Loading...
SGN2015-00118 CITY OF TIGARD SIGN PERMIT 111111 n Permit#: SGN2015-00118 COMMUNITY DEVELOPMENT Date Issued: 10/21/2015 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: 1 S136CD00100 Jurisdiction: Tigard Name of Business: Sprint& RadioShack Business Address: 11705 SW PACIFIC HWY B Applicant/Agent: Paulus, Jaylene Work Description: One(1)new 105 sq.ft. sign on east-facing wall of building. Multiple letters, separately attached with internal illumination. Permanent: Yes Freestanding: No Freeway: No Temporary: Wall: Yes Electronic: No Billboard: No Balloon: No Banner: No A-Board: No Sign Dimensions: 3'6"x 30' Total Sign Area: 105 Wall Area: 720 Wall Face(Direction): East Sign Height: 18 ft. Projection From Wall: 8 in Illumination: Internal Materials: Acrylic&Plexiglas Electrical Permit Required: Yes Building Permit Required: No Total Permit Fee: $197.00 Conditions: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within 90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon sign shall expire 10 days from validity date. Approved By: IIIIW - ,ou:; Permittee Signature: Not Present City of Tigard RECEIVED r COMMUNITY DEVELOPMENT DEPARTMENT OCT 21 2015 -i',- : = Sign Permit Application CITY OF TIGARD , 1. PLANNING/ENGINEERING SIGN LOCATION /� REQUIRED SUBMITTAL Address: 1 OS � ` Sctite#: v ELEMENTS City/state: ,r-� ene Zip: 9 7g2 3 ❑ 2 copies of elevations no 81/2"x It" Tenant or business: 5-10Y1)–* 2e-ky'nS C le. or 11"x 17"pages(Wail sign elevations must include dimensions Property owner name: as gar- .♦ .., a of sign and wall face and show the �-' location of sign on the wall. Address: PO s'f FLNt//✓f Cr. / 0 ere-led Freestanding sign elevations must City/state: f l,ti i14-/Vo r G/L. .�_. Zip: . 9 77/ he drawn to scale.) Phone:ca-‘1.3:f412/ Email: 6ip if r f//l F WS/yf#ref' ,Gd/ja ❑ 2 copies of site/plot plan,drawn to scale,on 81/2"x 11"or 11"x 17" pages(not required for wall signs) Sign contractor l7l S t IAS o(sw, J V (2 List or diagram of all existing sign Address: r.l'). flr we dimensions and square footage City/state: b Li i.-„C1. A a ['_ Lip: 9"703a El Application Fee Phone:S7)3-98'1 -3-741-...3 l:,,rnail:JQ )prw. /A- irtil sSr,s pv ..cam.,,. CCI3 License #: «'4 I ST Expiration date: (...//7 NOTES: •Contact person 4-4k.0 me-,.. 0,i 1 P+s-a___ Freestanding signs over 6 ft,in height and walls signs of which any element weighs 20 lbs.or more require a building permit for construction. SIGN DATA (Complete all items in this section) If any element of a wall sign weighs 70 Ihs,or more,plans must he prepared TYPE (Check all that apply) by a structural engineer. mew sign ❑ Freestanding ❑ Electrical • Building permits require 2 sets of 0 Alteration to ❑ Freeway El—Wall construction drawings and,if sign is freestanding,2 topics of site/plot plan existing sign ❑ Roof ❑ Other and 2 sets of engineering must be Sign #: "54-- submitted with building permit application. Sign dimensions: 3= Z.I. (h) x '3D (w) LOS sq.ft.sign area New sign: IPS sq.ft. + F. ting iEn sq.ft. =lOS- Total rot: S t'MT USE ONLY Total sign area: t�S sq.ft. /121)_building face sq.ft.= 145 `%of bldg face Casc No.: !V°C)(CP--CO//E Height to top of sign: 18 ft. Projection from wall: a in. Related Case No. s)/:Q Materials: £Le_ Jo A.,+_,. Pee: ''/ a.? Application accepted: Is the sign under 20 lbs.? Li-.r Yes ❑ No By: Z—C Date: /D/02///c (Building Permit required if over 20 lbs) Direction wall faces (circle one): N S L W NE NW SE SW Application determined complete: J the sign have illumination? R'Yes ❑ No By: L Bate: /Cb us— Will If yes,what type: -"nternal ❑ External I:\CURput\Masters\Lind Use Application, Rev.03/03/2015 .,,.1.11M=MmINIM.•,,,•e City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 2 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work. When the owner and the applicant are different people,the applicant must he the purchaser of record or a lessee in possession with written authorization from the owner ur an agent of the owner. The owner(s)must sign this application in the space provided on the back of this form or submit a written authorization with this application. THE APPLICANT(S)SHALL CERTIFY THAT: • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the recluirements for approving or denying the application. I hereby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner,and that plans submitted arc in compliance with the City of Tigard. SIG • TURES of owne of the subject property required. 4%4- i jaLi beta`g /O/J2`/r 111ic tit's signature Print nar(ne Date nix ncr's signature Print name Date Owner's signature Print name Date SIGN PERMIT APPLICATION City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 2 Exterior Site Plan [Sign] I Existing Sign J SF Recommended Sign I SF Qty. Si , Letterset 105 SpRa-L-SEC-42W 105 1 52 Multi Tenant Mon 4.9 Face Replacement 4.9 2 RECEIVED OCT 21 2015 �n__ CITY OF TIGARD 1,-- , PLANNING/ENGINEERING otorma spectru t 1 I Print Graphics th _ ' • n Mgt r IF Big 5 Sporting r- - _ Goods-Tigard " f t � 'i.'.I I fP Baia f I,,,t,n • III r CITY OF TIGARD . I , . approved b Ham,Radi v o . w F �` 6 y Plan ing , ' i Q/ r '' ^•,� r 91705 SW Pacific Hwy r Date: Baskin-•obbi ? T' Initials: �S - "Y-� •Iaid'Paj1?6_ -1 J �' N f CI r, - f: II �• r Ra. r ime ts nys `'° rr 52 f is e Or / d Alle 1J Date tl 1215 City State 7.;.. d Drawing# C47055-Site T priority tNr +,,t..l.. ... - Designer fD PM Ni Aaare>s / sW Paofic Hwy Sete Name 7368-3744 Installation Guidelines Si Linear Illuminated Channel Lettersets (Linear Split) • Remove existing illuminated wall sign R • Patch and repaint metal fascia (SW6069) A B C D E F G H I (Ax B) • Install new remote wired illuminated letterset SpRa-L-SEC-42%0/ i,`! ;::,..J 7111, A @ 9/16" 11'-10 15/16" 2'-2 3/4" 16'-2 11/16" 1'-9 7/16' 13'-3 1/2" 1'-10 5/16" 105.0 /i OCT 21 2015 After Gist , . ;- TIGARD PLANNING/ENGINEERING Sprint ) RadioShack C '\Il ) I1 r , J( ) 11r. �\I( G E w� � �"�f� 3 �lob r 's.i Loner- .a_ ~- .. H • a `i 11 'I! CITY OF TIGARD '�� _ Approved by Pla ning Date: 0 ,2r Center sign horizontally within storefront / C within tower sign band portion Initials: - \tt Sprint Material Material ID Material 0 adioSEIDEc Before 3/16"#7328 3M #180C-221 3/8"Plexiglas III 3/16"#7328 white acrylic Opaque Metallic Grey #2283 Red white acrylic rn RadioShack A 3M #3630-22B III 3/16"White • - —` — Mis Black Blockout Film acrylic#7328 - 1 Acrylite 407-2 Yellow acrylic Existing Letterset:3'-9"h x 28'-0"w 105 sf 0 0,dwmy; C47055-S1 priority 'Ate Harm 7368.3744 _5"— —y_ y 5"deep return - I 5"deep return C 7 _Con #+ 1 Secure mechanical Secure mechanical J L a 1 / fastener as required • fastener as required per site conditions 1"trim cap E' per site conditions 1" trim cap—► P—► 120V power supply 120V power supply housing I housing RECEIVED 3/16"#7328 .080"breakformed 3/16"#7328 080"breakformed aluminum enclosure white acrylic aluminum enclosure white acrylic Y with cover ( with cover OCT 21 2015 Supply wire I r� l � Supply wire CITY OF TIGARD 7/8"plastic �' 7/8"plastic 1 bushing PLANNING/ENGINEERING bushing �, ' r ( c _ Agilight PR0160 . l "" `� Agilight PRO160 •.; white LED module - white LED module - .063"pre-coated UL Listed t .063"pre-coated ' —UL Listed white aluminum back disconnect white aluminum back disconnect switch �C_– -� �� switch Weep hole Weep hole i '_ w/light cover ' 120V power l�'SCC a t s w/light cover e:�_120V power• source -_ _ source 1.5"(approx.)–• —5"— S a_ —5ii-1_ _ 040"Sprint Lt.Silver l 5"deep return metallic aluminum I S r0[ jtLetter Section Detail n� coil / r�O2 Secure mechanical 0 0 Ti lhEyd Letter Section Detail 1"Jewelite Metallic ' fastener as required Silver trim cap . per site conditions I 120V power supply housing 120V power supply Thermoformed yellow .080"breakformed housing y aluminum enclosure 3/8"#2283 Red acrylic acrylic logo face 080"breakformed with cover aluminum enclosure with cover • r ' Supply wire I A Supply wire 7/8"plastic I 7/8"plastic bushing �� Agilight PR0160 I` Agilight SignRayz COLOR ► '`- bushing white LED module I i _,.,.. True Red LED module CITY O F TIGARD �' Approved b .063"pre-coated white li UL Listed 063"pre coated white r: �– UL Listed by PI n n i ng aluminum back !' I disconnect aluminum back _ disconrDgte: switch _ switch �G/ S Weep hole ' • 1/4"dia.weep hole I Initials: �S w/light cover I� y 120V power w/light cover 120V power jsource !. i source V. t Ills Q ys Symbol Section Detail s Ring Area Section Detail $ o Pe"ts�o�ts r Oats 6,Z 15 city/state- Tigard 0R Drawing x C47055•S1 prlorttystgn lye Location agnain,cmaic,,ws,p6.6 Designer TD PM, K7 Address. 5705 SW Pacific Hwy site Name 7368-3744