Report
Packet Contents RECEIVED JUL 28 2015 tion of Scope of Work CITY OF TIGARD Description p BUILDING DIVISION Equipment Cut Sheets Battery back-up/voltage drop calculations for 5496 Battery back-up/voltage drop calculations for 5208XL System Plan CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: [ OTC: [ Permit#: 2C --CL)((-7 Address: IZ715 L'i (42 Suite#: By: Ai!ak Date: '7(54 OFFICE COPY Proposed Fire Alarm Addition and System Upgrade George Fox University Portland Center 12753 S.W. 68th Avenue Tigard, OR 7/21/2015 Scope of Work We wish to upgrade the fire alarm coverage in the library area of this building by extending the existing fire system. A new Silent Knight 5496 power supply will communicate with the existing 5820XL panel and provide power for new bell circuits in the library area. This panel will communicate with the existing panel via an RS485 communication bus but will be supplied with power from an independent 120VAC circuit. All new notification appliances will derive their power from the new 5496 power supply, which has ample power for these devices (please refer to calculation sheets). The addition of addressable smoke detectors and the new bell driver will provide further building protection. An SLC polling loop from the existing panel will process the signals from these devices and activate the building alarm system. The new voltage drop and battery back- up calculations for the 5860XL main panel include original loads and the additional equipment. These new calculations also reflect some corrections to the original figures. Currently, the alarm system is monitored by a UL certified monitoring station so the additional equipment will be incorporated into the panel program and report by device as does the existing system. George Fox University electricians will provide labor for the design, installation and maintenance of this fire system and the estimated value is the following: Estimated cost of project: Parts: $2,400.00 Labor: $3,800.00 Total: $6,200.00 George Fox University Electrical Contractor Lic.# 36-75C Prepared by: Susan Corbett-Furgal Oregon Lic.#: 1510LEA NICET cert.#: 102141 Reviewed by: Paul A. Corbett-Furgal Oregon Lic.#3793S NICET cert.#: 102140 r'•.,-_.::,;:';. : . FIRE SYSTEM ACCESSORY irtSILENT 5496 Intelligent KNIGHT Power Module by Honeywell A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, Gentex®, Faraday,AMSECO and Wheelock®—what you need to drive power-hungry components like ADA notification appliances.The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-328-0103. Model 5496 power Intelligent Power Module • 3 amps per output circuit - The model 5496 is a 6 amp notification • Ground fault detector power expander that provides its own • Communicates to the FACP via 4- x`` w AC power connection,battery charging wire SBUS (wire runs up to 6000 ft) a, ' circuit,and backup battery for use with • AC loss delay option shuts off power fit" fire and security controls such as the to non-essential high-current IntelliKnight Model 5808 Fire Control accessories like magnetic door a /Communicator.The 5496 is the cost- holders effective solution for powering notification • appliances required by the • Lightweight design adds to ease of Americans with Disabilities Act(ADA). installation and reduces shipping The 5496 has built-in ANSI cadence costs • UL 864,1481 & 1971 listed pattern,which can upgrade older ._ , x control panels that lack cadence • ANSI Cadence pattern output 4 0 ,,; capability.The Output circuits can be capability built-in .t_ . ., ! programmed as Notification Appliance Specifications 17 . s •Q` "''' Circuits,or as Auxiliary Power - -----. (configurable for,constant, resettable, AC Input: 120 VAC at 2.7 A or door holder power). Output: 24 VDC at 6 amps 5496 Intelligent Power Module Features Current: Ambient Tem • UL Listed for 6 amps of notification Standby 40 mA Temp.: power Alarm 160 mA 32°to 120° F (0°to 49° C) • Power supply's advanced switch Dimensions: mode design reduces damaging Notification/Aux.Power circuits: 4 12.25"W x 16" H x3"D heat and manages power up to 50% Output configuration: (30.88 Wx 40.64 H x7.62 D cm) more efficiently than other systems 2 Class A(Style Z) • Built-in synchronization for -4 Class B(Style Y)(1 Class A&2 UL UL appliances from AMSECO, Gentex®, Class B) CSFM Faraday, System Sensor®, and Amps per output circuit: MEA 429-92-E vol. XIV Wheelock® 3.0(6.0 amps total) • 24 VDC filtered output voltage Compatible FACPs Notification circuit output: • Four power-limited notification 20.4 to 27.3 VDC,3.0 amps each, • IntelliKnight 5700 outputs; 2 Class A or 4 Class B,or 1 • IntelliKnight 5808 Class A and 2 Class B 4.7k EOL resistor required on each g Class B circuit • IntelliKnight 5820XL • NACs are programmable as • IntelliKnight 5820XL-EVS Notification Appliance Circuits,or as Battery charging capacity: 35.0 AH auxiliary power to be used as constant, resettable,or door holder FIRE SYSTEM ACCESSORY • Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power.The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power).The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Output 1 .,1 SBUS Communication �-4 - To a Compatible Output 2 -44 �, _,`' Silent Knight FACP *lit:tAr4p,A' "W,,41'*.-- ''''' ...4 0.- Output 3 .` ` - Output 4 1 ._ ,g 1 FA[F![ Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power gith SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350387 Rev E subject to change without notice.For more information,contact ©2013 Honeywell International Inc. by Honeywell Silent Knight 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103,Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com I V_ SvsrE 7 t1-.,;.11,4: 7.,',•.::,,,,-, , --..,kit,..e,,... ,,,2,,i rLill' ,,P° ems--. '1 :tw. t J f r.s{t/^ i' s 3 X' Indoor Selectable- tEa '.'E ,¢fr• Output Horns, 0.44 s x � .'{ } x Strobes, and ,k „ � ` � }t Horn Strobes for e' �4r, h � <<. Wall Applications $ - r +� -.L '1 j SpectrAlert®Advance audible visible notification products SPECTfed''t are rich with features guaranteed to cut installation times . ., , rn 71111 tro 3111.:fileirr and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 arid 15%75 candela • Field-selectable candela settings on wall units:15,15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, 30,75,95,110,115,135,150,177,and 185 strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING (11,:01) 0 MEA , i AltP approved 7125.1653186 indoor Wabos) LISTED Beveowo pP 7125.1653aOa(rorn strcbos. 54011(cbbnos,horn strobes.holm) 3023572 MEA452.05.E chuno strobes) 55512(s0abos1 71354653 189(holm.Nimes) SpectrAlert Advance Specifications Architect/EngineersSPectticat'ions f4:,. }2, ' 3AMN.;:gft ' 5 , c„ * :q General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. P.*Zia WElectiical S eciflcatlons 7 ' ^ ` t 1Fi f" - r°' 11 ""'`�">' '�"' a°a . `" P �:�`t..�..g:•. o ,�.:..�.,.�..,�" �_.�..:.c���r.��s,-�a:��.r;�..�:u':��'s?�.- to.�i:: Standard Ooeratina Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 1010 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-MountTrim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL`rMax'Sirobe,Current D rw(mA,RMS)wommamm9 ULkM x Hom CurrerOraw(mA_RMS) +.,'EA 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 _ NA NA 181 • 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 U'L'TMEV.Current;Drawk RMS)2;W1re,Hom.ili5l3 Standard Candei ange(15-115 od) ER '`"`°A 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 .ULvMax.?CurrentDraw_(mA;RMSV2 Wire:HomSYrobe High;Candela,Range;(135-:;185cd)��MM;,M ,, _a: �z,p„ ; 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 -temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 2G7 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data ._,.,.r - c _. .n ,M arra s - >e. . Horn,and;HomStrobe0utput''(dBA).t,�y;� `,,,,,.,,,�, ,c�Y,,��;'-fit” `..�. .'� 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anecholc Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-lemporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Bt Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions COMM, 111Wri I 11111 C-1 5.6"" Wall-mount horn strobes SpectrAlert Advance Ordering Information Modeiy',• Uescnp?fon VazPgr a` YRZM . Model aoesenptgn. °'' c-„ avm s, h Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RI-I-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe.High cd.White P2'■-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Piain P2W1l 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box.Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO'marking on cover 'Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. 'High cd"refers to strobes that include 135,150,177,and 185 candela settings. �5I'E7v 3825 Ohio Avenue•St.Charles,IL 60174 02014 System Sensor. �C��®�" Phone:800-SENSOR2•Fax:630-377-6495 °' 'ca'°a 1bMange mtno^n"t=e.v„1 encenzo,�n ��� IC Iacurrent goductNorma'sn.nc4dngN1Imes: rtmdNtsSLIarhea www.systemsensor.com AVDSIe201•in4 • ,' - . •-- SILENT Addressable Photoelectric KNIGHT Smoke Detector by Honeywell Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics.The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO approximately every 15 seconds, Analog/Addressable indicating that the head is 4.-t.,,,,,-k- :-. ^:s.;^:s. Photoelectric Type Smoke communicating with the loop.The ` Detector LED lights continuously during the ^ .1`",,? rc ;, The SD505-PHOTO is particularly alarm period. - Jr;, P Y l suited to detecting dense smoke Features I. `'' .. A,'..-.-q- `- I typical of fires involving materials • Low profile, 2 inches including =,. such as soft furnishings, plastic, p g . °.. ��° - foam or other similar materials Simple and reliable addressing .R:;-4,-4 "'°'" which tend to smolder and produce without mechanical switches large visible particles. • Automatic compensation for SD505-PHOTO Smoke Detector The detector features automatic sensor contamination compensation for contamination • Built-in fire test feature Ambient Temperature: 32°F to and a simple detector calibration • Simple detector calibration 120°F (0°C to 49°C) test procedure that can be run from testing through the control panel the panel or remotely (using the or remotely through a Mounting: 4"Square, 4" OCT, WindowsTM based downloading WindowsTM based computer Single gang mud ring software). software. Relative Humidity: 85% non- Operation • Vandal-resistance locking condensing The SD505-PHOTO units made u features p Field cleanable Air Velocity: 0 -300 FPM of an LED light source and a silicon • photo diode receiving element. In a • UL listed, meets NFPA 72 Ch 7 Compatible Bases: SD505-6AB normal standby condition, the requirements (Sold Separately) SD505-61B receiving element receives no light • CSFM approved SD505-6RB from the pulsing light source. In the • MEA approved SD505-6SB event or fire, smoke enters the • FM Approved detector and light is reflected from Specifications the smoke particles to the receiving element. Operating Voltage: 24-41 VDC The light received is converted into Current Consumption: an electronic signal. Under normal Standby: .55 mA P/N 350225 Rev G conditions, the status LED blinks Alarm: .55 mA ©2015 Honeywell International Inc. / t b v). SJ r _OO O S- �� • \ - • •- • Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO.The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady.The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector.The test method shall simulate . effects of products of combustion in the chamber to ensure testing of detector circuits. t� Diameter=5-15/16" M y% Diameter = 3-15/16" -`" l4 .off.. �.7y� `yam {y T,,;.'� r4, �9'al•fr[,� cf 11 } I Jam' ! , n5��{P y. . . I ' 5 Height = 2 inches, � t� :Ma_, y , , 1 including base O-er ='# - ; .ti,:j u d . y r •.:n ° .t 4_ ��-o *, N I _ Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) • SILENT This document is not intended to be used for installation purposes.We try to keep our ti KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800)328-0103, Fax: (203)484-7118. www.silentknight.com _GluLat Proj�t.Val�p. SILENT s ,r ` Name: Portland Center Library Remodel 'Standby Hours: 24 KNIGHT, ti_ P�otectlD: Alarm Mins: 5 Prepared By Deratmg Factor 1.2 ,.'-i:2-''' ''',::.>,::- ' ' 5496 Power Expander Calculations Date. 7/22/2015 Voltage Drop Warning g A "_. Version 02.24.09 .Threshold%.. 10 41 ° Panel-ID:- 5496 -`Model:-5496 Power Expander Max NAC Current 3 0JAmp Location: 1st fir library Volts: 24 VDC` - -" ,r,1,.-,---,,= Max'Panel Current-"a6`0 Amps 4;,„: .,4 4' °T-;k-',.w`,:..;-'-.,,,' Current Draw •. ..",Wire-AWG: ='Ohms Per Length(ft) :Actual-.";Volts]@;.r:"'o Part.# .Descnpton, :�,: .-"Qty. /oDrop - -y Standby Alarm _&-Type, = •:1000-Ft:; One-Way Ohms TiEOL'- _n 5496. 5496 Pwr Module . 1, 0.040 0.160 - .. �'`.�Y' ,< :::;f'-'''..,..,-..,!": , - ' - - ,. NAC#1 Notification Appl Circuit 0.000 0.780 #16 Solid .. :;4:02, • " 310 :' .2.49-;- °:18.46';" 9.53% NAC,#2� Notification Appl Circuit 0.000 0.912 #16 Solid r,;;�'�4.02"-' 270 . ,'2.47 1:8.42`°1 9.70% `'NAC"#3 • Notification Appl Circuit 0.000 0.000 #12 Solid :';',I.':',1'-'.59'" . " _.0.00, t-_';20.40;0 0.00% :;NACi#4 i. Notification Appl Circuit 0.000 0.000 #12 Solid 's--,1,-59 , -, 0.00 , -. 20:40,:- : 0.00% ;„Total StandbyCu"rrent(Amps) 0.040 1.852 'Tot'aFAlarm Currenf.(Amps):.:`'”" . ;; "' _' '.Sfandby:"Time:In Hours ",24,'. ,0i083h: Alarm Time.In:Minutes=/60'>' , ,(5>M ins), .Total"Standby=AgH'Required 0.960 0`154',Total Alarm=AH: °�'r ,4'""•' -- Regwred"�`� ' .Total°Conitined AH-R'equired 1.1'1:: `� Command Shortcuts Multiply'By The°berating"Factor 1.20 f f -, Minimum.BatteryAmpHours Required 1.34: . .. Configure Circuits Print Page s, • ....._____—___ IZ:1 SILENT 1. 1 KNIGHT . i Circuit Configuration Project Name: Portland Center Library Remodel r Project ID: 0 Prepared By: 0 Date: 7/22/2015 . , . . Ckt. NOiriberi::.,NAC#1..- ::„,', : ' . ' , ..„.,..-,':;:.:., --.,. ,,, :-./.Panel ID 4...■„• " •o , .. Ckt,NarrieAA/eSt DoWnstairLibrary, , '- '''.'-'..-,ffr'r',:,';',> : '',', - •,--2,'OSe Notification Appl Circuit '7. .i.1:, -,t,', Device;',-,:::::: L' ., ..;.-,54,0k31.': ...;?:' QtY '.:,-.-i'e'Al,'-...,,':c: .,s.w.- ',',;.,',:1,'`,..,,;:4,gil,''.',:, ;' 1,":-„,?...',:;,,,,',,,,,*i.z,,,5.0„•:.:.,,,,-7,,,, ,,,,,„,,,,, ,„:0,A,,,,%1„,,,,,A,,,,,,- ,, -: '::,'',:.:,'--7,',`:--, '77: :•>M',.41'''..''''F'''' ",:,--..1",4-,',,,, P,?3:,''- -:;,-., '1,44,:"- ,,, W,S6rfC1:44:'t':Al'arlTiV4, tofidIDSi Alaajm„),4„: 2 '''' ' 'V''''V'idb'r' ' d'obedlod'''' " System Sensor P2/PC2 Horn/Strobe (15/75cd) ,:,:',f,:0..0,00::,.',..-:-, '....:', .., .'„,,,,,, .,‘: „H.. :„ , !.., ,,,---,?:-,; 5 System Sensor P2/PC2 Horn/Strobe (30cd) . -.-0.000 ,,,,,,,,0,116,.,,, 0,:000-„„. k;. ,, .580 ,..'., Unused - '.0.O00 , '...i0.600- — (moo Unused i' 0000<2 ''..',-. 2.9 (ioo: ,, „0.000,Ai:t;-',..-,0000 - Totals 0.000 0.780 . • Ckt. Number: NAC#2' --• .- '-.-,-,. .., -' .- - -..--. ,k;---.... -i:.-,-,‘ • Panel ICY..„-.5,4196,- .'- . , Ckt.'NaMe: East Downstairs Library , ; -c-1..::A''s"'.:-= '- - -- U.sa! Notification Appl Circuit .....,.. , .. „ —... .„ . . . . ..,\'''.;.-:.---' , ..r: Current Drain/.Each, .. •''CUrrerit'Dra4 Total Qty.';::::',:„,,,.'„,...,,- ' -..:-.,". ''',.' „ .,:',-,', .1„Device:, ' .,,: -::„•,.:',-;:,:-,-,,,';:.:-:.'' ---,.: ..,::iT- ,.- ., - , ,..,:', — .. ,-,.;,-.. •• -7„: ,, ' ,.,'^',.. -„ ' ' : ' .F,,,,',;, ,,,;,,'-,,f- .-::.' Standby Alarm:' Stantl.bY:,-,,' '''Nar,m 1 System Sensor P2/PC2 Horn/Strobe (15/75cd) ':'i -0:'0,09,,!-,),-- ' ,-Q.:100;.: ..:40000::.,„ 1,,,e0:100. 7 System Sensor P2/PC2 Horn/Strobe (30cd) 011 ".-:1-, Unused :.=.:- 0:00,0:...:-.;:-:W.-;;;Q:00V„'- ,-.-:a:opoL,.!,.f,r.:.-;o.,000i . . ,,,,,,,,,,,.. --,,,,, ..:, Unused , '0.00a::',' -.;,,,j:.:„0j)00,- . ,0000;,-_-, .:1-':;',020,0,0- ,..„ , 0.000000 ..,, Totals 0.000 0.912 'bki:115.1:666NACiii-:: :: ., ,,:;,T, s:-' .- -• i--:: :::'';,,Z 1.',,,WS-,','-::::5" .'1: 6111:57e46e,, :','&H..,:::::T','..,',k-,..-',iz-7,*.;,:izr.- " ,,..- - — " Ckt'Name: Notification Api5I'Circuit ' . ,.. ''',- ., -,'''' . . - ..:-:,:;,uSa:, Notification Appl Circuit V . .' .:-. ,-,-- .. Current,Dravv,Each,, .- : 'Current Draw Total Qty : . : .-. --.. -.,' Device , --,-.- „',:-:=:.- - . - v.,,--,...- v..... - , Standby =.,:.-.'Alarm:„: .'.,;$tar.(0,1214.A:t Alarm .-.., . , , ....... ,,,, ,•.. Unused „,-.?.'0.000: :--;:-..'.0:000'.-;---' 0'.0001,';:.'-!„%,0'.000.:-' „. . . .. „ ... . , ..„ Unused ::::.,;0.000R5i,:;.,:, 0,.Q0c).:,:,:; ,,,;,:0.00()Cti.';.:,..;,--,cr:Q ":. Unused ik40r0,-t0 .: if--0.-,000:,; .: Unused A',,: 0 OA -,:.0.001);!,.: . '4..:0',00,0V.::-.; --],i-dA 0 :' ,,0:00,04.,,--,. ;.i.-,„?,0':000.•,r,„., ' Totals 0.000 0.000 .6lobai,peie�t Volues. tlit SILENT Protect Name:PC Library Remodel Standby Hours: 24 KNIGHT Protect�ID`. Alarm Mins: 5 - '-, ,_ ` Prepared By: Derating Factor: 1 2 5820XL Calculations Date 7/22/2015 rx ` ' Voltage Drop Warning_, "' Version 02 26 09 _ ,-.. ', - .. Panel ID. 5820XL bMode1\5820XLAdd,Fire Alarm Control Panel.r.,, Max NAC Current 3 0 Amps Location: 2nd floor north "Volts 24 VDC� � Max Panel'Current 6.0.'Amps„ ',' r=te, a ,,,r • -� ,._,: ~ r.-Current-Draw,`:,' Wire?AWG`. .''° -0=, Len th ft - 'Actual,'%,`Volts: ' Ckt:# . .- iicuit Name . Qty ..-_ . t .,-', 9 O - . @ -'-%Drop -ma 1 .,:25.: - --. .;Standby_-:Alarm ='-&'Type'. 10O0:Ft:.- One-Way-`,'Ohrtis =- EOL`;;;:' 5820XL -: -r, 5820XL CTRL Panel 1. 0.215 0.385 .''''‘''-'.- -",;;.-.-:-.- '.--- ..:i,...,,,,"--,,, ---",,', „;,=,,',„"-. .., .,,SD500-AIM Addr.Input Mod 3_ 0.002 0.002 - '-SD500=MIM -Mini-Input Module 2` 0.001 0.001 =',,SD500-ARK.,,g.Addr.Relay Module ;1 0.001 0.001 M 1 � >: ,:SD500=PS" `(Addr. Pull Station 6 0.003 0.003 �`N, ;,- ' � � , '.�-SD505=AIS ;;Addr.Ion Smoke Det .,.. 0.000 0.000 y . ''SD505=AHS'~, Addr.Heat Detector „='1;1=0. 0.001 0.001 .4� r :k? err l" . - SD505-APS" '.Addr.Photo Smoke Det 53` 0.029 0.029 < SD505-DUCT,RE`Addr.Duct w/Relay 0.000 0.000 -.. i.:1'.'.E `- ,",, SD505-DUCT Addr.Duct 0.000 0.000 SD500-ANM Addr. Notification Module ' '. 0.000 0.000 r - '" �'' SD500-LED Addr. LED Module ., -' 0.000 0.000 - , ..i '- SD500-SDM -Addr.Smoke Det.Mod. 0.000 0.000 : . „<" - - ::SD505-6RB..1 Addr.Det. Relay Base : 0.000 0.000 � ' � _s SD505-6SB<> Addr.Det.Sounder Base ,..., 0.000 0.000 .: - ''`' '':<-7. - �:SD505=618':"Addr.Det.Isolator Base 0.000 0.000 . r . `' •- -:-SD500-LIM., <Line Isolation Module Tr1'„ 0.000 0.000 5815XL'. 'SLC Loop Expander 0.000 0.000 " ... ' °�. 5860-';,`''.,,;!,,,,LCD Remote Annunc ,"1 .1 0.020 0.025 �. �, ;;1' ' `' ' ' .".6824- '''�"" 0.000 0.000 5824 Serial/Parallel Module ,.-; '4-1-,,, ' 5496'., Power Expander ,'2'- 0.020 0.020 ' 5895XL Power Expander 0.000 0.000 ,t' � LED Annunciator(4G) 0' 5865-4 0.000 0.000 ' -- ' ' . -5865-3 LED Annunciator(3G) 0.000 0.000 -5880_ ''_LED Driver Module . 0.000 0.000 ""- -• 5883:>= --,~Relay Module 0.000 0.000 „-__„ - .-. _- . , - : . PGM=1/O,#1:'' Notification Appl Circuit 0.000 1.000 #16 Solid ',:g'---4.02 '. 250 =2.01:..:, Al8=.49:, 9.85% ,� PGM'170'#2- <,Notification Appl Circuit 0.000 0.800 #16 Solid ---°44.02: 210 'A.69`,,,4 X3;19.05."- 6.62% , ;PGM=_i/O`#3``' Notification Appl Circuit 0.000 0.800 #16 Solid =,4:02;°<- 225 ...1.8"11::,:""_-1>8 95 7.09% PGM4/O`.#4''=' Aux Power Circuit 0.000 0.000 #16 Solid '.4'02f`` X0:00.1":._ 2610,,; 0.00% %P.GM-(/O#5'' Aux Power Circuit 0.050 0.050 #16 Solid > 4 02 „ w0.00'.. = 20'.40'' 0.00% '' PGM-I/O#6_ Notification Appl Circuit 0.000 0.000 #12 Solid .,°'.x.:1':59'-";'` ��^.0;00I.° ,'x'20 40=:.7 0.00% =Total:Standby:Current(Amps) 0.341 3.116 -Total P,lami Curtent'(Amps)``. . "...,.?i• -Standby Time In Hours -'-24/;;',),,, 10.083 Alarm'Tirrie In,Miutes'/60' (5-Mins) ._--TotalStandby'AH-Required - 8.183 0:260-, Total Alarm AH Required: . . . .r, „. Total Combined AH Required.~ .-8.45.' Command Shortcuts . MultiplyBy=The_Derating Factor; ";- 1.20 r . . ; Minimum-Battery'AmpHdurs Required . 10.14-1,,"'- Configure Circuits Print Page I El SILENT KNIGHT Circuit Configuration Project Name: PC Library Remodel r Project ID: 0 Prepared By: 0 Date: 7/22/2015 . .. . Ckt. Number: PGM-I/O#1 " -''.. : –: .. - :, -,,,, , .1,1:ParielilD:., 5820XL .., Ckt. Narne: ;2ndrlo:drN*hoi=n;Str=Obe :::.',,,,- •,, :-::3::::5 ::::=:„ :4-i:aittc?'Op; Notification Appi Circuit ■■ ,''''''.' ., '''''-:: ' ' , ."' - . . ,- . Ct.iriteht'-DrawEaah-,i -:t,'''.'curreritpiravv,T,O"tal,„::: , , . .. Qty -.:'. .'. -- –.:..- ';,-.'''':: ....-,.... . • Device. :." • ',.. „:-•;.., ..,'.–: s.,.,..-- ,c?'--;--::.4. ...:‘,,---,-.„ . .. -, . ,.. ,-,,:,'.-,.,,,',..,k,,n ...,-,-1-.- ,,,,,,.. .-. -- . --.--,-::,–'-'.:;',:,? .,f,',::.: Stanclby..' -. Alarm',,, ,,-,..„StandbYsi ,Alarm._ , :,.. , -. .... 10 System Sensor P2/PC2 Horn/Strobe (15/75cd) .W',--.0-.,00.0.. , 0.100 . ,. " 0:000,-.'., : 1:000. -- Door holders 0..'0.00 . ..- 0.000'- ' „`-0".:00,0,-;?-:,',2.: 9:000 .. Unused ..;;;t ''.0100-0 . :''.-0.000 '',' -.-:''6:00044`:-.:,Ab:000":,','' Unused !;:, ,b(Y:kii3ObT::' ,', .O.do:4;.' :;:!:'.:.'. '.60..CA.,--.:3!:;:'Q.Odio:-- ,,,,,:y.:'0:,000.•%<.,-„',,,,-;\.,:c1:0,00,,V,::.4 Totals 0.000 1.000 . : Ckt. Number: PGIVIllio#277- ''' --,' WO.a hail a .5820XL",''';'',''''''"7:7::;'::''Y '' -,.,.: Ckt. Name:. 2nd Floor .1■1 :hbrn strobe ,-. ...-...,-- ;':T,-,..i-..,, I/O Use Notification Appi Circuit i V . Current Draw Each, ' CurretitDrsa■Ai„Total Qty ' . . .,. , .f.': `:8tandbY-:, Alarm.: •". .:Stridby'is. '' ", Alarm 8 System Sensor P2/PC2 Horn/Strobe (15/75cd) '2'-'00,00_,- 0.100' -.. 0.800 i Unused -." 70..0'00,.' 0.000.'-c, ,(Y. 00 r T,'0,:,000 Unused C)170'Ci0;,,.,„, . 0000 ;. 000.0 : .,:2,'.‘000).0,:!:,-, Unused 009,0::',;:,,•".= ,‘ 00'00 <.0:001:),: ,:i;:-.:=,'60.006m, ,4i0,466'' '' ''',0:,(56.6 .s.: ','•;.1 Totals 0.000 0.800 Ckt. Number::P.G.M411043., — . ' , :: ,:,°,': . 1-.;,:.,0..i:::: Parlel'ID:.5820XL . ' --',-;',. -,,,-.......t" Ckt Name: 1 t":',floci!'N:ball, . -, '''''''''"-- lb iis)e. Notification Appi Circuit i V . . '..:.:."'..i':- .1 ' Cfarerit-Di-aw Each ' "-„CUrrent.DraW-Tatal Qty ' - . , „ ....,. .'. - . Device ., -,i,- .."--.:- .11:;:,.:::.--- ,,,,-, .,', , , ..1 Alarm M‘,?:.. „.Stand by:;: Alarm,:,,;,-,. .Standbylt7,i- , ?:-.; 8 System Sensor P2/PC2 Horn/Strobe (15/75cd) Ir;,.',0.000":":".:, '; 0.100. ,„ -,;..;:,.0':000 ,,,,,,i,,,i-,,,,,0.80,07,,,, Unused j.':; „0.000 ;iL.,,-0:000 :-,' ;',...P:::'.(:):00 0;/ , 0:0001Y,:,,,,, Unused i5:00,0; ,,'„',„ .'..-:.f.',- 0.000i:':.:---7:.':: ' ''ia060 '' I',:';0.00.0 . Unused .t:,:'!0.000,- , :" '0:000 :',.:,: . :,;::(0001.,.-..' :„: 0:0,0,0,:,:. 0i0,00::::f, .,- .:0:06,10 -. • Totals 0.000 0.800 k3swiNT KNI GHT Circuit Configuration ,. [Project Name: PC Library Remodel Project ID: 0 Prepared By: 0 Date: 7/22/2015 ,Cki:A-urti LiirTiii-1/04-5.4J!,--t-' -:••;.,.. - ;-,-f:= ,1-'1,1r -:::-:-•,:‘,::-:;')1-,!:`:::::'.7.-.::34,::,-0-6ilfbf:*10)%:.-,,,.•:`,:::::-:-.ii ,',::-1-;7:;:'.::--:,-,44.5..,:".- : :•';:'-.1--;,' w --;--,,,,--,;• 1 .. '-•,,,t,', •- -,::::.;,•;' ,/,---,:•.' ••••-- - •----- -- , iiiii C1'<i"Nartie:'DO'briliblders"Niti,,i4h-'-- '':''''''''''4!-'' -,,,"'''"''''':''''''''''"'* ' -,',----,-,t:,:vatjle., Aux Power Circuit .''.0 --4-------,5v .:,,,---: ------: -'-,,-- , ',:‘ 4.-.. " ."',.':.,'•--', : '"'14.;4.::',"'' ,. ,.;:;;...;'.':-`.:' Ctirfelit'DrakiVITotalk UtY];::., :',.:-'2, ..„:-`...:::,-,.-,,--... ':-;:--:-::-': '' - ?...--,--::-=:'pevite,-• .-'..--.:;,-,..,'--.-:'-'.'-,'.:,,..-.,-.,,';',.--.':..g .,,,' „., , _,'e.,' ':-T.:,,:. '-;,..1:•-•!;.:4,":-',..''.' Stail'cly,..i ';‘,:z..-.: Alarrrt,:::::,,-.-"-:-.Statielbyt'',:,:::: Alarrri-.''',', 8 Door holders . --':,0.000.,. . ' 0.000 ” '.::-.'0.9901.,, ,.' :'''' 0:000 • : Unused „,,06,0i : -: 0.000 •°- ,-.:-,:0'-.000, : . ,,•.0.000.---: Unused :''k-Q:0.00:'---,..' -- -. 0.000 0.0001,.'S Unused 0:0(;)1:3!",%:' ..,.,---,,-,0.00C):.'',.„'":::---*.10.000 *".,...i:-.0.000:, Totals , 0.000 0.000 ' ' ‘Cki. NiiMber:r.T001041/0-#5 ',' '' • ''''-."2;,=,-- - - ' ' ',-,Panekla,.'5820XL ''::`'",72'is'Vs4k -s-,' . . _ . . Ckt: Nathe:,'. -4'Voll.Elev relay -. ' ' ').-,'.. :'-' " - liC):,..Ue. Aux Power Circuit V ,;:',' -- „ "cuiteht Draw Each- - _ Current Draw'Total Qty -,/'T:,:;,,,, -;, / ' ., . Deyice -.,.. ',, .,:f ' „• _'' . ,,.,,,,-, ,'-',- ' , -.' ..'' ..' Standby,,,,' Alarm; ' Standby,i-,-;.,.,Alarm:5.!„ 1 elevator relay 0.050.:':'e-',...;-0,.,050',..--I, ::,,i,P:(:)50:Z-..47-,--;;;,„,..;0.050:„:„- Unused b4004 ::-i:,';,.6006';"!:::,,,,,n'O66-':::,:k t!--,,,73':,16676,0,..',1. Unused '.,,,!',50.:000-;,7: ',:- 0000' : ;;;;"?':''C.):::'DQ(i:,:-::';„,-S-1....0,..,0007, ' Unused ,,,,...,-0.00 0'; ;s '0.000 000.-:-..'-. --,:-.',0000, 2- .-- ...--,.... ...., ,.. ..... ..,.. .., 0.000.. , Totals 0.050 0.050 ---'''akf..'-NUrilber.-'P61VILI/o 0:.`..: •-.- -':,,,,:::',:,‘.i.:... l'i D::::',.,.:6EZ0)(1f-,'.,-, i,..-,,,,,,,,,;:::,-,,,x,,..-.:', ckt..-Aprne'..f0f- -A:„' -..;. ,- ' : '-,;:: :-::,,,.;:,, ,..,' :' ,... ,,:::,,,,:::,,,-,:„,-, -:- ,,:<:1/amse:' Notification Appl Circuit :V . .:- ,4,'.''';:Cuffent Draw Each,'. Current Draw Totar,'Z' Qty Device ',, :- '•,::,:' -...,.;;;5,',. ,- ,--,z-, _,,.,. ' .---<7`: ':' ', ' ' , - :',:;=,-;4'•:„'',- ''''''; : ': '''''',' Standby , Alarrhi-... .;'.,;S:taiidti.i.,:' ,,f;Alarrri-ii;:. Unused .....-;,6-.600A,:' 0.006 1060:2.,:'',.'s--::: 0.000 Unused 0:000"-,;',-,.:'. -0.000-,;,:-.: ..i-`'. ,..0,000:.-s '.'.I'-o000 S'y Unused .7,6 j,(1-:00(Y.,-,', :-.',..0,.000..1,-;;15,:),,00Q0:,,, ? ,,'.-,?-0;.,000-,.,, i. Unused 'Y..:0.0.Q0 .',.." ':',.-- 0;0.9.Q, , "-:-:-?,(1-M0. ' ' ::%."0:1009s:4.-. aa:000',1.2 '..'''0:00.9i,4 Totals 0.000 0.000