355 LL Max Defl L/360 LL Actual Defl L/536 Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl Actual 232.55 84.56 0.66 0.44 Critical 142.20 32.90 0.98 0.65 Status OK OK OK OK Ratio 61% 39% 68% 67% Fb(psi) Fv(psi) E(psi x mil) Fc (psi) Values Reference Values 2400 240 1.8 650 Adjusted Values 2342 240 1.8 650 Adiustments Cv Volume 0.976 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 290 B=397 5.75 458 H=660 0 5.75 410 I=513 5.75 19.5 H Pt loads: B R1 =6200 R2=5439 SPAN= 19.5 FT Uniform and partial uniform loads are lbs per lineal ft. . BeamChek v2009 licensed to:Dennis TroxeUTroxel's Home Design Reg#8101-1403 #1228B(GOFFMOORE) GARAGE DR BEAM#8 Date: 7/20/12 Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=4.1 in= R2=4.1 in2 (1.5)DL Defl= 0.31 in Recom Camber=0.47 in Data Beam Span 16.5 ft Reaction 1 LL 1507# Reaction 2 LL 1450# Beam Wt per ft 14.94# Reaction 1 TL 2636# Reaction 2 TL 2678# Bm Wt Included 247# Maximum V 2678# Max Moment 12159'# Max V(Reduced) 2541 # • TL Max Deft L/240 TL Actual Defl L/344 LL Max Defl L/360 LL Actual Defl L 1757 Attributes Section(in') Shear(in2) TL Defl(in) LL Defl Actual 123.00 61.50 0.57 0.26 Critical 60.79 15.88 0.83 0.55 Status OK OK OK OK Ratio 49% 26% 70% 48% Fb(psi) Fv(psi) E(psi x mil) Fc...1_(psi) Va es Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Adjustments Cv Volume 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 791 B= 1297 4.5 60 H=80 0 4.25 156 I =280 4.25 16.5 H Pt loads: EI R1 =2636 R2=2678 SPAN=16.5 FT Uniform and partial uniform loads aie lbs per lineal ft. BeamChek v2009 licensed to:Dennis Troxel/Troxel's Home Design Reg#8101-1403 #12288(GOFFMOORE) PATIO BEAM#11 Date:7/20/12 Selection 6x 8 DF-L#2 Lu=0.0 Ft Conditions NDS 2005,Wet Use Min Bearing Area R1= 1.8 in' R2=1.8 in' (2.0)DL Defl= 0.08 in Data Beam Span 10.0 ft Reaction 1 LL 525# Reaction 2 LL 525# Beam Wt per ft 10.02# Reaction 1 TL 750# Reaction 2 TL 750# Bm Wt Included 100# Maximum V 750# Max Moment 1875'# Max V(Reduced) 656# TL Max Defl L/180 TL Actual Defl L/688 LL Max Defl L/240 LL Actual Defl L/>1000 Attributes Section(in') Shear(in') TL Defl(in) LL Deft Actual 51.56 41.25 0.17 0.09 Critical 26.09 5.04 0.67 0.50 Status OK OK OK OK Ratio 51% 12% 26% 19% Fb(psi) Fv(psi) E(psi x mil) Fc!(psi) Values Reference Values 750 170 1.3 625 Adjusted Values 863 196 1.3 419 Adjustments CF Size Factor 1.000 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 0.67 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL: 105 Uniform TL: 140 =A Uniform Load A. • R1 =750 R2=750 SPAN=10FT Uniform and partial uniform loads are lbs per lineal ft. TROXEL'S HOME DESIGN BeamChek v2009 licensed to:DENNIS TROXELlTROXEL'S HOME DESIGN Reg#8101-1403 PLAN#1228 B GOFFMOORE DECK SUPPORT BEAM#12 Prepared by:D.T. Date:3/07/14 Selection 4x 12 DF-L#2 Lu=0.0 Ft Conditions NDS 2005,Wet Use Min Bearing Area R1=5.3 in' R2=5.3 int (2.0)DL Defl= 0.09 in Data Beam Span 10.5 ft Reaction 1 LL 1748# Reaction 2 LL 1748# Beam Wt per ft 9.57# Reaction 1 TL 2239# Reaction 2 TL 2239# Bm Wt Included 100# Maximum V 2239# Max Moment 5879'# Max V(Reduced) 1840# TL Max Defl L/240 TL Actual Defl L/531 LL Max Defl L/360 LL Actual Defl L/829 Attributes Section(in3) Shear(in') TL Defl(in) LL Defl Actual 73.83 39.38 0.24 0.15 Critical 71.26 15.80 0.53 0.35 Status OK OK OK OK Ratio 97% 40% 45% 43% Fb(psi) Fv(psi) E(psi x mil) Fol.(psi) atues Reference Values 900 180 1,6 625 Adjusted Values 990 175 1.4 419 Adjustments CF Size Factor 1.100 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 0.97 0.90 0.67 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:333 Uniform IL: 417 =A Uniform Load A R1 =2239 R2=2239 SPAN=10.5 FT Uniform and partial uniform loads are lbs per lineal ft.