Plans City of Tigard RECEWEP
'' Building Division
. NOV 16 2015
13125 SW Hall Blvd, Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 CITY OF IIGAlib
TI GARD Inspection Line: 503.639.4175 BUILDING DIMS W
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 14jj1 '/ ) 2 '?)
City: rc( Zip: cf-7d�11
Owner's me: &r.x.
ci Yen ai
Date: IAA
Contractor's Name: CCB #: 43,0 Li6q
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation 111 Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? Z No OSSC or ORSC for
design requirements.
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure "C" or less?
No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes 071 Yes the prescriptive path.
and/or their accessory
Ground structures. I I No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
Yes the prescriptive path.
above
❑ No
1
I:/Building/Forms/PhotoVoltaic-Chccklist.docx
Is the construction
Type of material wood and does Yes If"Yes", qualifies for
yP the construction qualify v
Construction as "conventional light I No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. I Yes If"Yes", qualifies for
the prescriptive path.
No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. , If"Yes", qualifies for
Yes the prescriptive path.
n No
Is the combined weight Yes
of the PV modules and If"Yes", qualifies for
racking less than or n No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation ( '
layout in accordance '`� Yes If"Yes", qualifies for
•
with Section 305.4(3) of q
the 2010 Oregon Solar ( I No the prescriptive path.
Code?
❑ Metal
•
Single layer If roofing material is
Roofing Check the type of n of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
tY of composition
•
✓✓✓✓ ���\ shingle.
Is the roof mounted Yes
Connections of solar assembly
the solar assembly connected to roof n No If"Yes",prescriptive ipti e p for
to the roof framing or blocking the prescriptive path.
directly?
2
I:/I3uilding/Forms/PhotoVoltaic-Checklist.docx
•
.
I.Y Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
Yes the prescriptive path.
n No
Attachment of
roof mounted If the spacing falls
Minimum 24 inches
solar systems Spacing of clamps? within 24 inches and 60
directly to 0/it '(8 inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal anels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2" thickness, k] Yes
•
decking connected to If"Yes", qualifies.for
framing members n No • the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof Yes the prescriptive path.
surface. (— No
3
I:/I3uilding/Porms/Photo Voltaic-Checkl ist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: R L C
Model Number: a75 7"-P
Listing Agency: --kirk,
4
I:/Building/Forms/PhotoVoltaic-Checklist.docx