Permit I.Y Ii13:141"" CITY OF TIGARD MASTER PERMIT ' COMMUNITY DEVELOPMENT Permit#: MST2015-00189 ,I 't 4y..,E.' // Date Issued: 10/28/2015 -rid/0kb 13125 SW Hall Blvd,Tigard OR 97223 503 718 2439 pj4 At Parcel. 2S111BD00302 Jurisdiction: Tigard Site address: 9930 SW INEZ ST Subdivision: PEMBROOK HEIGHTS Lot: 2 Project: Sunada Project Description: Increase wall opening from 34"to 95" Increase existing window opening from 36"to 48" BUILDING Floor Areas Required Setbacks Required Stories 0 Bedrooms 0 First 0 sf Basement 0 sf Left 0 Parking Spaces 0 Height 0 Bathrooms 0 Second 0 sf Garage 0 sf Front 0 Smoke Dwelling Units 0 Third 0 sf Right 0 Detectors Yes Total 0 sf Value $3,500 00 Rear 0 PLUMBING Sinks 0 Water Closets 0 Washing Mach 0 Laundry Trays 0 Rain Drain 0 Urinals 0 Lavatories 0 Dishwashers 0 Floor Drains 0 Sewer Lines 0 SF Rain Storm Sewer 0 Drains 0 Tubs/Showers 0 Garbage Disp 0 Water Heaters 0 Water Lines 0 Catch Basins 0 Bckflw Prevntr 0 Footing Drain 0 Ice Maker 0 Hose Bib 0 Backwater Value 0 Drywell-Trench Drain 0 Other Fixtures 0 Other Fixture Units MECHANICAL Fuel Types Air Conditioning N Vent Fans 0 Clothes Dryers 0 Heat Pump N Hoods 0 Other Units 0 Furn<100K 0 Vents 0 Woodstoves 0 Gas Outlets 0 Furn>=100K 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feedors Branch Circuits 1000 sf or less 0 0-200 amp 0 0-200 amp 0 W/Svc or Fdr 0 Ea add'I 500 sf 0 201-400 amp 0 201-400 amp 0 W/O Svc/Fdr 0 Mfd Home/Feeder/Svc 0 401-600 amp 0 401-600 amp 0 601-1000 amp 0 601+amp-1000v 0 1000+amp/volt 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo N HVAC N Security Alarm N Vaccuum System N Garage Opener N All Other N Other Description Ecompasing N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: BRAY,JAMES N REVOCABLE TRUST RENTAL HOUSING MAINTENANCE SERVICE Required Items and Reports(Conditions) 9930 SW INEZ ST PO BOX 317 TIGARD,OR 97224 DONALD,OR 97020 PHONE PHONE 503-678-2136 FAX 503-678-2138 Total Fees: $240 63 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days ATTENTION Oregon law requires you to follow the rules adopted by the Oregon Utility Notification__Genter Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090 You may obtain a cop les or direct questions to OUNC by calling 3 232 198►j1 8011 332 2344 Issued By: .4iiiiiiy----..-.1?—s---- Perm MM.-Signature: �y . 9.4175 by 7:00 a.m.for the next available inspection ate. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applicati C Residential ��� FOR OFFICE USE ONLY ' City of Tigard OCT 2 6 2 01 5 Received � S Date/By 0�O / i Permit No MI Z/5 00 P Q 9 13125 SW Hall Blvd,Tlgard,OR 97223 Plan Review, 0 Phone: 503.718 2439 Fax' 503.5 18 6 Date/By 1pll"� 1 is Other Permit T 1 G A R D Inspection Line 503 639 4175 ti A H ` r fl ll L➢ARD Date Ready/By / J°r�s ® See Page 2 for Internet' www.tigard-or gov BUILDING DIVIS¶® Notified/Method (0/ / Supplemental Information TYPE OF WORK �tZR(EQ/UI`REED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ and 2-family dwelling ❑Commercial/industrial Valuation: 5 3)£ QO I ❑Accessory building ❑Multi-family Number of bedrooms: 3 1111 Master builder ❑Other: Number of bathrooms: S JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: q S3 ci S,,J ;�„jt,L New dwelling area. square feet City/State/ZIP:--; c p\ ' OR_ 5' ') 2 zy Garage/carport area: square feet Suite/bldg/apt.no.: Project name: 1 Covered porch area square feet Cross street/directions to job site: t.,3 1 170 Deck area: square feet f•e•t-I ,..a.,.1N -"Tt, v,,,c,) ‘opa -7,,4,a t.a., --- ":•-k. S,a Z,.tc,2._. Other structure area• square feet ~c La.P-and c ) L. .Z. i P2w �Q*- 'f tst GWrICA at,..) get c1,-) s REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. ri Valuation: S cX S-1J' Existing building area square feet 6 x`-411'(A«•- (4)..)\4,,J, ,/ ;^•c t Zit JLC qL., New building area: square feet ECIPROPERTY OWNER ❑ TENANT Number of stories: Name: '-s- S- Li i‘,4_1\ Type of construction: Address: N.,,,,,_,__ t� 5 �u.JC, Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: Q ❑ APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (� (Please refer to fee schedule) Business name: AStructural plan review fee(or deposit): Contact name: FLS plan review fee(if applicable): 1 Address: City/State/ZIP: Total fees due upon application: Amount received: L Phone:( ) Fax: :( ) .,. ._ E-mail: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial a d residential prescriptive installation of CONTRACTOR roof-top mount,. 'hotoVoltaic Solar Panel System. �, Business nameZ Submit two(2)sets . roof plan with connection details "'° �`' 's s ""�''��' S 'ccS' " and fire department accev .long with the 2010 gon t Address: %13450 1 rV C- tpviev•a S Solar Installation Specialty s.: chec • . Permit Fee include revi- lCity/State/"ZIP:�U,,,,,qt�& , v� q7 p a ( mistrative fees): $180.00 Phone:(Sp 3)6,-)8"--2„1"5 c, Fax:(5o3 )47e.-Z /B S urcharge(12%of permit fee): 1.60 CCB lie.: IL3yz—I Total fee due upon application: $201.60 / Authorized signature' ' 5— // This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by n-County Building Industry Print name:/WA/ __- Date:,,/,` /, Service Board. -r I.\Building\Permits\BUP-RESPermitApp doc 02/24/2011 440-4613T(I 1/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY Received I City of Tigard Permit No v 13125 SW Hall Blvd,Tigard,OR 97223 Associated C Phone: 503 718 2439 Fax: 503.598.1960 Associated permits. TIGARD 24-Hour Inspection Line: 503 639 4175 ❑ Electncal ❑ Plumbing ❑ Mechanical Internet: www.trgard-or. ❑ Other. THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. I I Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ❑ ❑ ❑ there is more than a 4-ft.elevation'differential,plan must show contour lines at 2-ft. intervals); location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage; impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Oregon and shall be shown to be as 9licable to the •ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ ❑ 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. 1\Building\Permits\BUP-RESPermitApp doe 02/24/2011 440-4613T(I 1/02/COM/WEB) Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 9930 SW INEZ ST, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - No C of O MST2015-00189 David Young Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 9930 SW INEZ ST, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2015-00189 David Young Violation Summary: Inspector Contractor