Loading...
Report (33) Cps 090-? ! INSPECTION AND TESTING FORM DATE: // —/2 — ZO lsf TIME: 1 4/72 SERVICE ORGANIZATION PROPERTY NAME(USER)/ Name: CSC-,.^ f I /,4 14/f1C/7A/ Name: G[`'D/l% /0/ (11///1 377,y Address: 47//9 .✓�,/i 47eIh,Cl/Q 4 / uC�'l." ,4 e -- Address:"a 7 13 SW 6g741 ,f' ode S' Afr(/ ^/0 //�Q7 Owner Contact: �{ ^.( -(' forest, / Representative: -_(�P /��' ?�, ��� License No.:�JSC y 3 9 7.3 S Telephone: 5 5 5 9 a.6 Telephone: 5 3 %f 7 7'.O 2., MONITORING ENTITY APPROVING AGENCY Contact: L 'Y q Contact: trl",,4 (UC'/I/y .a.pd . 7 Telephone: 6-1)43 G' .S� -�� L1 Telephone: ��03 Sc)O /3--c-r ? Monitoring Account Ref.No.: 3 ' v q� CH(/ of / ! Cj cCl 5O 7/8 V. TYPE TRANSMISSION SERVICE • McCulloh 3 Weekly 3 Multiplex 3 Monthly Digital D Quarterly J Reverse Priority 3 Semiannually J RF 3 Annually // / 3 Other(Specify) 3 Other(Specify) kW/75-M/ TS (44- -74r, f Control Unit Manufacturer: 5i/f'4 f nn//I/1 / Model No.:5-Q X/ <5//.C/ Circuit Styles: (j 4_9/Cl s5 C (�CL� Number of Circuits: c5/_Lt(2,) //4 e(9) Ore 7P ( 47) ( �Y� Software Rev.: Last Date System Had Any Service Perfomied: /.1 '02 �S Last Date that Any Software or Configuration Was Revised: /7/ ' - /S ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style (p �� - CUSS y Manual Fire Alarm Boxes Ion Detectors S LC_-P'l()fA(t'SS040-- Photo Detectors Duct Detectors Heat Detectors Waterfow Switches SLR _� �!/Z°SS� �- Supervisory Switches (e4f1 ' Other(Specify): (NFPA Inspection and Testing 1 of 4) ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION Quantity Circuit Style Bells Horns Chimes Strobes I / Speakers y Neu) /3 ( 5 a old) Other(Specify): /74a4/1//5-7-60X6----;_c No.of alarm notification appliance circuits: `7 Are circuits monitored for integrity? ,Yes ❑ No SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style Building Temp. Site Water Temp. Site Water Level Fire Pump Power Fire Pump Running Fire Pump Auto Position Fire Pump or Pump Controller Trouble Fire Pump Running Generator In Auto Position Generator or Controller Trouble Switch Transfer ( Generator En One Running Other: c2 C h Id C-iie.iu t . • - , G h • SIGNALING LINE CIRCUITS Quantity and style(See NFPA 72,Table 3-6)of signaling line circuits connected to system: Quantity 7- SLC Style(s) SYSTEM POWER SUPPLIES a. Primary(Main): Nominal Volta e 42-0 ��'� ,Amps Overcurrent Protection: Type S e Gl K P r ,Amps_2 i2 Location(of Primary Supply Panelboard): 2�' ' �L��� L� n/I Disconnecting Means Location: b. Secondary(Standby): `/Y"r( Storage Battery: Amp-Hr.Rating Calculated capacity to operate system,in hours: /0 A9. Nt cti✓1 24 4 N /04—(,60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: TYPE BATTERY D Dry Cell D Nickel-Cadmium ..— Sealed Lead-Acid • Lead-Acid • Other(Specify): c. Emergency or standby system used as a backup to primary power supply,instead of using a secondary power supply: Emergency system described in NFPA 70,Article 700 Legally required standby described in NFPA 70,Article 701 Optional standby system described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. (NFPA Inspection and Testing 2 of 4) • d PRIOR TO ANY TESTING 10(a 1 —d Ef ec-4'orS NOTIFICATIONS ARE MADE Yes No Who Time _ Monitoring Entity 0 C‘ � / S 7700 / 4, Building Occupants 0 ,j'-(I-P i)P A1j c,i 4' Building Management 0 0 ..5-on-v1/4_,L ' Other(Specify) 0 0 Alit(Notified)of Any Impairments ❑ 0 SYSTEM TESTS AND INSPECTIONS r//e? ^ v-7$l'as TYPE Visible Functional Comments Control Unit 0 Interface Eq. Lamps/LEDS _ Fuses Primary Power Supply Trouble Signals Disconnect Switches Ground-Fault Monitoring SECONDARY POWER TYPE Visible Functional Comments Battery Condition 0 1 . -f 1 jJ ao4 e ,,J.74.4 Load Voltage 0 V Discharge Test 0 / (U C I . ArtNNW- Charger Test 0 / / ,,,,'' Specific Gravity '0 0 y� Ar J • TRANSIENT SUPPRESSORS 0 _ REMOTE ANNUNCIATORS ,2._-' —' a NOTIFICATION APPLIANCES S / *.2. Audible -- ti---*ti---* KI idjarrA9.4 Visual ---- 0---- Speakers 0 0 /�i%;- Voice Clarity 0 /t//e}- INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS Device Visual Functional Factory Meas. Loc.&S/N Type Check Test Setting Setting Pass Fail O 0 0 0 ❑ ❑ ❑ 0 ❑ ❑ 0 J ❑ 0 ❑ 0 O ❑ 3 0 Comments: (NFPA Inspection and Testing 3 of 4) d ■ EMERGENCY COMMUNICATIONS EQUIPMENT Visual Functional Comments Phone Set ❑ ❑ Phone Jacks ❑ ❑ Off-Hook Indicator ❑ ❑ Amplifier(s) ❑ ❑ Tone Generator(s) ❑ `❑� Call-in Signal /x -0 " ilL >1 ' he System Performance ❑ ❑ Device Simulated Visual Operation Operation INTERFACE EQUIPMENT (Specify) ❑ ❑ 0 (Specify) 0 0 ❑ (Specify) ❑ > D SPECIAL HAZARD SYSTEMS (Specify) ❑ 0 0 (Specify) ❑ ❑ 0 (Specify) 0 ❑ 0 Special Procedures: , Comments: SUPERVISING STATION MONITORING Yes No Time Comments Alarm Signal ❑ ❑ Alarm Restoration ❑ ❑ Trouble Signal ❑ ❑ • Supervisory Signal ❑ ❑ Supervisory Restoration ❑ 0 NOTIFICATIONS THAT TESTING IS COMPLETE Yes No Who Time Building Management �' 0 /2'.'9/..c Monitoring Agency ❑ ( S/zi Building Occupants ❑ 0 Other(Specify) ❑ ❑ The following did not operate correctly: System restored o nori ah I open n: D. �. / Time: c� ti /243 4,..--- THIS TESTING WAS PERFORMED J ' ••RDA t'I— APPLICABLE N A'S A DA DS. �( Name of Inspector: _ , . `i —•��n r 0__-P Date:/1—t�$ ' Time: Signature: !' �/4is./ Name of Owner or Representative: atr la ea r c Date: Time: Signature: (NFPA Inspection and Testing 4 of 4)